• Title/Summary/Keyword: Toxic gas

Search Result 496, Processing Time 0.032 seconds

Reuse of Hydrogen Sulfide by Ferric Chelate Reaction of Food Waste Anaerobic Digestion Gas, Sulfur Recovery and its Economic Evaluation (킬레이트 착화학반응에 의한 음식물폐기물 혐기소화가스 중 황화수소의 제거와 황회수 및 경제성평가)

  • Park, Young G.;Yang, Youngsun
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.367-374
    • /
    • 2014
  • Several experiments have been done to investigate the removal of hydrogen sulfide ($H_2S$) synthetic gas from biogas streams by means of chemical absorption and chemical reaction with 0.1-1 M Fe/EDTA solution. The roles of Fe/EDTA were studied to enhance the removal efficiency of hydrogen sulfide because of oxidizing by chelate. The motivation of this investigation is first to explore the feasibility of enhancing the toxic gas treatment in the biogas facility. The biogas purification strategy affords many advantages. For instance, the process can be performed under mild environmental conditions and at low temperature, and it removes hydrogen sulfide selectively. The end product of separation is elemental sulfur, which is a stable material that can be easily disposed with minor potential for further pollution. As the Fe-EDTA concentration increased, the conversion rate of hydrogen sulfide increased because of the high stability of Fe-EDTA complex. pH as an important environmental factor was 9.0 for the stability of chemical complex in the oxidation of hydrogen sulfide.

Recovery of Tin with High Purity for Dental Materials from Waste Tin oxide by Reduction and Electro Refining (폐주석산화물로부터 환원공정 및 전해정련을 통한 치과용 고순도 주석 회수)

  • Jung, Hyun-Chol;Kim, Sang-Yeol;Lee, Min-Ho
    • Resources Recycling
    • /
    • v.27 no.6
    • /
    • pp.38-43
    • /
    • 2018
  • In this study, using electro-refining process and methane gas reduction, we performed studying the recovery of tin with high purity from waste tin oxide had used as a electrode rod of ceramic furnace which occurred during glass production process. We recovered the crude tin of 99% purity from a methane gas reduction process and controlled a little amount of impurities. When the electrolytic refining condition was a current density of $60A/dm^2$ and the sulfuric acid concentration of 0.75 mol, 96.8% of recovered tin (99.979% of purity) were recovered during the electrolytic refining. We confirmed that toxic impurities such as Pb, Sb included in electrode rod. could be controlled.

Fabrication of a Cu2ZnSn(S,Se)4 thin film solar cell with 9.24% efficiency from a sputtered metallic precursor by using S and Se pellets

  • Gang, Myeong-Gil;Hong, Chang-U;Yun, Jae-Ho;Gwak, Ji-Hye;An, Seung-Gyu;Mun, Jong-Ha;Kim, Jin-Hyeok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.86.2-86.2
    • /
    • 2015
  • Cu2ZnSn(S,Se)4 thin film solar cells have been fabricated using sputtered Cu/Sn/Zn metallic precursors on Mo coated sodalime glass substrate without using a toxic H2Se and H2S atmosphere. Cu/Sn/Zn metallic precursors with various thicknesses were prepared using DC magnetron sputtering process at room temperature. As-deposited metallic precursors were sulfo-selenized inside a graphite box containing S and Se pellets using rapid thermal processing furnace at various sulfur to selenium (S/Se) compositional ratio. Thin film solar cells were fabricated after sulfo-selenization process using a 65 nm CdS buffer, a 40 nm intrinsic ZnO, a 400 nm Al doped ZnO, and Al/Ni top metal contact. Effects of sulfur to selenium (S/Se) compositional ratio on the microstructure, crystallinity, electrical properties, and cell efficiencies have been studied using X-ray diffraction, Raman spectroscopy, field emission scanning electron microscope, I-V measurement system, solar simulator, quantum efficiency measurement system, and time resolved photoluminescence spectrometer. Our fabricated Cu2ZnSn(S,Se)4 thin film solar cell shows the best conversion efficiency of 9.24 % (Voc : 454.6 mV, Jsc : 32.14 mA/cm2, FF : 63.29 %, and active area : 0.433 cm2), which is the highest efficiency among Cu2ZnSn(S,Se)4 thin film solar cells prepared using sputter deposited metallic precursors and without using a toxic H2Se gas. Details about other experimental results will be discussed during the presentation.

  • PDF

A Study on the Status of Management for Personal Protective Equipments & Fume Hoods in University Research Laboratories (일부 대학 내 연구실험실의 보호구 및 흄후드 관리 실태에 관한 연구)

  • Park, In-Kyu;Lee, Sa-Woo;Jung, Jong-Hyeon;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.229-237
    • /
    • 2014
  • Objectives: This study intends to determine the current status of management of personal protective equipment fume hoods in university laboratories. Methods: A walk-through survey of 402 labs in Gyeongbuk Province and Daegu Metropolitan City were carried out between May 2009 and July 2010. Respectively, 348 and 54 laboratories were examined in Gyeongbuk Province and Daegu. Results: In size, labs serving over 15,000 student made up the majority with 276(66.4%). In terms of major, engineering labs were the highest in number with 100(24.9%). As to personal protective equipment, a gas mask and a dust mask were available in 17.8% and 14.3% of the labs, respectively, but 68.9% of labs were equipped with protective goggles. Meanwhile, only 12.7% of labs had separate protective equipment storage boxes. About 60% of the labs had installed a fume hood, of which the average capture velocity was 0.37 m/sec. Conclusions: For toxic substances, the labs are obliged to provide personal protective equipment in in accordance with the Occupational Safety and Health Act. In addition, the capture velocity of fume hoods must be in strict compliance in order to prevent occupational diseases due to toxic chemicals.

Environmental Fate of Trichlorfon Used to Control Agelastica coerulea B. in Forest by Aerial Application (오리나무 잎벌레(Agelastica coerulea B.) 방제용 살충제 Trichlorfon(Dipterex)의 환경 동태)

  • Lee, Sung-Kyu;Kim, Yong-Hwa;Roh, Jung-Koo
    • Korean Journal of Environmental Agriculture
    • /
    • v.5 no.2
    • /
    • pp.119-129
    • /
    • 1986
  • Disappearence of the trichlorfon (Dipterex) in the forest, following aerial to control Agelastica coerulea B., were studied by sampling deposits on slide glasses, soils, water, and leaves, and analysing with a gas chromatograph equipped with an electron capture detector. By analysing the amount remained on slide glasses, it was shown that the pesticide was adequately sprayed and nearly all deposit was lost in a day. The amount deposited under the tree was about 1/100 of the amount at an exposed site. Concentration of trichlorfon in creek water was 10 to 100 times as high as the acute toxic level to zooplankton for 6 to 24 hours, The rain could recontaminate the stream water up to the toxic level. Loss rate of trichlorfon from soils showed variations by sampling sites and was generally slower than from slide glasses. Amount deposited on leaves were less than the calculated or expected amount. The loss from leaves were similar to that from soil.

  • PDF

Toxicity Evaluation of Effluent Gases from a Residental Fire by Rats (연립 주택 화재시 유독가스 방출 특성과 Rats를 이용한 독성평가)

  • Kim, Hong;Kang, Young-Goo;Kim, Dong-Hyun;Jung, Ki-Chang;Lee, Chang-Seop;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.12-15
    • /
    • 2002
  • It has long been recognized that exposure to fire-induced toxic gases is a fatal hazard confront-ing people in fires. In this study, an indoor fire experiment was conducted in an unoccupied residential building located in An-san city, Kyoung-gi province, and the composition of effluent gases, which include CO, $CO_2$, $O_2$, $SO_2$, NO and $NO_2$, were measured by a gas analyzer. A group of lab rats were exposed to the toxic gases released from fire, and the blood samples of the rats were gathered every 2 minutes. A toxicity evaluation was conducted by analyzing the concentrations of Glucose, AST(GOT), ALT(GPT), CBC Count and CO(carboxy)-Hb in the blood samples. Shown from the analysis is the does-response relationship between the CO concentration that rats were exposed to and the CO-Hb concentration in rat blood.

Encapsulation of ZnSe Quantum Dots within Silica by Water-in-oil Microemulsions (마이크로에멀전을 이용한 실리카에 담지된 ZnSe 양자점 제조)

  • Lee, Areum;Kim, Ji Hyeon;Yoo, In Sang;Park, Sang Joon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.328-331
    • /
    • 2011
  • ZnSe quantum dots (QDs) were prepared by employing water-containing Dioctyl sodium sulfosuccinate (AOT) reversed micelles (microemulsions) and the silica-encapsulated ZnSe QDs were obtained by a direct injection of tetraethyl orthosilicate (TEOS) into the microemulsion system. When the QDs were coated by silica, well-defined spherical shapes were formed and the average size of the QDs was near 7 nm. In addition, the photoluminescence (PL) efficiency of the QDs was reduced from 8.0 to 1.1% as they were encapsulated by silica. However, the solid layers of the silica-encapsulated ZnSe QDs on gold surfaces showed the excellent photostability. In particular, they are cadmium free and thus, less toxic. Moreover, the present method does not require a hot reaction temperature or extremely toxic H2Se gas as a Se precursor. Accordingly, the method can be a safer and more economical process for producing silica-encapsulated ZnSe QDs, which may be a potential media for biosensors.

A Study on the Safety Improvement in a Venting System from the HCl Release Accident of a Petrochemical Company (석유화학공장의 염화수소 누출사고를 통한 대기벤트 시스템의 안전성 향상 방안)

  • Ma, Byung-Chol;Lee, Keun-Won;Im, Ji-Pyo;Kim, Young-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.38-43
    • /
    • 2012
  • The purpose of this study is to carry out the consequence analysis of an accident related to the release of Hydrogen chloride occurred in a petrochemical company in Korea and suggest the measures to prevent similar accidents from happening again. The total amount released through the safety valve of HCl Column was calculated based on the rated capacity of the safety valve, the ideal gas equation and mechanical energy balance, respectively. As a result of the calculation, we found that the amount of HCl released through the safety valve was at least 76.8 kg. Also, we predicted the dispersion concentration at the position of the injured workers(more than 350 m away from the accident location) using simulation programs such as PHAST. The results of ALOHA and K-CARM are 304 ppm and 1,700 ppm respectively. However, PHAST calculation indicated that the concentration is less than l ppm. From these results, we can understand that workers were injured by HCl gas released from the safe valve and the concentration of gas might be less than 1 ppm. Also, it is important for toxic gases such as HCl to be vented safely to the atmosphere after scrubbing.

Development of a monolithic apparatus for degasing aluminum continuous casting molten metal (알루미늄 연속주조 용탕의 탈 가스 일체화 장치 개발)

  • 이용중;김태원;김기대;류재엽;이형우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.145-149
    • /
    • 2004
  • It is necessary for managing a perfect process for degasing aluminum molten metal according to the increase of a grade of aluminum and its alloy products. There are some methods that have been used to manage a degasing process in recent years, such as an injection method that uses aluminum molten metal powder and chemicals supplier and input method that supplies argon and nitrogen, or chlorine gas by using a gas blow-tube. However, these methods show some problems, and it shows that it is a difficult process to handle. pollution due to the producing a lot of toxic gases like chlorine and fluoride gas. irregular effects, and lowering work efficiency due to the excessive processing time. The problems that are the most fatal are the producing a lot of sludge due to the reaction of aluminum molten metal with chemicals. loss of metals, and decreasing the life of refractory materials. In order to solve these problems. this paper develops a technology that is related to aluminum continuous casting molten metal and monolithic degasing apparatus. A degasing apparatus developed in this study improved the exist ing methods and prevented environmental pollution wi th smokeless. odor less, and harmlessness by using a new method that applies argon and nitrogen gas in which the methods used in the West and Japan are eliminated. The developed method can significantly reduce product faults that are caused by the production of gas and oxidation because it uses a preprocessed molten metal with chemicals. In addition. the amount of the produced sludge can also be reduced by 60-80% maximum compared with the existing methods. Then. it makes it possible to minimize the loss of metals. Moreover. the molten metal processing and settling time is also shortened by comparing it with the existing methods that are applied by using chemicals. In addition, it does much to improve the workers' health, safety and environment because there is no pollution. The improvement of productivity and prevent ion effects of disaster from the results of the development can be summarized as follows. It will contribute to the process rationalization because it does not have any unnecessary processes that the molten metal will be moved to an agitator by using a ladle and returned to process for degasing like the existing process due to the monolithic configuration. There are no floating impurities due to the oxidation caused by the contact with the air as same as the existing process. In addition. it can protect the blending of precipitation impurities. Because it has a monolithic configuration. it can avoid the use of additional energy to compensate the temperature decreasing about 60t that is caused by the moving of molten metal. It is not necessary to invest an extra facilities in order to discharge the gas generated from a degasing process by using an agitator. The working environment can be improved by the hospitable air in the factory because the molten metal is almost not exposed in the interior of the area.

  • PDF

The Methodology for Prediction and Control of Hazardous Chlorine Gas Flow Releases as Meteorological Data (기상조건에 따른 유해독성염소가스의 가상흐름누출에 관한 예측 및 제어론)

  • Kim, Jong-Shik;Park, Jong-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1155-1160
    • /
    • 1999
  • The screening methodology modeling, dispersion modeling procedures for continuous and instantaneous releases of the gas phase flow from the storage tank and pressure relief valve were considered. This study was performed to develop the screening methodology for prediction and control of hazardous/toxic gas releases by estimating the 1-hr average maximum ground-level concentration of $Cl_2$ gas vs. downwind distance by incorporating source term model including the general/physical properties of released material and release mode of the $Cl_2$ storage tank of the chemical plant facilities, dispersion model, and meteorological/topographical data into the TSCREEN model. As the results of the study, it was found that dispersion modes of the dense gas were affected by the state of the released material, the released conditions, physical-chemical properties of released material, and the released modes (continuous and instantaneous releases), and especially largely affected by initial (depressurized) density of the released material and release emission rate as well as the wind velocity. Especially, this study was considered to release hazardous material as meteorological data. It was thought that this screening methodology can be useful as a preliminary guideline for application of the refined analysis model by developing the generic sliding scale methodology for various senarios selected.

  • PDF