• Title/Summary/Keyword: Total energy consumption

Search Result 998, Processing Time 0.022 seconds

The Effect of Folding Wing on Aerodynamics and Power Consumption of a Flapping Wing

  • Lee, Seunghee;Han, Cheolheui
    • International Journal of Aerospace System Engineering
    • /
    • v.3 no.2
    • /
    • pp.26-30
    • /
    • 2016
  • Experimental study on the unsteady aerodynamics analysis and power consumption of a folding wing is accomplished using a wind tunnel testing. A folding wing model is fabricated and actuated using servo motors. The flapping wing consists of an inboard main wing and an outboard folding wing. The aerodynamic forces and consumed powers of the flapping wing are measured by changing the flapping and folding wings inside a low-speed wind tunnel. In order to calculate the aerodynamic forces, the measured forces are modified using static test data. It was found that the effect of the folding wing on the flapping wing's total lift is small but the effect of the folding wing on the total thrust is larger than the main wing. The folding motion requires the extra use of the servo motor. Thus, the amount of the energy consumption increases when both the wings are actuated together. As the flight speed increases, the power consumption of the folding wing decreases which results in energy saving.

Sustainable energy action plans of medium-sized municipalities in north Greece

  • Lymperopoulos, Konstantinos A.;Botsaris, Pantelis N.;Angelakoglou, Komninos;Gaidajis, Georgios
    • Advances in Energy Research
    • /
    • v.3 no.1
    • /
    • pp.11-30
    • /
    • 2015
  • The covenant of Mayors initiative includes the commitment of the municipalities-signatories to reduce voluntarily the greenhouse gas emissions over 20--- by 2020 within their boundaries and obligates them to develop and submit an energy consumption analysis and a sustainable energy action plan within a year from the adhesion. The present paper discusses the energy profile of three medium-sized north-eastern Greek Municipalities (Kavala-MoK, Alexandroupolis-MoA, Drama-MoD) through the analysis of their municipal energy balance. The results of the total final energy consumption per capita include 14.10MWh/capita, 14.24MWh/capita and 12.91MWh/capita for MoK, MoA and MoD respectively. The analysis highlighted the increased energy consumption of the private sectors, namely residential and tertiary building sand private transport. The assessment of the municipalities' energy profiles along with examination of national regulations and action plans and investigation of best available practices within the Covenant of Mayors shaped the development of the sustainable energy action plans of the examined municipalities that is presented in this paper. The proposed pathway towards low-carbon municipalities can be considered a representative case study and a starting point for other municipalities with similar characteristics.

Anomaly Detection and Diagnostics (ADD) Based on Support Vector Data Description (SVDD) for Energy Consumption in Commercial Building (SVDD를 활용한 상업용 건물에너지 소비패턴의 이상현상 감지)

  • Chae, Young-Tae
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.579-590
    • /
    • 2018
  • Anomaly detection on building energy consumption has been regarded as an effective tool to reduce energy saving on building operation and maintenance. However, it requires energy model and FDD expert for quantitative model approach or large amount of training data for qualitative/history data approach. Both method needs additional time and labors. This study propose a machine learning and data science approach to define faulty conditions on hourly building energy consumption with reducing data amount and input requirement. It suggests an application of Support Vector Data Description (SVDD) method on training normal condition of hourly building energy consumption incorporated with hourly outdoor air temperature and time integer in a week, 168 data points and identifying hourly abnormal condition in the next day. The result shows the developed model has a better performance when the ${\nu}$ (probability of error in the training set) is 0.05 and ${\gamma}$ (radius of hyper plane) 0.2. The model accuracy to identify anomaly operation ranges from 70% (10% increase anomaly) to 95% (20% decrease anomaly) for daily total (24 hours) and from 80% (10% decrease anomaly) to 10%(15% increase anomaly) for occupied hours, respectively.

A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building (사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석)

  • Seo, Byeong-Mo;Yu, Byeong-Ho;Lee, Kwang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.

Energy Consumption Evaluation for Two-Level Cache with Non-Volatile Memory Targeting Mobile Processors

  • Matsuno, Shota;Togawa, Masashi;Yanagisawa, Masao;Kimura, Shinji;Sugibayashi, Tadahiko;Togawa, Nozomu
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.4
    • /
    • pp.226-239
    • /
    • 2013
  • A number of systems have several on-chip memories with cache memory being one of them. Conventional cache memory consists of SRAM but the ratio of static energy to the total energy of the memory architecture becomes larger as the leakage power of traditional SRAM increases. Spin-Torque Transfer RAM (STT-RAM), which is a variety of Non-Volatile Memory (NVM), has many advantages over SRAM, such as high density, low leakage power, and non-volatility, but it consumes too much writing energy. This study evaluated a wide range of energy consumptions of a two-level cache using NVM partially on a mobile processor. Through a number of experimental evaluations, it was confirmed that the use of NVM partially in the two-level cache effectively reduces energy consumption significantly.

  • PDF

A Study on the Major Contituent Components & the Effect of Efficiency Improvement for the BEMS (BEMS(Building Energy Management System) 구축을 위한 주요 구성요소와 건물에너지효율등급 개선효과에 관한 연구)

  • Son, Hag-Sig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.105-113
    • /
    • 2014
  • Currently, the energy consumption rate in buildings is approximately 28.5% of the total energy consumption in Korea. Therefore the amount of the consumption of petroleum resourses is at a worrying level of the blackout. The system of the amount of the Architectural Energy Efficiency Grade [AEEG] is in force by the government to apply the technologies of the Emissions Trading System and the Target Management System to mitigate the Green House Gases for buildings according to the climate change. On the account the mitigation of the Green House Gases and the reduction of the energy, from the view of maintenance and management, for the new and remodeling buildings should be under consideration. The author wants to present the possible ways how to improve the AEEG for the existing buildings by trying to establish the foundation of the BEMs, and by confirming the potential of the energy savings.

Decomposition Analysis of Energy Use for Water Supply: From the Water-Energy Nexus Perspective (물 공급을 위한 에너지 사용 요인분해 분석: Water-Energy Nexus 관점에서)

  • Yoo, Jae-Ho;Jo, Yeon Hee;Kim, Hana;Jeon, Eui Chan
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.5
    • /
    • pp.240-246
    • /
    • 2022
  • Water and energy are inextricably linked and referred to as 'Water-Energy Nexus'. Recently, this topic has been drawing a lot of attention from various studies due to the exacerbated water availability. Korea's water and energy consumption has been increasing consistently, which calls for better management. This paper aims to identify changes in electricity consumption in relation to water intake and purification processes. Using Log Mean Divisia Index (LMDI) Decomposition Analysis method, this study attributes the changes to major factors such as; Total population (population effect), household/population (structure effect), GDP/household (economic effect), and water-related energy use/GDP (unit effect). The population effect, structure effect, and economic effect contributed to an increase in water-related electricity consumption, while the unit effect contributed to a decrease. As of 2019, the economic effect increased the water supply sector's electricity consumption by 534 GWh, the population effect increased by 73 GWh, and the structure effect increased by 243 GWh. In contrast, the unit effect decreased the electricity consumption by -461 GWh. We would like to make the following suggestions based on the findings of this study; first, the unit effect must be improved by increasing the energy efficiency of water intake and purification plants and installing renewable energy power generation facilities. Second, the structure effect is expected to increase over time, and to mitigate it, water consumption must be reduced through water conservation policies and the improvement of water facilities. Finally, the findings of this study are expected to be used as foundational data for integrated water and energy management.

Development of control and monitoring board for building energy saving valve (빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발)

  • Oh, Jin-Seok;Kang, Young-Min;Jang, Jae-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.895-902
    • /
    • 2018
  • Energy consumption in buildings is close to 40% of the total national energy consumption in developed countries such as US and Japan, and Korea accounts for 24% of total energy consumption. In buildings, HVAC can't freely control the cooling flow rate according to the required calorie, so energy is not used efficiently. Therefore, by using the energy saving valve, the flow rate can be controlled by the required amount of heat and the energy can be saved. In this paper, we define basic conditions and develop control and monitoring boards for building energy saving valves based on PIC processor with low power and high cost-effectiveness. The designed board displays and transmits in real time information about two temperature values, flow values and calculated calories for temperature difference measurement. The developed board will be useful for real - time monitoring of the state of the valve in the future and development of the valve for the offshore.

Low-power Filter Cache Design Technique for Multicore Processors (멀티 코어 프로세서를 위한 저전력 필터 캐쉬 설계 기법)

  • Park, Young-Jin;Kim, Jong-Myon;Kim, Cheol-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.12
    • /
    • pp.9-16
    • /
    • 2009
  • Energy consumption as well as performance should be considered when designing up-to-date multicore processors. In this paper, we propose new design technique to reduce the energy consumption in the instruction cache for multicore processors by using modified filter cache. The filter cache has been recognized as one of the most energy-efficient design techniques for singlecore processors. The energy consumed in the instruction cache accounts for a significant portion of total processor energy consumption. Therefore, energy-aware instruction cache design techniques are essential to reduce the energy consumption in a multicore processor. The proposed technique reduces the energy consumption in the instruction cache for multicore processors by reducing the number of accesses to the level-1 instruction cache. We evaluate the proposed design using a simulation infrastructure based on SimpleScalar and CACTI. Simulation results show that the proposed architecture reduces the energy consumption in the instruction cache for multicore processors by up to 3.4% compared to the conventional filter cache architecture. Moreover, the proposed architecture shows better performance over the conventional filter cache architecture.

LMDI Decomposition Analysis for Electricity Consumption in Korean Manufacturing (LMDI 요인 분해분석을 이용한 우리나라 제조업 전력화 현상에 관한 연구)

  • Han, Joon
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.137-148
    • /
    • 2015
  • So far, the phenomenon of "electrification" has been deepened in Korean industry and especially direct heating energy which accounted for 44.0%(2010) of total energy consumed in Korean manufacturing has been significantly electrified. This paper decomposed electricity consumption for direct heating in Korean manufacturing from 1992 to 2012 using LMDI(Log Mean Divisia Index). This paper includes 4 different factors such as electricity proportion effect, direct heating proportion effect, energy intensity effect and added value effect. And this paper compared the consumption pattern by business type. As results, electricity proportion effect had contributed the most to the increase of electricity consumption for direct heating in Korean manufacturing. And Petrol-Chemical and Iron & Steel had the most electrification of direct heating.