• Title/Summary/Keyword: Total fine system

검색결과 167건 처리시간 0.025초

Ultra high precision Dual stage system Using Air bearing and VCM for Nano level Scanning (VCM을 이용한 나노 정밀도 스캐닝 용 초정밀 이중 스테이지)

  • Kim Ki-Hyun;Gweon Dae-Gab;Choi Young-Man;Kim Dong-Min;Nam Byoung-Uk;Lee Suk-Won;Lee Moon-Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제22권5호
    • /
    • pp.103-112
    • /
    • 2005
  • This paper presents one-axis high precision scanning system and illustrates the design of modified $X-Y-{\theta}$ stage as a tracker using VCM and commercialized air bearings for it. The scanning system for 100nm resolution is composed of the 3-axis stage and one axis long stroke linear motor stage as a follower. In this study a previous proposed and presented structure of VCM for the fine stage is modified. The tracker has 3 DOF($X-Y-{\theta}$ motions by four VCM actuators which are located on the same plane. So 4 actuating forces are suggested and designed to create least pitch and roll motions. This article will show about the design especially about optimal design. The design focus of this fine stage is to have high acceleration to accomplish high throughput. The optimal design of maximizing acceleration is performed in restrained size. The most sensitive constraint of this optimal design is heat dissipation of coil. There are 5 design variables. Because the relationship between design variables and system parameters are quite complicated, it is very difficult to set design variables manually. Due to it, computer based optimal design procedure using MATLAB is used. Then, this paper also describes the procedures of selecting design variables for the optimal design and a mathematical formulation of the optimization problem. Based on the solution of the optimization problem, the final design of the stage is also presented. The results can be verified by MAXWELL. The designed stage has the acceleration of about 5 $m/s^{2}$ with 40kg total mass including wafer chuck and interferometer mirror. And the temperature of coil is increased $50^{\circ}C$. In addition, the tracker is controlled by high precision controller system with HP interferometer for it and linear scaler for the follower. At that time, the scanning system has high precision resolution about 5nm and scanning resolution about 40nm in 25mm/s constant speed

Studies on the Distribution of Heavy Metal Concentrations in Ambient Suspended Particulate Matters Using the X-ray Fluorescence Spectroscopy (X-선 형광분광법을 이용한 대기부유분진중 중금속의 농도분포에 관한 연구)

  • 이태정;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.20-28
    • /
    • 1992
  • The x-ray fluorescence(XRF) is one of the most convenient and widely used techniques for analyzing trace elements in ambient particulate matters. The objects of the study were to estimate the optimum exposure time using the XRF, to investigate the distributions of heavy metal levels in particulate matters, and finally to study seasonal variation for the concentrations of total suspended particulate matters(TSP) and size fractionated particulate matters. The suspended particulate matters had been collected by a cascade impactor having 9 size fragnated stages for 3 years(Dec. 1988 to Nov. 1991) in Kyung Hee University-Suwon Campus. The particulate matters were then collected on each stage by membrane filters. The weight concentrations were determined by the XRF system. Thus, seasonal variations and relationship between concentration and particle size could be investigated. Resulting distribution was bimodal with the coarse and the fine particle groups minimum occurring around 2.1 to 3.3 $\mu$m as an aerodynamic diameter. To determine optimum exposure time of the XRF for various trace inorganic elements, membrane filters and the NIST standard filters were extensively studied. Using a statistical technique, optimum exposure time was estimated for each trace element and overall elements. The time was then determined as 20 seconds for the XRF system. The concentration of TSP was 123.9$\mum/m^3$ on an arithmatic average. The levels of each inorganic metal were Si 2420.0ng/$m^3$, Fe 977.1ng/$m^3$, and so on. The Pb. Zn, and Cu abounded in the fine mode group, while Ca, Fe, Si, Al, and K in the coarse group. Marked seasonal variation of TSP and metal concentrations was observed. The concentration of heavy metals in the fine mode was highest in winter : on the other hand, that in the coarse mode was highest in spring.

  • PDF

On-road Investigation of PM Emissions of Diesel Aftertreatment Technologies (DPF, Urea-SCR) (차량 추적 실험을 통하여 디젤 후처리 장치가 입자상 물질 배출에 미치는 영향 파악)

  • Lee, Seok-Hwan;Kim, Hong-Seok;Park, Jun-Hyuk;Cho, Gyu-Baek
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제19권5호
    • /
    • pp.92-99
    • /
    • 2011
  • To measure the traffic pollutants with high temporal and spatial resolution under real conditions, a mobile emission laboratory (MEL) was designed. The equipment of the mini-van provides gas phase measurements of CO, NOx, $CO_2$, THC (Total hydrocarbon) and number density & size distribution measurements of fine and ultra-fine particles by a fast mobility particle sizer (FMPS) and a condensation particle counter (CPC). The inlet sampling port above the bumper enables the chasing of different type of vehicles. This paper introduces the technical details of the MEL and presents data from the car chasing experiment of diesel bus equipped with aftertreatment system. The dilution ratio was calculated by the ratio of ambient NOx and tail-pipe NOx. Most particles from the diesel bus were counted under 300 nm and the peak concentration of the particles was located between 30 and 60 nm. The total PM number emission from diesel bus equipped with DPF was 10 orders of magnitude lower compared to those emitted from base diesel bus. And the total PM number emission from diesel bus equipped with SCR was comparable to the particle emission from base diesel bus.

X-ray Induced Electron emission Spectroscopy

  • 송세안;이재철;최진학;김준홍;이재학;임창빈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.191-191
    • /
    • 1999
  • Extended X-ray Absorption Fine Structure (EXAFS)는 일반적으로 널리 사용하는 X선 회절분광기로 분석하기 힘든 chemical 또는 biological system의 structural analyses에 매우 유용한 분석방법이다. 특히 세라믹이나 유전체 비정질 재료의 미세 원자 구조에 관한 정보를 얻는데는 가장 강력한 분석방법중의 하나로 알려져 있다. 현재까지 대부분의 EXAFS 실험은 방사광 가속기를 이용하여 수행하였다. 그런데 신제품 개발의 순환주기가 급속하게 단축되는 현실적인 문제에 부응하기 위하여 실험실에서 EXAFS 실험을 수행할 수 있는 system을 개발하게 되었다. 개발한 XIEES 장비는 rotating anode 형의 18kW X-ray source, Optical system, Detection system, Stepping motor control system, vacuum system, Utility 등으로 구성하였다. Optical system에서의 6개의 Johanson type monochromator를 사용하여 분석가능한 x-ray energy range를 480eV에서 41keV까지 구현하였다. 이는 산소에서 우라늄까지 분석이 가능함을 의미하는 것으로, 산화물 연구에 많이 활용할 것으로 기대한다. XIEES는 투과 및 형광 X-ray를 검출할 수 있는 기능과 X-ray에 의해 여기 되는 모든(광전자, Aiger 전자, 이차전자)들을 검출할 수 있는 기능을 갖추고 있는데 이를 Total Electron Yield 측정이라고 한다. Total Electron Yield 측정은 박막 시료와 같이 투과가 되지 않는 시료를 분석할 뿐만 아니라, 경원소 분석, 낮은 에너지에서 흡수 edge가 나타나는 L-edge 측정을 통한 전자 구조 분석 등에 유용한다. 실험실용 XIEES 장비는 방사광가속기에 비해 x-ray flux가 크게 뒤지는 문제와 Total Electron Yield를 측정하는 데 있어서 source에서 나오는 x-ray beam이 진공용기 안에서 산란되어 이차전자를 여기하고 이 이차전자들이 전자검출기에 유입되어 측정에 영향을 미치는 background 문제 등이 있다. 이 두 가지 문제를 해결하기 위하여 Capillary tube를 사용하였다. 본 연구에서는 실험실용 XIEES 장비를 소개하고 이를 이용하여 Cu standard 시료에서 측정한 EXAFS 결과와 Capillary tube를 사용하여 얻은 x-ray flux 증진 및 background 제거 효과에 대해서 발표한다.

  • PDF

Reliability Investigation of a Pump-Turbine System at Various Operating Conditions (운전조건에 따른 펌프 터빈 시스템의 안정성 연구)

  • Chen, Chengcheng;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • 제18권3호
    • /
    • pp.46-52
    • /
    • 2015
  • Pump-turbine system is widely used by the hydropower industry for stabilizing the electrical grid in the vast growing economy of most developed countries. This study only investigates the Fluid-structure Interaction (FSI) analysis of the pump-turbine system at various operating conditions. The FSI analysis can show how reliable each component of the system is by providing the engineer with a better understanding of high stress and deformation points, which could reduce the lifespan of the pump-turbine. Pump-turbine components are categorized in two parts, pressurized static parts and movable stressed parts. The fixed parts include the spiral casing, top and bottom cover, stay vane and draft tube. The movable parts include guide vanes and impeller blades. Fine hexahedral numerical grids were used for CFD calculation and fine tetrahedral grids were used for structural analysis with imported load solution mapping greater than 90 %. The maximum equivalent stress are much smaller than the material yield stress, and the maximum equivalent stress showed an increasing tendency with the varying of operating conditions from partial to excessive at both modes. In addition, the total deformation of all the operating conditions showed a small magnitude, which have quite small influence on the structural stability. It can be conjectured that this system can be safely implemented.

The Technologic Consideration of Using for DSA (DSA에 대한 기술적 고찰)

  • Cho, Young-Ki
    • Journal of radiological science and technology
    • /
    • 제17권2호
    • /
    • pp.13-20
    • /
    • 1994
  • The paper is on the record of radiography the patients with SIEMENS ANGIOSTAR/POLYTRON S PLUS angiosystem with DSA system in the Chonbuk National University Hospital from October 1993 to June 1994. The results are as follow : 1. Among the total No, 836 case of utilization, angiography are 316(37.8 %), interventional radiography are 256(34.2 %), and dacryocystography and sialography are 168(20/1 %). Therefore non-angiogrlphy procedure are incerasing. 2. The aomunt of contrast material used are half as much as conventional angiovascular system. 3. The amount of film consumed are $10{\sim}15%$ of that of conventional angio vascular system and reduction of procedure time are $40{\sim}50%$. 4. Admitting that dignostic utility is in the utilization by examination region, there should be technological study which deal with fine vessel and motion artifact problem.

  • PDF

An Exploratory Study on the Effect of LCZ Type on Particulate Matter (LCZ 유형이 미세먼지에 미치는 영향에 관한 탐색적 연구)

  • Yeonju Kim;Hansol Mun;Juchul Jung
    • Journal of Environmental Impact Assessment
    • /
    • 제32권5호
    • /
    • pp.338-352
    • /
    • 2023
  • As of 2019, Korea's fine dust is the most severe among 38 OECD countries, and in the same year, 「the Framework on Disaster and Safety Management」 was revised to define fine dust as a social disaster. Currently, the government is working to achieve its emission reduction goals by preparing a comprehensive fine dust management plan (2022-2023) consisting of a total of five areas, 42 tasks, and 177 detailed tasks. However, it is necessary to come up with measures in consideration of the various spatial characteristics of the city, not just as a source of emission. Therefore, in this study, the shape of the city was classified using the LCZ (Local Climate Zone) classification system into 17 types by building type and land cover type in Busan, and the average annual PM10 and PM2.5 concentration were mapped using the IDW technique. In addition, Fragstats and Moving Window were used to quantify the LCZ classification system. Finally, correlation analysis and regression analysis were conducted to analyze the relationship between the LCZ classification system and PM10 and PM2.5. As a result, it was confirmed that the type of low height of the building and the type of green space with trees had a positive effect on the concentration of PM10 and PM2.5. Therefore, this study is expected to be used as basic data to establish fine dust reduction policies based on efficient spatial planning.

Antioxidant Effect and Component Analysis of Cardiospermum halicacabum Leaf Extracts (풍선덩굴 잎 추출물의 항산화 효과 및 성분 분석)

  • Jeong, Hyo Jin;Kim, A Rang;Lee, Keon Soo;Park, So Hyun;Shin, Hyuk Soo;Lee, Sang Rae;Song, Ba Reum;Lee, Yun Ju;An, Hyun Jin;Lee, Jae Duk;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • 제43권2호
    • /
    • pp.175-187
    • /
    • 2017
  • In this study, the antioxidant effect and component analysis for extract and fractions of Cardiospermum halicacabum leaf were investigated. All experiments were performed with 50% ethanol extract, ethyl acetate fraction and aglycone fraction obtained from dried C. halicacabum leaf. The yields of extract and fractions were 16.4, 0.9 and 0.3% per dried powder, respectively. DPPH (1,1-phenyl-2-picrylhydrazyl) radical scavenging activity ($FSC_{50}$) of ethyl acetate fraction ($92.5{\mu}g/mL$) was the greatest radical scavenging activity, but lower than (+)-${\alpha}$-tocopherol ($8.9{\mu}g/mL$). In reactive oxygen species (ROS) scavenging activity (total antioxidant capacity, $OSC_{50}$) on ROS generated in $Fe^{3+}-EDTA/H_2O_2$ system, aglycone fraction ($4.2{\mu}g/mL$) was the highest total antioxidant capacity and similar to L-ascorbic acid ($1.5{\mu}g/mL$). The cellular protective effects of C. halicacabum leaf extract and fractions on the $^1O_2$-induced cellular damage of human erythrocytes were exhibited at all concentration-dependent ($5.0-25.0{\mu}g/mL$). Especially, aglycone fraction (${\tau}_{50}$, 76.4 min) in $25.0{\mu}g/mL$ showed the most protective effect among extracts. Components of the ethyl acetate fraction obtained from C. halicacabum extracts were analyzed by TLC, HPLC chromatogram and LC/ESI-MS. Results showed that the ethyl acetate fraction contained some flavonoids, such as apigenin-7-O-glucuronide, apigenin-7-glucosdie and quercitrin hydrate. These results suggest that the extracts and fractions of C. halicacabum leaf may be applied as antioxidant functional cosmetic raw materials.

The Economic Analysis of the Determination of Optimal Management Measures and Level of Control in Fisheries Management (불완전 어업관리의 합리적 관리수단 및 규제수준의 결정에 관한 경제학적 분석)

  • 이상고;김도훈
    • The Journal of Fisheries Business Administration
    • /
    • 제33권2호
    • /
    • pp.31-48
    • /
    • 2002
  • This paper is aimed to analyze how to evaluate the choice of optimal management measures and level of control in fisheries management under the costly and imperfect management system by comparing with costless and perfect management system that is commonly assumed in the analysis of fisheries regulations. Fishermen would set the level of fishing efforts at the point where the marginal fishing profit for fishing effort is equal to the marginal level of fine under costly and imperfect management system. Therefore, under the case where the marginal fishing profit is higher than the marginal level of fine, the level of fishing efforts would be made at the point which is higher than the level of fishing efforts made under costless and perfect management system and is not a point where the economic profit is maximized in regulated fisheries. From this conclusion, the fishermens avoidance activities against regulations as well as the level of control in fisheries management substantially have an influence on the choice of fisheries management instruments. According to the analysis of optimal fisheries management policy, the economic profits in regulated fisheries are determined by the level of fisheries enforcement costs and total fishing profits, in which as enforcement costs increase the economic profits decrease. In addition, the economic profits vary in response to the level of control in avoidance activities. That is, as avoidance costs decrease, the economic profits increase. The determination of optimal level of control in fisheries management should be made at the point where the marginal regulation costs are equal to the marginal profits from regulated fisheries, in which marginal regulation costs are different according to the type of management measures. And the level of profits changes in response to different levels of avoidance activities. The management measure that can maximize the difference between the marginal regulation costs and marginal profits from regulated fisheries should be chosen as an optimal fisheries management instrument.

  • PDF

Collection Efficiency of a Mist Eliminator for Wet Flue Gas Desulfurization (습식 배연탈황설비용 습분제거기 포집효율 평가)

  • Kim, Moon-Won;Yook, Se-Jin;Yu, Tae U
    • Particle and aerosol research
    • /
    • 제14권3호
    • /
    • pp.73-80
    • /
    • 2018
  • Recently, there has been much research on the effect of ultrafine dust on human body with increasing interest in the ultrafine dust. In the Republic of Korea, there are many old thermal power plants, and the amount of ultrafine dust emitted from the thermal power plants is reported to be about 14% of the total amount of domestic fine dust. Therefore, the amount of fine dust from the flue gas desulfurization facility in the thermal power plant needs be reduced. In this study, we made an experimental setup to simulate a flue gas desulfurization facility and analyzed the physical characteristics of the particles passing through a mist eliminator. Experiments were carried out to investigate the collection efficiency of the mist eliminator by using the Arizona Test Dust in a dry environment, and then spraying limestone slurry into the flue gas desulfurization system equipped with the mist eliminator to examine the size and morphology of limestone particles upstream and downstream of the mist eliminator. Cut-off size of the mist eliminator was formed at about $6{\mu}m$. The result of this study is expected to be helpful for designing an electrostatic precipitator for removing particles passing through the mist eliminator.