• Title/Summary/Keyword: Total harmonics distortion

Search Result 148, Processing Time 0.034 seconds

Analysis and Design Considerations for a High Power Buck Derived LED Driver with Extended Output Voltage and Low Total Harmonic Distortion

  • Lv, Haijun;Wu, Xinke;Zhang, Junming
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1137-1149
    • /
    • 2017
  • In order to reduce the cost, improve the efficiency and simplify the complicated control of existing isolated LED drivers, an improved boundary conduction mode (BCM) Buck ac-dc light emitting diode (LED) driver with extended output voltage and low total harmonic distortion is proposed. With a coupled inductor winding and a stacked output, its output voltage can be elevated to a much higher value when compared to that of the conventional Buck ac-dc converter, without sacrificing the input harmonics and power factor. Therefore, the proposed Buck LED driver can meet the IEC61000-3-2 (Class C) limitation and has a low THD. The operating principle of the topology and the design methodology of the ac-dc LED driver are presented. A 150 W ac-dc prototype was built in the laboratory and it shows that the input current harmonics meet the lighting standard. In addition, the THD is less than 16% at a typical ac input. The peak efficiency is higher than 96.5% at a full load and a normal input.

Analysis and Optimization of the Axial Flux Permanent Magnet Synchronous Generator using an Analytical Method

  • Ikram, Junaid;Khan, Nasrullah;Junaid, Qudsia;Khaliq, Salman;Kwon, Byung-il
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.257-265
    • /
    • 2017
  • This paper presents a 2-D analytical method to calculate the back EMF of the axial flux permanent magnet synchronous generator (AFPMSG) with coreless stator and dual rotor having magnets mounted on both sides of rotor yoke. Furthermore, in order to reduce the no load voltage total harmonics distortion (VTHD), the initial model of the coreless AFPMSG is optimized by using a developed analytical method. Optimization using the 2-D analytical method reduces the optimization time to less than a minute. The back EMF obtained by using the 2-D analytical method is verified by a time stepped 3-D finite element analysis (FEA) for both the initial and optimized model. Finally, the VTHD, output torque and torque ripples of both the initial and optimized models are compared with 3D-FEA. The result shows that the optimized model reduces the VTHD and torque ripples as compared to the initial model. Furthermore, the result also shows that output torque increases as the result of the optimization.

Harmonic Modeling for Power Systems (전력시스템 고조파 모델링에 관한 연구)

  • Wang, Y.P.;Chong, H.H.;Han, H.H.;Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Kim, K.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.147-148
    • /
    • 2006
  • Recently, due to increasing the application of power electronic equipment, harmonics generated from the non-liner load are fairly produced. Harmonics can cause a variety of problems such as the overheating of distribution transformer, the breakdown of device and communication interference. Interest about power quality decline of power system is very increased. In this paper, we are measured the harmonic voltage and current o( power system to analyze harmonic characteristics, and it is analyzed Total Harmonic Distortion(THD). Also, we Ere modeled power system using PSCAD/EMTDC. And it is analyzed harmonic voltage and current in steady-state. The study results have been indicated the utility about harmonics analysis and modelling for power system.

  • PDF

Harmonics Analysis in eletric railroad feed system (전철 급전계통의 고조파 실측 및 해석결과 비교검증)

  • Choi, H.K.;Yoon, J.Y.;Lee, J.W.;Oh, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.149-151
    • /
    • 2000
  • This paper compares the measurement values of harmonics to the analysis results in railroads testing system. Therefore, in this paper, new program to calculate THD(Total Harmonic Distortion) and measuring system of harmonics are developed. The harmonic measurement point is PCC(Point of Common Coupling), the primary side(154kV) of scott transformer, and the analysis is performed based on real KEPCO system data. As a result of this study, it is possible to present basic data and informations about harmonic problems which can be occurred in the future commercial railroad systems.

  • PDF

Harmonics Elimination in a Multilevel Inverter with Unequal DC Sources Using a Genetic Algorithm

  • Iranaq, Ali Reza Marami;Kouhshahi, Mojtaba Bahrami;Kouhshahi, Mehdi Bahrami;Sharifian, Mohammad Bagher Bannae;Sabahi, Mehran
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.77-83
    • /
    • 2012
  • In this paper, an optimal solution to the harmonic reduction problem in a cascaded multilevel inverter with non-equal DC sources using a genetic algorithm (GA) is presented. Switching angles are generated for different values of modulation index by the proposed algorithm, considering minimum voltage total harmonic distortion (THD) whereas selected harmonics are controlled within the allowable limits at all desired modulation indices including the point of discontinuity. Results are stored as a look-up table to be used to control the inverter for a certain operating point. The computed angles are used in a simulated circuit in Matlab\Simulink to validate the results.

The Evaluation of Medium Voltage Motor's Current and Voltage Harmonics during Loading

  • Alboyaci, Bora;Yorukeren, Nuran
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • This paper presents the results of investigating harmonic levels on medium voltage motors at loading conditions in air separation plant. The essential results of the measurements of the medium voltage motor harmonics are summarized in the values for the total harmonic distortion (THD). Motors loading case is used to assess the current and voltage harmonic distortions. Proper system analysis is important when adding a new motor starting and controlling the equipment. With the result of the paper it is possible to suggest the most appropriate starting and control method. Two medium voltage motors of air separation unit measurement results and simulations are summarized. Both current and voltage harmonic distortions are fitted by using a linear and exponential regression model. The prediction of THD values can be used for this kind of process for future planning by utilities.

The Harmonic Analysis for Inverter related with PCR (PCR과 인버터의 결합에 의한 고조파 해석)

  • Kang, Seol-Moog;Koo, Bon-Ho;Kwen, Wu-Hyen;Kim, Soo-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.779-781
    • /
    • 1987
  • In phase controlled rectifier(PCR), harmonica are changed according to the variation of a firing angle. These harmonics are supplied with the input of the inverter. And then, inverter output comes about the harmonics combined with the switching frequency of the inverter. Hence the efficiency of the induction motor ia decreased by the harmonic of the inverter output. In this paper, it analyzed about an effect of these harmonics ia analyzed by a computer simulation. The total harmonic distortion (THD) in the case of PCR containing the ripple was considerably larger than THO of the DC source. Therefore, it was proved that the firing angle variation of PCR had to be limited.

  • PDF

Three-Phase Reference Current Generator Employing with Kalman Filter for Shunt Active Power Filter

  • Hasim, Ahmad Shukri Abu;Ibrahim, Zulkifilie;Talib, Md. Hairul Nizam;Dardin, Syed Mohd. Fairuz Syed Mohd.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.151-160
    • /
    • 2017
  • This paper presents a new technique of reference current generator based on Kalman filter (KF) estimator for three-phase shunt active power filter (APF). The stationary reference frame (d-q algorithm) is used to transform the load currents into DC component. The harmonics of load currents are extracted and the three-phase reference currents are generated using KF estimator. The work is simulated using Matlab/Simulink platform. To validate the simulation results, an experimental test-rig have been perform using real-time control dSPACE DS1104. In addition, hysteresis current control was used to generate the switching signal for the correction of the harmonics in the system. The non-linear load were constructed with three-phase rectifier which connected in series with inductor and parallel with resistor and capacitor. The results shows that the new technique of shunt APF embedded with KF is proven to eliminate the harmonics created by the non-linear load with some improvement on the total harmonics distortion (THD).

A Study on the Harmonics of Distribution Power System Interconnected with Distributed Generation (분산전원의 배전계통 연계 시 발생하는 고조파에 관한 연구)

  • Park, Jae-Gyun;Kim, Jin-Sung;Oh, Yong-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • In this paper, the analysis of the harmonics of distribution power system interconnected with DG(distributed generation) is simulated by using PSCAD/EMTDC and evaluated the harmonics. The modeling system for simulation is similar to the actual distribution system, and solar power system. The simulation analyses are performed at connection points for each sector. Harmonic standards of interconnection with DG (IEEE Std 1547 and IEEE Std 519) are applied to the evaluation algorithm, converted the simulated data through FFT method, evaluated by THD and TDD separately. The harmonic contents in the case of without DG and each sector with DG are evaluated and compared. The results of evaluation showed the effect that the harmonic contents are appropriated at all sector with DG (without DG) in the distribution power systems but the large induction motor(50KW) is increased the harmonic contents.

Advanced Static Over-modulation Scheme using Offset Voltages Injection for Simple Implementation and Less Harmonics

  • Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.138-145
    • /
    • 2015
  • In this paper, a novel static overmodulation scheme (OVM) for space-vector PWM (SVPWM) is proposed. The proposed static OVM scheme uses the concept of adding offset voltages in linear region as well as overmodulation region to fully utilize DC-link voltage. By employing zero sequence voltage injection, the proposed scheme reduces procedures for achieving SVPWM such as complicated gating time calculation. In addition, this paper proposes a stepwise discontinuous angle movement in high modulation region in order to reduce Total Harmonic Distortion (THD). The validity of the proposed scheme is verified through theoretical analysis and experimental results.