• 제목/요약/키워드: Total coliforms

검색결과 389건 처리시간 0.026초

낙동강 원수에 대한 대장균군 막여과시험법에 있어서 여러 인자가 결과에 미치는 영향 (The Influence of Various Factors upon the Membrane Filter Technique on Raw Water of the Nak-Dong River)

  • 현재열;윤종호;신상희;김종우
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.205-211
    • /
    • 2009
  • In this study, the membrane filter method was compared to the MPN method for the analysis of total coliforms from raw water using raw test waters and controls including 6 standard strains of coliforms, and the various factors were analyzed on the detection of general and fecal origin coliforms. The range of error rate for the detection of 5 standard strains using the membrane filter and the MPN methods was 0 to 6% and 45 to 133%, respectively. The error rate of the membrane filter method was lower than that of the MPN method. The membrane filter method (m-Endo) showed 10% (11 out of 111) of difference for the detection sensitivity of coliforms isolated from raw water compared to the MPN method (BGLB). The membrane filter method was less affected by the factors including temperature, turbidity, charcoals of powder form, contamination, and reverse pressure. In conclusion, the membrane filter method is a better method for the analysis of total coliforms from raw water than the MPN method, considering the accuracy of detection and the tolerance to various experimental factors.

물놀이형 수경시설의 수질과 항생제 내성 대장균 분포에 관한 연구 (Distribution of Antibiotic Resistant Escherichia coli and Water Quality in Waterscape Facilities)

  • 윤상훈;김선경;김난희;위환;이세행;조광운;김동수;조영관
    • 한국환경보건학회지
    • /
    • 제40권3호
    • /
    • pp.225-233
    • /
    • 2014
  • Objective: This study was performed in order to investigate the distribution of antibiotic resistant E. coli and water quality in waterscape facilities. Methods: Nine waterscape facilities were selected and classified into three types: ground, wall and general fountain. The items analyzed in this study were pH, turbidity, $KMnO_4$ consumption, total colony, total coliforms, fecal coliforms and E. coli. Additionally, an antibiotic resistance test on E. coli was performed. Results: There were no sampling sites that exceeded the permitted limits of water quality, but the concentration of pollutants was high at the beginning operation in June. Moreover, concentration of turbidity, $KMnO_4$ consumption and total colony were higher in ground fountains than in wall and general fountains. Five species of antibiotic resistant E. coli were detected from three sampling sites. Conclusions: The waterscape facilities were significantly contaminated with water microorganisms, especially total colony, total coliforms and fecal coliforms. Disinfection and filtration systems to remove pollutants should be installed for safe waterscape facilities.

아산시 지표미생물의 분포와 Escherichia coli의 항생제 내성에 관한 연구 (A Study of Antimicrobial Resistance in Escherichia coli and the Distribution of Indicator Microorganisms in Asan City)

  • 이근열;김근하;권문주;권혁구;김연희;이장훈
    • 한국환경보건학회지
    • /
    • 제36권3호
    • /
    • pp.229-235
    • /
    • 2010
  • Efforts to evaluate water pollution using indicator microorganisms have been underway for decades, and driven by research on water purity control applications, water quality criteria are growing more and more strict. Furthermore, recent reports indicate that high concentrations of antibiotics are not absorbed, and are present in excrement from animals and humans dosed with unnecessarily high levels of antibiotics. This has emerged as very important issue from the standpoint of being an ecological and health hazard. In this study, water pollution was analyzed through physicochemical and microbiological means, and antibiotic resistance in indicator microorganisms was assessed. In physicochemical analysis, biochemical oxygen demand (BOD)$_5$ and chemical oxygen demand (COD)$_{Mn}$ evaluation showed that pollution by organisms was highest at the G1 location with a high human population, and the DP location which has many livestock-containing households. The indicator organism levels at the G1 location were: Total Coliforms (1205 colony forming units (CFU)/100 ml), Fecal Coliforms (270 CFU/100 ml), Escherichia coli (253 CFU/100 ml) and Fecal Streptococci (210 CFU/100 ml), while for the DP location levels were: Total Coliforms (1480 CFU/100 ml), Fecal Coliforms (438 CFU/100 ml), E. coli (560 CFU/100 ml), and Fecal Streptococci (348 CFU/100 ml). Levels of fecal indicator microorganisms such as Fecal Coliforms, E. coli and Fecal Streptococci were high at all locations in the fall (the period after the rainy season), and the yearly distribution was similar between these organisms. If the number of livestock-containing households was high, almost all strains of E. coli (as distinct from the other indicator organisms) showed resistance to antibiotics, with the degree of resistance varying between areas. E. coli strains from the OY area in particular, which has a high population density, showed strong resistance to AM10 and Va30. While strong antibiotic resistance was observed overall at the DP and OY locations, no resistance was observed at the EB location.

일부 공중화장실 위생설비의 오염지표세균 조사 (The Load of Indicator Bacteria of Sanitary Ware in Public Restrooms)

  • 김종규;김중순
    • 한국환경보건학회지
    • /
    • 제40권1호
    • /
    • pp.63-70
    • /
    • 2014
  • Objective: The purpose of this study was to investigate the occurrence of indicator organisms in essential sanitary ware in public restrooms. Methods: Twelve public restrooms were randomly selected. Samples at three locations (toilet seat, toilet flush handle/lever, and faucet handle) in the restrooms were collected with moistened-sterile cotton swabs and applied to media in order to determine aerobic colony count (ACC), total coliforms, and Escherichia coli. Results: Most of the samples taken in summer showed a higher level of ACC than those taken in winter (p<0.05). Female restrooms showed higher ACC levels on faucet handles and male restrooms on toilet flush handles/levers (p<0.05). Overall, faucet handles contained the greatest level of ACC, followed by toilet seats, whereas the least load was found on toilet flush handles/levers. The ACC level of samples in the restrooms in public parks, subway stations, and educational institutions varied. Total coliforms were identified in about 20% of toilet seats and faucet handles in male restrooms and faucet handles in female restrooms in summer. These locations were also the sites of positive results of E. coli isolation. Conclusions: The public restrooms were significantly more contaminated in summer than in winter. Overall, the most contaminated locations in the restrooms were toilet seats in male restrooms, and faucet handles in female restrooms. Poor hygienic status was indicated by the positive results of total coliforms and E. coli on samples from some sites. Therefore, sanitary control of restrooms should be improved. These results should be confirmed in a larger study that includes more public restrooms.

A Study on the Microbiological Quality of Drinking Water and Changes During Storage

  • Kim, Jong-Gyu
    • 한국환경보건학회지
    • /
    • 제33권6호
    • /
    • pp.517-521
    • /
    • 2007
  • To assess possible risks from the consumption of drinking water from various sources, a survey of the microbiological quality of tap water, commercial bottled drinking water which is exploited from natural mineral water, and natural spring water was conducted. A total of 4 different brands of commercial bottled drinking water, and 4 types of spring water from different sources, and tap water from 4 private houses were tested for four index microorganisms, and the microbial quality changes of the water during the storage at room temperature or refrigerated temperature for 7 days. Aerobic plate counts of all of the initial water samples were still within 100 CFU/ml (drinking water standard of Korea). Total coliforms, fecal coliforms, and E. coli were not detected in all of the water samples at initial. However, aerobic plate counts of three types of spring water and three types of bottled drinking water stored at room temperature showed higher levels than the standards in 5 days. Total coliforms were detected in three types of spring water after one day's storage at room temperature, and in one type of bottled drinking water after 5 days' storage. These results indicate that some of the spring water surveyed are not safe to drink, and the spring water and bottled drinking water after opening the lid should not be stored at room temperature, if they are used for drinking.

해양으로 배출된 하수처리수내 총대장균군의 활성 평가 (Total Coliforms Viability in Effluent of Wastewater Treatment Plant Discharged into the Ocean)

  • 김종민;정원화;정현미;원성민
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.12-18
    • /
    • 2007
  • Difference of total coliforms (TC) survival time of mixed samples (effluent were mixed by seawater or freshwater) were examined in various conditions. The time taken to achieve a 90% reduction in the TC concentration ($T_{90}$) of effluent, high initial TC concentration and low initial TC concentration samples indicated 143.9, 121.9 and 89.6 hours at $25^{\circ}C$, respectively. At $4^{\circ}C$, log removal rate after 336 hours were 0.96, 1.04, and 1.30. TC survival time of effluent-inoculated seawater sample was longer than that of effluent-inoculated freshwater sample in laboratory. At outdoor condition, TC inactivation curves of effluent-inoculated seawater or freshwater samples showed similar patterns. And both of them were greatly influenced by climate condition. There was not enough evidence that TC survived longer in freshwater than sea water. It was unlikely that the salinity of sea water contributed to the inactivation process of TC.

일식 레스토랑 설비와 조리기구의 미생물 오염 실태 분석 (An Analysis Microbiological Contamination on the Facilities and Utilities of Japanese Restaurants)

  • 김기영;박계영;채명희
    • 한국조리학회지
    • /
    • 제15권4호
    • /
    • pp.9-17
    • /
    • 2009
  • 광주 지역 하절기 동안 일식 레스토랑 10곳의 위생 평가를 위해 미생물 검사를 실시하였다. 일식 레스토랑의 설비 및 조리기구 표면에서 swab sampling 방법으로 스폰지로 200개의 도말 표본을 채취하였다. 총 균수, 대장균군, 대장균, 포도상구균, 살모네라균, 리스테리아균을 측정하였다. 그 결과, 대부분의 도말 표본이 미생물과 대장균군으로 오염된 것으로 입증되었다. 오염 정도는 샘플 채취 장소에 따라 달랐다. 심하게 오염된 곳은 바닥, 트렌치, 생선 취급 코너였고, 이러한 표본의 총 균수는 $10^4$ CFU/100 $cm^2$이 넘었다. 바닥, 트렌치, 나무 도마의 대장균군은 $10^3$ CFU/100 $cm^2$이 넘었다. 게다가 대장균군은 행주, 식기, 그리고 생선 및 채소 코너에서도 검출되었다. 대장균은 몇몇 식당의 바닥과 트렌치에서 검출되었다. 포도상구균은 몇몇 식당의 도마, 행주, 바닥, 트렌치에서 발견되었다. 살모넬라균과 리스테리아균은 모든 표본에서 검출되지 않았다. 이러한 결과는 일식 레스토랑에서 위생관리와 소독이 필요함을 보여준다.

  • PDF

충남 서천 패류생산해역에서의 세균학적 위생안전성 평가 (Evaluation of Bacteriological Safety for the Shellfish growing Sea waters in Seocheon Area, Korea)

  • 변한석;송기철;이두석;심길보;임치원
    • 한국수산과학회지
    • /
    • 제43권1호
    • /
    • pp.25-32
    • /
    • 2010
  • A Sanitary survey in an Important shellfish-growing area of Biin Bay in Seocheon-gun Korea, was conducted to evaluate bay conditions and compliance with the bacteriological criteria for areas designated for the production of shellfish for export. Seawater samples were collected monthly at 55 sampling stations established in the survey area from January 2006 to December 2008. Bacteriological water quality did not change in response to a small rainfall (10.0 mm), but it increased abruptly in response to rainfall to 62.5 mm The most probable number (MPN) value for total coliforms and fecal coliforms in 1, 980 seawater samples ranged from <1.8 to >1, 600 MPN/100mL and from <1.8 to 330 MPN/100mL, respectively. The geometric mean and estimated $90^{th}$ percentile value for total coliforms ranged from 2.0 to 10.3 MPN/100mL and from 7.0 to 42.6 MPN/100mL respectively. The geometric mean and estimated percentile value for fecal coliforms ranged from 1.8 to 4.0 MPN/100mL and from 1.9 to 18.3 MPN/100mL, respectively. Accordingly, the bacteriological water quality of Biin Bay met the National Shellfish Sanitation Program (NSSP) and Korea Shel1fish Sanitation Program(KSSP) criteria for areas designated for shellfish production for export in Korea.

경상북도지역 학교지하수 및 정수기통과수의 수질특성에 관한 연구 (A Study on the Characteristics of Water Quality for Groundwater and Purified Water of Several Schools in Gyeongsangbukdo Province)

  • 김숙찬;배헌균
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.575-580
    • /
    • 2011
  • This study characterized water quality of groundwater and purified water used for drinking water in 30 schools in Gyeongsangbukdo Province. The results of the study showed that 43% of groundwater and 45% of purified water were not suitable for drinking. Among them, microbial contaminations were the most serious problem. In raw groundwater, the exceeding rates of total colony counts was the highest in August (53.6%). Purified water samples showed higher rate of exceeding drinking water standard for total colony counts while showing lower rate of exceeding drinking water standard for total coliforms and fecal coliforms in March and August. Overall, proper managements for microbial contaminations are required for both groundwater and purified water. Furthermore, special attention should toward students not to drink water when groundwater or purified water exceeds the drinking water quality standard.

미생물 및 생화학적 질량역적분석에 의한 퇴비화단계별 부숙도 평가 (Assessment of Compost Maturity on Their Different Stages with Microbial and Biochemical Mass Dynamics)

  • ;최홍림
    • 유기물자원화
    • /
    • 제17권4호
    • /
    • pp.36-47
    • /
    • 2009
  • 유기물의 퇴비화과정중 미생물과 이에 관련된 퇴비의 생화학적 질량의 변화는 퇴비화공정 최적화와 최종산물의 품질은 매우 중요하다. 본 연구에서는 퇴비화단계중 미생물과 관련 생화학적 변수의 질량변화가 퇴비부숙도의 기준으로서의 적합성을 평가하였다. 전국 5개 퇴비공장 (용인축협, 양평축협, 논산축협, 전주연초, 지리산낙협)에서 세 단계 (초기, 부숙, 후숙)의 퇴비시료를 채취하여, Total Aerobic Bacteria(TAB), Coliforms, Escherichia coli, Actinomycetes, Fungi 등의 군집농도를 분석하였다. 연구결과, 5개 퇴비공장의 시료에서 Coliforms과 E.coli는 부숙단계에서 급격히 감소되어 후숙단계에서는 완전 사멸되었으나 다른 미생물은 완전 사멸되지 않았다. 그러므로 Coliforms과 E.coli 군집을 부숙도의 기준으로 제시하였다. 미생물탄소질량/질소질량비 (MBC/MBN)는 부숙단계에서 약간 감소하였으며, 후숙 단계에서는 증가하였다. 이는 부숙단계에서 Coliforms, E. coli, Fungi 등의 군집감소 때문으로, 후숙단계에서는 Fungi 및 TAB 군집증가 때문으로 이해된다. 또한 중금속성분 농도는 방선균 군집과 매우 강한 음(陰)의 상관성을 나타내었다. 본 연구의 성과는 Coliforms과 E.coli 군집 농도를 퇴비부숙도 기준으로 제시하였으며, 중금속농도와 미생물군집농도 상관관계를 이용하여 퇴비품질의 평가기준을 제시한 데 있다.

  • PDF