• 제목/요약/키워드: Total harmonic distortion improvement

검색결과 38건 처리시간 0.03초

평균전류모드 플라이백 토폴로지를 이용한 PDP용 고효율 AC-DC 컨버터 및 Hold-up 특성 개선 (High Efficiency AC-DC Converter Using Average-Current Mode Flyback Topology for PDP and Improvement of Hold-up Characteristic)

  • 이경인;임승범;정용민;오은태;이준영
    • 반도체디스플레이기술학회지
    • /
    • 제7권2호
    • /
    • pp.23-27
    • /
    • 2008
  • Recently, regulation for THD (Total Harmonic Distortion) such as IEC 61000-3-2, IEEE 519 is being reinforced about a product which directly connects to AC line in order to prevent distortion of common power source in electronic equipment and electrical machinery. In order to satisfy these regulations, conventional circuits were used two-stage structure attached power factor correction circuit at ahead of converter but this method complicate the circuit and then a number of element increases thereupon the cost of production rises. in this paper, we propose a high efficiency single-stage 300W PFC fly-back converter that improved power factor and efficiency than conventional two-stage power module.

  • PDF

모듈형 멀티레벨 컨버터의 전고조파 왜곡률을 개선하기 위한 옵셋 전압을 이용한 모듈레이션 기법 (New Modulation Scheme of Modular Multi-level Converter using Offset-voltage Control for THD Improvement)

  • 김도현;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.127-128
    • /
    • 2016
  • 본 논문에서는 모듈형 멀티레벨 컨버터(Modular Multi-level Converter)의 전고조파 왜곡률(Total Harmonic Distortion)을 개선하기 위한 새로운 모듈레이션 기법에 대해서 기술하고 있다. 제안하는 모듈레이션 기법의 타당성을 검증하기 위해 PSCAD/EMTDC 소프트웨어를 이용하여 시뮬레이션을 수행하였으며, 한 암당 12개의 서브모듈로 구성된 모듈형 멀티레벨컨버터 모델을 개발하였다. 이를 통하여 제안하고자하는 옵셋 전압 방식의 모듈레이션 기법을 적용하고 타당성을 분석하였다. 또한 시뮬레이션을 통해 분석한 내용을 실험적으로 검증하기 위해 10kVA 용량의 하드웨어 축소모형을 제작하고 실험을 실시하였다.

  • PDF

병렬형 Z-소스 능동필터에 의한 배전계통의 전압 %THD 개선 (Voltage %THD Improvement of Distribution System by Shunt Z-Source Active Filters)

  • 오승열;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.86-89
    • /
    • 2007
  • 본 연구에서는 배전계통의 전압 고조파 확산에 따른 전압 %THD (%Total Harmonic Distortion)를 개선하기 위한 Z-소스 능동필터(Z-AFU : Z-Source Active Filter Unit)를 제시하였다. 버스(Bus)의 전압 고조파는 60Hz 버터워쓰 저역통과필터(LPF)에 의하여 검출하였다. 제안된 시스템의 보상전원으로는 고분자 전해질 연료전지(PEMFC)를 사용하였다. 제안된 시스템의 타당성을 확인하기 위하여 PSIM 시뮬레이션을 수행하였으며, 전압 고조파 확산 억제에 따른 배전계통 전압의 %THD를 개선 할 수 있었다.

  • PDF

Analysis, Design and Development of a Single Switch Flyback Buck-Boost AC-DC Converter for Low Power Battery Charging Applications

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.318-327
    • /
    • 2007
  • The design and performance analysis of a power factor corrected (PFC), single-phase, single switch flyback buck-boost ac-dc converter is carried out for low power battery charging applications. The proposed configuration of the flyback buck-boost ac-dc converter consists of only one switch and operates in discontinuous current mode (DCM), resulting in simplicity in design and manufacturing and reduction in input current total harmonic distortion (THD). The design procedure of the flyback buck-boost ac-dc converter is presented for the battery charging application. To verify and investigate the design and performance, a simulation study of the flyback buck-boost converter in DCM is performed using the PSIM6.0 platform. A laboratory prototype of the proposed single switch flyback buck-boost ac-dc converter is developed and test results are presented to validate the design and developed model of the system.

AC-AC Voltage Regulator Conditioning Converter with Three Control Schemes

  • Ahmed, Nabil A.;Miyatake, Masafumi;Kang, Ju-Sung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.169-173
    • /
    • 2005
  • In this paper, a comparative study of modified phase-angle, extinction-angle, and pulse width modulation control techniques for the purpose of power factor improvement of single-phase AC-AC voltage regulators have been illustrated as applied to a single-phase ac voltage converter by an example of the widely used single-phase induction motor as a dynamic load. Observations on power factor, displacement factor and total harmonic distortion factor are described and discussed on the basis of the simulated and measured results of this work.

  • PDF

Improved Active Power Filter Performance Based on an Indirect Current Control Technique

  • Adel, Mohamed;Zaid, Sherif;Mahgoub, Osama
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.931-937
    • /
    • 2011
  • This paper presents a method for the performance improvement of a shunt active power filter (SAPF) using the indirect current control (ICC) scheme. Compared to the conventional direct current control (DCC) scheme, the ICC gives better performance with a lower number of sensors. A simplified and efficient control algorithm using a low cost Intel 80C196KC microcontroller is implemented using only two current sensors for the source current and one voltage sensor for the DC-link voltage of the SAPF circuit. The objective is to eliminate harmonics and to compensate the reactive power produced by non-linear loads such as an uncontrolled rectifier feeding an inductive load. The APF is realized using a three phase voltage source inverter (VSI) with a dc bus capacitor. Experimental results are presented to prove the better performance of the ICC method over the DCC one.

무선 전송방식의 홈시어터 설계 및 이의 성능 분석 (A Design and Analysis on Performance of Wireless Home Theater System)

  • 강경원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.181-182
    • /
    • 2007
  • Wireless home theater and speaker system was designed. That has 20W output per channel, 0.1% THD (Total Harmonic Distortion) and automatic algorithm avoiding noise. The 3D stereophonic sound was realized through the wireless 5.1channel speaker system designed. That could be secured 0.4% improvement effect of THD compared with wire speaker systems. Specially in transfer sound with wireless, Frequency Hopping Spread Spectrum was superior than Direct Sequence Spread Spectrum in household electric appliances and wireless internet environment that radiated noise similar with ISM Band using 2.4GHz.

  • PDF

패널용 에어컨의 역률 개선 및 고조파 저감 (Power Factor Correction Improvement and Total Harmonic Distortion Reducing for Panel's Air-conditioner)

  • 박성우;박정우;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.258-261
    • /
    • 2001
  • High Power factor Active Filter converter is used for Inverter Air conditioner power supply to meet IEC standard. In the active filter topology for power factor, extra switch just control the input current indirectly to meet the IEC standard for reducing the cost and size. In this paper, low cost converter was suggested by simulation using extra switch which auxiliary pulse is inserted and quasi resonant soft switching topology control is adapted for panel's inverter air conditioner converter Inserting auxiliary Pulse method to the extra switch has the benefit of reducing THD by low cost input control circuit. And also quasi resonant soft switching topology can reduce switching loss. So both technical is suitable for Panel's Air conditioner.

  • PDF

형광등용 전자식 안정기의 설계 (The Design of Fluorescent Lamp Electronic Ballast)

  • 이은학;장준영;박창훈;송요창
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.34-39
    • /
    • 2004
  • Fluorescent lamp operated at high frequency by the electronic ballast provide ballasts like unnoticed flicker effect and higher luminous efficiency. This paper presents analysis of Half-Bridge type resonant inverter for Fluorescent lamp drive for stable characteristic and life improvement of lamp operated at high frequency. Also, it has described an electronic ballast design with the capability of high PF (Power Factor) and low THD (Total Harmonic Distortion). The validity of designed electronic ballast circuit is confirmed by simulation and experimental results. The Designed electronic ballast is implemented successfully on 32W Fluorescent lamp system.

  • PDF

3-Level NPC 인버터에서의 THD 개선을 위한 Zero Dead-time PWM 구현기법 (Zero Dead-time PWM realization Method to Improvement for Total Harmonic Distortion in 3-Level NPC Inverter)

  • 간용;현승욱;홍석진;이희준;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.59-60
    • /
    • 2015
  • 본 논문에서는 3-Level NPC(Neutral Point Clamped) 인버터에서 ZDPWM(Zero Dead Time Pulse Width Modulation) 기법에 대해서 제안한다. 3-Level NPC 인버터에서 기존 PWM 기법은 각 스위치는 서로 상보적인 동작을 수행하고, 반도체 스위칭 소자 특성상 Rise Time과 Fall Time의 시간차이로 인하여 단락사고를 방지하기 위해 스위칭 신호의 Rising Edge에 데드타임을 인가하여 단락을 방지한다. 그러나 이러한 데드타임은 지령 스위칭 신호와 실제 스위칭 신호의 오차로 인하여 출력 전압 및 전류에 왜곡이 발생하고, 이러한 왜곡으로 인하여 시스템의 오작동 및 직류링크단 전압의 불평형의 원인이 된다. 제안하는 PWM기법은 지령전압과 출력전류의 위상에 따라 영역을 나눈 후 전류의 방향에 따라 옵셋 전압을 생성하여 새로운 지령전압을 만들어 각 스위치에 스위칭 신호를 인가한다. 제안한 기법에 타당성을 증명하기 위해 시뮬레이션을 통해 검증하였다.

  • PDF