• 제목/요약/키워드: Total temperature measurement

검색결과 263건 처리시간 0.028초

자동차 배기가스 측정을 위한 매연프로브 효율 개선에 관한 연구 (Improvement of Soot Probe Efficiency for Automotive Emission Measurement)

  • 채일석;김상유;김재열
    • 한국기계가공학회지
    • /
    • 제18권8호
    • /
    • pp.74-81
    • /
    • 2019
  • Cars are inspected in the transport sector for their ability to achieve the greenhouse gas reduction targets. A vehicle (automobile) inspection broadly consists of regular and total checks, and both the safety level and the amount of exhaust gas are checked simultaneously during a vehicle inspection. This study deals with the efficiency of a soot probe to measure soot emissions from diesel vehicles. When the vehicle exhaust gas measurement is performed, there may be a difference between the exhaust gas temperature and the soot suction amount because of the different shape and angle of the exhaust port for each vehicle type. This may result in some incidents where the correct inspection nonconforming vehicle is not selected. Therefore, in this study, the shape of the probe was improved to increase the soot measurement efficiency under the condition of the exhaust pipe angle change.

과소팽창된 충돌제트에 의한 단열벽면 온도 측정 (Measurement of Adiabatic Wall Temperature on an Impinging Surface by Under-expanded Jet)

  • 유만선;이장우;김병기;조형희;황기영;배주찬
    • 한국항공우주학회지
    • /
    • 제33권4호
    • /
    • pp.79-84
    • /
    • 2005
  • 평판 표면에 충돌하는 축대칭, 과소팽창 제트에 대한 실험적 연구가 수행되어졌으며, 벽압력 및 단열 벽온도 분포가 자세히 측정되어졌다. 벽온도 분포 결과에 대한 설명을 위하여 자유제트 내에서의 전온도 값을 전온도 탐침을 사용하여 측정하였다. 본 연구에서 실험 변수로는 과소팽창비와 노즐-평판간 거리가 고려되었다. 노즐-평판 간 거리에 따라 제트 경계 및 충돌면에서의 에너지 박리에 의해 서로 다른 형태의 단열 벽온도 분포가 나타났으며, 과소팽창비가 큰 경우, 중심영역에서의 저온 유체 입자의 고립효과로 정체점의 회복계수가 크게 낮아지는 현상 또한 관찰되었다.

시설원예 태양열 시스템의 효율적 이용과 자동화 장치개발(2) -지중가온에 의한 오이 생육 및 수량성 향상에 관한 연구- (A Development of Automation system and a way to use Solar Energy System Efficiently in Greenhouse(2) - Study on improvement of growth and yield of a cucumber in soil heating -)

  • 김진현;오중열;구건효;김태욱
    • 생물환경조절학회지
    • /
    • 제7권1호
    • /
    • pp.25-33
    • /
    • 1998
  • 겨울철 오이 시설재배에서 태양열 시스템을 이용한 지중가온의 효과를 구명하고자 지중 40 cm에 15 mm의 PPC파이프를 130 cm이랑 에 4열 매설한 후 지중 20 cm의 지온을 $22~23^{\circ}C$로 설정한 후 1996년 11월 7일부터 1997년 1월 30일까지 일정한 온도로 유지, 관리하여 무가온구와 가온구의 지상부, 지하부 및 수량을 비교시험한 결과는 다음과 같다 1) 지중가온에 의한 지온확보는 가온구는 15~20 cm에서 $22^{\circ}C$ 정도의 평균온도를 확보할 수 있었고, 무가온구는 평균 $17~18^{\circ}C$ 정도였다 2) 정식 30일 정도에서 초기생육은 가온구가 초장, 경경, 엽수, 엽면적 등 모두 증가하였으며 특히 초장 27%, 엽수 51%, 엽면적은 150% 정도 증가하였다. 또 지상부 평균 증가율도 관행대비 가온구 증가율이 117% 정도였다. 3) 가온구의 지하부 뿌리의 생장성이 관행구에 비하여 평균 56% 정도 증가하였다 4) 과수의 수량면에서도 총과수가 무가온구 313개, 가온구 614개로 가온구가 196% 정도 증수되었다.

  • PDF

대기 중 수은의 지역적 분포특성에 대한 비교연구-한반도의 도심과 산악지역을 중심으로 (Regional Distribution Characteristics of Total Gaseous Mercury in Air-Measurements from Urban and Mountainous Sites in Korea)

  • 김민영;김기현
    • 한국대기환경학회지
    • /
    • 제17권1호
    • /
    • pp.39-50
    • /
    • 2001
  • The spatial distribution characteristics of airborbe mercury(Hg) were investigated used its concentration data from six measurement sites selected to represent:(1) three terminal sites with heavy traffic loads in urban area, (2) one urban residential site and (3) two mountainous sites in Korea. The measurement data obtained during September 1997 through May 1998 indicated that the mean concentration of Hg from different study sites were comparably high with the mean values spanning from 5-9ng./㎥. The concentration from all those sites were systmatically high compared to those of most background sites around world or to other Korean sites investigaed previously. When results of correlation analysis between Hg and relevant parameters were compared among different study sites. temperature was most frequently found out to be in strong correlation with Hg concentrations. Results of factor analysis also indicated that Hg concentrations could be affected simultaneously by th factors affecting such parameters as ozone, temperature, ozone, carbon monoxide, and PM. The findings of enhanced Hg levels from Ji-Ri Mountain relative to terminal site suggest that is distributions may be rather homogeneous not enough to clearly distinguish areal differences and the associated source signatures between urban and rural area. The existence of systmatically high concentrations from all investigated sites also indicate that the impact of its source processes should be quite ubiquitous, while highly variable in relatively long term scale.

  • PDF

원형 석굴암 상부구조의 장마철 결로 및 열전달 현상의 실험적 연구 (Experimental investigation of dew formation and heat transfer in the original upper structure of Sokkuram grotto)

  • 이진기;송태호
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.588-597
    • /
    • 1999
  • Sokkuram grotto, a UNESCO cultural heritage in Kyongju Korea, was originally covered with crushed rocks over its dome with ventilating holes. The grotto was perfectly preserved for more than 12 centuries until the upper structure was replaced with a concrete dome in the early 20th century to protect from total collapse. Since then, heavy dew formed on the granite surface to seriously damage the sculptures until it was further remodeled with air-conditioning facilities in the 60s. It is considered that the original upper porous structure had a dehumidifying capability. This research is made to unveil the dehumidifying mechanism of the rock layer during the rainy season in that area. A rock layer and a concrete layer are tested in a temperature/humidity-controlled room. No dew formation is observed for the two specimen for continued sunny days or continued rainy days. However, heavy dew formed on the concrete surface for a sunny day after long rainy days. It is thought that the sun evaporates water on the ground and dew is formed at the surface as the highly humid air touches the yet cold concrete. On the contrary, no dew formation is observed for the rock layer at any time. Even in the above worst situation, air flows downward through the cool rock layer and moisture is removed before reaching inside. Temperature measurement, flow visualization, observation of dew formation and measurement of air velocity are made to verify the mechanisms.

  • PDF

Estimation of BOD in wastewater treatment plant by using different ANN algorithms

  • BAKI, Osman Tugrul;ARAS, Egemen
    • Membrane and Water Treatment
    • /
    • 제9권6호
    • /
    • pp.455-462
    • /
    • 2018
  • The measurement and monitoring of the biochemical oxygen demand (BOD) play an important role in the planning and operation of wastewater treatment plants. The most basic method for determining biochemical oxygen demand is direct measurement. However, this method is both expensive and takes a long time. A five-day period is required to determine the biochemical oxygen demand. This study has been carried out in a wastewater treatment plant in Turkey (Hurma WWTP) in order to estimate the biochemical oxygen demand a shorter time and with a lower cost. Estimation was performed using artificial neural network (ANN) method. There are three different methods in the training of artificial neural networks, respectively, multi-layered (ML-ANN), teaching learning based algorithm (TLBO-ANN) and artificial bee colony algorithm (ABC-ANN). The input flow (Q), wastewater temperature (t), pH, chemical oxygen demand (COD), suspended sediment (SS), total phosphorus (tP), total nitrogen (tN), and electrical conductivity of wastewater (EC) are used as the input parameters to estimate the BOD. The root mean squared error (RMSE) and the mean absolute error (MAE) values were used in evaluating performance criteria for each model. As a result of the general evaluation, the ML-ANN method provided the best estimation results both training and test series with 0.8924 and 0.8442 determination coefficient, respectively.

열광학적 분석 프로토콜에 의한 유기탄소와 원소탄소 측정값 비교 (Comparison of OC and EC Measurement Results Determined by Thermal-optical Analysis Protocols)

  • 김효선;정진상;이진홍;이상일
    • 한국대기환경학회지
    • /
    • 제31권5호
    • /
    • pp.449-460
    • /
    • 2015
  • Carbonaceous aerosol is generally classified into OC (organic carbon) and EC (elemental carbon) by thermal optical analysis. Both NIOSH (National institute of occupational safety and health) with high temperature (HighT) and IMPROVE-A (Interagency monitoring of protected visual environments) with low temperature (LowT) protocols are widely used. In this study, both protocols were applied for ambient $PM_{2.5}$ samples (Daejeon, Korea) in order to underpin differences in OC and EC measurements. An excellent agreement between NIOSH and IMPROVE-A protocol was observed for TC (total carbon). However, significant differences between OC and EC appeared and the differences were larger for EC than OC. The main differences between two protocols are temperature profile and charring correction method. For the same charring correction method, HighT_OC was 10% higher than LowT_ OC, while HighT_EC was 15% and 33% lower than LowT_EC for TOT (thermal-optical transmittance) and TOR (thermal-optical reflectance), respectively. This difference may be caused by the temperature of OC4 in He step and possibly difference in POC (pryorilized OC) formation. For the same temperature profile, OC by TOT was about 26% higher than that by TOR. In contrast, EC by TOT was about 50% lower than that by TOR. POC was also dependent on both temperature profile and the charring correction method, showing much distinctive differences for the charring correction method (i.e., POC by TOT to POC by TOR ratio is about 2). This difference might be caused by different characteristics between transmittance and reflectance for monitoring POC formation within filters. Results from this study showed that OC and EC depends on applied analysis protocol as shown other studies. Because of the nature of the thermal optical analysis, it may not be possible to have an absolute standard analysis protocol that is applicable for any ambient $PM_{2.5}$. Nevertheless, in order to provide consistent measurement results for scientists and policy makers, future studies should focus on developing a harmonized standard analysis protocol that is suitable for a specific air domain and minimizes variations in OC and EC measurement results. In addition, future elaborate studies are required to find and understand the causes of the differences.

장기 안정성을 고려한 경질유 유량표준장치 불확도 평가 (Long Term Stability of Uncertainty Analysis of Light Oil Elow Standard System)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제29권10호
    • /
    • pp.1130-1138
    • /
    • 2005
  • A national standard system for the petroleum field has been developed to calibrate and test the oil flow meters in Korea. The operating system and the uncertainty of the system were evaluated by the peer reviewers of foreign national metrology institutes in 2002. Since the characteristics of the system might be changed by time, the uncertainty of the system is reevaluated with the consideration of the long term stability of the system. It is found that the system has a relative expanded uncertainty of 0.048 $\%$ in the range of $15\~120\;m^3/h$. According to the uncertainty budget, the uncertainties of the fluid density and the final mass measurement, which are temperature dependent, contribute about $94\%$ of the total uncertainty in the oil flow standard system

다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작 (Manufacture of Custom IC and System for Multi-channel Biotelemeter)

  • 서희돈;박종대
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF

얼굴생김새와 식사행동과의 관련성 (Relationship Between Morphologic measurement of Facial Feature and Eating Behavior During a Meal)

  • 김경업;김석영
    • 한국식생활문화학회지
    • /
    • 제16권2호
    • /
    • pp.109-117
    • /
    • 2001
  • Judging from the studies carried out by Dr. Jo, Yong Jin on the Koreans' faces, Koreans divided into two constitutions according to their facial features and heritages. The one population is the Northern lineage whose ancestor migrated from Siberia in ice age. In order to survive in cold climate, they have developed a high level of metabolic heat production. Cold adaptation for preventing heat loss results in a reduction in the facial surface area with small eyes, nose and lips. The other population is the Southern lineage who is the descent of native in Korean peninsular. They have big eyes with double edged eyelids, broad nose and thick lips. It is generally believed that both genetic and environmetal factors influence eating behaviors. Although we can't recognized their heritage that may contribute to the metabolism and eating behavior, we commonly recognize their physiological heritage acceding to their facial features. In order to investigate the relationship among the size and shape of facial feature, the eating behavior, anthropometric measurement in female college students, the eating behaviors was measured during an instant-noodle lunch eaten in a laboratory setting at the ambient temperature of $23^{\circ}C$. The anterior surface area of left eye and length of right eye were positively correlated with the difference between the peak postprandial and the meal-start core temperature. The surface area of lower lip also negatively correlated with the meal-start core temperature and meal duration. In addition, the total lips' area was positively correlated with the difference between the peak postprandial and the meal-start core temperature and negatively correlated with the meal duration. However anthropometric measurements were not related with the size of facial features.

  • PDF