• Title/Summary/Keyword: Total hip

Search Result 706, Processing Time 0.027 seconds

Effects of Supportive Nursing Care Program on Hip Function, Anxiety and Uncertainty for Patients with Total Hip Arthroplasty (인공 고관절 수술 환자에서 지지간호중재가 고관절 기능, 불안 및 불확실성에 미치는 효과)

  • Kim, Sun Hwa;Lee, Hye Jin
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.3
    • /
    • pp.419-431
    • /
    • 2013
  • Purpose: This study was to evaluate the effect of supportive nursing care program for patients with total hip arthroplasty. Methods: Forty-two patients with total hip arthroplasty were enrolled in this study from September, 20, 2011 to January, 3, 2012. The participants were assigned to one of two groups: Twenty-six subjects in the experimental group were provided with supportive nursing care program which comprised of 6 nurse visits pre and post operation and 4 follow-up phone calls after discharge. Another 26 subjects received conventional nursing care program as a control group. Hip function, anxiety, and uncertainty were evaluated before the intervention, and 5 weeks after completion of the intervention. The analysis included descriptive statistics, Chi-square test, and t-test by SPSS 18.0. Results: Hip function was significantly increased in the experimental group (t=-3.31, p<.002). Anxiety and uncertainty group was significantly lower in the experimental group (t=7.12, p<.001 and t=4.66, p<.001). Conclusion: The results of this study indicate that the supportive care intervention for patients receiving total hip arthroplasty could be utilized as a nursing intervention to improve hip function and to reduce anxiety and uncertainty of patients receiving total hip arthroplasty.

A Rehabilitation for Total Hip Replacement in Korean Medicine: A Report of Three Cases (고관절 전치환술 후 한방 재활치료에 대한 증례 보고)

  • Ha, Won-Bae;Lee, Jong-Ha;Ko, Youn-Seok;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.3
    • /
    • pp.153-164
    • /
    • 2016
  • The objective of this study was to propose a rehabilitation protocol for total hip replacement in Korean medicine and to report its effectiveness. Three patients who had undergone total hip replacement were treated using the rehabilitation protocol in Korean medicine. We evaluated the outcome evaluating physical examination findings of the hip joint, numeric rating scale, pain disability index, Harris hip score, and walking state. After the treatment, we observed that hip movement and muscular strength improved. Moreover numeric rating scale, pain disability index, Harris hip score, and walking state of patients improved. A rehabilitation in Korean medicine can be effectively used for total hip replacement patients. The limitation of this study was the insufficient number of cases. Further studies are needed to design a rehabilitation protocol in Korean medicine.

Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • Kim, Chung-Kyun;Yoon, Jong-Deok
    • Tribology and Lubricants
    • /
    • v.13 no.1
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.

Development of Hip Joint Simulator to Evaluate The Wear of Biomaterials Used in Total Hip Joint Replacement (인공고관절 생체재료 마멸평가를 위한 시뮬레이터 개발)

  • 이권용;윤재웅;전승범;박성길
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.265-270
    • /
    • 2001
  • Hip joint simulator which Is an essential device for evaluating the wear of biomaterials (ultrahigh molecular weight polyethylene, Co-Cr alloy, alumina, etc.) used in total hip joint replacement was developed. This hip joint simulator mimics the joint motion and joint loading of human gait by adapting the 4 degree of freedom in kinematic motion (flexing/extension, adduction/abduction, Internal rotation/external rotation) and axial loading, Four stations are operated by 8 servo-motors and harmony drives. Joint leading was imposed by displacement control from a ball screw, LM guide, and spring system. Each kinematic link system operates separately or coupled modes. A heater and a thermocouple were installed for keeping the body temperature in each station.

  • PDF

Analysis of Lower body on Korean Young Women and the Effect of the Lower body Type on the Shape of Flare Skirt (I) (한국 미혼 여성의 하반신체형 분석과 체형변인이 플레어스커트 입체성능에 미치는 영향(I))

  • 조정미
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.3
    • /
    • pp.1-13
    • /
    • 1992
  • The purpose of this study was (1) to classify the lower body of young women, (2) to investigate the three-dimensional characteristics of each lower body type. The subjects for direct anthrophometric measurements were 330 female college students aged from 18 to 25. Thirty variables(16 directly obtained from the anthropometric data and 14 indices) were used for lower body classification. The data were statintically analyzed by the principal factor analysis and the cluster analysis. Factors extracted were used as variables for the cluster analysis. To detect three-dimensional characteristics of each lower body type, horizontally sectioned overlap maps were obtained by the moire photography. The results obtained from this study were as follows: The lower body of Korean young women into five groups according to their lower body shapes. 1) Group 1(18.9% of the total) is characterized by a shorter and thinner lower body, no dropped hip with a close size between hip and waist. 2) Group 2(21.3% of the total) is characterized by longer lower body and average dropped hip with the most differences between hip and waist size. 3) Group 3(18.6% of the total) is characterized by their average hip and waist sizes but with the most dropped hip. 4) Group 4(22.9% of the total) is characterized by their comparatively fat lower body, almost average dropped hip and more differences between hip and waist size. 5) Group 5(19.2% of total) is characterized by the fattest and relatively longer lower body, least dropped hip with less differences between hip and waist sizes.

  • PDF

Comparison of Hip Rotation Range of Motion in Jiu-Jitsu Athletes With and Without Low Back Pain (주짓수 선수의 허리 통증 유무에 따른 엉덩관절 돌림 가동범위 비교)

  • Yang, Sung-jun;Park, Kyue-nam;Kyung, Moon-soo;Kim, Si-hyun
    • Physical Therapy Korea
    • /
    • v.25 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Background: A limited hip rotational range of motion (ROM) has been considered to be one of characteristics of low back pain (LBP) in athletes. Although LBP frequently occurs in jiu-jitsu athletes, no previous has compared hip rotational ROM between jiu-jitsu athletes with and without LBP. Objects: The aim of the study was to compare ROM for hip internal rotation (IR) and external rotation (ER), and total hip rotation between jiu-jitsu athletes with and without LBP. Methods: Jiu-jitsu athletes were recruited for the LBP group ($n_1=15$) and control group without LBP ($n_2=15$). IR, ER, and total rotational range of hip joint were measured using a goniometer. Analysis of variance was used to compare the ROM between groups and sides. Results: The LBP group showed a significantly lower range of passive hip IR, passive total rotation, active IR, active ER, and active total rotation than the control group (p<.05). Dominant side of passive hip IR and active IR had a significantly lower ROM than non-dominant side (p<.05). In passive ER ROM, non-dominant side was significantly greater than dominant side (p<.05). Conclusion: Compared to jiu-jitsu athletes without LBP, athletes with LBP exhibit a loss of hip rotational ROM. Based on these results, clinicians and athletic trainers should measure hip rotational ROM when designing the management plan for jiu-jitsu athletes with LBP.

A Study on the Contact Stress Analysis of the Artificial Hip Joint Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • 김청균;윤종덕
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.189-194
    • /
    • 1996
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires the re-replacement of the hip joint beacuse it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focused on the development of the new materials. The research of new material, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find the new combination of the materials in the total hip replacement which has the excellent contact characteristics. The finite element uses MARC and the 5-node aximetric element. The results show that in case of acetabulum UHMWP has good characteristics, in femoral head, the $Al_2O_3$, and in stem, Ti6Al4V.

  • PDF

Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

  • Naik, Lokesh Gudda;Shon, Won Yong;Clarke, I.C.;Moon, Jun-Gyu;Mukund, Piyush;Kim, Sang-Min
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.276-281
    • /
    • 2018
  • Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.

The Effects of Manual Therapy using Pelvic Compression Belt on Hip Abductor Strength and Balance Ability in Total Knee Replacement Patients. (골반압박벨트를 착용한 상태에서의 도수치료가 슬관절 전치환술 환자의 고관절 외전근과 균형에 미치는 영향)

  • Shin, Young-il;Kim, Tae-won;Jeon, Jae-guk
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.1
    • /
    • pp.77-83
    • /
    • 2018
  • Background: The purpose of this study is to investigate that effect of manual therapy using pelvic compression belt on hip abductor strength and balance ability in total knee replacement (TKR) patients. Methods: The subjects consisted of twenty two post-TKR patients. Participants were randomly assigned to a pelvic belt group (n=11) and a placebo group (n=11). All participants underwent manual therapy including range of motion exercise, soft tissue mobilization around knee joint, strengthening exercise (Quad set, SLR, sidelying hip abduction, standing hamstring curls, sitting knee extension, step-up, wall slide to $45^{\circ}$ knee flexion). Manual therapy was executed five times a week for 2 weeks. Outcome measures included hip abductor strength by using Biodex system 4 pro, anterior to posterior balance, medial to lateral balance, total balance by using Biodex balance system SD. Results: After the completion of the manual therapy, hip abductor strength was showed statistically significant improvements in pelvic belt group (p<.05). Anterior to posterior balance, medial to lateral balance, total balance were showed statistically significant improvements in pelvic belt group and placebo group (p<.05). There was a statistically significant difference between the two groups in hip abductor strength and there was no statistically significant difference in balance. Conclusions: This results suggest that manual therapy using pelvic compression belt has could be used for selective muscle activation of the hip abductor muscle and has useful in hip abductor strength and balance ability in TKR patients.

A Study on the Usefulness of Total Hip Replacement Arthroplasty Using Fluoroscopy (투시하에 시행한 고관절 확대계측 촬영술의 유용성에 관한 분석)

  • Lee, H.J.;Son, S.Y.;Um, J.Y.;Chin, J.H.;Kim, K.C.
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • To make a comparative analysis for clinical application of total hip replacement arthroplasty(THRA) using fluoroscopy, we have performed total hip replacement arthroplasty making 30 patients an object with general radiography and fluoroscopy respectively. The results are as follows : 1) Reexamination rate was 80% of patients and mean 3.9 sheets in the general radiography, where as it was 46.7% and 0.37 sheets in the fluoroscopy(p<0.01) 2) Add examination was 2 cases in the general radiography, but fluoroscopy was no add examination. 3) The total film sheet used was mean 10.16 in the general radiography and 6.73 in the fluoroscopy. 4) In the cause of reexmination and add examination, inaccurate position of patient accounted for 72.6% in the general radiography and poor exposure condition accounted for 45.5% in the fluoroscopy. Total hip replacement arthroplasty using the fluoroscopy decreased reexamination and add examination rate, for these reasons, this method was effective abatement of pain, exposured radiation dose, and examination time and so on.

  • PDF