Development of CFD model for Predicting Ventilation Rate based on Age of Air Theory using Thermal Distribution Data in Pig House |
Kim, Rack-woo
(Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University)
Lee, In-bok (Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University) Ha, Tae-hwan (Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University) Yeo, Uk-hyeon (Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University) Lee, Sang-yeon (Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University) Lee, Min-hyung (Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University) Park, Gwan-yong (Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University) Kim, Jun-gyu (Department of Rural Systems Engineering, Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University) |
1 | De Jong, T., 1990. Natural ventilation of large multi-span greenhouses: Proefschrift Wageningen. |
2 | Goedhart, M., E. Nederhoff, A. Udink ten Cate, and G. Bot, 1983. Methods and instruments for ventilation rate measurements III. International Symposium on Energy in Protected Cultivation 148. |
3 | Han, H. T., C. Y. Shin, I. B. Lee, K. S. Kwon, and Y. I. Kwon, 2009. Estimation of local mean ages of air in a room with multiple inlets. The Society of Air-conditioning and Referigerating Engineers of Korea. 148-153 (in Korean). |
4 | Hong, S. W., I. B. Lee, H. S. Hwang, I. H. Seo, J. Bitog, J. I. Yoo, K. S. Kim, S. H. Lee, K. W. Kim, and N. K. Yoon, 2008. Numerical simulation of ventilation efficiencies of naturally ventilated multi-span greenhouses in Korea. Transactions of the ASABE 51(4): 1417-32. DOI |
5 | Kwon, K. S., I. B. Lee, H. T. Han, C. Y. Shin, H. S. Hwang, S. W. Hong, J. Bitog, I. H. Seo, and C. P. Han, 2011. Analysing ventilation efficiency in a test chamber using age-of-air concept and CFD technology. Biosystems Engineering 110(4): 421-33. DOI |
6 | Liang, H., 1994. Room Air Movement and Contaminant Transport. Ph.D. thesis. Department of Mechanical Engineering. University Minnesota. |
7 | Ministry of Agriculture, Food and Rural Affairs (MAFRA). 2016. Major statistics data of Agriculture, Food and Rural Affairs. 11-1543000-000128-10. (in Korean) |
8 | Morris, L. G. and F. Neale, 1954. Infrared carbon dioxide gas analyser and its use in glasshouse research. National Institute of Agricultural Engineering. |
9 | Nederhoff, E., J. Van de Vooren, and A. J. Udink ten Cate, 1985. A practical tracer gas method to determine ventilation in greenhouses. Journal of Agricultural Engineering Research 31(4): 309-19. DOI |
10 | Okada, M. and T. Takakura, 1973. Guide and data for greenhouse air conditioning. Journal of Agricultural Meteorology 28(4): 223-30. DOI |
11 | Sandberg, M., 1981. What is ventilation efficiency?. Building and environment 16(2): 123-35. DOI |
12 | Sandberg, M. and M. Sjoberg, 1983. The use of moments for assessing air quality in ventilated rooms. Building and environment 18(4): 181-97. DOI |
13 | Whittle, R. and W. Lawrence, 1960. The climatology of glasshouses. II. Ventilation. Journal of Agricultural Engineering Research (5): 36-41. |
14 | Seo, I. H., I. B. Lee, S. W. Hong, H. S. Hwang, J. Bitog, J. I. Yoo, K. S. Kwon, T. H. Ha, and H. T. Kim, 2008. Development of a CFD model to study ventilation efficiency of mechanically ventilated pig house. Journal of The Korean Society of Agricultural Engineers 50(1): 25-37 (in Korean). DOI |
15 | Sherman, M. H., 1990. Tracer-gas techniques for measuring ventilation in a single zone. Building and Environment 25(4): 365-74. DOI |
16 | Song, S. H., I. B. Lee, K. S. Kwon, T. H. Ha, J. Bitog, S. W. Hong, I. H. Seo, O. K. Moon, Y. J. Kim, and E. J. Choi, 2012. Analysis of the disease spread in a livestock building using tracer gas experiment. Journal of the Korean Society of Agricultural Engineers 54(3): 37-45 (in Korean). DOI |
17 | Yoo, J. C., J. B. Lee, and K. H. Jung, 1997. The Study on heat exchanger with in-outlet fan for livestock building. Konkuk univ: MIFAF. |