• Title/Summary/Keyword: Tracer

Search Result 976, Processing Time 0.034 seconds

Two-dimensional Tracer Tests in Natural Rivers Using Radioisotope (방사성 동위원소를 이용한 자연하천의 2차원 추적자 실험)

  • Seo, Il Won;Baek, Kyong Oh;Jeon, Tae Myong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2B
    • /
    • pp.161-170
    • /
    • 2006
  • A tracer test technique using a radioisotope was proposed to investigate pollutant mixing characteristics in rivers. The main advantages of radioisotope as a tracer in field tests are that it can be detected easily, and that its detection range is quite large. Also, using the radioisotope, the amount sorbed by the bed material and the biota may be a minimum. Field tracer tests were conducted at seven different sites in natural rivers with various meandering pattern. Based on the acquired data, the behavior of the tracer cloud in the intermediate-field was examined two-dimensionally, and dispersion coefficients were calculated using several evaluation methods. Results revealed that the tracer cloud was transported skewed to the outer bank and dispersion coefficients in bends were larger than those in straight reaches.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

A C-Programming Learning Model Using a Line Tracer in Discretionary Activity Hours in Elementary Schools (초등학교 재량활동시간에 라인트레이서를 이용한 C프로그래밍 학습모형)

  • Moon, Wae-Shik
    • Journal of The Korean Association of Information Education
    • /
    • v.15 no.4
    • /
    • pp.603-612
    • /
    • 2011
  • This study suggested an educational curriculum(12 class periods) in order for higher level elementary school students to learn programming in discretionary activity hours using a line tracer and evaluated achievement level based on the outcome of learning by class period to assess the possibility of success. As a result, it could confirm that the programming learning using the line tracer was more excellent in creativity than the computer programming learning. In addition, it has been found that the programming learning method using the line tracer had a potential to be successful as a new creative tool that could replace the computer.

  • PDF

The RTD Measurement on a Submerged Bio-Reactor using a Radioisotope Tracer and the RTD Analysis

  • Seungkwon Shin;Kim, Jongbum;Sunghee Jung;Joonha Jin
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.2
    • /
    • pp.210-214
    • /
    • 2003
  • This paper presents a residence time distribution (RTD) measurement method using a radioisotope tracer and the estimation method of RTD model parameters to analyze a submerged bio-reactor. The mathematical RTD models have been investigated to represent the flow behavior and the existence of stagnant regions in the reactor. Knowing the parameters of the RTD model is important for understanding the mixing characteristics of a reactor The radioisotope tracer experiment was carried out by injecting a radioisotope tracer as a pulse into the inlet of the reactor and recording the change of its concentration at the outlet of the reactor to obtain the experimental RTD response. The parameter estimation was performed by the Levenberg-Marquardt optimization algorithm. The proposed scheme allowed the parameter estimation of RTD model suggested by Adler-Hovorka with very low deviations. The estimation procedure is shown to lead to accurate estimation of the RTD parameters and to a good agreement between experimental and simulated response.

현장 규모 biobarrier의 수리학적 특성과 기초 설계

  • 최영화;오재일;왕수균;배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.426-430
    • /
    • 2003
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Effective biobarrier formation is need to assess of hydrogeologic characteristics and to conduct practical operation strategies and design based on this prior to design biobarrier. Thus, in this study, we examined hydrogeologic characteristics in biobarrier construction site. Hydraulic conductivities which calculated from slug test data have shown difference with each well as 1.20$\times$10$^{-3}$ -6.00$\times$10$^{-5}$ cm/sec. Tracer test is a method in which concentration of tracer solution during withdrawal in each well by vacuum extraction system is measured with time. Tracer solution was continuously injected by constant head tank. Measured tracer concentration versus time data were fitted to analytical solution of convection dispersion equation (CDE). The fitting data of CDE to the measured data at each extraction well yielded were 0.61cm/min(pore velocity), 5.38$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.47 1/min and 1.75cm/min(pore velocity), 36.34$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.93 1/min. As a result, we acquired fundamental parameters which need to design biobarrier and operation strategies.

  • PDF

A study on the V-I tracer to abstract the characteristic parameter of solar cell (Solar cell 특성 parameter 추출용 V-I tracer에 관한 연구)

  • Park, Sang-Soo;Lee, Seok-Ju;Seo, Hyo-Ryong;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1966-1967
    • /
    • 2007
  • Photovoltaic(PV) power generation system [1-2] has been extensively studied and watched with keen interest as a clean and renewable power source. So hardware and software studies strongly indicate the feasibility of commercially producing a low cost, user-friendly solar cell curve tracer. Generally, V-I curve tracer indicates only the commonly used solar cell parameters. However, with the conventional V-I curve tracer it is almost impossible to abstract the more detail parameters of solar cell ; A, Rs, and Rsh, which satisfies the user, who aims at the analysis of the development PV power generation system; advanced simulation. In this paper, the proposed method gives us the satisfactory results to abstract the detail parameters of solar cell ; A, Rs, and Rsh

  • PDF

Measurement of Flow Characteristics of Digester Installed Tray Motioned Mixer by Using Radiotracer (방사성추적자를 이용한 수직교반형 소화조의 유동 특성 측정)

  • Moon, Jinho;Park, Jang Guen;Kang, Munhu;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.131-135
    • /
    • 2015
  • The flow characteristics of fluid were measured using radioactive tracer in pilot scale digester with tray motion mixer. In consideration of the detection volume of the detector and the size of the digester, 20 detectors were installed in the digester. The radioactive tracer eluted 8 mCi of $^{68}Ga$ from $^{68}Ge/^{68}Ga$ generator was injected into the digester bottom. After radiotracer injection, the flow pattern was measured on the basis of the initial movement of the tracer until its diffusion completely. Most of tracer moved to the wall along the bottom of the digester, and then rose along the wall. The other tracer moved up along the mixer, and then moved to the wall direction along the surface.

창원지역 화강암의 수리분산 특성

  • 김무진;함세영;황한석;김문수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.187-190
    • /
    • 2001
  • This study is concerned with the hydrodispersive characteristics of granite in Changwon area. A single-well injection/recovery tracer test was conducted to determine longitudinal dispersivity of the granite, using sodium chloride tracer The dispersivity values obtained from the injection phase are 0.48 m (for between PW-1 and OW-3) and 0.72 m (for between PW-1 and OW-4). That obtained from the recovery phase is 0.68 m. The result of the tracer test indicates that the anisotropy and heterogeneity of the granite and the direction of flow.

  • PDF

Thermal environment analysis of greenhouse using Thermo-tracer (Thermo-tracer를 이용한 온실의 열환경 분석)

  • 이석건;이종원;이현우;김란숙
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF