• 제목/요약/키워드: Total effective temperature

검색결과 526건 처리시간 0.027초

초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가 (Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building)

  • 류택형;엄정섭
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

RTP 와 PECVD을 이용한 저가의 표면 passivation 막들의 특성연구 (Cost-effective surface passication layers by RTP and PECVD)

  • 이지연;이수홍
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.142-145
    • /
    • 2004
  • In this work, we have investigated the application of rapid thermal processing (RTP) and plasma enhanced chemical vapour deposition (PECVD) for surface passivation. Rapid thermal oxidation (RTO) has sufficiently low surface recombination velocities (SRV) $S_{eff}$ in spite of a thin oxides and short process time. The effective lifetime is increasing with an increase of the oxide thickness. In the same oxide thickness, The effective lifetime is independent on the process temperature and time. $S_{eff,max}$ is exponentially decreased with increasing oxide thickness. $S_{eff,max}$ can be reduced to 200 cm/s with only 10 nm oxide thickness. On the other hand, three different types of SiN are reviewed. SiN1 layer has a thickness of about 72 nm and a refractive index of 2.8. Also, The SiN1 has a high passivation quality. The effective lifetime and SRV of 1 $\Omega$ cm Float zone (FZ) silicon deposited with SiN1 is about 800 s and under 10 cm/s, respectively. The SiN2 is optimized for the use as an antireflection layer since a refractive index of 2.3. The SiN3 is almost amorphous silicon caused by less contents of N2 from total process. The effective lifetime on the FZ 1 ${\Omega}cm$ is over 1000 ${\mu}s$.

  • PDF

심부 광산의 효율적 환기 시스템에 관한 연구 (A Study of Efficient Ventilation System in Deep Mines)

  • 송두환;김윤광;김택수;김상환
    • 청정기술
    • /
    • 제22권3호
    • /
    • pp.168-174
    • /
    • 2016
  • 석탄 광산의 심부화 및 운행갱도의 증가로 인한 온도상승으로 작업환경이 점차 악화되는 광산에서 작업환경의 개선을 위하여 A광업소를 대상으로 통기평가를 하였으며 갱내의 통기 효율을 증가시키기 위하여 작업장의 온도 저하를 위한 선풍기 통기 방식에 대해 유동해석 프로그램을 이용하여 통기방식에 따른 운반갱도의 온도분포를 해석하였다. 연구결과 A 광업소의 소요환기량은 17,831 m3 min-1으로 산출되었으며, 실제 총 입기량은 16,474 m3 min-1로 환기량이 1,357 m3 min-1 부족한 것으로 나타났고 운반갱도에서 작업장까지의 온도는 송기식 통기보다 배기식 통기방식이 2~3℃ 낮게 분포하였다. 운반갱도에서 작업장까지의 길이가 긴 경우 송기식 보다는 배기식 통기방식을 운용 하는 것이 더욱 효과적일 것이다.

Accuracy evaluation of near-surface air temperature from ERA-Interim reanalysis and satellite-based data according to elevation

  • Ryu, Jae-Hyun;Han, Kyung-Soo;Park, Eun-Bin
    • 대한원격탐사학회지
    • /
    • 제29권6호
    • /
    • pp.595-600
    • /
    • 2013
  • In order to spatially interpolate the near-surface temperature (Ta) values, satellite and reanalysis methods were used from previous studies. Accuracy of reanalysis Ta was generally better than that of satellite-based Ta, but spatial resolution of reanalysis Ta was large to use at local scale studies. Our purpose is to evaluate accuracy of reanalysis Ta and satellite-based Ta according to elevation from April 2011 to March 2012 in Northeast Asia that includes various topographic features. In this study, we used reanalysis data that is ERA-Interim produced by European Centre for Medium-Range Weather Forecasts (ECMWF), and estimated satellite-based Ta using Digital Elevation Meter (DEM), Normalized Difference Vegetation Index (NDVI), difference between brightness temperature of $11{\mu}m$ and $12{\mu}m$, and Land Surface Temperature (LST) data. The DEM data was used as auxiliary data, and observed Ta at 470 meteorological stations was used in order to evaluate accuracy. We confirmed that the accuracy of satellite-based Ta was less accurate than that of ERA-Interim Ta for total data. Results of analyzing according to elevation that was divided nine cases, ERA-Interim Ta showed higher accurate than satellite-based Ta at the low elevation (less than 500 m). However, satellite-based Ta was more accurate than ERA-Interim Ta at the higher elevation from 500 to 3500 m. Also, the width of the upper and lower quartile appeared largely from 2500 to 3500 m. It is clear from these results that ERA-Interim Ta do not consider elevation because of large spatial resolution. Therefore, satellite-based Ta was more effective than ERA-Interim Ta in the regions that is range from 500 m to 3500 m, and satellite-based Ta was recommended at a region of above 2500 m.

NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정 (Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra)

  • 이모성
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.143-151
    • /
    • 1997
  • NaI(TI) 검출기의 파고는 용도에 따라 변하기 때문에, 온도 변화는 분광분석기의 에너지 교정에 영향을 미친다. 외부 선원을 사용하여 파고의 온도 의존성을 보상할 수 있으나 이것은 바람직하지 않은 콤프턴 영향을 야기한다. 이 연구에서는 환경중의 감마선 스펙트럼에서 뚜렸한 $^{212}Pb$로부터의 239 keV 피크, $^{214}Pb$로부터의 351 keV 피크, 40K로부터의 1460 keV 피크, $^{208}Tl$으로 부터의 2614 keV 피크를 에너지 교정의 기준 피크로 사용하였다. 이들 피크를 이용하는 방법은 마이크로소프트사의 Visual Basic으로 프로그램화하였다. 이렇게 개발된 프로그램은 신뢰성과 적용성을 검증하기 위해 $-20^{\circ}C$ 부터 $10^{\circ}C$까지 변하는 온도에서 30분 간격으로 측정한 환경 스펙트럼에 적용하였다. 그 결과로써 일상의 기온에서 측정한 $3'{\times}3'$ NaI(Tl) 검출기의 스펙트럼에 대해 이 방식의 에너지 교정은 효과적임이 입증되었다.

  • PDF

촉진양생이 콘크리트의 28일 압축강도에 미치는 영향에 관한 연구 (A Study on the Effect of Accelerated Curing on 28-Days Compressive Strength of Concrete)

  • 최세규;유승룡;김생빈
    • 콘크리트학회지
    • /
    • 제8권4호
    • /
    • pp.141-148
    • /
    • 1996
  • 기존의 촉진양생 연구는 1960~1970년대에 주로 실행된 것으로, 전체 증기양생기간이 18시간 또는 24시간인 경우에 대하여 연구되었고, 상기 연구 결과는 수동식 항온항습조를 사용하였으므로 온도상승구배의 효과에 대하여 명확한 규명을 할 수 없다고 판단되었다. 따라서 국내 PC공장 여건에서 그 직접적인 적용이 불가능한 실정이다. 본 연구는 효과적인 콘크리트 촉진양생에 대한 기본 자료를 정립할 목적으로, 국내 PC 공장에서 사용하는 배합표를 근거로 시험공시체를 제작한 후, 각 해당 양생주기 조건을 변화시켜 가면서 실험하였다. 탈형시 및 수중양생 재령28일의 측정하고 비교 검토한 결과, 재령 28일 후 설계강도값을 초과하는 가장 효과적인 촉진양생조건, 본 실험조건 하에서 전양생시간은 커다란 영향을 미치지 않았으며, 온도상승구배는 $30^{circ}C/hr$ 이하로, 최고양생온도는 $82^{\circ}C$이하로 양생해야 하며, 또한 촉진양생 후 2차 양생으로 강도증진을 도모함이 촉진양생의 효과를 증대시킬 수 있다고 판단되었다.

부영양 신갈지에서 천연물질 혼합제(PMC)의 수질개선능: 현장수온의 영향 (Effect of Temperature on Water Quality Improvement of Natural Plant-Mineral Composites (PMC) in a Eutrophic Lake, Lake Shingal, Korea)

  • 변정환;황수옥;문선기;황순진;김백호
    • 생태와환경
    • /
    • 제46권2호
    • /
    • pp.225-233
    • /
    • 2013
  • 부영양호 신갈지의 수질개선을 위하여 이미 개발된 천연물질 혼합제(PMC)의 수질개선능(WQI)에 수온변화가 어떠한 영향을 미치는지 현장실험을 실시하였다. 실험결과 식물플랑크톤, BOD, 총인 등은 $20^{\circ}C$ 이하에서는 70% WQI 이상을 보였으나 $25^{\circ}C$ 이상에서는 40% WQI 이하로 오히려 감소하였다. 한편 수온의 증가에 따라 남조류에 대해서는 WQI는 감소하였고, 규조류는 수온변화에 상관없이 90% 이상 높은 WQI를 나타냈으며, 박테리아와 총 질소는 수온과 상관없이 매우 낮은 WQI를 보였다. 이상의 결과들은 PMC의 수질개선능이 수온과 밀접한 관계를 가지며, $25^{\circ}C$ 이상의 고온기에 Microcystis aeruginosa가 우점하는 남조대발생보다 겨울철 저온기에 우점하는 규조류에 더 효과적일 것으로 판단되었다.

반응표면분석법을 이용한 오가피의 열수 추출조건 최적화 (Optimizing the Hot-water Extraction Conditions for Acanthopanacis cortex Using Response Surface Methodology)

  • 김인호;김성호;권중호
    • 한국식품영양과학회지
    • /
    • 제37권4호
    • /
    • pp.512-520
    • /
    • 2008
  • 오가피(Acanthopanacis cortex)의 유효성분 및 항산화적 특성을 조사하기 위하여 반응표면분석법에 의하여 열수추출 특성을 모니터링 하여 최적추출조건을 설정하였다. 총 추출수율의 최적조건은 추출온도 $84.28^{\circ}C$, 추출시간 3.59 hr 및 시료에 대한 용매비 18.37 mL/g이었고, 유효성분 eleutheroside E에 대한 최적조건은 $81.16^{\circ}C$, 3.56 hr, 19.06 mL/g, 총 페놀성 화합물에 대한 최적조건은 $88.45^{\circ}C$, 4.33 hr, 21.12 mL/g 등으로 각각 나타났다. 각 변수에 대한 회귀식을 도출하여 공정 인자별 오가피의 총 추출수율, 유효성분 eleutheroside E와 chlorogenic acid 함량 및 항산화적 특성에 대한 최적추출조건을 superimposing한 결과, 추출온도 $81{\sim}88^{\circ}C$, 추출시간 $3.5{\sim}4.3hr$ 및 시료에 대한 용매비 $18{\sim}21mL/g$의 범위로 각각 예측되었다. 오가피의 유효성분과 항산화적 특성에 대한 열수추출조건의 예측값은 실제값과 유사하였다.

반응표면분석을 이용한 홍삼주 발효조건 최적화 (Optimization of Fermentation Condition for Red Ginseng Wine Using Response Surface Methodology.)

  • 김성호;강복희;노상균;김종국;이상한;이진만
    • 생명과학회지
    • /
    • 제18권4호
    • /
    • pp.556-564
    • /
    • 2008
  • 인삼의 다양한 식품소재개발을 위하여 반응표면분석법을 이용한 홍삼주의 최적발효조건을 모니터링하였다. 중심합성 계획법에 의하여 독립변수로서 발효온도, 발효기간 및 초기 pH를 설정하여 종속변수 홍삼주의 이화학적 특성과 유효성분에 대한 영향을 조사하였다. 홍삼주의 알코올 함량과 총당 함량은 발효온도와 발효기간에 영향을 많이 받고 있는 것으로 나타났으며, 조사포닌 함량은 발효기간에 많은 영향을 받고 있는 것으로 나타났다. 발효 후의 pH는 초기 pH에 많은 영향을 받고 있는 것으로 나타났다. 홍삼주의 유효성분인 Ginsenoside 함량을 조사한 결과 주로 발효온도보다는 발효기간 및 초기 pH에 의해 영향을 받고 있는 것으로 조사되었으며, 발효기간이 길고 초기 pH가 높을수록 함량이 증가하는 것으로 나타났다. 홍삼주의 이화학적 특성과 유효성분 함량에 대하여 superimposed counter map으로 최적 조건을 예측한 결과 발효온도 $21{\sim}27^{\circ}C$, 발효기간은 $15{\sim}20$일, 초기 pH의 경우 $4.6{\sim}5.2$로 각각 예측되었다.

건조방법에 따른 작약근 건조 소요일수 및 성분 변화 (Changes in Days to Drying and Some Chemical Components by Different Drying Methods in Paeoniae radix)

  • 강광희;정명근
    • 한국작물학회지
    • /
    • 제41권3호
    • /
    • pp.362-369
    • /
    • 1996
  • 3년생 의성작약품종(faeornia lacrifora Pall.)을 1994년 2월에 수확하여 유피 및 거피상태로 처리한 후 상온음건법, 화력건조법, 증건법 및 냉동건조법으로 건조방법을 각각 달리하여 주 약용성분인 paeoniflorin함량 및 일반 화학성분을 조사한 결과는 다음과 같다. 1. 건물비율 50%까지의 건조일수는 거피상태 3$0^{\circ}C$ 화력건조가 동일온도의 유피상태보다 5일이 짧으며, 거피상태에서는 5$0^{\circ}C$ 화력건조법이 1.5일로 가장 빨랐고, 121$^{\circ}C$ 증건법은 8일로 가장 늦었다. 2. 상온음건 및 화력건조법의 경우 paeoniflorin 함량은 거피상태가 더 높았고, 반대로 증건법은 유피상태가 더 높았다. 화력건조법의 경우 건조온도가 높아짐에 따라 paeoniflorin 함량은 감소하였다. 3. 건조방법 중 3$0^{\circ}C$화력건조가 Paeoniflorin함량이 4.0%로 가장 높고, 건조일수가 단축되며, 색택 이 양호한 가장 적절한 건조법 이었다. 4. 화력건조시 건조온도가 높아짐에 따라 총당의 함량은 감소하고 전분은 증가하는 경향을 보였으며, 또 전분함량은 121$^{\circ}C$의 증건법을 제외한 모든 건조방법에서 거피상태보다 유피상태가 더 높았다. 5. 조단백질, 조섬유 및 조회분의 함량은 유피, 거피 및 건조방법에 따라 큰 차이가 없었다. 6. Paeoniflorin과 총당의 관계는 유피상태에서 정의 유의상관이, 그리고 paeoniflorin과 전분의 관계는 거피상태에서 부의 유의상관이 있었다.

  • PDF