• 제목/요약/키워드: Total dental rehabilitation

검색결과 117건 처리시간 0.03초

Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

  • Aroso, Carlos;Silva, Antonio Sergio;Ustrell, Raul;Mendes, Jose Manuel;Braga, Ana Cristina;Berastegui, Esther;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.21-29
    • /
    • 2016
  • This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: $Clix^{(R)}$, Dalbo-$Plus^{(R)}$ and $Locator^{(R)}$. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and $37^{\circ}C$. The abutments were placed at angulations of $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation ($F_{(2.48)}=343619$, P<.05) and the type of attachment ($F_{(7.48)}=23.220$, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석 (Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy)

  • 최민호;이일권;김유리;조혜원
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

유지 관리를 고려한 상악 총의치와 하악 All-on-4 임플란트 보철 수복 증례 (Maxillary complete denture and mandibular All-on-4 implant restoration considering maintenance: a case report)

  • 김소연;권은영;정경화;전혜미;강은숙;윤미정
    • 구강회복응용과학지
    • /
    • 제35권1호
    • /
    • pp.37-45
    • /
    • 2019
  • 무치악 환자의 보철치료에서 총의치를 이용한 보철 치료 시 각화 점막을 통해 교합력을 분담하므로 저작력과 저작 능률이 떨어지고 특히 지지 점막 면적이 작은 하악의 경우 상악에 비해 통증 발생 등의 부작용이 더 많다. 치조골 흡수가 많은 환자일수록 이는 더 심화되나 하악 구치부 측의 하치조신경관의 존재 때문에 임플란트를 동반한 적극적 치료가 어려운 경우가 많다. 이에 본 증례에서는 상악에는 전통적인 총의치를 제작하고 하악은 치조골 높이가 충분한 전방부에만 임플란트를 식립하여 all-on-4 방법으로 치료한 환자에서 좋은 경과를 보여 보고하고자 한다.

Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation

  • Hassan, Bassam;Greven, Marcus;Wismeijer, Daniel
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.381-386
    • /
    • 2017
  • PURPOSE. To integrate extra-oral facial scanning information with CAD/CAM complete dentures to immediately rehabilitate terminal dentition. MATERIALS AND METHODS. Ten patients with terminal dentition scheduled for total extraction and immediate denture placement were recruited for this study. The patients were submitted to a facial scanning procedure using the in-office PritiMirror scanner with bite registration records in-situ. Definitive stone cast models and bite records were subsequently submitted to a lab scanning procedure using the lab scanner (iSeries DWOS; Dental Wings). The scanned models were used to create a virtual teeth setup of a complete denture. Using the intra-oral bite records as a reference, the virtual setup was incorporated in the facial scan thereby facilitating a virtual clinical evaluation (teeth try-in) phase. After applying necessary adjustments, the virtual setup was submitted to a CAM procedure where a 5-axis industrial milling machine (M7 CNC; Darton AG General) was used to fabricate a full-milled PMMA immediate provisional prosthesis. RESULTS. Total extractions were performed, the dentures were immediately inserted, and subjective clinical fit was evaluated. The immediate provisional prostheses were inserted and clinical fit, occlusion/articulation, and esthetics were subjectively assessed; the results were deemed satisfactory. All provisional prostheses remained three months in function with no notable technical complications. CONCLUSION. Ten patients with terminal dentition were treated using a complete digital approach to fabricate complete dentures using CAD/CAM technology. The proposed technique has the potential to accelerate the rehabilitation procedure starting from immediate denture to final implant-supported prosthesis leading to more predictable functional and aesthetics outcomes.

치과 기공실의 조명에 관한 실태 조사 연구 (A study of illumination of dental laboratories)

  • 이효정;최종인;김성숙;동진근
    • 구강회복응용과학지
    • /
    • 제30권4호
    • /
    • pp.289-298
    • /
    • 2014
  • 목적: 본 연구는 치과 기공실의 조명이 심미 보철을 위한 색조의 분별과 조화, 재현에 적당한지 알아보기 위한 실태 조사이다. 연구 재료 및 방법: 48곳의 치과 기공실을 대상으로 lux meter와 color meter를 이용하여 포세린 작업대(porcelain table) 상판 중심의 조도와 색온도를 측정 하였다. 각각의 기공실을 자연광(day light)과 인공조명(artificial illumination)이 있는 오후 12시 - 2시 사이와 인공조명 만이 있는 오후 7시 - 10시 사이, 2차례 측정하였고, 맑은 날과 흐린 날로 구분하였다. 결과: 1. 전체 기공실의 평균 조도는 1871 lx이었고, 67%의 기공실이 1600 lx를 넘겨 색과 관련한 작업을 하기에 적합한 조도를 갖추었으나 33%의 기공실은 이에 미치지 못하였다. 2. 전체 기공실의 평균 색온도는 6506 K로 색과 관련한 작업을 하기에 부적절하였다. 적정 색온도인 5000 - 5500 K를 만족하는 기공실은 없었다. 3. 전체 기공실의 낮과 밤의 조도(P = 0.73) 및 맑은 날과 흐린 날의 조도(P = 0.89)와 낮과 밤의 색온도(P = 0.17) 및 맑은 날과 흐린 날의 색온도(P = 0.51)는 유의한 차이를 보이지 않았다. 결론: 본 연구에서 조사된 치과 기공실의 조명은 색과 관련한 작업을 하기에 부적절한 경우가 많았다.

성견에서 즉시 부하 후 임프란트 안정성 평가 : 임상적, 방사선학적 연구 (ASSESSMENT OF IMPLANT STABILITY AFTER IMMEDIATE LOADING IN DOGS : CLINICAL AND RADIOGRAPHIC STUDY)

  • 이주영;김수관;김상호;김완배
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권2호
    • /
    • pp.131-139
    • /
    • 2005
  • The therapeutic goal of implant dentistry is not merely tooth replacement but total oral rehabilitation. Considering dental implants as a treatment option can be provided patients with positive, long-term results. Implant dentistry has gone through many phases over the years. Modern technology and design allows us to predictably place our dental implants often load the implants at the time of placement. The purpose of this study is to evaluate the implant stability after immediate loading in dogs. The control group was performed delay loading and experimental group was immediate loading. Each group was measured periotest value(PTV) to evaluate clinical mobility and performed radiographic examination to evaluate marginal bone loss. Statistically significant difference was not founded in control group between experimental group in PTV(P>0.05) and marginal bone loss(P>0.05). Finally, implant stability after immediate loading was similar to delay loading implant.

20대 대학생들의 상악중절치 색조와 구강보건 및 식습관 관련 특성 (Oral health and eating habits characteristics relating to maxillary central incisor color of the university students in their twenties)

  • 이지영;윤영숙
    • 한국치위생학회지
    • /
    • 제12권2호
    • /
    • pp.261-273
    • /
    • 2012
  • Objectives : This study aims to prepare the basic data of the teeth color by measuring tooth mode using the color of the maxillary central incisor of the college students in their twenties as the dental colorimeter, and oral health and eating habit characteristics were examined. Methods : The maxillary central incisor(1 teeth) of the subjects of study as 467 students(male 89, female 378) was measured during the period from November 14, December 2 2011, so the color of total 467 teeth were examined, and oral health and eating habit characteristics were researched. Results : 1. As the results of measurement of the shade, value, hue of maxillary central incisor by the general characteristics of the subject, the major(shipbuilding information, special rehabilitation for young children) was higher at 3.3 of the shade, and the grade(1), age($$\geq_-20$$), major(beauty culture & cosmetic, occupational therapy) showed higher at +2 of the value, and the grade(1) and all major showed higher at R3 of the hue. 2. As the results of measurement of the shade, value, hue of maxillary central incisor by the oral health characteristics, the subjective teeth color(yellow) and the education of oral health(no) showed higher at 2.5 of the shade. 3. As the results of measurement of the shade, value, hue of maxillary central incisor by the eating habit characteristics of the subjects, the chocolate showed higher at 3.0 and 2.0 of the shade, and the red pepper paste showed higher at +2 and STD of the value, and the green tea showed higher at $R_3$ of the hue. Conclusions : This study demonstrates that the color of the maxillary central incisor showed differences various tendency according to the oral health and eating habit characteristics.

Long-term implant success at the Academy for Oral Implantology: 8-year follow-up and risk factor analysis

  • Busenlechner, Dieter;Furhauser, Rudolf;Haas, Robert;Watzek, Georg;Mailath, Georg;Pommer, Bernhard
    • Journal of Periodontal and Implant Science
    • /
    • 제44권3호
    • /
    • pp.102-108
    • /
    • 2014
  • Purpose: Rehabilitation of the incomplete dentition by means of osseointegrated dental implants represents a highly predictable and widespread therapy; however, little is known about potential risk factors that may impair long-term implant success. Methods: From 2004 to 2012, a total of 13,147 implants were placed in 4,316 patients at the Academy for Oral Implantology in Vienna. The survival rates after 8 years of follow-up were computed using the Kaplan-Meier method, and the impact of patient- and implant-related risk factors was assessed. Results: Overall implant survival was 97% and was not associated with implant length (P=0.930), implant diameter (P=0.704), jaw location (P=0.545), implant position (P=0.450), local bone quality (P=0.398), previous bone augmentation surgery (P=0.617), or patient-related factors including osteoporosis (P=0.661), age (P=0.575), or diabetes mellitus (P=0.928). However, smoking increased the risk of implant failure by 3 folds (P<0.001) and a positive history of periodontal disease doubled the failure risk (P=0.001). Conclusions: Summing up the long-term results of well over 10,000 implants at the Academy for Oral Implantology in Vienna it can be concluded that there is only a limited number of patients that do not qualify for implant therapy and may thus not benefit from improved quality of life associated with fixed implant-retained prostheses.

치과 보철물 거래 플랫폼 서비스의 중요성과 요구사항: 치과 전문가 설문조사 (Importance and requirements for dental prosthesis order platform services: a survey of dental professionals)

  • 김규리;손큰바다;이두형;김소연;진명욱;이규복
    • 구강회복응용과학지
    • /
    • 제39권3호
    • /
    • pp.105-118
    • /
    • 2023
  • 목적: 본 연구는 치과 보철물 거래 플랫폼 서비스의 중요성을 이해하고, 보다 넓은 적용을 위해 필수 요소를 파악하는 것을 목표로 하였다. 연구 재료 및 방법: 치과 의사, 치과 기공사, 치과 위생사, 그리고 치과 산업 종사자들을 대상으로 치과 보철물 주문 및 관련 플랫폼 서비스에 대한 견해를 평가하기 위해 설문 조사를 실시하였다(총 53명). 이를 위해 설문지는 치과 전문가의 검토를 거쳐 작성되었고, Cronbach's alpha coefficient를 사용하여 설문지의 신뢰도를 평가하였다. 요인 분석을 통해 총 변동의 88.417%를 설명하는 5개 범주의 57개 요인을 도출했다. 설문 조사는 온라인 설문지 플랫폼을 통해 실시되었으며, 데이터 분석은 통계 소프트웨어를 사용하여 one-way analysis of variance과 Tukey's honestly significant difference test을 사용하여 수행되었다(α = 0.05). 결과: 주문 시에 정확한 정보 입력, 효과적인 의사소통, 변형 없는 치과 인상체 전달, 데이터 전송 및 저장의 편리성, 안정적이고 합리적인 가격의 플랫폼 서비스 제공이 필수 요소로 확인되었다(P < 0.05). 또한, 이러한 항목의 중요성에는 연령, 치과 직업, 경력 경험에 따른 유의한 차이가 관찰되었다(P < 0.05). 결론: 치과 보철물 주문 플랫폼 서비스에 대한 치과 종사자들의 요구사항은 안정성과 경제성, 그리고 치과 보철물 데이터 전송 및 저장의 용이성이었다. 이러한 결과는 앞으로 치과 보철물 주문 및 관련 플랫폼 서비스의 개발 및 개선을 위한 중요한 지표가 될 수 있다.

금속 도재 하부구조물 제작 시 침적법의 타당도 실험 (Validity experiment of dipping method in the manufacture of metal-ceramic substructure)

  • 이완선;임수현;김욱태
    • 구강회복응용과학지
    • /
    • 제31권1호
    • /
    • pp.26-32
    • /
    • 2015
  • 목적: 본 연구는 상악 중절치(#11) 금속 도재 하부구조물(metal-ceramic substructure) 제작 시 반복첨가법(addition method)과 침적법(dipping method)의 차이점을 비교 분석하여 작업의 효율성의 차이를 평가하여 침적법의 활용 방안을 제시하는 것이 주요 목적이다. 연구 재료 및 방법: 주 모형과 경석고 복제모형을 제작하여 반복첨가법과 침적법으로 코핑을 각 10개씩 20개를 제작하여 실험하였다. 코핑은 경석고 지대치 모형에 고정시키고 에폭시 마운팅 컵(epoxy mounting cup)에 매몰하였다. 시편은 경화 후 절단기를 사용하여 순,설방향으로 절단하여 사포 후 디지털 현미경을 이용하여 4지점을 측정하였다. 결과: t-test를 이용하여 제작된 지대치 substructure의 측정값 평균을 비교한 결과는 전반적으로 유의한 차이가 나타나고 있다(P < 0.05). 결론: 본 연구의 결과는 금속 도재 하부구조물 제작 시 반복첨가법과 침적법의 유의적 차이가 없으므로 활용 방안으로써 제시 될 수 있다.