• Title/Summary/Keyword: Total suspended particulate

Search Result 149, Processing Time 0.022 seconds

An Application of $^{13}C$ Tracer for the Determination of Primary Productivity and Fatty Acid Production Rate in Shingu Reservoir (신구저수지의 1차 생산 및 지방산 생성속도 결정을 위한 $^{13}C$ 추적자 활용 연구)

  • Lee, Yeon-Jung;Kim, Min-Seob;Shin, Kyung-Hoon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.21-26
    • /
    • 2008
  • The in situ incubation experiment was carried out using $^{13}C$ tracer to determine primary productivity and fatty acid production rate in the shallow, eutrophic Shingu reservoir on 4th July. Particulate organic matter (POM) accounted for 76% in suspended particulate matter (SPM), and average concentration of chlorophyll-${\alpha}$ was $89{\mu}g\;L^{-1}$ in the euphotic layer. Total amount of chlorophyll-${\alpha}$ (Chl-${alpha}$), primary productivity and Chl-${alpha}$ specific productivity in euphotic layer were 112 mg Chl-${alpha}m^{-2}$, 3.53 g C $m^{-2}\;d^{-1}$, 32mg C mg Chl-${\alpha}^{-1}\;d^{-1}$, respectively. The fatty acid composition in newly produced organic matter and suspended organic matter didn't show any significant difference, demonstrating that autochthonous organic matter should be a major source of POM pool. In addition, the fatty acids of bacterial origin were increased through extracellular release of newly photosynthesized DOC, and closely coupled with bacterial assimilation. This result suggests that organic carbon should be actively cycled through the microbial loop in Shingu reservoir in summer.

Modeling Oyster Populations Dynamics -I. Effect of Available Food on Growth of the Pacific Oyster Crassostrea gigas in Goseong Bay, Korea- (수치모델을 이용한 고성만 양식 참굴의 연구 -I. 먹이가 참굴의 성장에 미치는 영향-)

  • Oh Kyung Hee;Pang Ig Chan;HOFMANN Eileen E.;Kim Yoon;Kim Sung Yeon;Park Yoon Jung;Choi Kwang Sik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.4
    • /
    • pp.327-335
    • /
    • 2002
  • Effects of available food on growth of commercially cultured Pacific oysters, Crassostrea gigas in Goseong Bay on the south coast were studied using a numerical model. levels of total protein, carbohydrate and lipid in particulate organic matter in the water column as well as chlorophyll a concentration were determined for estimating total available food for oyster growth. Environmental parameters including water temperature, salinity and total suspended solid were also monitored for the model. Oyster growth was also monitored by means of measuring shell length and tissue wet weight increase on a monthly basis. Simulation results from the numerical model indicated that chlorophyll a is not a good representative of available food for the oysters in Goseong Bay. In contrast, available food in the water column measured by filtration of the organic particles and analyzed in terms of total lipids, carbohydrates and protein was well matched with simulated oyster growth in the Bay which is similar to observed growth. The model also suggested that oysters have relatively low retention efficiency of $50\%$ or less. This result indicates that oysters in the bay utilize only a part of food particle available in the water column, as reported in other studies.

The influence on air quality of the surroundings by the facility of the district heating (집단 에너지 시설에 의한 주변 대기질 영향)

  • 연익준;주소영;이민희;손종렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.

Associations between Airborne Manganese and Blood Manganese in the Korean General Population according to KNHANES 2008-2009 (한국인의 혈중 망간농도와 공기중 망간농도의 관련성)

  • Jung, Kyung Sick;Lee, Jong Dae;Kim, Yong Bae
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1589-1598
    • /
    • 2013
  • The objective of this study was to evaluate associations between airborne manganese and blood manganese in a general population of South Korean adults. The concentrations of airborne manganese in total suspended particulate (TSP) were calculated from data obtained from ambient air-monitoring stations (AAMSs) located in South Korea. Blood manganese data obtained Korean National Health and Nutrition Examination Survey (KNHANES) using a rolling sampling design involving a complex, stratified, multistage, probability cluster survey of a representative sample of the non-institutionalized civilian population of South Korea. Airborne manganese geometric means was 46.10 $ng/m^3$, blood manganese geometric means were 1.19 ${\mu}g/d{\ell}$ for male and 1.40 ${\mu}g/d{\ell}$ for female. In multiple linear regression analysis of log transformed blood manganeseas a continuous variable on airborne manganese, after adjusting for covariates including gender, age, job, smoking and drinking status, education level, BMI (body mass index). Airborne manganese was positively associated with blood manganese with statistical significance. The present study confirms that airborne manganese is a possible contributor to the increase of blood manganese in the adult general population.

Health Risk of Airborne Complex Mixtures Based on their Mutagenicity (대기중 복합물질의 돌연변이원성과 인체 위해도)

  • Park, Seong-Eun;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.269-278
    • /
    • 1996
  • Airborne suspended particulates were collected by an Andersen high volume air sampler in a traffic area of Seoul from September 1990 to August 1991. Origanic matter extracted from particulates, their fractions, namely acidic, basic, neutral and carcinogenic subfractions (PAHs, nitroarenes) in neutral fractions were assayed for mutagenicity on TA98, TA100 and TA98NR deficient Salmonella strains, use of the pre-incubation method. The relative contribution to total mutanenicity of organic matters was highest in neutral fraction and was lowest in basic fraction. Among subfractions, that of neutral fraction was higher nitroarenes subfraction compared to PAHs subfraction. While the carcinogenic effect of benzo[a]pyrene was calculated as 0.96 persons/million persons based on unit risk estimates by extrapolation method, life time excess cancer risk estimate of EOM, neutral, PAH fraction based on their mutagenicity was calculated as 52, 42, 3.8 persons/million persons, respectively. These findings indicate that the mutagenic hazard of the partciculate, air organic complex mixture, may be dependent upon the mutagen composition in the particulate and interactions each of them. Therfore, health risk from air organic complex mixtures based on mutagenicity might be useful indicator for evaluation of actual risk.

  • PDF

Relationship between Pollutant and Influence Factors in Highway runoff (강우시 고속도로 노면 유출 오염부하 발생 특성 분석)

  • Kang, Hee-Man;Lee, Doo-Jin;Bae, Woo-Keun;Kang, Hye-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.47-54
    • /
    • 2012
  • This study analyzed influence factors and the correlation among pollutants which affect occurrence of leaked pollution based on the long-term runoff flow and water quality investigation results to understand the characteristics of highway rainfall runoff pollution load. According to the result of correlation analysis on TSS (Total Suspended Solid) concentration, anteceded dry days, rainfall intensity, traffic volume and etc. as major influence factors of highway rainfall runoff pollution loads, the correlations were weak or scarce in most items. These results might be attributed that runoff pollutant concentration changes vary severely on changes of rainfall intensity and rainfall duration within rainfall and it is affected by disturbances of vehicles and street cleaning and etc. as characteristics of the highway. While Cu, Fe and Zn which are discharged with high concentrations out of heavy metals showed high correlation with particulate matter, organic matter(COD), nutrient(TN, TP), Ni and Pb showed relatively low correlation in a correlation evaluation by pollutant. Significant correlation with traffic volumes was not shown and TSS concentration even decreased in accordance with increase of the traffic volume. In the comparison with precedent studies, it was considered necessary additional analysis of the effects of rainfall section analysis, road type, disturbances of surface contaminants by vehicles, rainfall and climate conditions, surrounding terrains etc.

Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting

  • Kumari, Priyanka;Lee, Joonhee;Choi, Hong-Lim
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.4
    • /
    • pp.594-598
    • /
    • 2016
  • We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems.

Composition and Size Variation of Airborne Fungal Spores in the Asian Dust Events (2000 ~ 2001)

  • Yeo, Hwan-Goo;Kim, Jong-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.4
    • /
    • pp.294-299
    • /
    • 2002
  • PM (Particulate Matter) samples contained fungal spores were collected in the ambient air of Seosan, west Korea, in springtime of 2000 and 2001. PM concentrations were $199.8\mu{g}\;m^{-3}$ in the 1st Asian Dust Storm period (March, 23 ~ 24) and $249.4\mu{g}\;m^{-3}$ in the 2nd period (April, 7~9), 2000. Compared with the concentrations in 2000, relatively low PM concentration ($157.3\mu{g}\;m^{-3}$ ) was measured in the Asian Dust Storm period (April, 24 ~ 20) of 2001. Although there were somewhat differences for the total PM concentrations among the three periods, majorities of the PM were composed of coarse particles sized about 5 ~ 6 $\mu{m}$ over the periods of the two years. Diverse molds grown from fungal aerosols were observed in the PM samples and identified at the genus level. All the genera, Fusarium, Aspergillus, Penicillium, Basipetospora, Epicoccum and Monotospora are hyphomycetes in the division Fungi imperfecti (Deuteromycota). Especially, morphologically more diversified mycelia of hyphomycetes were grown on the fine PM sample (1.1 ~ 2.1 $\mu{m}$) than coarse PM samples in the periods of 2000. Furthermore, some molds were grown on even the background PM sample less than 0.43 $\mu{m}$ in the period of 2001. It was thought that some kinds of ultra fine sized fungal spores were transported by the Asian Dust Storm and suspended in the ambient air of study area during the events.

A Pilot Study on Emission Analysis of Air Pollutants Produced from Portable Recycling of Asphalt Concrete (간이이동법에 의한 폐아스콘 재생시 대기오염물의 배출분석에 대한 실험적 연구)

  • Lee, Byeong-Kyu;Kim, Haeng-Ah;Jeong, Ui-Ryang;Duong, Trang;Chae, Po-Gi;Park, Kyung-Won
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.385-392
    • /
    • 2007
  • Currently, portable equipment for recycling of waste asphalt concrete (ASCON) has been used. However, any air pollution control devices are not attached in the simple portable one. Thus, a lot of air pollutants have been produced from recycling processes of waste ASCON which resulted from aging of paved roads or repavement of roads. This study deals with a preliminary result of concentration analysis of air pollutants obtained from a pilot and a real recycling processes of waste ASCON using simple portable recycling equipment. Air pollutants were taken from 4 steps of the pilot recycling process including an initial heating by liquid petroleum gas (LPG), intermediate heating and melting (H&M) process, final H&M process, and pavement processes using recycled ASCON at the recycling site. Also, air pollutants were taken front 4 steps of the real recycling processes including an initial H&M, final H&M and mixing, loading of recycled ASCON to dump trucks, and at the recycling site after leaving the loaded dump trucks for real pavement sites. The air pollutants measured in this study include volatile organic compounds (VOCs), aldehydes, particulate matter (PM: PM1, PM2.5, PM7, PM10, TSP (total suspended particulate)). The identified concentrations of VOCs increased with increasing time or degree for H&M of waste ASCON. In particular, very high concentrations of the VOCs at the status of complete melting, which is exposed to the air, of the waste ASCON just before paving tv the recycled ASCON at the recycling site. Also, considerable amount of VOCs were identified from the recycling equipment after the dump trucks leaded by recycled ASCON leaved the recycling site for the pavement sites. The relative level of formaldehyde exceeded 80% of the aldehydes Identified in the recycling processes. This is because the waste ASCON is exposed to direct flame of LPG during H&M processes. The PM concentrations measured in the winter recycling processes, such as the loading and rotation processes of waste ASCON into/in the recycling equipment for H&M, were much higher than those in the summer ones. In particular, the concentrations of coarse particles such as PM7 and PM10 during the winter recycling were very high as compared those during the summer one.

Estimation of Particulate Matter and Ammonia Emission Factors for Mechanically-Ventilated Pig Houses (강제환기식 양돈시설의 암모니아 및 미세먼지 배출계수 산정)

  • Park, Jinseon;Jeong, Hanna;Hong, Se-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.6
    • /
    • pp.33-42
    • /
    • 2020
  • Emission factors for ammonia and particulate matters (PMs) from livestock buildings are of increasing importance in view of the environmental protection. While the existing emission factors were determined based on the emission inventory of other countries, in situ measurement of emission factors is required to construct an accurate emission inventory for Korea. This study is to report measurements of ammonia and PMs emissions from mechanically-ventilated pig houses, which are common types of pig barns in Korea. Ventilation rates and concentrations of ammonia and PMs were measured at the ventilation outlets of a weaner unit, a growing pig unit and a fattening pig unit to calculated the emission factors. The PMs emission was characterized with different aerodynamic diameters (PM2.5, PM10, and total suspended particulates (TSP)). The measured ammonia emission factors for weaners, growing pigs and fattening pigs were 0.225, 0.869 and 1.679 kg animal-1 yr-1, respectively, showing linear increase with pigs' age. The PMs emission factors for three growing stages were 0.023, 0.237 and 0.241 kg animal-1 yr-1, respectively for TSP, 0.017, 0.072 and 0.223 kg animal-1 yr-1, respectively for PM10, and 0.011, 0.016 and 0.151 kg animal-1 yr-1, respectively for PM2.5. PMs emissions were increased with pigs' age due to increasing feed supply and animal movement. The measured emission factors were smaller than those of the existing emission inventory indicating that the existing ones overestimate the emissions from pig buildings and also suggesting that long-term in situ monitoring at various livestock buildings is required to construct the accurate emission inventory.