• 제목/요약/키워드: Total Pressure

검색결과 3,991건 처리시간 0.031초

Effects of total pressure and gravity level on the physical vapor transport of $Hg_2Cl_2-Cl_2$ system

  • Choi, Jeong-Gi;Kwon, Moo-Hyun;Kim, Geug-Tae
    • 한국결정성장학회지
    • /
    • 제19권3호
    • /
    • pp.116-124
    • /
    • 2009
  • Our computational studies for the physical vapor transport crystal growth of $Hg_2Cl_2-Cl_2$ system evidence suggests that the PVT growth process exhibits the diffusion-dominated behaviors for aspect ratios more than and equal to 10, which would provide purely diffusive transport conditions adequate to microgravity environments less than $10^{-3}g_0$. Also, the regimes of high temperature difference based on the fixed source temperature of $380^{\circ}C$, where ${\Delta}T$ is relatively large enough for the crystal growth of mercurous chloride, the transport rates do not keep increasing with ${\Delta}T$ but tend to some constant value of $2.12\;mole\;cm^{-2}s^{-1}$. For the aspect ratios of 5, 10, and 20, the transport rate is directly proportional to the total pressure of the system under consideration. For Ar = 5, the rate is increased by a factor of 2.3 with increasing the total pressure from 403 Torr to 935 Torr, i.e., by a factor of 2.3. For both Ar = 10 and 20, the rate is increased by a factor of 1.25 with increasing the total pressure from 403 Torr to 935 Torr.

저압화학기상증착법을 이용한 ZrC 성장에 잔류시간이 미치는 영향 (Residence Time Effect on the Growth of ZrC by Low Pressure Chemical Vapor Deposition)

  • 박종훈;정충환;김도진;박지연
    • 한국세라믹학회지
    • /
    • 제45권5호
    • /
    • pp.280-284
    • /
    • 2008
  • In order to investigate residence time effect on the growth of ZrC film, the ZrC films grew with various system total pressure (P) and total flow rate (Q) by low pressure chemical vapor deposition because residence time is function of system total pressure and total flow rate. Thermodynamic calculations predict that the decomposition of source gases ($ZrCl_4$ and $CH_4$) would be low as increasing the residence time. Thermodynamic calculations results were proved by investigating deposition rate with various residence time. Deposition rate decreased with residence time of source gas increased. Besides, depletion effect accelerated diminution of deposition rate at high residence time. On the other hands, the deposition rated was increased as decreasing the residence time because fast moving of intermediate gas species decrease the depletion effect. The crystal structure was not changed with residence time. However, the largest size of faceted grain showed up to specific residence time and the size of grain was decreased whether residence time increase or not.

블레이드 팁 형상이 터빈 캐스케이드 전압 손실에 미치는 영향에 대한 연구 (Effect of Turbine Blade tip shape on the Total Pressure Loss of a Turbine Cascade)

  • 이기선;박승덕;노영철;김학봉;곽재수;전용민
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.39-45
    • /
    • 2009
  • Leakage flow through turbine blade tip gap causes strong leakage vortex near the blade suction side and induces large aerodynamic losses. In this study, the conventional plane tip and various squealer tip blades were tested in a linear cascade in order to measure the effect of the tip shape on the total pressure loss. Three tip gap clearances of 0.6%, 1.3%, and 2.0% of blade span were tested. Flow measurement was conducted at one chord downstream from the trailing edge with a five-hole probe. Results showed that the leakage vortex was stronger than passage vortex and the mass averaged overall total pressure loss through the cascade was the lowest for suction side blade tip case. For all tested cases, the area averaged overall total pressure loss was increased as the tip clearance increased.

혈압 판별 분석 -위험요인을 중심으로- (The Discriminant Analysis of Blood Pressure - Including the Risk Factors -)

  • 오현수;서화숙
    • 대한간호학회지
    • /
    • 제28권2호
    • /
    • pp.256-269
    • /
    • 1998
  • The purpose of this study was to evaluate the usefulness of variables which were known to be related to blood pressure for discriminating between hypertensive and normotensive groups. Variables were obesity, serum lipids, life style-related variables such as smoking, alcohol, exercise, and stress, and demographic variables such as age, economical status, and education. The data were collected from 400 male clients who visited one university hospital located in Incheon, Republic of Korea, from May 1996 to December 1996 for a regular physical examination. Variables which showed significance for discriminating systolic blood pressure in this study were age, serum lipids, education, HDL, exercise, total cholesterol, body fat percent, alcohol, stress, and smoking(in order of significance). By using the combination of these variables, the possibility of proper prediction for a high-systolic pressure group was 2%, predicting a normal-systolic pressure group was 70.3%, and total Hit Ratio was 70%. Variables which showed significance for discriminating diastolic blood pressure were exercise, triglyceride, alcohol, smoking, economical status, age, and BMI (in order of significance). By using the combination of these variables, the possibility of proper prediction for a high-diastolic pressure group was 71.2%, predicting a normal-diastolic pressure group was 71.3%, and total Hit Ratio was 71.3%. Multiple regression analysis was performed to examine the association of systolic blood pressure with life style-related variables after adjustment for obesity, serum lipids, and demographic variables. First, the effect of demographic variable alone on the systolic blood pressure was statistically significant (p=.000) and adjusted $R^2$was 0.09. Adding the variable obesity on demographic variables resulted in raising adjusted $R^2$to 0.11 (p=.000) : therefore, the contribution rate of obesity on the systolic blood pressure was 2.0%. On the next step, adding the variable serum lipids on the obesity and demographic variables resulted in raising adjusted R2 to 0.12(P=.000) : therefore, the contribution rate of serum lipid on the systolic pressure was 1.0%. Finally, adding life style-related variables on all other variables resulted in raising the adjusted $R^2$to 0.18(p=.000) ; therefore, the contribution rate of life style-related variables on the systolic blood pressure after adjustment for obesity, serum lipids, and demographic variables was 6.0%. Multiple regression analysis was also performed to examine the association of diastolic blood pressure with life style-related variables after adjustment for obesity, serum lipids, and demographic variables. First, the effect of demographic variable alone on the diastolic blood pressure was statistically significant (p=.01) and adjusted $R^2$was 0.03. Adding the variable obesity on demographic variables resulted in raising adjusted $R^2$to 0.06 (p=.000) ; therefore, the contribution rate of obesity on the diastolic blood pressure was 3.0%. On the next step, adding the variable serum lipids on the obesity and demographic variables resulted in raising the adjusted $R^2$ to 0.09(p=.000) ; therefore, the contribution rate of serum lipid on the diastolic pressure was 3.0%. Finally, adding life style-related variables on all other variables resulted in raising the adjusted $R^2$ to 0.12 (p=.000) : therefore, the contribution rate of life style-related variables on the systolic blood pressure after adjustment for obesity, serum lipids, and demographic variables was 3.0%.

  • PDF

Prevalence, Anthropometric Risk Factors, and Clinical Risk Factors in Sarcopenic Women in Their 40s

  • Jongseok Hwang
    • 대한물리의학회지
    • /
    • 제18권2호
    • /
    • pp.23-31
    • /
    • 2023
  • PURPOSE: This study examined the anthropometric and clinical risk factors and the prevalence of sarcopenia in women aged 40 to 49 years. METHODS: The study design is a cross-sectional research and a total of 2,055 participants were included. The participants were divided into two groups based on their skeletal muscle mass index score. One hundred and twenty-six individuals were assigned to a sarcopenia group, and 1,939 were assigned to a normal group. The following variables were analyzed: age, height, weight, body mass index, waist circumference, skeletal muscle mass index anthropometric measure, systolic blood pressure, diastolic blood pressure, blood laboratory tests, fasting glucose, triglyceride, total cholesterol, and smoking and drinking smoking statuses. RESULTS: The prevalence of sarcopenia was 6.5% (95% CI: 5.33-7.92). Anthropometric variables, such as height, BMI, and waist circumference, showed significance differences between the two groups (p < .05), except for weight variable (p > .05). In terms of blood pressure and blood lab tests, the systolic blood pressure, diastolic blood pressure, fasting glucose, triglyceride, and total cholesterol were all significant risk factors for sarcopenia in the two groups. (p < .05). CONCLUSION: This study identified risk factors and the prevalence of sarcopenia among community-dwelling middle-aged women.

충동터빈과 반동터빈 캐스케이드에서의 팁 간극 손실에 대한 비교 연구 (Comparative Study of Tip Clearance Loss in Impulse and Reaction Turbine Cascades)

  • 박경욱;정은환;송성진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.145-148
    • /
    • 2008
  • 현재 항우연에서 개발 중인 우주발사체 터보펌프에 사용되는 터빈은 단단 충동터빈을 적용하고 있다. 우주발사체의 안정성을 위해 팁 간극을 비교적 많이 허용하고 있는데, 효율적인 면에서는 반동터빈 보다 다소 뒤지지만, 높은 출력비를 가지는 충동터빈이 팁 간극이 커질 때 어떤 효율경향을 나타내는지 알아보는 일은 의미 있는 일이다. 실험은 아음속 조건에서 실험하였고, 팁 간극을 각각 코드기준 1%$\sim$20%일 경우 충동과 반동 각각의 경우에 대하여 하류 전압손실을 측정하였다. 측정결과 팁 간극이 10%보다 더 커지면, 충동터빈이 오히려 전압손실량이 반동터빈보다 더 작아진다. 이것은 팁 간극이 비교적 큰 조건에서 충동터빈이 반동터빈보다 효율이나 출력비 면에서 더 나은 성능을 나타냄을 의미한다.

  • PDF

무릎 폄근 강화 운동 동안 압력 생체되먹임 장비 적용이 무릎관절 전치환술 환자들의 근력과 균형에 미치는 영향 (Effects of Pressure Biofeedback Unit Application on Muscle Strength and Balance in Total Knee Arthroplasty Patients during Exercise for Strengthening the Knee Extensor Muscle)

  • 박진;박한규
    • 대한통합의학회지
    • /
    • 제9권1호
    • /
    • pp.101-108
    • /
    • 2021
  • Purpose : The purpose of this study is to verify the effect of selective muscle strengthening of the knee joint extensor muscles using a pressure biofeedback unit to improve knee extensor strength and the balance ability of total knee replacement patients. Through this, we tried to provide clinical information. Methods : In this study, 12 patients with total knee replacement were recruited from a rehabilitation hospital. They were divided into two groups: a feedback group (n=6) and a control group (n=6). All patients received 30 minutes of continuous passive motion and leg-strengthening exercises for 15 minutes five times a week for two weeks. Subjects performed knee extension exercises with or without biofeedback units in the sitting position. The knee extensor strength and balance ability were measured before and after exercise. Knee extensor strength was measured by Biodex system 3 and balance ability was measured by Balancia software. Results : Both the experimental group and the control group showed a significant difference in the muscle strength of the knee joint extensor muscles after intervention (p<.05). In comparison, the experimental group showed a significant difference than the control group (p<.05). Both the experimental group and the control group showed a significant difference in the velocity average, path length, area 95 % center of pressure (COP), weight distribution, five times sit to stand test (FTSST) after intervention. In comparison, the experimental group showed a significant difference in velocity average, area 95 % COP, and FTSST than the control group (p<.05). Conclusion : In order to strengthen the knee extensor muscle and improve the balance ability in total knee replacement patients, it is necessary to consider providing pressure biofeedback unit during leg strengthening exercises.

주기적 선회실속이 발성하는 축류홴의 3차원 유동구조 (Three Dimensional Flow Structure under Rotating Stall in an Axial Flow Fan)

  • 강창식;신유환;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.105-110
    • /
    • 2002
  • Experimental study was conducted to reveal the instability such as leakage flow and rotating stall in an axial flow fan. For this study, unsteady total pressure probe and multi-hole pressure probe were specially designed for measuring the flow field upstream and downstream of rotor. The measured pressure signal was analyzed by Single and Double Phase Locked Averaging Technique. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the structure of the stall cell in radial direction was provided. Also, detailed flow measurements were carried out with a specially designed high frequency multi-hole pressure probe, providing some insight to the leakage flow and their interation.

  • PDF

증기발생기 전열관의 파열강도에 미치는 외압의 영향 (Effect of External Pressure on the Burst Strength of Steam Generator Tube)

  • 조성근;배봉국;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.353-358
    • /
    • 2004
  • Tracing the study of the burst test of steam generator tube, few studies have been reported to effect of external pressure acting on secondary-side in service condition. In this study the burst tests of Inconel 690TT were conducted in order to evaluate burst strength characteristics under the effect of external pressure. We obtained the result that the burst strength of Inconel 690TT increased when external pressure increased while both total circumferential elongation and uniform burst elongation were not affected. Also, according to the increased of external pressure, the size of the burst opening became smaller and the tear was getting severe.

  • PDF

압력포텐샬을 이용한 초탄성 유한요소 정식화 (Hyperelastic Finite Element Formulation using Pressure Potential)

  • 김헌영;김호;김중재
    • 대한기계학회논문집A
    • /
    • 제26권12호
    • /
    • pp.2492-2502
    • /
    • 2002
  • A rubber-like material model is generally characterized by hyperelasticity and formulated by a total stress-total strain relationship because the material shows nonlinear elastic behaviour under large deformation. In this study, a pressure potential obtained by a separately interpolated pressure is introduced to the non-linear finite element formulation incorporating with incompressible or almost incompressible condition of the material. The present formulation is somewhat different from the general formulation using the pressure computed in the displacement field. A non-linear finite element analysis program is developed for the plane strain and the axisymmetric contact problems of a rubber-like material. Various examples with rubber material are analyzed for its verification. The results about deformed shapes and stress distributions thought to be meaningful in comparison with a commercial program, MARC.