• Title/Summary/Keyword: Total suspended particulate

Search Result 149, Processing Time 0.023 seconds

Effectiveness of Settling Treatment System to Reduce Urban Nonpoint Source Pollutant Load by First Flush (초기 강우에 의한 도시 유역 비점오염 부하의 유입 저감을 위한 침강 처리 시설 적용 타당성 분석)

  • Kim, Jaeyoung;Seo, Dongil;Lee, Tongeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.140-148
    • /
    • 2017
  • The effectiveness of the first flush treatment system using settling process was evaluated to reduce urban nonpoint source pollutant loads to surface water during storm events. A pilot scale system was constructed and tested in the field and surface runoff samples were collected automatically according to pre-defined conditions. Nine rainfall events were tested and average removal efficiencies of TSS (Total Suspended Solid), TP (Total Phosphorus) and TN (Total Nitrogen) were evaluated as 87.4%, 75.3%, and 43.6%, respectively. Concentration and removal efficiency of pollutants were found to be affected by an amount of rainfall and rainfall intensities of the respective events. This seemed to be caused by the greater particulate fractions of first flushed samples than the samples collected in later time periods during the same rainfall events. The study showed that it is possible to remove a significant portion of the nonpoint source pollutant loads in initial rainfall runoff by using a simple settling process for TSS and TP without requiring additional power or chemicals.

A Study of Sewage Treatment with a Self-Cleaning Filtration Unit (자기세정 여과 반응장치를 이용한 하수처리에 관한 연구)

  • Mo, Sung-Young;Lee, Pul-Eip;Kim, Bum-Su;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.309-316
    • /
    • 2016
  • In this study, sewage was fed with up flow direction into a reactor equipped with a screw to circulate media that had lower specific gravity than water. It was observed that the media in the reactor could be circulated by a screw with reverse flow of the sewage feeding from the top to the bottom direction. Under these conditions, concentrations of inflow and outflow pollutants were measured at the filtration unit. Experimental results revealed stable circulation of the media with a screw in the reactor. Circulation of the media in the reactor showed more efficiency in removing the pollutants (particulate matters and organics) than no circulation. The maximum removal efficiencies of suspended solid (SS), chemical oxygen demand (CODmn), and total phosphorus (T-P) were 96%, 72% and 65%, respectively. Improvements for SS, CODmn and T-P removals with circulation of media were 52.38%, 43.14% and 118.12% respectively, compared to those without circulation.

Heavy Metals in Ambient Air at Shinchon Area in Seoul (도시 대기중 중금속에 관한 연구 -서울시 신촌지역을 중심으로-)

  • Chung, Yong;Jang, Jae-Yeon;Chu, Ui-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.18-26
    • /
    • 1987
  • In order to investigate the character of air pollution by heavy metals and to elucidate the possible sources in Seoul city, this study was performed to measure the concentrations of heavy metals of total suspended particulate and air pollutants such as $SO_2, NO_2, CO, CH_4$, Non-methane hydrocarbon, ozone at the residential-traffic area (shinchon dong) in January and February, 1986. The results are as follows: 1. $SO_2$ and TSP concentration were 135ppb and 167 $\mug/m^3$ in average, respectively. 2. While concentrations of heavy metals such as Fe, Cu, Pb in the ambient air seems gradually decreasing annually, Ni compound has been shown the tendency of increasing. 3. Among heavy metals in TSP analysed, the iron was detected at the highest level, 0.905% and the cadimium was the lowest 0.004% in average, respectively. 4. V, Fe and Zn compounds in air were observed to be highly correlated with their correlation coefficients(r) higher than 0.7. Pb compound was highly correlated to the levels of Zn and Fe, however relatively less correlated to V compound. 5. Among concentrations of heavy metals in the particulates, V and Ni compounds were highly correlated with coefficient(r) of 0.8587; the cause might be imagined by the fact of releasing from combustion of fuel oil. Fe, Pb and Zn compounds were highly correlated $SO_2$ concentration. It might be explained that they were released by combustion of coal. 6. The level of $SO_2$ was highly correlated to most of heavy metals: especially correlation coefficient(r) to Pb compound was 0.9081. Pb compound was also highly correlated to NO, CO and TSP. TSP showed higher correlation to Pb and Cd compounds than to V and Ni compounds. It might be assumed that particulate was mainly produced by combusting coal from space heating and by exhausting gasoline and diesel oil from transportation rather than by burning fuel oil.

  • PDF

Chemical characteristics of particulate species in Mt. Sobaek atmosphere(I) : The distribution and behaviour of major ion components (소백산 대기 중 입자상 물질의 화학적 특성에 관한 연구(I) : 이온 성분의 분포와 거동을 중심으로)

  • 이선기;최재천;이민영;최만식
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.179-184
    • /
    • 1995
  • This study was carried out to characterize sources of suspended particulate matter(SPM) in Mt. Soback area from January to Novembver in 1993. The collection and major water soluble ion analysis of SPM were conducted by using a High Volumn Air Sampler(HVAS; W&A Inc., PM-10) and ion chromatograph(DIONEX 4000i), respectively. The variations of SPM and major ion concentrations were found to be 9. sim. 156.mu.g/ $m^{3}$, $F^{-10}$ 0.00 .sim. 0.15.mu.g/ $m^{3}$, C $l^{-10}$ 0.06 .sim. 3.79.mu.g/ $m^{3}$, N $O_{3}$$^{-10}$ 0.90 .sim. 6.85.mu.g/ $m^{3}$, S $O_{4}$$^{2-}$ 1.99 .sim. 9.36.mu.g/ $m^{3}$ N $a^{+}$0.00 .sim. 0.27.mu.g/ $m^{3}$, N $H_{4}$ $^{+}$0.72 .sim. 5.77.mu.g/ $m^{3}$, $k^{+}$0.03 .sim. 0.88.mu.g/ $m^{3}$ and $Ca^{2+}$0.12 .sim. 2.76.mu.g/ $m^{3}$. Tree sources were identified by Principal Component Amalysis(PCA) using a SPSS/P $C^{+}$. The explanation ability of forst, second and third Principal Component were 60.8%, 13.6%, 8.2%, of total variance. The sources classfied by PCA were found to be secondary aerosol/fuel combustion, soil dust related cement production/yellow sand and aerosol related waste burning.related waste burning.g.

  • PDF

Distribution of Nutritive Salts and Organic Matters in the Coastal Area of East Sea (동해 연안역의 영양염과 유기물질의 분포)

  • Lee, Ki-Sung;Ko, Dong-Kyu;Heo, Seung;Lee, Young-Geun;Choi, Chung-Il;Choi, Young-Gil
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.1
    • /
    • pp.51-58
    • /
    • 1999
  • To investigate the distribution of nutritive salts and organic compounds in six stations at the coastal area of East Sea, environmental factors, nutritive salts, organic matters and chlorophyll were analysed four times from July 1994 to April 1995. The value of BOD in Ulsan Chuyongam was the highest among 6 stations. The concentration of nutritive salts was generally high through the investigation period near Pohang and Ulsan Chuyongam. From the value of dissolved nutrient salts, the Chuyongam area seemed to be under hyper-eutrophication and the Changsengpo area under eutrophication. Suspended particulate matter (SPM) of 3~10${\mu}{\textrm}{m}$ in size was distributed up to 70% of total volume. The amounts of SPM and particulate organic matter (POM) were considerably high in Pohang and Ulsan, which seemed to be resulted from the input of pollutants of cities and factories nearby.

  • PDF

Emission Characteristics of Air Pollutants and Black Carbon from Wood-pellet Stove and Boiler (목재 펠릿 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Kim, Daekeun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • This study was carried out simulating domestic utilization conditions of a wood pellet stove and a wood pellet boiler in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the pellet stove were: for TSP 4.58 g/kg, for $PM_{10}$ 3.35 g/kg, for $PM_{2.5}$ 2.48 g/kg, CO 119.23 g/kg, NO 14.40 g/kg, $SO_2$ 0.17 g/kg, TVOC 37.73 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the pellet boiler appliance: for TSP 4.73 g/kg, for $PM_{10}$ 3.41 g/kg, for $PM_{2.5}$ 2.63 g/kg, CO 161.51 g/kg, NO 13.67 g/kg, $SO_2$ 0.19 g/kg, TVOC 45.22 g/kg, $NH_3$ 0.02 g/kg.

Emission Characteristics of Air Pollutants and Black Carbon from Wood Stove and Boiler (화목 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Manually fed firewood burning appliances, i.e., stove and boiler, were tested in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the wood stove were: for TSP 15.45 g/kg, for $PM_{10}$ 6.53 g/kg, $PM_{2.5}$ 4.16 g/kg, CO 175.49 g/kg, NO 1.58 g/kg, $SO_2$ 0.15 g/kg, TVOC 48.02 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the wood boiler appliance: for TSP 12.23 g/kg, for $PM_{10}$ 5.84 g/kg, $PM_{2.5}$ 3.66 g/kg, CO 146.74 g/kg, NO 1.42 g/kg, $SO_2$ 0.15 g/kg, TVOC 47.78 g/kg, $NH_3$ 0.01 g/kg.

Distribution of Particulate Organic Matters along the Salinity Gradients in the Seomjin River Estuary (섬진강 하구역에서 염분경사에 따른 입자성 유기물질의 분포)

  • Kwon Kee Young;Moon Chang Ho;Kang Chang Keun;Kim Young Nam
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.1
    • /
    • pp.86-96
    • /
    • 2002
  • The distributions of suspended particulate matter (SPM), chlorophyll a, particulate organic carbon (POC) and nitrogen (PON) and particulate biogenic silica (PBSi) along the salinity gradient were investigated in the Seomjin River estuary from March 1999 to April 2001. Sampling sites were set based on the surface salinity during each cruise rather than geographic locations. Concentrations of SPM were less than 20 mg/L, suggesting relatively low input of terrestrial SPM despite large freshwater discharge through Seomiin River, Chlorophyll a peaks occurred at 5$\~$ 15 psu salinity zone (10$\~$20 km from Nan Cho Island) in November 1999, at 15$\~$25 psu (10$\~$20 km) salinity zone in April 2000 and at 1$\~$15 psu salinity zone (15$\~$20 km) in October 2000 (ca. 8$\~$58%\mu$g/L). Concentrations of POC, PON and PBSi were also high at the same zone. Relatively low ratios of POC to chlorophyll a in mid-salinity zone where POM peak occurred suggests high contribution of living phytoplankton to the total POC. On the other hand, relatively high ratios of POC to chlorophyll $\alpha$ in very low salinity zone and the mouth of estuary indicated relatively high portions of detrital POC. Consequently, the low concentrations of SPM in this estuary and the high concentrations of chlorophyll $\alpha$ and the low ratios of POC to chlorophyll $\alpha$ in the mid-salinity zone suggest that production of living phytoplankton is primary factor in controlling distribution of POM along the salinity gradients in the Seomjin River estuary.

Characterization of Respirable Suspended Particles and Polycyclic Aromatic Hydrocarbons associated with Environmental Tobacco Smoke

  • Baek, Sung-Ok;Park, Jin-Soo;Kim, Mi-Hyun;Roger A, Jenkins
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.1-17
    • /
    • 2000
  • In this study, the concentrations of particulate organic constituents of environmental tobacco smoke(ETS) were determined using an environmental smog chamber, where ETS is the sole source of target compounds. ETS was generated in a 30 ㎥ environmental chamber by a number of different cigarettes, including the Kentucky 1R4F reference cigarette and eight commercial brands. A total of 12 experimental runs was conducted, and target analytes included a group of ETS markers both in vapor and particulate phase and a class of polycylic aromatic hydrocarbos(PAHs) associated with ETS particles. The mass concentrations of PAH in ETS particles were also determined. The average contents of benzo(a) pyrene and benzo(a) anthracene in ETS particles for the commercial brands were 12.8 and 21.5$\mu\textrm{g}$/g, respectively, There values are all somewhat higher than those determined previously by other studies. Results form the chamber study are further used to estimate the average and variability of cigarette yields for target compounds associated with ETS. Finally, ratios of RSP to the surrogate standards of UVPM, FPM and solanesol were calculated for each sample. The average conversion factors factors for the eight commercial brands were 7.3, 38, and 41 for UVPM, EPM, and solanesol, respectively. The UVPM and FPM factors are in good agreement with the recently published values. Whereas there might be a substantial difference in the solanesol content among cigarettes produced in different countries, the variability is somewhat greater than those of UVPM and FPM, Unfortunately, comparison of the PAH yield data from this study with literature values was complicated by a lack of consistency in cigarette smoke generating methodology. Validation of the PAH yields was also difficult due to a lack of information on the ETS related PAH in the literature. From and engineering viewpoint , however, these data on the cigarette yields of ETS components may still provide useful information to studies on the mathematical modeling of indoor air quality management regarding tobacco smoke as a source of interest, or to studies on the assessment of human exposure to ETS.

  • PDF

Atmospheric concentration and mutagenicity of organic pollutants of suspended particulate in Seoul (서울시 대기중 유기오염물질의 농도와 돌연변이원성에 대한 연구)

  • Shin, Dong-Chun;Chung, Yong;Moon, Young-Hahn;Roh, Jae-Hoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.1 s.29
    • /
    • pp.43-56
    • /
    • 1990
  • To evaluate the difference of concentration and mutagenicity of organic pollutants between residential and traffic area of Seoul, air samples were collected in Bulkwang (residential) and Shinchon (traffic) area. Samples were analyzed to measure the concentration of extractable organic matters (EOM) and their subfractions and mutagenicities were tested using Salmonella typhimurium TA 98. The concentrations of polycyclic aromatic hydrocarbons (PAHs) were also measured by gas-chromatography and compared between two areas. The results were as follows ; 1. While the concentration of total suspended particulate (TSP) in residential area was below the environmental standard in annual average, the concentration in traffic area was above the standard and was up to its maximum $256{\mu}g/m^3$ in November. The difference of TSP concentrations in both areas of each month was statistically significant (P<0.05). 2. The concentration of fine particle in traffic area was significantly higher compare to that in residential area and showed statistically significant monthly difference in both areas (P<0.05). The proportion of concentration of fine particle to TSP was 55-68%. 3. Mean concentrations of EOM in residential and traffic areas were $4.3{\mu}g/m^3\;and\;5.3{\mu}g/m^3$ respectively. The proportion of amount of EOM from fine particle to EOM from TSP was 70-88%. 4. While the percentage of polar neutral organic compounds (POCN) of fine particle in Bulkwang's sample was higher compare to Shinchon's sample, the percentage of aliphatic compounds of fine particle in Shinchon's sample was higher compare to Bulkwang's sample. The percentages of PAH fraction were as low as 6-10% in both areas. 5. The mutagenic activity of nit concentration of organic matters extracted from fine particle was higher compare to that of coarse particle and was increased when metabolically activated with S9. Mutagenicities with metabolic activation calculated by unit air volume were significantly different between residential and traffic area, $17\;revertants/m^3$\;and\;22\;revertants/m^3$ respectively. 6. The concentrations of benzo(a)pyrene in fine particle of traffic and residential areas were $3.10ng/m^3\;and\;2.02ng/m^3$ respectively. Sixteen PAHs were higher in samples of traffic area compare to residential area and also concentrations of PAHs in fine particle were higher compare to coarse particle.

  • PDF