• Title/Summary/Keyword: Total pressure distribution

Search Result 333, Processing Time 0.043 seconds

Impact of Largemouth Bass (Micropterus salmoides) on the Population of Korean Native Fish, Crucian Carp (Carassius auratus) (배스가 국내 호소에 서식하는 붕어 개체군에 미치는 영향)

  • Lee, Jin-Woong;Kim, Jeong-Hui;Park, Sang-Hyeon;Choi, Kee-Ryong;Lee, Hae-Jin;Yoon, Ju-Duk;Jang, Min-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.31 no.4
    • /
    • pp.370-375
    • /
    • 2013
  • Exotic species in aquatic ecosystem generate various problems domestically as well as globally. Largemouth bass (Micropterus salmoides) which is a well-known exotic species globally, acts as a substantial disturbance factor on the native fish communities in Korea due to the high predation pressure and hence designated as a ecologically harmful species by Ministry of Environment. In this study, we investigated the impact of largemouth bass on Korean native fish population, crucian carp (Carassius auratus), to identify responses of the prey fish. Two fish species were collected at seven reservoirs distributed at the Nakdong River catchment area, and changes in length-frequency and length-weight relationship (LWR) were analysed depending on existence of large-mouth bass. At bass absent sites, ratio of under age 1 year individuals were small, and over age two years were dominant. Conversely, normal length-frequency distribution pattern was identified at bass absent sites. The LWR of crucian carp (fish smaller than total length of 160 mm were only considered as it is frequently consumed by bass predation) was different depending upon bass existence. The value of parameter b at bass absent reservoirs was 2.909, which was smaller than that of bass present reservoirs, 3.100. Our results imply that crucian carp at bass present reservoirs presented a different strategy to survive from predation by bass, through relatively rapid growth. We propose that other native species might have similar growth strategies like crucian carp.

Synthesis of Uniformly Doped Ge Nanowires with Carbon Sheath

  • Kim, Tae-Heon;;Choe, Sun-Hyeong;Seo, Yeong-Min;Lee, Jong-Cheol;Hwang, Dong-Hun;Kim, Dae-Won;Choe, Yun-Jeong;Hwang, Seong-U;Hwang, Dong-Mok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.289-289
    • /
    • 2013
  • While there are plenty of studies on synthesizing semiconducting germanium nanowires (Ge NWs) by vapor-liquid-solid (VLS) process, it is difficult to inject dopants into them with uniform dopants distribution due to vapor-solid (VS) deposition. In particular, as precursors and dopants such as germane ($GeH_4$), phosphine ($PH_3$) or diborane ($B_2H_6$) incorporate through sidewall of nanowire, it is hard to obtain the structural and electrical uniformity of Ge NWs. Moreover, the drastic tapered structure of Ge NWs is observed when it is synthesized at high temperature over $400^{\circ}C$ because of excessive VS deposition. In 2006, Emanuel Tutuc et al. demonstrated Ge NW pn junction using p-type shell as depleted layer. However, it could not be prevented from undesirable VS deposition and it still kept the tapered structures of Ge NWs as a result. Herein, we adopt $C_2H_2$ gas in order to passivate Ge NWs with carbon sheath, which makes the entire Ge NWs uniform at even higher temperature over $450^{\circ}C$. We can also synthesize non-tapered and uniformly doped Ge NWs, restricting incorporation of excess germanium on the surface. The Ge NWs with carbon sheath are grown via VLS process on a $Si/SiO_2$ substrate coated 2 nm Au film. Thin Au film is thermally evaporated on a $Si/SiO_2$ substrate. The NW is grown flowing $GeH_4$, HCl, $C_2H_2$ and PH3 for n-type, $B_2H_6$ for p-type at a total pressure of 15 Torr and temperatures of $480{\sim}500^{\circ}C$. Scanning electron microscopy (SEM) reveals clear surface of the Ge NWs synthesized at $500^{\circ}C$. Raman spectroscopy peaked at about ~300 $cm^{-1}$ indicates it is comprised of single crystalline germanium in the core of Ge NWs and it is proved to be covered by thin amorphous carbon by two peaks of 1330 $cm^{-1}$ (D-band) and 1590 $cm^{-1}$ (G-band). Furthermore, the electrical performances of Ge NWs doped with boron and phosphorus are measured by field effect transistor (FET) and they shows typical curves of p-type and n-type FET. It is expected to have general potentials for development of logic devices and solar cells using p-type and n-type Ge NWs with carbon sheath.

  • PDF

Leukocyte count and hypertension in the health screening data of some rural and urban residents (일부 농촌과 도시의 건강선별조사 자료로 본 백혈구수와 고혈압과의 관계)

  • Lee, Choong-Won;Yoon, Nung-Ki;Lee, Sung-Kwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.363-372
    • /
    • 1991
  • We used the health screening data of some rural and urban residents to examine the cross-sectional association between leukocyte count and hypertension. The 206 male and 203 female rural residents were selected by multi-stage cluster sampling method in Kyungsan-Kun area of Kyungbuk province in 1985 and 600 urban residents were selected by the same sampling method as the rural residents in Daegu city of the same province in 1986 compatible with age-sex distribution of Daegu city of 1985 census, but of whom 384 actually responded. The rest of 600 were replaced by age and sex with those who were members of the medical insurance plan visiting the health management department of the university hospital to get the biannual preventive medical checkups. Excluded in the analysis were those having hypertensive history, diseases and extreme outlying values of the screening tests, leaving 373 rural and 571 urban residents. Leukocyte count was measured with ELT-8 Laser shadow method and the unit $cells/mm^3$, Blood pressures were determined with an aneroid sphygmomanometer with pre-standardized method and hypertensives were defined as those showing systolic blood pressure more than 140mmHg and/or diastolic blood pressure more than 90mmHg. Total residents pooled (N=944) showed a significant difference between hypertensives and normotensives ($6965.93{\pm}1997.01\;vs\;6490.61{\pm}1941.32,\;P=0.00$) and in rural residents was noted the similar significant difference (P=0.03). None of significant differences were noted in any stratum stratified by residency and sex. Compared to the lowest quintile of WBC, 2/5 quintile showed odds ratio 0.99 (95% Confidence interval, Ci 0.62-1.59), 3/5 quintile 1.41 (95% CI 0.90-2.21), 4/5 quintile 1.76 (95% CI. 1.14-2.72), and highest quintile 1.80 (1.15-2.82) in the total residents. Likelihood ratio test for linear trend for it indicated a significant trend ($X^2_{trend}=5.53,\;df=1,\;P<0.05$). There were no other significant odds ratios compared to the lowest quintile of WBC in strata stratified by residency and sex. The odds ratios in total residents which had showed significant odds ratios became nonsignificant and of reduced magnitude after controlling age, frequency of smoking and drinking with multiple logistic. regression. In each stratum, it changed magnitudes of odds ratios slightly and unstably. None of the trend tests showed any significant trend. These results suggest that the Friedman et al's finding of association between leukocyte count and hypertension may be due to an statistical type I error resulting from the data dredging in an exploratory study, in which more than 800 variables were screened as possible predictors of hypertension.

  • PDF

The Change of The Effect on The Subcutaneous Fat Area and Visceral Fat Area by The Functional Electrical Stimulation and Aerobic Exercise (기능적 전기 자극과 유산소 운동이 복부비만의 피하지방과 내장지방에 미치는 효과)

  • Oh Sung-tae;Lee Mun-hwan;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.85-123
    • /
    • 2004
  • Back ground : Subcutaneous fat area is the main factor involved in replacement disease and arteriosclerosis. Simple weight control is the appropriate medical treatment. It's understood that weight reduction does not only reduce the fat concentrations in blood but also reduces blood pressure, improves glucose levels in diabetes patients and reduces incidents of heart disease. there are several methods for reducing fat in the abdominal region but their effectiveness is not folly understood. one method is electrical stimulation of the problem areas. Method : From May 1st 2002 to October 31st. The 15 subjects who received medical examination were aged between 25 and 53 and were of mixed gender. The subjects were divided into two groups one to received functional electrical stimulation and the other a control group. Using Broca's criterion for judging fat grades. I analysed the differences between the two groups before and after the treatment. Subjects received functional electrical stimulation on the abdominal muscle intensity 50Hz. They received this treatment 4 days a week for 40 minutes a day. In the case of aerobic exercise, at the Treadmill, we used it with the intensity of $75\%$ maximum heart rate (220-age). Result 1)After functional electrical stimulation in the case of male subjects, the weight was reduced 1.93kg, obesity $2.60\%$, fat mass 2.73kg, Percent body fat $4.40\%$, waist circumference 6.53cm, circumference of hips 5.53cm. On the other side, the quality of muscle was increased at the rate of 1.03kg, but it's not attentional level. The subcutaneous fat area was reduced by $26.63cm^2$, the visceral fat area was reduced by $43.00cm^2$, In the female subjects, we can see the reduction of fat grade by $26.63cm^2$, the quantity of body fat by 1.5kg, percent body fat by $1.77\%$, circumference of waist by 4.02cm, circumference of hips by 3.67cm, weight by 1.40kg but was increased 0.72kg at the quantity of muscles. We can see the reduction also in the subcutaneous fat area $24.03cm^2$, the visceral fat area by $25.36cm^2$. 2)After aerobic exercise, on the male subjects, we can see reduction of weight by 3.36kg, obesity by $4.00\%$, fat mass by 2.83kg and we can see increase at the soft lean mass by 2.96kg, but we can see reduction, the percent body fat by $3.03\%$, fat distribution by $0.023\%$, circumference of waist by 3.10cm, circumference of hips by 2.23cm. The female subjects show a reduction in the weight by 2.48kg, percent body fat by $2.20\%$, show an increase in the soft lean mass by 1.54kg. We can see a reduction in the quantity of fat mass by 2.32kg, the percent body fat by $2.80\%$, the circumference of waist by 2.16cm, the circumference of hips by 2.68cm, the fat distribution by $0.016\%$, the subcutaneous fat area by $15.25cm^2$ the visceral fat area by $11.52cm^2$. After aerobic exercise, we can't see the attentional change at the total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. 3)After the application of functional electrical stimulation and aerobic exercise, in result of measurement on the body ingredient, we could see the weight reduction and increase the quantity of muscle with the male group who exercised aerobic. We can see the attentional rate on the electrical stimulation about abdominal fat rate, circumference of waist, circumference of hips. The other hand, I couldn't see the attentional differences between the two groups in the rate of fatness and quantity of body fat and the rate of body fat. There isn't any attentional difference in the area of fat under skin, on the contrary, There is attentional difference in the fat in the internal organs area at the electrical stimulation site. We can't see the attentional change of total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol between electrical stimulation and aerobic exercise. 4)After execution of functional electrical stimulation and aerobic exercise, in result of measurement on change of body ingredient among female objects, We could see weight reduction, increase at muscle quantity in the aerobic exercise group. We could see the attentional differences in the rate of fatness, the rate of abdominal region, the circumference which received electrical stimulation. But, we couldn't see the attentional differences between two groups in the quantity of body fatness, the circumference of hips. The subcutaneous fat area doesn't show the attentional differences. On the Contrary, we could see lots of differences in the visceral fat area of the electrical stimulation group. Conclusion The results show that functional electrical stimulation and aerobic exercise have insignificant differences when if comes to total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. Though there is affirmative change in body ingredient after both electrical stimulation and aerobic exercise. Functional electrical stimulation is more effective on the subcutaneous fat area and in changing visceral fat area. There fore. It is concluded that the physical therapy is more effective in the treatment of abdominal fatness.

  • PDF

What Factors Affect Mortality over the Age of 40? (40세 이후의 사망에 영향을 주는 요인에 관한 코호트내 환자-대조군 연구)

  • Park, Jong-Ku;Koh, Sang-Baek;Kim, Chun-Bae;Park, Kee-Ho;Wang, Seung-Jun;Chang, Sei-Jin;Sin, Soon-Ae;Kang, Myung-Guen
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.3
    • /
    • pp.383-394
    • /
    • 1999
  • Objectives: This study was conducted to identify the factors influencing the mortality of Koreans over the age of 40 by a nested case-control study. Methods: The cohort consisted of the beneficiaries of Korea Medical Insurance Corporation for Government Employees & Private School Teachers and Staff(KMIC) who received health examinations of KMIC in 1992 and 1993 retrospectively. At that time, they were more than 40 years old. The cases were 19,258 cohort members who had died until December 31, 1997. The controls were 19,258 cohort members who were alive until December 31, 1997. Controls were matched with age and sex distribution of the cases. The data used in this study were the funeral expenses requesting files, and the files of health examinations and health questionnaires gathered in 1992 and 1993. To assess the putative risk factors of death, student t-test, chi-square test, multiple logistic regression analysis were used. Results : In multiple logistic regression analysis, independent risk factors of death were as follows; systolic blood pressure, diastolic blood pressure, blood glucose, AST, urine glucose, urine protein, alcohol drinking(frequency), cigarette smoking and perceived health status, intake of restoratives and blood transfusion showed positive associations with death; coffee consumption showed negative associations with death; and body mass index and serum total cholesterol showed J-shaped association with death. Conclusions: Regarding the direction of association, the result of analysis on the data restricted to '96-'97 was same as that of '93-'97. But in some variables such as obesity, serum cholesterol, the odds ratios of death in the data of '96-'97 were higer than those of '93-'94, which suggested that the data of '93-'94 was bearing effect-cause relationship. We concluded that it suggested further researches using long-term follow-up data to be needed in this area.

  • PDF

Impact of Pulmonary Vascular Compliance on the Duration of Pleural Effusion Duration after Extracardiac Fontan Procedure (수술 전 폐혈관 유순도가 심장 외 도판을 이용한 Fontan 수술 후 늑막 삼출 기간에 미치는 영향)

  • Yun Tae-Jin;Im Yu-Mi;Song Kwang-Jae;Jung Sung-Ho;Park Jeong-Jun;Seo Dong-Man;Lee Moo-Song
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.579-587
    • /
    • 2006
  • Background: Preoperative risk analysis for Fontan candidates is still less than optimal in that patients with apparently low risks may have poor surgical outcome; prolonged pleural drainage, protein losing enteropathy, pulmonary thromboembolism and death. We hypothesized that low pulmonary vascular compliance (PVC) is a risk factor for prolonged pleural effusion drainage after the Fontan operation. Material and Method: A retrospective review of 96 consecutive patients who underwent the Extracardiac Fontan procedures (median age: 3.9 years) was performed. Fontan risk score (FRS) was calculated from 12 categorized preoperative anatomic and physiologic variables. PVC $(mm^2/m^2{\cdot}mmHg)$ was defined as pulmonary artery index $(mm^2/m^2)$ divided by total pulmonary resistance $(W.U{\cdot}/m^2)$ and pulmonary blood flow $(L/min/m^2)$ based on the electrical circuit analogue of the pulmonary circulation. Chest tube indwelling time was log-transformed (log indwelling time, LIT) to fit normal distribution, and the relationship between preoperative predictors and LIT was analyzed by multiple linear regression. Result: Preoperative PVC, chest tube indwelling time and LIT ranged from 6 to 94.8 $mm^2/mmHg/m^2$ (median: 24.8), 3 to 268 days (median: 20 days), and 1.1 to 5.6 (mean: 2.9, standard deviation: 0.8), respectively. FRS, PVC, cardiopulmonary bypass time (CPB) and central venous pressure at postoperative 12 hours were correlated with LIT by univariable analyses. By multiple linear regression, PVC (p=0.0018) and CPB (p=0.0024) independently predicted LIT, explaining 21.7% of the variation. The regression equation was LIT=2.74-0.0158 PVC+0.00658 CPB. Conclusion: Low pulmonary vascular compliance is an important risk factor for prolonged pleural effusion drainage after the extracardiac Fontan procedure.

Remediation of Sediments using Micro-bubble (미세기포를 이용한 퇴적물 정화)

  • Kang, Sang Yul;Kim, Hyoung Jun;Kim, Tschung Il;Park, Hyun Ju;Na, Choon Ki;Han, Moo Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.420-427
    • /
    • 2016
  • This study was conducted on the sediment remediation using micro-bubble to remove fine particles. For this study, characteristics of contamination and release in sediment were analyzed. And then, the characteristics of bubbles on removal efficiency was investigated at various operation conditions. In particle size distribution of the sediment used for the study, the proportion of clay and silt (<0.075 mm) was about 7.7%, sand (0.075~4.75 mm) was about 67.8%, and gravel (${\geq}4.75$) was 24.5%. Total nitrogen (TN) and total phosphorus (TP) of the sediment were 2,790~3,260, 261~311 mg/kg respectively. Ignition loss and water content were 4.1~9.6, 32.9~53.2% respectively. In analysis of removal efficiency according to operation conditions of micro-bubble, it was the highest when operation condition is pressure 6 atm, pressurized water ratio 30%, and coagulant dosage 15 ppm. At the time, the sediment's removal efficiency was 19.9%. Accordingly removal efficiency of TN and TP were 21.4, 22.6% respectively. Finally a research was found that fine particles in sediment were almost removed by micro-bubble, which led to decrease nutrients' release at about 20.1~64.3% in comparison to sediment including lots of fine particles.

Division of Soil Properties in Reclaimed Land of the Mangyeong and Dongjin River Basin and Their Agricultural Engineering Management (만경강과 동진강 유역 간척농경지 토양특성 구분과 농공학적 관리 대책)

  • Hwang, Seon-Woong;Kang, Jong-Gook;Lee, Kyung-Do;Lee, Kyung-Bo;Park, Ki-Hun;Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.3
    • /
    • pp.444-450
    • /
    • 2012
  • The physical and chemical properties of soil in the Mangyeong and Dongjin river basin had been investigated in order to establish the most optimum soil improvement plan on the reclaimed land. The total soil area by reclamation in Saemangeum basin is 113,971 ha. The classification by the distribution of soil series and soil texture is as following. 13 soil series including Chonnam, Buyong and Chonbuk series are period-unknown areas. Regarding the soil texture, they are fine silty ~ clayey very fine. From 1920s to 1960s, Mangyeong, Gwanghwal and Chonbuk series had coarse silty textured soil. After the 1970s, Mangyeong, Gwanghwal, Munpo, Yeompo, Poseung, Gapo and Hasa series have more sandy soil ~ moderately coarse loamy textured soil. Regarding the chemical properties, the concentrations of EC, Exch. $K^+$, $Mg^{2+}$, $Na^+$ and pH are high regardless of the time of reclamation. On the other hand, organic matter (OM) of top soil were 3.3~16.1 g $kg^{-1}$. The organic matter contents were very low though the soil had been farmed for a long time. Furthermore, the deep soil had almost no organic matter with 5.6~1.1 g $kg^{-1}$. The reason is believed that there had not been any movement of OM and clay because pressure or induced pans had been formed by large agricultural machineries and poor vertical drain. Regarding the forming of illuvial horizon (B layer) which tells the development extent of soil, only in the Hwapo reclaimed area where rice had been cultivated for past 90 years, Fe and Mn from top soil are deposited at underground 20~30 cm with 7~8 cm thickness by the movement of clay. It is believed that it had been possible because the earthiness is silty clay loam soil with relatively high content of clay. The soils are soil with concern of damage from sea water, soil on flimsy ground and sandy soil. Therefore, soil improvement for stable crop production can be expected; if the water table would be lowered by subsurface drainage, the water permeability would be enhanced by gypsum and organic matter, and the sandy soil would be replaced by red soil with high content of clay.

Comparison of chronic disease risk by dietary carbohydrate energy ratio in Korean elderly: Using the 2007-2009 Korea National Health and Nutrition Examination Survey (한국 노인 식사의 탄수화물 에너지비에 따른 만성질환 위험성 비교: 2007~2009년 국민건강영양조사 자료 이용)

  • Park, Min Seon;Suh, Yoon Suk;Chung, Young-Jin
    • Journal of Nutrition and Health
    • /
    • v.47 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Purpose: It is reported that most senior people consume a high carbohydrate diet, while a high carbohydrate diet could contribute to the risk of chronic disease. The aim of this study is to determine whether a high carbohydrate diet can increase the risk of chronic disease in elderly Koreans. Methods: Using the 2007-2009 Korean National Health Nutrition Examination Survey data, out of a total of 3,917 individuals aged 65 and above, final 1,535 subjects were analyzed, divided by dietary carbohydrate energy ratio into two groups of moderate carbohydrate ratio (MCR, 55-70%) and excessive carbohydrate ratio (ECR, > 70%). All data were processed after the application of weighted value, using a general linear model or logistic regression. Results: Eighty one percent of elderly Koreans consumed diets with carbohydrate energy ratio above 70%. The ECR group included more female subjects, rural residents, lower income, and lower education level. The ECR group showed lower waist circumference, lower diastolic blood pressure, and lower frequency of consumption of meat and egg, milk, and alcohol. The intake of energy and most nutrients, with the exception of fiber, potassium, vitamin A, and carotene, was lower in the ECR group compared to the MCR group. When analyzed by gender, the ECR group showed lower risk of dyslipidemia in male and obesity in female subjects, even though the ECR group showed low intake of some nutrients. No difference in the risk of hypertension, diabetes, and anemia was observed between the two groups in male or female subjects. Conclusion: This result suggested that a high carbohydrate diet would not be a cause to increase the risk of chronic disease in the elderly. Further study is needed in order to determine an appropriate carbohydrate energy ratio for elderly Koreans to reduce the risk of chronic disease.

On the Observation of Sandstorms and Associated Episodes of Airborne Dustfalls in the East Asian Region in 2005 (2005년 동아시아 지역에서 발생한 모래폭풍과 먼지침전(황사)의 관측)

  • Kim, Hak-Sung;Chung, Yong-Seung
    • Journal of the Korean earth science society
    • /
    • v.30 no.2
    • /
    • pp.196-209
    • /
    • 2009
  • Occurrences of sandstorms in the deserts and loess of Mongolia and northern China and associated dustfall episodes in the Korean Peninsula were monitored during the period January through December, 2005. False colour images were made by directly receiving the NOAA Advanced Very High Resolution Radiometer (AVHRR) data, and the distribution and transport of sandstorms were analyzed. The ground concentrations for PM10, PM2.5 and visibility of the dustfall episodes (PM10 concentration over $190{\mu}g\;m^{-3}$) were analyzed at Cheongwon, located midway in South Korea, and in the leeward direction of the place of origin of the sandstorms. Variations in the concentrations of $O_3,\;NO_2$, CO and $SO_2$ were also compared with dust concentrations in the dustfall episodes. Fewer occurrences of strong sandstorms in the place of origin were observed in 2005, due largely to the accumulation of snow and mild fluctuations of high and low pressure systems in the place of origin, thereby accounting for a low frequency of dustfall episodes in Korea, compared with those during the period 1997-2005. A total of 7 dustfall episodes were monitored in Korea in 2005 that lasted 11 days. In summer, sandstorms occurred less frequently in the source region in 2005 due to high humidity and milder winds, thereby causing no dustfall episodes in Korea. In case the sandstorms occurring at the place of source head directly to Korea without passing through large cities and industrial areas of China, the PM2.5 concentrations were measured at 20% or lower than the PM10 concentrations. However, when the sandstorms headed to Korea via the industrial areas of eastern China, where they pick up anthropogenic air pollutants, the PM2.5 concentrations were at least 25% higher of the PM10 concentrations. On the other hand, over 5 cases were observed and analyzed in 2005 where the PM10 concentrations of sand dust originating from the deserts were measured at $190{\mu}g\;m^{-3}$ or lower, falling short of the level of a dustfall episode.