• Title/Summary/Keyword: Total efficiency

Search Result 5,634, Processing Time 0.039 seconds

Fluid Dynamic Efficiency of an Anatomically Correct Total Cavopulmonary Connection: Flow Visualizations and Computational Fluid Dynamic Studies

  • Yun, S.H.;Kim, S.Y.;Kim, Y.H.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.2
    • /
    • pp.36-41
    • /
    • 2003
  • Both flow visualizations and computational fluid dynamics were performed to determine hemodynamics in a total cavopulmonary connection (TCPC) model for surgically correcting congenital heart defects. From magnetic resonance images, an anatomically correct glass model was fabricated to visualize steady flow. The total flow rates were 4, 6 and 8L/min and flow rates from SVC and IVC were 40:60. The flow split ratio between LPA and RPA was varied by 70:30, 60:40 and 50:50. A pressure-based finite-volume software was used to solve steady flow dynamics in TCPC models. Results showed that superior vena cava(SVC) and inferior vena cava(IVC) flow merged directly to the intra-atrial conduit, creating two large vortices. Significant swirl motions were observed in the intra-atrial conduit and pulmonary arteries. Flow collision or swirling flow resulted in energy loss in TCPC models. In addition, a large intra-atrial channel or a sharp bend in TCPC geometries could influence on energy losses. Energy conservation was efficient when flow rates in pulmonary branches were balanced. In order to increase energy efficiency in Fontan operations, it is necessary to remove a flow collision in the intra-atrial channel and a sharp bend in the pulmonary bifurcation.

  • PDF

Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year (평판형 태양열 집열기의 연중 열적 성능의 모델링 해석)

  • Kim, Gew Deok;Park, Bae Duck;Kim, Kyoung Hoon
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.

A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System (하이브리드 제습냉방시스템의 성능평가 연구)

  • Hwang, Won-Baek;Kim, Young-Chan;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

A Study of Non-point Source Reduction Efficiency by Constructed Wetland installed in Flood Pumping Station (빗물펌프장에 설치된 인공습지의 비점오염원 저감효율 연구)

  • Chun, Suk-Young;Kim, Ji-Tae;Lee, Il-Kook;Chang, Soon-Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • The aim of this study was evaluated the effects of total rainfall, rainfall intensity and antecedent dry days and identify the correlation analysis with the EMC removal efficiency, in order to provide an understanding of the operation and maintenance factors of constructed wetland in flood pumping station. This study was conducted total of 20 monitoring in a catchment(326.2 ha) of constructed wetland in Ga-un flood pumping station located at the downstream of the Wang-suk stream. The determined EMC removal efficiencies were $36.04{\pm}9.45%$ for BOD, $38.50{\pm}13.50%$ for $COD_{Mn}$, $34.34{\pm}13.05%$ for TN and $34.22{\pm}14.27%$ for TP, respectively. These results showed that the pollutants concentration and EMC were reduced while passing through the constructed wetland. In the correlation analysis, the highly correlations with EMC removal efficiency of BOD and $COD_{Mn}$ were observed for total rainfall and rainfall intensity (P<0.05). However, the correlations were not found with TN and TP for rainfall variables.

A COMPARATIVE ANALYSIS ON EFFICIENCY AND TOTAL FACTOR PRODUCTIVITY IN CONSTRUCTION FIRMS BETWEEN KOREA AND JAPAN

  • J.L. Park;S.S. Kim;D.J. Kwark;J.G. Park;J.H. Kim;J.J. Kim
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.315-320
    • /
    • 2013
  • The aim of this study is to compare efficiency and Total Factor Productivity(TFP) between Korean and Japanese construction firms in Korea and Japan over the period of 2005-2011. The results of this study are as follows. Efficiency scores of Korean construction firms are 0.797, and Japanese construction firms are 0.921. Second, annual total factor productivity growth of Korean construction firms is 0.5% and technical progress do much for TFP decrease. However Japanese construction firms marked annual increasing of 2.5% of TFP. Third, technical progress contributed in TFP increase of construction firms in Korea. Korean construction firms, however, relatively lagged behind Japanese construction firms in technical progress. Therefore, Korean construction firms need strategies to achieve technical advances including adopting new technology or process innovation to maintain competitiveness, survive, and develop in the future competition with Japan.

  • PDF

Research on Efficiency of Western China's Universities under the "Double First-Class" Initiative ("더블 퍼스트 클래스"를 통한 중국 서부 대학의 연구 효율성에 관한 연구)

  • Youming Li;Jae-Yeon Sim
    • Industry Promotion Research
    • /
    • v.8 no.4
    • /
    • pp.257-266
    • /
    • 2023
  • The research focuses on the provincial universities in the western region of China and investigates the research level of 12 provincial universities from 2017 to 2021, considering both static efficiency and dynamic efficiency. The static efficiency is examined using Data Envelopment Analysis (DEA), while the dynamic efficiency is analyzed using the Malmquist model. The analysis results are as follows: the scientific research efficiency of universities in the 12 western provinces is generally not high. Against the background of the "Double First-Class" construction, the overall efficiency of scientific research in universities is showing an increasing trend. The main reason for the increase in scientific research efficiency is the increase in scale efficiency in recent years. The total factor productivity (TFP) of research activities is influenced by the technology progress index and exhibits a pattern of initial increase, followed by a decline, and then an increase again. Research conclusion: Western colleges and universities should reasonably allocate resources for scientific research activities, perfect scientific research mechanisms, improve management standards, promote scientific innovation and corresponding achievements, and ultimately raise the scientific and technological level in western China.

A Study on Removal Efficiency and Applicability of Natural Type Road Non-point Pollutant Reduction Facilities (자연형 도로 비점오염저감시설의 저감효율 및 적용성 연구)

  • Lee, Sang Hyuk;Cho, Hye Jin;Kim, Lee Hyung
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.9-17
    • /
    • 2014
  • PURPOSES : The purpose of this study is to assess removal efficiency of non-point pollutants and applicability for non-point pollutant reduction facilities by conducting the demonstration project operation. METHODS : In order to analyze removal efficiency of non-point pollutants for facilities such as a grassed swale, a small constructed wetland, a free water surface wetland, a horizontal sub-surface flow wetland, and a sand filtration, the field data including specifications of facilities, rainfall, inflow and runoff rainfall effluent etc. was acquired after occurring rainfall events, and the acquired data was analyzed for removal efficiency rate to assess road non-point pollutants facilities using event mean concentration (EMC) and summation of load (SOL) methods. RESULTS : The results of analyzing rainfall effluent, non-point pollutant sources showed that total suspended solid (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total nitrogen (TN), total phosphorus (TP), chrome (Cr), zinc (Zn), and lead (Pb) can be removed through non-point pollutant reduction facilities by 60.3% ~ 100%. Especially removal efficiency of TSS, COD and BOD is relatively higher than removal efficiency of other non-point pollutant sources in all kind of non-point pollutant facilities. CONCLUSIONS : Based on the result of this study, even though natural type of non-point pollutant reduction facilities for roads occupy small areas comparing with drainage basin areas, most of non-point pollutant sources would be removed through the facilities.

Analysis of profitability and its affecting factors in restaurant franchise firms (외식 프랜차이즈 기업의 수익성과 영향 요인 분석)

  • Park, Hyun-Jeong;Shin, Seo-Young;Yang, Il-Sun;Choi, Kyu-Wan
    • Korean journal of food and cookery science
    • /
    • v.23 no.2 s.98
    • /
    • pp.270-279
    • /
    • 2007
  • The purposes of this study were to analyze the profitability of audited restaurant franchise firms and to investigate the financial variables affecting profitability. This study decomposed profit variation into the three main factors comprising the Du Pont Identity (operating efficiency, asset use efficiency and financial leverage). The operating efficiency of restaurant franchise firms was on the rise until 2004, but dropped dramatically in 2005. Especially, the profit margin dropped from 13.46% in 2004 to 6.54% in 2005. The asset use efficiency has been decreasing since 2003. The total asset turnover ratio, which can be indicative of over-investment, dropped from 1.55 in 2003 to 1.50 in 2005. The financial leverage remained stable after 2002. There were major differences in debt accumulation among the firms, and the current level of debt was thought to be higher in the restaurant industry than in other industries. Based on the results of a multiple regression analysis, we concluded that the factors affecting ROE were the debt-equity ratio, total asset turnover and the size of the firm. The debt-equity ratio and total asset turnover had a significantly positive effect on ROE, while the firm size had a significantly negative effect on ROE. However, the current ratio and sales growth rate were not significant. The finding that firm size and profitability were negatively related implied that restaurant franchise firms should pursue qualitative growth rather than quantitative growth. There was no major difference in profitability between domestic brands and foreign brands. However, the domestic brand was more efficient in terms of asset usage than the foreign brand.

Regional Total Factor Energy Efficiency and its Determinants of the Korean Manufacturing Sector (우리나라 16개 시·도의 제조업부문 총요소 에너지 효율성 및 결정요인 분석)

  • Park, Changsuh;Seo, Yun Seok
    • Journal of the Korean Regional Science Association
    • /
    • v.33 no.1
    • /
    • pp.3-16
    • /
    • 2017
  • This paper analyzed 16 regional total factor energy efficiency (TFEE) of the Korean manufacturing sector using data envelopment analysis method for the period of 2005-2013. According to the empirical results, it is necessary to use TFEE as well as partial energy efficiency defined by the ratio of energy usage to output (energy intensity) when we compare energy efficiency. Secondly, TFEE in the Korean manufacturing sector is quite different across 16 regions. For example, Gangwon province should improve energy efficiency by 55% compared to Seoul, Gwangju, Ulsan, and Gyeongbuk which are located on production frontier. Furthermore, the estimation of panel tobit regression model showed that the higher non fossil fuel using, the higher production share of large-sized firms, the lower energy intensity, and the lower capital-labor ratio could have positive effect on TFEE.

Application of polymer coagulants and optimization of operational parameters to improve total phosphorus removal efficiency in wastewater treatment plants (하수처리장 총인 제거율 개선을 위한 고분자 응집제 적용 및 최적 운전인자 도출)

  • Gyu-won Kim;Yun-Seong Choi;Seung-Hwan Lee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.4
    • /
    • pp.233-242
    • /
    • 2024
  • This study evaluates the potential of various coagulants to enhance the efficiency of total phosphorus removal facilities in a sewage treatment plant. After analyzing the existing water quality conditions of the sewage treatment plant, the coagulant of poly aluminium chloride was experimentally applied to measure its effectiveness. In this process, the use of poly aluminium chloride and polymers in various ratios was explored to identify the optimal combination of coagulants. The experimental results showed that the a coagulants combination demonstrated higher treatment efficiency compared to exclusive use of large amounts of poly aluminium chloride methods. Particularly, the appropriate combination of poly aluminium chloride and polymers played a significant role. The optimal coagulant combination derived from the experiments was applied in a micro flotation method of real sewage treatment plant to evaluate its effectiveness. This study presents a new methodology that can contribute to enhancing the efficiency of sewage treatment processes and reducing environmental pollution. This research is expected to make an important contribution to improving to phosphorus remove efficiency of similar wastewater treatment plant and reducing the ecological impact from using coagulants in the future.