• Title/Summary/Keyword: Tracer Experiment

Search Result 120, Processing Time 0.026 seconds

Development of CFD model for Predicting Ventilation Rate based on Age of Air Theory using Thermal Distribution Data in Pig House (돈사 내부 열환경 분포의 공기연령 이론법 적용을 통한 전산유체역학 환기 예측 모델 개발)

  • Kim, Rack-woo;Lee, In-bok;Ha, Tae-hwan;Yeo, Uk-hyeon;Lee, Sang-yeon;Lee, Min-hyung;Park, Gwan-yong;Kim, Jun-gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.61-71
    • /
    • 2017
  • The tracer gas method has an advantage that can estimate total and local ventilation rate by tracing air flow. However, the field measurement using tracer gas has disadvantages such as danger, inefficiency, and high cost. Therefore, the aim of this study was to evaluate ventilation rate in pig house by using the thermal distribution data rather than tracer gas. Especially, LMA (Local Mean Age), which is an index based on the age of air theory, was used to evaluate the ventilation rate in pig house. Firstly, the field experiment was conducted to measure micro-climate inside pig house, such as the air temperature, $CO_2$ concentration and wind velocity. And then, LMA was calculated based on the decay of $CO_2$ concentration and air temperature, respectively. This study compared between LMA determined by $CO_2$ concentration and air temperature; the average error and root mean square error were 3.76 s and 5.34 s. From these results, it was determined that thermal distribution data could be used for estimation of LMA. Finally, CFD (Computational fluid dynamic) model was validated using LMA and wind velocity. The mesh size was designed to be 0.1 m based on the grid independence test, and the Standard $k-{\omega}$ model was eventually chosen as the proper turbulence model. The developed CFD model was highly appropriate for evaluating the ventilation rate in pig house.

Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.

Flow Characteristics of Polluted Air in a Rectangular Tunnel using PIV and CFD

  • Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.609-617
    • /
    • 2012
  • The flow characteristics of polluted air are analysed by comparing the results obtained from PIV(Particle Image Velocimetry) experiment and CFD(Computational Fluid Dynamics) commercial code. In order to simulate the polluted air flow, the olive oil has been used as tracer particles with the kinematic viscosity of air, $1.51{\times}10^{-5}m^2/s$. The investigation has done in the range of Reynolds numbers of 870, 1730 and 2890 due to the inlet flow velocities of 0.3, 0.6, and 1.0 m/s, respectively. The average velocity and the pressure distributions are comparatively discussed with respect to the three different Reynolds numbers. The results show that the outlet flow rates at three different Reynolds numbers are equivalent of 165 to 167 percent of the inlet ones. The pressure drop occurs in the model closed at both end sides and the highest pressures at each Reynolds number are positioned at the top of the tunnel between the inlet and outlet.

Dispersion characteristics of pollutant by a field tracer experiment in river (하천내 현장실험을 통한 오염물의 확산 특성)

  • Kim, Ki-Chul;Jung, Sung-Hee;Lee, Jung-Lyul;Suh, Kyung-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1971-1973
    • /
    • 2009
  • 본 연구에서는 하천에 유입된 오염물질의 거동 및 확산 특성을 파악하기 위하여 하천에서 추적자를 이용한 현장실험을 실시하였으며, 실험구간은 경상북도 경주시 에 위치한 하천으로 총 길이 2km, 평균폭 25m로 이루어진 대종천이다. 현장실험에서의 추적자 실험결과를 수치모형과 비교하기 위해 2차원 수심적분 모형인 RMA2, RMA4를 이용하였다. 2차원 동수역학적인 모형인 RMA2를 사용하여 흐름장을 모의한 후 계산결과를 2차원 수질모형인 RMA4에 입력하여 농도자료를 모의하였으며 상 하류단의 경계조건은 현장 실험시 실측한 상류단의 유량과 하류단의 수위를 적용하였다. 실측한 자료를 경계조건으로 모형에 적용하여 시간에 따른 농도값을 계산하였으며, 그 계산값을 추적자의 농도 관측값과 비교하였다. 계산결과는 서로 잘 일치하였다.

  • PDF

An experimental study on the mixing of evaporating liquid spray with duct flow (덕트 유동에서 증발을 수반하는 액상 스프레이의 혼합 특성에 대한 실험적 연구)

  • Kim, Young-Bong;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.93-96
    • /
    • 2005
  • High temperature furnace such as Steam power plant and incinerator contribute considerable part of NOx generation and face urgent demand of De-NOx system. Reducing agents are necessary to use De-NOx system. In this study mixing caused by direct injection of reducing agent solution spray into flue gas duct was measured. Carbonated water was used as tracer and simulated agent because ammonia as a reducing agent is not proper to experiment. Mixing and evaporation must occur simultaneously and quickly enough to achieve desirable efficiency. To achieve that, the angle of attack of static mixer and the location is simulated and $CO_2$ concentration is measured.

  • PDF

PIV measurement of the flow field in rectangular tunnel

  • Park, Sang-Kyoo;Yang, Hei-Cheon;Lee, Yong-Ho;Chen, Gong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.886-892
    • /
    • 2008
  • The development of fluid mechanics is briefly reviewed and the importance of fluid flows to heat and mass transfer in nature as well as to science and engineering is outlined. This paper presents the experimental results of air flow in the rectangular tunnel which has four different exhaust outlets, each distance of which from the inlet is 0, 30, 60 and 90mm respectively. This experiment is conducted by using the olive oil as the tracer particles and the kinematic viscosity of the air flow is $1.51{\times}10^{-5}\;m^2$/s. The flow is tested at the flow rate of 1.3 $m^3$/h and the velocity of 0.3 m/s. PIV technology can be used to make a good description of the smoke flow characteristics in the tunnel.

Effect of rotational motion of piston ring on the oil consumption -2'nd report: Relationship between phase angle of ring end gap and oil consumption (피스톤링의 회전운동이 오일소모에 미치는 영향-제2보: 링갭의 위상각과 오일소모와 의 관계-)

  • 민병순;김중수;오대윤;최재권;진준하
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.81-88
    • /
    • 1999
  • In order to understand the relationship between the phase angle of piston ring and oil consumption was measured by analyzing $CO_2$concentration in exhaust gas. The use of hydrogen fuel not gasoline makes this possible because all of the carbon component in exhaust gas can be assumed to be produced from oil. As a result of experiment, it is known that the oil consumption varies periodically and a specific location of ring end gap was found at each peak of oil consumption. Therefore, it was found that the oil consumption was not constant even at the same operating conditions and this is because the relative locations of top and 2'nd ring end gap change arbitrarily.

  • PDF

The Measurement of Bubble Driven Flow Using PIV and Digital Mask Technique (PIV 기법과 Digital Mask 기법을 적용한 버블유동 측정)

  • Kim, Sang-Moon;Kim, Hyun-Dong;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2700-2703
    • /
    • 2008
  • An experiment on bubble-driven flow was performed in order to understand fundamental knowledge of flow structure around a rising bubble in a stagnant fluid. The measurement technique consists of a combination of the three most often used PIV techniques in multiphase flows: PIV with fluorescent tracer particles, the digital phase separation with a masking technique and a shadowgraphy. The key point of the measurement is that the background intensity of a PIV recording can be shifted to a higher level than a bubble region using a shadowgraphy in order to distinguish from fluorescent particles and a bubble as well. Flow fields were measured without an inaccurate analysis around a fluid-bubble interface by using only one camera simply.

  • PDF

Study on visualization of water mixing flows in a digester equipped with a vertical impeller by using radiotracers

  • Jung, Sung-Hee;Moon, Jinho;Park, Jang-Guen;Lim, Jae Cheong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.170-177
    • /
    • 2020
  • A mixer with a new concept design has been adapted into water treatment plants. It reportedly cuts down the energy consumption of the mixer by the new mixer, which moves vertically and creates internal flows toward its bottom. However, no experimental observations have been made on the internal flow caused by a vertical impeller. In this study, a radiotracer experiment, radioactive particle tracking (RPT) technique, and particle image velocimetry (PIV) were carried out to visualize the flow in the mixer, and compared to each other. The results show that the flow patterns from these techniques are very similar to each other, and the performance of the mixer was good enough to mix the inner materials.