The yaw gearbox is a key device in a wind power generator that improves power generation efficiency by rotating hundreds of tons (400 to 600 tons) of nacelle so that the blade reaches 90 degrees in the wind direction. Recently, installation sites have been advancing from land to sea as they have become super-large at (8-12) MW to increase the economic feasibility of wind power generators and utilize excellent wind resources, and the target life of large wind power generators is 25 to 30 years. The yaw gearbox of 6 to 12 sets is installed in a very complex place inside the nacelle on the tower with parallels, and it is important to secure the reliability of the yaw gearbox because if a failure occurs after installation, it costs tens to hundreds of times the price of a new product to restore. In this study, equivalent loads were calculated by analyzing failure mode and field data, accelerated life test conditions were established, and a test device was constructed to perform the accelerated life tests and performance tests to ensure the reliability of the gearbox.
Floating offshore wind turbines (FOWTs) have been developed to overcome large water depths and leverage the abundant wind resource in deep seas. However, wind-wave misalignment can occur depending on the weather conditions, and most megawatt (MW)-class turbines are horizontal-axis wind turbines subjected to yaw errors. Therefore, the power performance and dynamic response of super-large FOWTs exposed simultaneously to these external conditions must be analyzed. In this study, several scenarios combining wind-wave misalignment and yaw error were considered. The IEA 15 MW reference FOWT (v1.1.2) and OpenFAST (v3.4.1) were used to perform numerical simulations. The results show that the power performance was affected more significantly by the yaw error; therefore, the generator power reduction and variability increased significantly. However, the dynamic response was affected more significantly by the wind-wave misalignment increased; thus, the change in the platform 6-DOF and tower loads (top and base) increased significantly. These results can be facilitate improvements to the power performance and structural integrity of FOWTs during the design process.
Although wind turbines have obtained type certification according to international standards and are released to the market, they cannot be regarded as design evaluations that consider site characteristics. Therefore, it is necessary to study the site-specific load analysis method based on the meteorological data measured at the candidate site. In this study, site-specific load calculation was performed based on the meteorological data from the Jeju Haengwon mast. Analysis results were compared and analyzed with the results calculated by IEC design Class (IIA). For the fatigue loads at the blade root and tower base, the site-specific condition was lower than the IEC IIA, but in the case of the ultimate load, the site-specific condition showed higher results in some design load cases (DLCs). Selecting a wind turbine suitable for a site through load evaluation considering site conditions can prevent the reduction of operation and maintenance (O&M) costs and the power loss caused by downtime. Finally, it is expected to contribute to the project's levelized cost of energy (LCOE) reduction.
In this study, the resonant motion of a floating offshore wind system due to negative damping was mitigated by peak shaving algorithms of the NREL ROSCO controller, and the decreased gains of the blade pitch controller by the gain detuning method for the floating system was increased to the gains of onshore baseline controller to improve the power performance of the turbine. To check the performance of the controller, the dynamic responses between the existing gain-detuned pitch controller and the ROSCO controller with peak shaving control for an OC4 floating offshore wind system were compared. As a result of DLC1.1 at near-rated wind speed, when peak shaving was applied, the average generator power decreased by 1.9%, but it was confirmed that the standard deviation was reduced and stability was improved with fast pitch regulation. In addition, since peak shaving reduces the maximum thrust of the rotor, was confirmed that not only are the loads of the blades and tower reduced, but the surge motion of the floater is also reduced, and the tension of the mooring lines is reduced.
오늘날 석유화학, 정밀화학, 대기오염 방지산업 등에서 증류, 흡수, 추출, 탈거 등 물질분리 단위공정으로 주로 충전탑을 사용해 왔다. 충전탑은 가스-액체, 가스-가스 시스템에서의 물질들과의 접촉에 의해 운전되어 진다. 이러한 충전탑은 낮은 압력손실, 경제적 효율, 고온성 액체물질 적용, 유지보수 용이, 유해가스 처리 등의 운영에서 장점들을 가진다. 충전탑의 성능은 충진물을 통해 가스와 액체를 고르게 분산함으로써 우수한 성능을 보이며, 이는 충전탑 설계에 있어 중요한 인자로 고려되어진다. 본 실험에서는 충진물에 대한 액체부하 및 가스용량인자에 따른 건조압력손실, 수력학적 압력손실, 액체함량 변화에 대한 기하학적 특성에 대하여 연구하였다. 결과로부터 설계인자와 운전조건 등의 유해가스 처리에 필요한 인자를 도출하였다. 임의 충진물인 raschig super-ring에 대한 건조압력손실을 측정한 결과, 가스용량인자가 증가할수록 일정하게 선형적으로 증가하였고, 가스용량인자가 0.630 ~ 3.448 kg-1/2 m-1/2 S-1에서 건조압력손실은 1.892 ~ 47.312 mmH2O m-1로 기존 산업현장에서 보편적으로 사용되는 35 mm pall-ring보다도 낮은 압력손실을 보였다. 그리고 raschig super-ring에 대한 수력학적 압력손실을 측정한 결과, 고유 액체부하에 대하여 가스용량인자가 증가할수록 압력손실도 함께 증가함을 확인하였고, 액체부하 변화에 따른 가스용량인자가 1.855 ~ 2.323 kg-1/2 m-1/2 S-1으로 20% 증가할 때, 압력손실은 약 17% 증가하는 것으로 나타났다. 마지막으로, 충진물 체적에 관한 액체함량은 가스용량인자에 의존된 액체부하 매개변수로서 액체부하 변화에 따른 가스용량인자 약 3.84 kg-1/2 m-1/2 S-1까지는 거의 일정한 액체함량을 보였으나, 그 이상에서는 급격하게 증가하였다.
본 논문에서는 국내 몇몇 시험현장에서 수행한 총 54회 단일앵커시험과 4회 실규모 앵커기초에 대한 결과를 제시하였다. 시험결과, 암반앵커의 인발에 대한 파괴메커니즘은 암종 및 암질, 근입깊이, 불연속면의 특성, 텐던의 강도 등에 영향을 받는 것으로 나타났다. 불량한 암반내 얕은 앵커의 경우(정착심도 1.0m 이하) 대부분 그라우트-암반 부착파괴로 나타났으나 이러한 경우에도 깊이를 증가시키면 암반파괴를 유도할 수 있다. 반면에, 얕은 앵커기초라 하더라도 암반상태가 좋으면 부착파괴가 아닌 암반파괴의 형태를 보인다. 한편 실내부착강도 시험결과는 표면부터 진행성파괴가 나타나며 점차 아래로 전파된다. 이때 측정된 텐던-그라우트 부착강도는 그라우트 일축압축강도의 약 $18{\sim}25%$로 나타났으며, 방식 쉬이스로 인한 부착강도의 감소는 보이지 않았다. 연구결과로부터 암반앵커시스템의 인발지지력을 지배하는 주요 파라메터를 결정하고 적용 암반의 분류기준을 제시하였으며, 최종적으로 인발에 대한 암반앵커기초의 지지력을 평가할 수 있는 간편화된 절차를 제안하였다.
잭업드릴링 리그는 해양 석유와 가스 탐사 산업에서 널리 사용되는 모바일 해양 플랫폼이다. 그것은 시추 및 생산을 위한 캔틸레버 시추 장치가 있는 독립적인 3개의 다리가 있는 자체 승강식 장치이다. 전형적인 잭업리그는 삼각형 선체, 타워형 데릭, 캔틸레버, 잭케이스, 거주구와 다리로 구성되며 여기에는 스퍼드캔 구조, 개방형 트러스, X-교차 구조로 구성된다. 일반적으로 잭업리그는 수심 130m~170m에서만 운용이 되고 있다. 최근 들어 개발 유정이 심해로 이동하면서, 깊은 수심과 가혹한 환경조건을 만족해야 한다. 리그의 작업 상태에서 모든 정적, 동적 하중은 레그(Leg)를 통해서 지탱되는 특징이 있다. 이러한 리그의 중요한 이슈는 순간적으로 큰 충격에너지를 발생시키는 충돌에 대한 레그의 안전성이다. 본 연구에서는 LS-Dyna 프로그램을 이용하여 DNV 선급에서 규정하고 있는 충돌에너지 35MJ 요구사항에 대한 수치해석 및 검증을 수행하였다. 충돌 선박은 배수량 7,500톤 작업 지원선을 사용하였고, 5가지 충돌조건을 선정하였다. 해석결과로부터 모든 충돌조건은 선급 기준을 만족하지 못한다. 코드 방향 충돌조건은 충돌에너지 15MJ, 브레이스 충돌조건은 6MJ이 합리적이다. 따라서 충돌시나리오에 따른 합리적인 충돌에너지 기준의 제정이 필요로 하다.
The Ting Kau Bridge in Hong Kong is a cable-stayed bridge comprising two main spans and two side spans. The bridge deck is supported by three towers, an end pier and an abutment. Each of the three towers consists of a single reinforced concrete mast strengthened by transverse cables and struts. The bridge deck is supported by four inclined planes of cables emanating from anchorages at the tower tops. In view of the heavy traffic on the bridge, and threats from typhoons and earthquakes originated in areas nearby, the dynamic behaviour of long-span cable-supported bridges in the region is always an important consideration in their design. Baseline finite element models of various levels of sophistication have been built not only to match the bridge geometry and cable forces specified on the as-constructed drawings but also to be calibrated using the vibration measurement data captured by the Wind and Structural Health Monitoring System. This paper further describes the analysis of axle loading data, as well as the generation of random axle loads and simulation of vibrations of the bridge using the finite element models. Various factors affecting the vehicular loading on the bridge will also be examined.
Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
Steel and Composite Structures
/
제15권1호
/
pp.103-130
/
2013
Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.
이 논문에서는 무베어링 로터의 동특성을 비회전 강성 및 진동수 측정 시험과 회전 훨타워 시험을 통해 살펴보았다. 무베어링 로터의 주요 구성품인 블레이드, 유연보, 토크튜브에 대해 강성 및 고유진동수를 측정하여 해석을 위한 물성치를 확보하였고, 훨타워 시험 전에 댐퍼와 스너버를 장착한 무베어링 로터를 조립하여 지상에서 하중이 부가되는 조건하에 기능시험을 수행하여 로터 구성품간의 간섭 여부, 기구학적 거동 등을 확인하였다. 4개의 블레이드를 가지고 회전반경이 5.82m인 무베어링 로터의 회전 동특성시험을 회전면 높이가 9.65m인 훨타워에서 수행하였다. 정지비행성능을 확인하기 위해 추력과 사용동력을 측정하였으며, 회전시 블레이드의 고유진동수 및 감쇠를 측정하기 위해 유압 가진기를 통하여 사이클릭 가진을 하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.