• 제목/요약/키워드: Total estimation

검색결과 2,461건 처리시간 0.041초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

질소수지에 의한 환경특성과 영농방법별 벼농사의 수질영향 평가 (Estimation of Rice Cultivation Impacts on Water Environment with Environmental Characteristics and Agricultural Practices by Nitrogen Balances)

  • 노기안;김민경;고병구;김건엽;심교문;이덕배
    • 한국토양비료학회지
    • /
    • 제42권6호
    • /
    • pp.439-446
    • /
    • 2009
  • 벼농사가 수질에 미치는 영향을 평가하기 위하여 지역별 논의 질소수지를 평가하였다. 질소의 유입량은 비료 시용량, 강우 및 관개에 의한 수계공급량, 토양질소의 무기화량 및 질소 고정량 등을 합하여 추정하였고, 질소의 유출량은 배출수나 지하침투수를 통한 수계유출량, 암모니아 휘산과 탈질에 의한 대기 중으로의 손실량, 무기질소의 유기화 및 작물에 의한 흡수량을 합하여 평가하였다. 지역별 환경 특성은 토양 중 유기물함량, 쌀 수확량, 관개수 중의 질소함량, 토양통 분포면적에 의한 토양침투속도 등을 이용하여 추정하였다. 지역별로 환경특성을 고려하여 벼농사가 수질에 미치는 영향을 평가한 결과 경기도와 충청남도의 질소 수지가 각각 -5.4와 $-8.3kg\;ha^{-1}\;yr^{-1}$으로 이 지역에서의 벼농사는 주변 수계로부터 질소를 흡수하여 농업에 활용하는 수질정화의 기능이 다른 지역에 비해 상대적으로 큰 것으로 평가되었다. 반면 강원도와 경상남도는 각각 4.9와 $14.0kg\;ha^{-1}\;yr^{-1}$ 으로 유입량보다 유출량이 오히려 많아 질소를 배출하는 것으로 평가되었다. 시비량이 $110kg\;ha^{-1}$로 동일하다는 조건하에 우리나라 관개수 중의 질소함량이 평균 $1mg\;L^{-1}$ 증가할 경우 벼농사는 $-2.9kg\;ha^{-1}\;yr^{-1}$의 수질 개선효과가 있으며, 전국적으로는 벼논의 질소 흡수량이 연간 2,616 Mg이나 증가하는 것으로 추정되었으며, 농업용수의 오염도가 상대적으로 높은 도시인근 지역이 관개수가 깨끗한 지역보다 벼농사에 의한 수질정화 효과가 크다는 것을 알 수 있었다. 동일한 수확량 조건에서 시비량을 $110kg\;ha^{-1}$에서 $90kg\;ha^{-1}$으로 줄일 경우 질소정화 기능은 전국적으로 10,600 Mg이 증가하고 수질정화 기능을 수행하는 면적도 확대됨을 알 수 있었다. 또한, 쌀 수확량 $5,000kg\;ha^{-1}$을 100%로 가정할 경우 질소 시비량은 $110kg\;ha^{-1}$, 수확량이 100%인 경우 질소수지는 $-0.3kg\;ha^{-1}$이었지만 시비량을 $90kg\;ha^{-1}$으로 줄이고 수확량도 100%에서 90%와 85%로 줄이면 질소수지는 각각 -11.7, -2.3 및 $2.4kg \;ha^{-1}$으로 시비량을 줄여도 수확량을 동시에 줄이면 질수수지의 개선효과가 떨어지며, 수량을 85%로 줄이면 수질에 미치는 영향을 나타내는 질소수지는 $110kg\;ha^{-1}$을 시비할 때보다 오히려 더 나빠지는 것으로 평가되었다. 이상의 결과들로 볼 때 벼농사가 수질환경에 미치는 영향은 관개수 수질, 토양물리 및 화학성 등의 자연환경에 따라 달라지므로 지역의 자연환경 특성을 최대로 활용하여, 벼 재배에 의한 수질정화기능을 최대로 활용하는 영농기술도입이 필요한 것으로 판단된다. 또한 현재 시비량을 줄이고 이에 따라 수확량도 줄어들 것이라는 전제의 영농방법으로서는 벼농사에 의한 수질오염 방지를 효과적으로 달성할 수 없으며, 시비량은 줄이되 토양과 관개수 중의 영양물질을 최대한으로 활용하여 최고의 수확량을 유지하는 것이 벼농사의 주변 수계에 대한 오염물질 발생을 줄이고 수질정화 기능을 증대시키는 가장 좋은 친환경농업라고 판단된다.

청보리 및 호밀 Silage를 이용한 거세한우 비육중기용 TMR의 소 체내 이용성 조사 (Estimation of Availability of Whole Crop Barley and Rye Silage TMR in the Cattle)

  • ;김광림;김종규;오영균;이상철;송만강
    • 한국초지조사료학회지
    • /
    • 제30권4호
    • /
    • pp.343-354
    • /
    • 2010
  • 본 연구는 국내에서 생산된 주요 동계 사료 작물인 청보리 및 호밀 사일리지를 이용하여 거세 한우의 비육 중기용으로 조제된 TMR의 소 체내 이용성을 배합사료 및 볏짚으로 구성된 관행 사료와 비교하고자 반추위 누관이 장착된 소 3두를 이용하여 3 $\times$ 3 Latin square design 방법으로 실시되었다. 관행사료 급여구(대조구)에는 1일 두당 7kg (비육 중기용 배합 사료 5.6kg 및 볏짚 1.4kg, 건물 기준)을, 그리고 청보리 사일리지 TMR구(BS-TMR) 및 호밀 사일리지 TMR구(RS-TMR)에는 1일 두당 8kg (건물 기준)을 각각 동일한 양으로 2등분하여 2회(08:00 및 18:00)에 걸쳐 급여하였다. 두 종류의 사일리지 TMR 모두에 각각 기타 원료사료와 사일리지를 80:20의 비율(급여상태 기준)로 혼합하여 조제하였다. 반추위액의 pH는 전체 채취시간에 걸쳐 시험사료간 유의적인 차이는 없었지만 대조구 사료에 비하여 사일리지 TMR 급여구에서 다소 높은 경향을 보였으며, 암모니아 농도 역시 처리간 차이가 없었으나 사료 급여 후 3시간부터 청보리 사일리지를 급여한 소의 반추위액에서 다소 낮은 경향을 보였다. 반추위액의 총 VFA 농도는 사료 급여 후 6시간 까지 다른 처리구에 비하여 호밀사일리지 TMR (RS-TMR)을 급여한 처리구에서 상대적으로 높았다. 반추위액의 acetate의 조성 비율은 반추위액의 모든 채취시간에 걸쳐 TMR을 급여한 처리구에서 높은 경향을 보였으며, 대조구인 관행사료 급여에 비하여 TMR 사료 급여 직전(P<0.005) 및 급여 후 9시간(p<0.048)에서 현저히 높은 비율을 보였다. Propionate 조성 비율의 경우 사료 급여 후 1시간에 대조구 사료에 비하여 사일리지 TMR을 섭취한 소에서 높은(p<0.046) 반면 butyrate 조성 비율은 대조구에서 다소 높은 경향을 보였으며, 사료급여 1시간 후에 TMR 사료 급여구에 비하여 현저히(p<0.029) 높은 것으로 나타났다. 다른 사료에 비하여 호밀 사일리지 TMR에서 건물유효분해율(EDDM) 및 조단백질 유효분해율(EDCP)이 높은 경향을 보였다. 또한 NDF의 경우 관행사료에 비하여 청보리 및 호밀 사일리지 TMR에서 높은 b 값(p< 0.039) 및 c 값(p<0.006)으로 인하여 TMR의 유효분해율(EDNDF)이 관행사료보다 높은(p< 0.049) 것으로 나타났다. 조사된 모든 주요 성분(DM, CP, EE 및 NDF)에서 관행사료에 비하여 사일리지 TMR의 전장소화율이 다소 높았으며, TMR 중 호밀 사일리지 TMR (RS-TMR)의 소화율이 NDF를 제외한 성분에서 청보리 사일리지 TMR 보다 소화율이 다소 높은 경향을 보였다. 본 시험 결과를 종합하면, 청보리 또는 호밀 사일리지 TMR의 체내 영양소 이용율이 관행 사료에 비하여 다소 개선된 결과를 보였는데, 이는 TMR이 반추위 내 발효 안정화에 기여하였으며 아울러 TMR의 섬유소 소화율이 더 개선되었기 때문인 것으로 여겨진다. 그러나 동계사료작물 사일리지의 품질이 사료작물의 수확시기 등에 따라 달라질 수 있으므로 향후 이 점이 고려된 동계사료작물 TMR의 소 체내 이용성 조사가 필요한 것으로 사료된다.

농민이촌(農民離村)과 농업인구(農業人口)의 변화(變化) (Rural Migration and Changes of Agricultural Population)

  • 오총현;김경호
    • 농업과학연구
    • /
    • 제1권1호
    • /
    • pp.91-116
    • /
    • 1974
  • 최근(最近) 십여년간(十餘年間) 대만(台灣)의 상공업(商工業)은 급속(急速)한 성장(成長)을 이룩하여 오면서 농공상간(農工商間)의 소득(所得)의 격차가 날로 커져만 왔다. 이러한 경제수입(經濟收入)의 격차는 농민사회(農民社會)에 심리적(心理的)인 불안(不安)한 요소(要素)로 등장(登場)하면서 부터 결과적(結果的)으로는 농민이촌(農民離村)에 따른 전업(轉業)의 현상(現象)을 낳게 한 것이다. 통계(統計)에 의(依)하면 1960년지(年至) 1969년간(年間) 대만(台灣)의 십대도시(十大都市)에 있어서의 인구(人口)의 평균증가율(平均增加率)을 보면 4.05%로 나타났으며 기여지역(其餘地域)은 2.06%로 나타나 있는 것이다. 만약(萬若)에 도시(都市)와 농촌(農村)과의 인구자연증가율(人口自然增加率)이 양자균등(兩者均等)하다고 가정(假定)할 경우(境遇) 위에 언급(言及)한 도시인구(都市人口)의 증가현상(增加現象)은 마땅히 농촌인구(農村人口)가 도시(都市)로 유입(流入) 되었다고 보아야 할 것이다. 오늘날 농업인구(農業人口)의 대량외류(大量外流)는 사회경제문제(社會經濟問題)를 보다 복잡(複雜)하고 광범(廣汎)하게 하였으며 이러한 현상(現象)은 결국(結局) 농촌(農村)의 젊은 청년층(靑年層)의 생산자(生産者)가 외류(外流)의 주종(主宗)을 이뤄 자연(自然) 농업생산력(農業生産力)을 저하(低下)시키는 현상(現象)을 초래(超來)케 되었다. 동시(同時)에 도시(都市)에는 주거(住居), 교통(交通), 질서문제등(秩序問題等)이 사회문제(社會問題)로 대두되게 된 것이다. 반면(反面) 농업인구(農業人口)의 외류(外流)는 그 구조(構造)가 비대(肥大)해 가고 있는 상공업(商工業) 분야(分野)에 보다 많은 노동력(勞動力)을 제공(提供)할 수 있으며 농업인구(農業人口)의 상대적(相對的)인 감소(減少)로 하여금 농장경영규모(農場經營規模)를 확대(擴大)시킬 수 있는 하나의 기회(機會)로 잡아 봄직도 한 것이다. 본문(本文)은 농업인구(農業人口)의 유출량(流出量)은 농업발전(農業發展) 및 농촌지도사업(農村指導事業)과는 상호(相互) 어떤 관계(關係)가 있나에 분석(分析)의 중점(重点)을 두었으며 구체적(具體的) 연구(硏究) 목적(目的)으로는; 1. 도시(都市)와 농촌인구구조(農村人口構造)의 비교(比較) 2. 농업인구(農業人口)의 변화(變化) 및 추계(推計) 3. 농업발전(農業發展) 및 농촌지도(農村指導)에 대(對)한 영향(影響)이며 결론(結論) 및 건의사항(建議事項)으로 1. 이촌농가(離村農家)에 대(對)한 지도책등(指導策等)을 마련하여 그들로 하여금 그들의 토지(土地)를 전업농(專業農)에게 양도(讓度)토록 유도(誘導)한다. 2. 경영규모(經營規模)의 확대(擴大)를 원(願)하는 농가(農家)에 대(對)한 정부(政府)의 자금지원(資金支援). 3. 농촌지도사업내(農村指導事業內)에 이촌전업자(離村轉業者)를 위(爲)한 비농업직업훈련과정(非農業職業訓練課程)의 증설(增設). 4. 평형적(平衡的)인 농촌인력자원(農村人力資源)의 확보(確保) 및 이의 유효적절(有效適切)한 운용(運用)으로 농업(農業) 및 농촌발전(農村發展)을 촉진(促進)시키기 위(爲)한 적량농촌인구정책(適量農村人口政策)의 입안(立案)(optimum population policy).

  • PDF

우리나라 은행산업(銀行産業)의 효율성분석(效率性分析)과 제도개선방안(制度改善方案) (Scale and Scope Economies and Prospect for the Korea's Banking Industry)

  • 좌승희
    • KDI Journal of Economic Policy
    • /
    • 제14권2호
    • /
    • pp.109-153
    • /
    • 1992
  • 본고(本稿)에서는 우리나라 은행산업(銀行産業)의 트랜스로그비용함수(費用函數)와 규모(規模) 및 범위(範圍)의 경제성(經濟性), 비용(費用)의 보완성(補完性) 그리고 경쟁적(競爭的) 생존력(生存力) 등 효율성지표들을 추정함으로써 은행산업(銀行産業)의 효율성(效率性)을 평가하고 제도개선방향(制度改善方向)에 대한 시사점을 논하였다. 추정결과에 의하면, 우선 규모(規模)의 경제성(經濟性)의 경우는 은행대출(銀行貸出)이 규모(規模)의 비경제하(非經濟下)에 있고 모든 다른 업무(業務)들은 규모(規模)의 경제(經濟)를 시현하고 있지만, 전업무에 걸친 규모(規模)의 경제(經濟)는 부재(不在)하는 것으로 관찰된다. 다음, 범위(範圍)의 경제(經濟)의 경우는 유가증권투자(有價證券投資)와 신탁자산(信託資産) 및 수신(受信) 등은 범위(範圍)의 경제하(經濟下)에 있는 반면, 은행예금(銀行預金)은 범위(範圍)의 비경제하(非經濟下)에 있고 전업무에 걸친 범위(範圍)의 경제(經濟)는 강한 것으로 관찰되고 있다. 그리고 비용보완성(費用補完性)의 경우는 유가증권투자(有價證券投資)가 은행대출(銀行貸出), 예금(預金) 및 신탁업무(信託業務)와, 그리고 신탁자산운용업무(信託資産運用業務)가 은행자산운용업무(銀行資産運用業務)와 각각 비용보완관계(費用補完關係)를 보이고 있는 반면, 은행예금(銀行預金)은 특히 은행대출(銀行貸出)과 그리고 신탁자산업무(信託資産業務)와 경쟁관계에 있다. 한편 은행산업(銀行産業)에는 경쟁적(競爭的) 생존력(生存力)이 부재(不在)하는 것으로 관찰되고 있다. 이상의 결과들의 시사점을 정리하면, 우선 은행대출(銀行貸出)은 상대적으로 규모를 축소하고 여타의 모든 은행업무(銀行業務)나 신탁업무(信託業務)들은 규모를 확대함으로써 효율성제고(效率性提高)에 기여할 수 있을 것이며, 은행예금(銀行預金)과 은행주변업무는 앞으로 금융(金融)의 심화(深化)가 진행되면 여타업무에서 분리되어 각각 독립 운영될 가능성이 높다. 유가증권업무(有價證券業務)와 신탁자산(信託資産) 및 수신업무(受信業務)들을 추가확대함으로써 은행업무(銀行業務)의 효율성(效率性)이 증대될 수 있을 것으로 보여 겸업주의(兼業主義) 은행제도(銀行制度)의 타당성은 높지만, 은행산업(銀行産業)의 자연독점적인 성격은 부재(不在)하여 섣부른 규모(規模)만의 확대(擴大)는 오히려 경쟁력(競爭力)을 저하시킬 수도 있을 것이다.

  • PDF

지능형 변동성트레이딩시스템개발을 위한 GARCH 모형을 통한 VKOSPI 예측모형 개발에 관한 연구 (A Study on Developing a VKOSPI Forecasting Model via GARCH Class Models for Intelligent Volatility Trading Systems)

  • 김선웅
    • 지능정보연구
    • /
    • 제16권2호
    • /
    • pp.19-32
    • /
    • 2010
  • 학계와 금융파생상품 가격결정이나 변동성매매와 같은 실무영역 모두에서 주식시장의 변동성은 중요한 역할을 한다. 본 연구는 GARCH 모형에 기초하여 한국주식시장의 변동성을 정확히 예측함으로써 변동성매매시스템의 성과를 높일 수 있는 새로운 방법을 제시하였다. 특히, 여러 연구 자료에서 밝혀지고 있는 변동성 비대칭성개념을 도입하였다. 최근 새로 개발된 한국주식시장 변동성 지수인 VKOSPI를 변동성 대용값으로 사용한다. VKOSPI는 KOSPI 200 지수옵션의 가격을 이용하여 계산된 값으로서 옵션딜러들의 변동성 예측치를 반영하고 있다. KOSPI 200 옵션시장은 1997년 시작되었으며, 발전을 거듭하여 현재 하루 거래량이 1,000만 계약을 넘어서면서 세계 최고의 지수옵션시장으로 발전하였다. 이러한 옵션시장에 반영된 변동성을 분석하는 것은 투자자들에게 좋은 투자정보를 제공하게 될 것이다. 특히, 변동성 대용값으로 VKOSPI를 사용하면 다른 변동성 대용치를 사용할 때 발생하는 통계적 추정의 문제를 피해 갈 수 있다. 본 연구는 2003년부터 2006년의 KOSPI 200 지수 일별자료를 대상으로 최우도추정방법(MLE)을 이용하여 GARCH 모형을 추정한다. 비대칭 GARCH 모형으로는 Glosten, Jagannathan, Runke의 GJR-GARCH 모형, Nelson의 EGARCH 모형, 그리고 Ding, Granger, Engle의 PARCH모형을 포함하며 대칭 GARCH 모형은 (1, 1) GARCH 모형을 이용한다. 2007년부터 2009년까지의 KOSPI 200 지수 일별자료를 대상으로 반복적 계산과정을 통해 내일의 변동성 예측값과 오르고 내리는 변화방향을 예측하였다. 분석 결과 시장변동성과 예기치 않은 주가변동 사이에는 음의 상관관계가 존재하며, 음의 주가변동은 동일한 크기의 양의 주가변동보다 훨씬 더 큰 변동성의 증가를 가져옴을 알 수 있다. 즉, 한국 주식시장에도 변동성 비대칭성이 존재함을 보여주었다. GARCH 모형을 이용하여 내일의 VKOSPI의 등락방향을 예측하고 이를 이용하여 변동성 매매시스템을 개발하였다. 내일의 변동성이 상승할 것으로 예측되면 스트래들매수전략을 이용하고 반대로 변동성이 하락할 것으로 예측되면 스트래들 매도전략을 이용한다. 변동성의 변화방향성을 맞춘 경우에는 VKOSPI 변동분을 더하고 틀린 경우에는 변동분을 뺀 누적합을 이용하여 변동성매매전략의 총수익을 계산한다. 모형추정용 자료구간의 경우 통계적 기준인 MSPE 기준으로는 PARCH 모형의 적합도가 가장 높고, 예측방향의 적중도를 재는 MCP 기준으로는 EGARCH 모형이 가장 높은 값을 보여주었다. 테스트용 자료구간의 경우에는 PARCH 모형이 모형적합도와 내일의 변동성 등락방향 예측에서 가장 좋은 결과를 보여주었다. 모형추정용 자료구간의 경우 GARCH 모형 전체에서 매매이익을 기록하고 있고 테스트용 자료구간의 경우에는 EGARCH 모형을 제외한 GARCH 모형들이 매매이익을 보여주었다. 본 연구에서 나타난 변동성의 군집과 비대칭성 현상으로부터 변동성에 비선형성이 존재함을 알 수 있었으며, 비선형성에서 좋은 결과를 보이고 있는 인공지능시스템과 비대칭 GARCH 모형을 결합한다면 제안된 변동성매매시스템의 성과를 많이 개선할 수 있을 것으로 판단된다.

육용계에 있어서 계통간 산육능력 및 체중증가에 따른 각 부위별 증가양상 추정에 관한 연구 (Studies on the Estimation of Growth Pattern Cut-up Parts in Four Broiler Strain in Growing Body Weight)

  • 양봉국;조병욱
    • 한국가금학회지
    • /
    • 제17권3호
    • /
    • pp.141-156
    • /
    • 1990
  • 본 연구는 육용계육종개량에 필요한 기초자료를 얻기 위하여 육용계 4계통(H, T, M, A)을 306수 공시하여 성장률 및 체중증가에 따른 체중구성요소들과 산육률의 상대비율(%)을 Trial 1 (생체중:900~l,000g), Trial 2 (생체중 : 1,300~l,500g), Trial 3 (성체중 1,600~1,800g), 그리고 Trial 4 (생체중 :1.8kg 이상) 순서로 추정하였다. 공시된 Broiler는 1987년 7월 2일부터 동년 9월 13일까지 서울대학교 농과대학 가축육종 농장에서 사육되었고, 도체시험을 가하였다. 조사사항 및 방법은 전기한 바와 같다. 본 연구에서 얻어진 결과를 요약하면 다음과 같다. 1. 4계통(H, T, M, A) 각각에서 7주령 체중과 0~7까지의 사료효율 및 생존율을 살펴보면 H계통은 $2.150\pm$34.9, 2.55 및 99.7%였으며, T계통은 $2.138\pm$26.2, 2.125 및 99.7%, M계통은 $1.960\pm$23.1과 2.084 및 100.0%였고 A계통은 $2.319\pm$27.9와 2.030 및 100.0%였다. 4계통 모두 정상발육을 하였다. 2. 0~7주령까지 2주간격으로 조사한 성장률에 대한 성적을 살펴보면 2주령을 제외한 전주령에서 계통간에 뚜렷한 유의차를 보였다. 성장속도를 표시해 주는 회귀계수값 기울기 b값을 보면, bA=1.015, bH=0.968, bM=0.950, bT=0.942순으로, A계통의 경우 bA=1.015로서 유의적으로 제일 빠른 속도로 성장하고 있음을 나타내고 있다. 3. 체중구성요소들 체중증가에 따라 각부위들의 체중비율이 증가되는 부위는 다음과 같다. 우모, 복부지방 및 흉부 그러고 퇴경부 등이고, 반면에 감소되고 있는 부위는 방혈중, 두부, 가식내장 및 불가식내장이었고, 체중증가에도 큰 변화가 없는 것을 익부 및 배부이었다. 각 부위별 계통간 유의차를 보이는 것은 우모의 경우 Trial 4에서 계통간 유의차를 보였고, 각부의 경우는 Trial 3에서 계통간 유의차를 보였으며 복부지방량의 경우 Trial 1에 유의차를 보인 뒤 나머지 단계에서는 유의차를 보이지 않았다. 가식부위들 중 계통간간 유의차가 있는 것은 경부에서(Trial 2) 나타났다. 정육이 가장 많이 퇴경부와 흉부의 중량비율(%)을 살펴보면 Trial 4에서 흉부중양비율(%)은 H, T, M, A계통에서 19.2, 19.0, 19.0, 19.0%였고 퇴경부 경우는 23.0%, 23.3, 22.8 그러고 23.0%로 흉부중량비율(%)보다 퇴경부중양비율(%)이 훨씬 높게 나타났다. 체중증가에 따른 증가속도는 흉부가 머 빠른 속도로증가했다. 4. 흉부와 퇴경부의 산육률을 보면 폐부의 산육률에 있어서 계통간 유의차는 Trial 2와 Trial 4에서 산육률의 계통간 유의차를 보였다. 증가속도가 제일 빠른 T계통은 흉폐부근육위주로 개량되었다고 판단된다. Trial 4에서 각 계통간(H, T, M, A)에서 각부의 산육률을 보면 각각 77.2%, 78.9%, 73.5%, 74.8%를 나타냈으며, 퇴경부의 경우 계통간유의차를 나타내지 않았으나 H계통의 경우는 성장속도가 제일 빠르게 나타났다. 반면, 흉부에서 제일 성장속도가 빨랐던 T계통은 퇴경부 산흉율은 bT=0.775로 오히려 감소속도를 나타내고 있다. 한편 퇴경부 산육율을 H, T, M, A계통별로 살펴보면 80.3%, 78.4%. 79.7% 그리고 80.2%였다. 5. 체중구성요소들의 중상비율간의 상관근도는 계통간를 차이를 보이지 않았다. 체중구성요소중 체중과 상관정도가 높은 부위들은 방혈양, 두부, 각부, 흉부, 퇴경부등이였다. 복부지방(%)은 어느 계종에서나 주로 불가식내장과 높은 유의상관을 보였으나, 가식부위와의 상관정도는 매우 낮게 나타났다.

  • PDF

스마트폰 다종 데이터를 활용한 딥러닝 기반의 사용자 동행 상태 인식 (A Deep Learning Based Approach to Recognizing Accompanying Status of Smartphone Users Using Multimodal Data)

  • 김길호;최상우;채문정;박희웅;이재홍;박종헌
    • 지능정보연구
    • /
    • 제25권1호
    • /
    • pp.163-177
    • /
    • 2019
  • 스마트폰이 널리 보급되고 현대인들의 생활 속에 깊이 자리 잡으면서, 스마트폰에서 수집된 다종 데이터를 바탕으로 사용자 개인의 행동을 인식하고자 하는 연구가 활발히 진행되고 있다. 그러나 타인과의 상호작용 행동 인식에 대한 연구는 아직까지 상대적으로 미진하였다. 기존 상호작용 행동 인식 연구에서는 오디오, 블루투스, 와이파이 등의 데이터를 사용하였으나, 이들은 사용자 사생활 침해 가능성이 높으며 단시간 내에 충분한 양의 데이터를 수집하기 어렵다는 한계가 있다. 반면 가속도, 자기장, 자이로스코프 등의 물리 센서의 경우 사생활 침해 가능성이 낮으며 단시간 내에 충분한 양의 데이터를 수집할 수 있다. 본 연구에서는 이러한 점에 주목하여, 스마트폰 상의 다종 물리 센서 데이터만을 활용, 딥러닝 모델에 기반을 둔 사용자의 동행 상태 인식 방법론을 제안한다. 사용자의 동행 여부 및 대화 여부를 분류하는 동행 상태 분류 모델은 컨볼루션 신경망과 장단기 기억 순환 신경망이 혼합된 구조를 지닌다. 먼저 스마트폰의 다종 물리 센서에서 수집한 데이터에 존재하는 타임 스태프의 차이를 상쇄하고, 정규화를 수행하여 시간에 따른 시퀀스 데이터 형태로 변환함으로써 동행 상태분류 모델의 입력 데이터를 생성한다. 이는 컨볼루션 신경망에 입력되며, 데이터의 시간적 국부 의존성이 반영된 요인 지도를 출력한다. 장단기 기억 순환 신경망은 요인 지도를 입력받아 시간에 따른 순차적 연관 관계를 학습하며, 동행 상태 분류를 위한 요인을 추출하고 소프트맥스 분류기에서 이에 기반한 최종적인 분류를 수행한다. 자체 제작한 스마트폰 애플리케이션을 배포하여 실험 데이터를 수집하였으며, 이를 활용하여 제안한 방법론을 평가하였다. 최적의 파라미터를 설정하여 동행 상태 분류 모델을 학습하고 평가한 결과, 동행 여부와 대화 여부를 각각 98.74%, 98.83%의 높은 정확도로 분류하였다.

수도재배의 주요환경요인에 관한 해석적 조사연구 (Agronomical studies on the major environmental factors of rice culture in Korea)

  • 김영섭
    • 한국작물학회지
    • /
    • 제3권
    • /
    • pp.49-82
    • /
    • 1965
  • 우리 나라에 있어서 수도작의 안전다수를 위한 재배법, 특히 시료의 합리화를 기하기 위한 기초적 자료를 얻기 위하여 수도 독자의 영양생리적 반응, 형태형성 내지 수량구성에 대한 특징을 살펴보았으며, 우리 나라의 수도 재배환경조건(온도ㆍ일조ㆍ강수 및 토양조건)을 대국적 견지에서 인접국인 일본과 지역별로 비교 검토하였고, 그 특징으로 본 시료에 관한 개선조건을 위해 비료의 3요소와 규산 및 그 밖에 수종의 미량요소에 대하여 검토하였다. 1. 우리 나라의 최근 14개년간의 10a당 현미평균수량은 204kg인데 이에 비하여 일본은 77%, 대만은 13% 높으며, 년간평균증가량은 우리나라가 4.2kg이고, 이에 비해 일본은 81%, 대만은 62% 더 증가되고 있다. 그리고 수량의 년간변이계수는 우리 나라가 7.7%이며 일본은 6.7%, 대만이 2.5%로서 우리 나라는 년간변이가 매우 커서 생산의 안전도가 가장 낮다. 2. 풍흉고조시험성적으로 본 우리 나라 수도와 일본의 수도를 형태형성면에서 비교하여 본즉 다음과 같았다. (1) 3.3$m^2$ 당 수수는 우리 나라의 891개에 비하여 일본은 13%나 더 많고, (2) 최고분얼기의 경수는 3.3$m^2$당 우리 나라는 1150개인데 비하여 일본은 19% 더 많았으며, (3) 유효경비율은 우리 나라가 77.5%, 일본이 74.7%로서 우리 나라가 다소 높았다. 그러나 총경수가 적은데 q하여는 유효경율이 너무 낮다. (4) 신고비는 우리 나라가 85.4%이고, 일본은 96.3%로서 우리 나라의 수도가 13% 낮았다. 3. 도작기간중의 평균기온은 수원ㆍ광주ㆍ대구는 거의 동일하며, 일본의 중국지방(부산)의 그것과 비슷하였다. 즉 우리 나라 도작기간중의 기온은 일본의 서남난지에 유사한 것이었다. 4. 우리 나라의 수도이앙기는 이앙한계최저온도 13$^{\circ}C$로 보면 현행(6월 10일 경)보다 30~40일 앞당길 수 있다. 5. 우리 나라의 현행 수도작기로서는 영양생장기의 기온이 이 시기의 주대사작용인 단백대사의 적온인 20~23$^{\circ}C$ 보다 높았다. 그러나 생식생장기의 기온은 이 시기의 주대사인 당대사의 적온인 $25^{\circ}C$이상보다 높지 않다. 그러므로 온도면에서 보면 우리 나라 수도의 작기는 앞으로 당기는 것이 좋다고 고찰된다. 6. 우리 나라의 현행 수도작기로 본 기온 및 일조조건은 수도의 분얼전기에 대해서는 호조건하에 놓여 있으나, 분얼후기인 7월 중ㆍ하순 경의 일조부족과 고온다습조건은 병해, 특히 도열병의 유발원인이 되고 있다. 7. 우리 나라의 현행수도작기로 본 전국각지의 수도의 출수기는 모두 일조시간이 적은 부적당한 시기에 처해 있다. 8. 출수후 40일간의 평균기온에 의한 적산온도 88$0^{\circ}C$의 출현기일은 수원에서 8월 23일이었고, 년간편차를 고려한 안전출수기일은 8월 19일로서 적산온도면에서는 관행 출수기일은 약간 늦다고 보았다. 9. 등열기의 평균기온에 의한 적산온도는 현행 수도작기로서는 최종한계시기에 놓여 있으며, 평균기온의 년간편차와 우리 나라의 최저기온이 낮은 점을 고려할 때, 현행출수기는 다소 늦은 것으로 보았다. 10. 생육단계별의 수도체내의 질소함량은 영양생장기의 질소함량이 과다하였으며, 출수 이후에 영양조락을 여하히 방지하느냐가 문제된다고 보았다. 11. 수리불안전답 및 천수답이 차지하는 전답면적의 비율은 차차 감소되고 있는데, 이와 전체 10a당 수량의 증가율과의 상관계수를 산출하였는데, 수리불안전답과의 상관계수 (4)는 +0.525였으며, 천수답과는 r=+0.832, 그리고 수리불안전답과 천수답을 합계한 것과의 상관계수 (r)는 +0.841로서 후2자와는 고도의 정(+) 상관을 보여 천수답이 차지하는 면적비율이 작을수록 단위수량을 증가하였다. 12. 비료삼요소시험(주산력시험)성적을 보면 무비료구의 10a당 현미수량은 우리 나라가 231kg인데, 일본의 그것은 360kg으로서 우리 나라보다 약 56%나 높았다. 즉 우리 나라의 지력은 일본에 비하여 매우 낮았다. 또 무질소구의 10a당 현미수량은 우리 나라가 236 kg인데 일본의 그것은 383 kg 으로서 우리 나라보다 62%나 높았다. 즉 우리 나라의 지력을 좌우하는 것은역시 질소라고 할 수 있다. 13. 우리 나라와 일본의 답토양의 화학적 성질을 비교해본즉 다음과 같았다. (1) 우리 나라 답토양은 유기물ㆍ전질소 및 치환성석회와 마그네슘의 함량이 일본의 그것보다 낮아 반정도에 불과하였고, (2) N/2 염산 가용규산함량은 평균치로 보아 우리나라 답토양이 적었고, 규산의 시용이 필요하다고 보았으며, (3) 염기치환용량이 일본의 반 정도이었다. 14. 우리 나라에 있어서 고위수량답과 저위수량답 토양의 성질을 비교하여 본즉 염기치환용량ㆍ치환성석회와 마그네슘ㆍ가리ㆍ인산ㆍ망간ㆍ규산 및 철 등의 성분이 저위수량답 토양에서 적었다. 15. 작통의 깊이는 항상 고위수량답에서 깊으며, 우리 나라 답토양의 작토는 일본의 그것에 비하여 얕다. 16. 전기한 바의 제조건을 종합 검토하고 비료삼요소이외에 규산과 미량요소로서 망간 및 철에 대하여 수도생리 및 형태형성 내지 수량에 미치는 영향을 고려하여 보다 합리적으로 사료되는 비료조건을 제시하였다.

  • PDF