Numerical study on the flow characteristics in Air-conditioner duct of EMU (전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구)

  • Kim Seung-Tech;Kim Sung-Jong;Park Geun-Soo;Park Hyung-Soon
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

Enhancement of the Performance a Centrifugal Compressor in an Automobile Turbocharger by Modifying the Circumferential Inlet Height of Volute (원주방향 볼류트 입구 높이를 수정한 자동차용 터보차저 원심압축기의 성능 향상)

  • Zhou, Tianjun;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • To enhance the performance of an automobile turbocharger compressor, the circumferential inlet heights of the volute were modified and the flow field for the combined region of the diffuser and volute was numerically investigated using commercial software. Basically, a well-designed volute should have a high pressure recovery coefficient and a low loss coefficient for the total pressure. In this study, two circular volutes with the same cross sectional shape and tongue angle, but circumferentially different volute inlet heights, were selected. One volute had the middle inlet in the cross-section at the circumferential angle of $90^{\circ}$ but gradually lower inlet heights for the angles between $90^{\circ}$ to $360^{\circ}$ with respect to the cross sectional center of the volute, while maintaining the same height between the tangential line connecting the lowest positions of the cross section and the line connecting the volute inlets in the circumferential direction (case 1 volute). The other volute has an inlet height that is 2 mm lower than in case 1 volute such that the tongue section has a tangential inlet (case 2 volute). The results showed that the case 2 volute had a higher total pressure ratio because of its higher pressure recovery coefficient and higher isentropic efficiency, resulting from the lower loss coefficient along the circumferential position than the case 1 volute.

Investigation of difference of Gwakhyangjeonggi-san decoctions produced by different pressure levels and various extraction times (전탕 압력과 전탕 시간의 차이에 따른 곽향정기산 전탕액 비교)

  • Kim, Jung-Hoon;Lee, Nari;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • Herbal Formula Science
    • /
    • v.22 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Objectives : Gwakhyangjeonggi-san (GJS) which consists of 13 herbal medicines has been used to treat gastrointestinal disorders caused by common cold. This study was performed to compare GJS decoctions produced using different pressure levels for various extraction times. Methods : Decoctions were prepared by the pressure levels of $0kgf/cm^2$ (non-pressurized) or $1kgf/cm^2$ (pressurized) for 30-180 min. The extraction yield, total soluble solid content (TSSC), and hydrogen ion concentration (pH) were measured, and the contents of the nine marker compounds were determined using high performance liquid chromatography. Results : The higher pressure and longer extraction time significantly increased TSSC value, while decreased the pH value. However, only extraction time affected the extraction yield of pressurized decoction. Variation of the amounts of chemical compounds was shown in pressurized and non-pressurized decoctions during extraction time. The result of regression analysis showed that pressure and extraction time can influence to extraction yield, TSSC, pH, and the content of chemical compounds. Conclusions : This study suggests that the pressure and extraction time can significantly affect the extraction efficiency of components from GJS decoctions.

Effect of Surface Roughness on Performance of Axial Compressor Blade (축류압축기 블레이드의 표면조도가 성능에 미치는 영향)

  • Samad, Abdus;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.3 s.42
    • /
    • pp.9-16
    • /
    • 2007
  • Deterioration of surface of turbomachinery blades occurs in course of time due to many factors and hence reduces the performance of the machine. In this paper, the effects of surface roughness of transonic axial compressor blade on performance are studied considering a reference blade and a shape distorted (optimized) blade. Optimal blade is designed considering sweep and lean. Baldwin-Lomax turbulence model is used for flow field analysis and Cebeci-Smith roughness model is formulated for roughness modeling. It is found that, as the surface roughness increases, adiabatic efficiency, total temperature ratio and total pressure ratio decrease while Mach number increases. Performance deterioration is more severe in case of distorted blade as compared to reference blade.

A Study on the Output Characteristics of theraphy $CO_2$laser AC Converter $CO_2$ Laser System using 3 Electrode-type and Ring Blower (교류콘버터 기반에서 3전극 방식의 Theraphy $CO_2$ Laser 가변출력특성의 연구)

  • 김휘영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.257-260
    • /
    • 2002
  • In this paper, the circuit of AC Choppers for $CO_2$laser Power Supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transfomer used with the proposed system. This improved circuit employs a 3 electrode-type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirment, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$: $N_2$: He = 1 : 9 : 15, total pressure of 15torr.

  • PDF

Numerical Analysis on Effects of Positioning and Height of the Contoured Endwall on the Three-Dimensional Flow in an Annular Turbine Nozzle Guide Vane Cascade (끝벽의 설치 위치 및 변형 높이에 따른 환형 터빈 노즐 안내깃 캐스케이드 내 3차원 유동에 미치는 영향에 관한 수치해석)

  • Lee, Wu-Sang;Kim, Dae-Hyun;Min, Jae-Hong;Chung, Jin-Taek
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3247-3252
    • /
    • 2007
  • Endwall losses contribute significantly to the overall losses in modern turbomachinery, especially when aerodynamic airfoil load and pressure ratio are increased. Hence, reducing the extend and intensity of the secondary flow structures helps to enhance overall efficiency. From the large range of viable approaches, a promising combination positioning and height of endwall contouring was chosen. The objective of this study is to document the three-dimensional flow in a turbine cascade in terms of streamwise vorticity, total pressure loss distribution and static pressure distribution on the endwall and blade surface and to propose an appropriate positioning and height of the endwall contouring which show best secondary, overall loss reduction among the simulated endwall. The flow through the gas turbine were numerically analyzed using three dimensional Navier-Stroke equations with a commercial CFD code ANSYS CFX-10. The result shows that the overall loss is reduced near the flat endwall rather than contoured endwall, and the case of contoured endwall installed at 30% from leading edge with height of 25% for span showed best performance.

  • PDF

A Study on the Measurement of Break-up Length for the Diesel Sprays (디젤분무의 분열길이 측정에 관한 연구)

  • Jang, S.H.;Ra, J.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.22-28
    • /
    • 1999
  • The injected liquid does not break-up instantly after injection for diesel engine. There is some unbroken portion, which is the liquid core(The length of liquid core is called the break-up length) in the spray. If the liquid core is longer than the depth of the bowl in the small DI diesel engine, the liquid core impinges on the surface of the piston. Once the liquid core impinges on the surface, it cannot ignite or burn rapidly and thus prolongs burning time with a degradation in thermal efficiency. The break-up length of a diesel spray in a compressure vessel was measured by an electric resistance method, A voltage was applied between the nozzle and screen, bar, needle electrode inserted at various axial and radial positions into atomizing sprays. As a result, a current flows not only in the region of liquid core but also through the droplets of the spray. It is found that the break-up length measured with screen electrode is overestimated. The break-up length of the spray is found to be proportional to the square root of the density ratio of fuel and surrounding gas. The break-up length of the spray decreases as the injection pressure and the back pressure increase.

  • PDF

Applicability of Washing Techniques Coupled with High-Pressure Air Jet for Petroleum-contaminated Soils (고압공기분사를 이용한 유류오염토양 세척기법의 적용성 연구)

  • Choi, Sang-Il;Kim, Kang-Hong
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.61-68
    • /
    • 2006
  • Soil washing techniques coupled with high pressure air jet were applied for diesel-contaminated soils sampled by an underground oil reservoir of which the initial total petroleum hydrocarbon (TPH) ($2,828{\pm}206\;mg/kg$) exceeded 5 times of current standard level (500 mg/kg) regulated by the Soil-Environment Conservation Law. Through several tests, we found that the position of impeller has a critical impact for washing efficiencies. The highest washing efficiency was obtained at an oblique angle (30 degree) for the impeller and optimized mixing speed (300 rpm) that could have high shearing forces. Considered economical and feasible aspects, the optimum mixing time was 10 min. Rate constants of TPH removal derived from the first-order equation were not linearly increased as mixing speed increased, indicating that mechanical mixing has some limits to enhance the washing efficiencies. Application of high-pressure air jet in washing process increased the washing efficiency. This increase might be caused by the fact that the surface of micro-air bubbles strongly attached hydrophobic matters of soil particles. As the pressure of air jet increased, the separation efficiencies of TPH-contaminated soil particles increased. In the combined process of high-pressure air jet and mixing by impeller, the optimum mixing speed and air flow-rate were determined to be 60 rpm and $2\;kg/cm^2$, respectively. Consequently, the washing technique coupled with high-pressure air jet could be considered as a feasible application for remediating petroleum-contaminated soils.

Effect of Height Variation of Recirculating Casing Treatment on the Performance of a Turbocharger Compressor (재순환케이싱처리 높이변화가 터보차저 압축기의 성능에 미치는 영향)

  • Nguyen, Van Hap;Zhou, Tianjun;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.669-675
    • /
    • 2015
  • In this study, we investigate the performance variations of an automotive turbocharger compressor with respect to the height variation of the recirculating casing treatment (RCT). We use three RCT heights, namely 1.2 mm, 1.5 mm, and 1.8 mm. We vary the compressor speed from 90,000 to 150,000 rpm, and the flow rate from 0.015 kg/s to 0.08 kg/s. The calculation results of the total pressure ratio and isentropic efficiency showed good agreement with the performance data provided by the manufacturer within a 0.7 percent error. The results showed that the RCT heights of 1.2 mm, 1.8 mm, and 1.5 mm, in that order, exhibited a more uniform pressure distribution, higher pressure ratio, and wider operational range. As the number of revolutions per minute increased, we obtained typical characteristics of a compressor map having a narrower operational range in the region of higher pressure ratio.

A Case Study on the Release Characteristic and Removal Efficiency of Vinyl Chloride in the Poly Vinyl Chloride Extrusion Process (PVC압출공정의 염화비닐 발생특성과 작업환경개선에 관한 사례연구)

  • Park, Dong Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.91-98
    • /
    • 1993
  • This study was carried out to investigate characteristic of vinyl chloride emissioned from poly vinyl chloride extrusion process and to evaluate the efficiency of local exhaust ventilation system. Before local ventilation facility was constructed in poly vinyl chloride extrusion process, the average worker exposure to vinyl chloride was 3.15 ppm, which exceeded Threshold Limit Value of American Conference of Gorvernmental Industrial Hygienists (ACGIH-TLV), 1 ppm. lt is possible that vinyl chloride residues in the poly vinyl chloride resin was released or degased due to extrusion heat. The larger the width of vinyl tube become, the higher worker exposure to vinyl chloride was. It is estimated that vinyl chloride from vinyl chloride resin increased as amount of poly vinyl chloride resin extruded in the extrusion process increased. Canopy hood was an appropriate type for poly vinyl chloride resin extrusion process. This local exhaust ventilation has fan static pressure of 7.65 inch wg($190mmH_2O$, total volumetric flowlate of 4,796 CFM ($135.8m^3$/min) and fan power requirement of 12 hp (8.952 Kw). After this local exhaust ventilation was constructed there, the average concentration of worker exposure to vinyl chloride was reduced to be 0.46 ppm, which was below the Threshold Limit Value, 1 ppm. Also, the removal efficiency rate of vinyl chloride attained by local exhaust ventilation was 85.3%. It was a statistically significant (p<0.01).

  • PDF