• 제목/요약/키워드: Total Measuring Accuracy

검색결과 142건 처리시간 0.028초

초분광 광학가시화 기술을 활용한 인공지능 산소온도 측정기술 개발 (Development of AI oxygen temperature measurement technology using hyperspectral optical visualization technology)

  • 이정훈;김보라;이승훈;김준식;윤민;조경래
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.103-109
    • /
    • 2023
  • This research developed a measurement technique that can measure the oxygen temperature inside a high temperature furnace. Instead of measuring only changes in frequency components within a small range used in the existing variable laser absorption spectroscopy, laser spectroscopy technology was used to spread out wavelength of the light source passing through the gas Based on a total of 20,000 image data, research was conducted to predict the temperature of a high-temperature furnace using CNN with black and white images in the form of spectral bands by temperature of 25 to 800 degrees. The optimal model was found through Hyper parameter optimization, R2 score is 0.89, and the accuracy of the test data is 88.73%. Based on this research, it is expected that concentration measurement and air-fuel ratio control technology can be applied.

총자력계를 이용한 선상 삼성분 자기 데이터의 선박 점성 자화 효과에 대한 새로운 보정 방법 연구 (A New Correction Method for Ship's Viscous Magnetization Effect on Shipboard Three-component Magnetic Data Using a Total Field Magnetometer)

  • 최한진
    • 지구물리와물리탐사
    • /
    • 제27권2호
    • /
    • pp.119-128
    • /
    • 2024
  • 해양자력탐사는 다른 탐사법에 비해 측정이 간편하여 해저 지구조 및 광상자원 분포 등의 탐사에 개척자 탐사로 주요하게 사용되는 방법이다. 측정은 주로 해수면 견인 자력계와 선상 삼성분 자력계를 주로 사용하고 있다. 해수면 견인 자력계는 분해능이 높다는 장점이 있지만 독자적인 연구선을 사용해야 하고, 자기장의 세기 만 측정할 수 있는 반면, 선상 삼성분 자력계는 상대적으로 분해능이 낮지만 자기장의 벡터 삼성분을 측정할 수 있고 연구선을 단독으로 사용하지 않아도 자료를 획득할 수 있다는 큰 장점을 가지고 있다. 하지만, 선상 삼성분 자력계는 선박의 자성 영향으로 인해 측정된 자료의 까다로운 보정이 필요하다. 현재까지 다양한 방법론이 제시되었지만 점성자화의 영향으로부터 벡터 삼성분의 보정이 불가능하였다. 본 연구에서는 해수면 견인 총 자력계와 선상 삼성분 자력계를 동시에 획득하였을 경우, 회전행렬을 통하여 간단하게 선상 삼성분 자력계로 얻은 자료를 해수면 견인 자력계로 얻은 자료로 바꿔 줌으로써 선박의 점성자화 성분을 효과적으로 제거하여 벡터 삼성분 자력이상 자료를 근사하여 보정하는 방법을 고안하였다. 오차분석을 통해 약 7-25 nT의 오차가 발생한 것을 확인하였는데 이는 지자기 이상 벡터의 잔여성분과 이로부터 유도되는 점성자화의 영향으로 여겨진다. 이 방법은 해양지자기의 정확한 벡터성분을 제공함으로써 지자기 이상 벡터성분의 다양한 해석을 가능하게 할 뿐만 아니라, 판 이동 및 지질 구조 연구, 해양 자원 개발 등 탐사의 정확성 향상에 크게 기여할 것으로 기대된다.

온실 공기유동 계측 시스템 개발 (Development of Device Measuring Real-time Air Flow in Greenhouse)

  • 노재승;권진경;김유용
    • 생물환경조절학회지
    • /
    • 제27권1호
    • /
    • pp.20-26
    • /
    • 2018
  • 작물생육의 품질 및 생산량에 중요한 영향을 미치는 온실 내 환경관리에 대한 연구는 활발히 진행되고 있다. 주로 온실 내 환경분포를 측정하는 방법으로는 한 두 지점에 대해서만 측정하여 온실 전체를 관리하는 시스템으로 이루어졌으며 기존 환경데이터 측정방식은 각각의 데이터 로거 및 센서간의 배선들로 인하여 복잡한 시스템으로 구성되었다. 본 연구에서는 온실 내 설치 된 각 환경센서들로부터 지점별 데이터를 획득하고 획득된 데이터는 모니터링 프로그램을 통하여 공기유동흐름을 측정하는 장치를 개발하였다. CAN 네트워크 통신을 통하여 환경센서들의 배선 토폴로지를 간소화 했으며 프로토콜의 견고함으로 온실 내 모니터링을 안정적으로 데이터를 수집할 수 있도록 구현되었다. 온실 내 공간의 환경요인 분포(온 습도 및 풍속 등)들을 12개 지점에 배치하고 온 습도 및 풍속의 환경 데이터는 상세히 파악할 수 있도록 X, Y, Z 축으로 다수의 측정점(총 36점)을 선정하였다. 데이터 손실 및 다양한 온실조건을 고려하여 비트레이트를 저속 125kbit/s로 구현하여 온실 내 100m 구역내에서 센서를 추가적으로 연장(총 90개)할 수 있도록 구축되었다. 온도, 습도, 일사량, 풍향, 풍속, 대기압 및 강우량 등 측정된 데이터는 LabVIEW에 연동되어 실시간으로 센서 정보 출력이 가능하도록 구현되었다. 온실 내 환경 분포는 사용자의 편의에 따라 환경분포를 수평(XZ), 수직(YZ)축으로 가시화 할 수 있으며, 보간의 범위를 원하는 값으로 설정하여 보간 할 수 있도록 구현되었다. 추후에 온실 내의 공간에 따라 온도, 습도, 풍속, $CO_2$ 등의 환경 측정 실험을 통하여 CFD 모델링과의 검증 및 비교에 활용할 수 있을 것으로 판단된다.

치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향 (Effect of interproximal undercut on the dimensional accuracy of impression)

  • 이주리;김석규
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.330-336
    • /
    • 2015
  • 목적: 본 연구의 목적은 치간 유두의 소실로 인해 치아 사이에 언더컷이 존재하는 경우 이것이 인상체의 정확도에 영향을 미치는지 알아보고자 하는 것이다. 재료 및 방법: 2종류의 부가중합형 실리콘 인상재($Extrude^{(R)}$ Wash, $Imprint^{TM}$ II Quick Step Light Body)와 한 종류의 알지네이트 인상재(Cavex Impressional)로 상악 주모형의 인상을 채득하여 얻은 실험모형상의 두 점 사이의 거리를 측정하여 주모형과 비교하여 모형의 변형 정도를 측정하였다. 세 종류의 인상재에서 얻은 실험 모형들을 치간 유두가 존재하는 군과 존재하지 않는 군으로 나눠 총 6개의 군을 평가하였으며, 각 군당 6개의 모형을 측정하였다. 삼차원 광학 스캐너로 실험모형을 스캔한 후, 하나의 모형당 6개의 두 점 사이의 거리를 삼차원 디지털 계측 소프트웨어 상에서 측정하였다. 측정 거리의 변화 정도를 백분율로 계산하여 모형의 변형률을 구하였으며, 이것을 이원분산분석을 이용하여 유의수준 .05에서 분석하였다. 결과: 측정거리 6개 중 3개에서 인상재에 따라 통계적으로 유의한 차이를 보였다. 반면, 치간 유두의 존재 여부에 따른 차이는 알지네이트 인상재에서 하나의 측정 거리에서만 유의한 차이를 보였을 뿐(P=.047), 다른 측정거리들과 인상재에서는 통계적으로 유의성 있는 차이를 나타내지 않았다. 결론: 치간 유두의 소실로 인한 언더컷의 존재가 부가중합형 실리콘 인상재와 알지네이트 인상재의 체적 정확도에 미치는 영향은 크지 않았다.

노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법 (A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image)

  • 고국원;김민영
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.909-916
    • /
    • 2009
  • 본 연구는 위상천이 영사식 모아레 측정기의 기준 위상 측정단계에서 기준 위상의 검출 정확도를 높이기 위한 방안으로, 일반적인 N-bucket 방법이 아닌, 줄무늬 패턴 투사 영상의 직접적인 영상처리를 기반으로, 노이즈가 포함된 영상으로부터 기준 위상을 자동으로 검출하고 보정하는 방법을 다룬다. 일반적으로 기준위상을 정확히 구하기 위해서는 상대적으로 노이즈가 원천적으로 적은 고정밀도의 교정 시편과 이에 맞는 세분화된 교정방법이 필요하다. 하지만, 고가의 시편 제작비용 절감과 고정도 교정을 위한 교정시간의 단축을 위해, 상대적으로 일반 정밀도등급의 제작된 시편으로부터 획득된 영상을 이용하여, 효율적인 기준위상 교정 방법을 제안한다. 투사된 평행 라인 띠가 시편에서 반사되어 카메라로 입력되는 영상으로부터, 영상처리 라인마스크를 이용하여 격자 라인들의 중심점을 정밀하게 추출하고, 각 라인들에서 추출된 샘플링점 기반의 최소자승법을 이용하여, 라인 특징치인 기울기와 절편을 추출함으로써 실제 관측되는 격자 라인의 중심선을 획득하였으며, 획득된 중심선들을 이용하여 N-bucket 알고리즘에 적용할 수 있도록 위상을 추출한 후, 기준위상을 자동으로 생성하였다. 본 연구를 통하여 고가의 시편 제작 없이 빠르게 자동으로 기준위상을 추출할 수 있었다.

백미의 총 식이섬유함량 예측 모델 개발을 위한 퓨리에변환 근적외선분광계의 적용 (Application of Fourier Transform Near-Infrared Spectroscopy for Prediction Model Development of Total Dietary Fiber Content in Milled Rice)

  • 이진철;윤연희;은종방
    • 한국식품저장유통학회지
    • /
    • 제12권6호
    • /
    • pp.608-612
    • /
    • 2005
  • 친환경적이면서 신속한 비파괴 분석방법인 FT-NIR를 이용하여 백미의 총식이섬유(TDF)함량 예측모델을 개발하였다. 백미는 국내산으로 전남지방에서 재배된 47개 품종과, 시중 유통 중인 13개 브랜드 미에 대해서 AOAC 방법에 준한 효소법에 의해 TDF 함량을 분석하였다. 습식 분석된 TDF함량의 범위는 $1.17-1.92\%$ 이었다. FT-NIR로 측정된 스펙트럼의 검량식은 빛의 산란 효과를 최소화하기 위해 수학적 처리를 하였고, 몇 개의 특정 파장이 아닌 전 파장 영역(1,000-2,500 nm)에 대해서 PLS법으로 작성하였다. 얻어진 검량식의 정확도는 상관계수(r), SEE 및 SEP로 확인하였다. 백미 중 총 식이섬유 함량에 대한 회귀분석을 행한 결과, 검량식의 r은 0.9705, SEE는 0.0464, 검증식의 bias는 -0.0006, SEP가0.0604로 측정 정확도가 우수하여 실제 적용이 가능함을 보여주었다.

청색증형 선천성 심질환아의 고식적 수술 이후 EBT에 의한 폐혈관계이 비침습적 추적 검사 (Non-invasive Fdlow-up of Pulmonary artey by EBT Other Palliatrve Shunt Operatin)

  • 김민정;박영환;홍유선;이종균;최규옥;조범구
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.7-19
    • /
    • 2000
  • Background :To assess the accuracy of Electron-Beam Tomography(EBT) in following evaluation of the pulmonary vascular system after a shunt operation in the cyanotic con-genital heart disease with pulmonary stenosis or pulmonary atresia. Material and Method : Sixteen patients(M:F=11:5) who received Blalock-Taussig(n=8) bidirectional cavo-pulmonary shunt(n=10) and unifocalization (n=2) were ncluded in the study. We evaluated the patency of the shunt the morphology of intrapericardial and hilar pulmonary arteries(PA) peripheral pulmonary vascularity by background lung attenuation and the abundance of arterial & venous collateral. Angiography(n=12) and echocardiography(n=20) were used as the gold standard for the comparison of EBT results. Result: EBT was consistent with angiogram/ echo in 100% of the evaluation for the patency of the shunt and in 12(by angiogram 100%) and 19(by echo 95%) for the detection the hypoplasia stenosis or interruption of central PA In measuring of PA EBT and angiogram corrlated(r=0.91) better than EBT-echo(r=0.88) or echo-angiogram(r=0.72) Abundant systemic arterial collateral were noted in 4 and venous collateral in 3 cases. In evaluating the peripheral pulmonary vascularity the homogenous and normal-ranged lung attenuation(m=6) decreased but homo-genous attenuation(n=1) segment-by-sgment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) segment-by-segment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) and venous congestion(n=2) were observed nd 12 of them were compatible with the blood flow pattern revealed by cardiac catheterization. Conclusion: EBT was accurate in the integrated evaluation of the pulmonary vascular system after the shunt including the patency of the shunt operaion the morphology and dimension of the central and hilar PAs and the loco-regional pulmonary flow in the lung parenchyma. It suggests the useful information about the need of secondary shunt operation the proper timing time for total repair and the need of interventional procedure prior to total repair.

  • PDF

파노라마 방사선사진상에서 경상돌기의 변이에 관한 연구 (A STUDY ABOUT THE VARIATION OF STYLOID PROCESSES IN PANORAMIC RADIOGRAPHS)

  • 오숙희;김종열
    • 치과방사선
    • /
    • 제18권1호
    • /
    • pp.193-201
    • /
    • 1988
  • The purpose of this study was to investigate the variation in the length and shape of styloid processes and the relationships between the elongated styloid processes and the styloid process syndrome, using panoramic radiogrpahs and questionaires. The subjects were 342 patients consisted of 170 males and 172 females aged from 11 to 78 years, not showing facial asymmetry, who visited infirmary of dental college of Yonsei University. Also, the accuracy was determined for measuring the length of styloid processes from panoramic radiographs, using dried skulls. The results were as follows: 1. The length of styloid processes was magnified approximately 1.1 times, but there was no statistically significant differencies in the magnification rate of length between right and left side. 2. The mean radiographic length of styloid processes was 29.72±7.92㎜ in males, 27.93±6.69㎜ in females, and 28.82±7.37㎜ in total. And elongated styloid process (>30㎜) was seen in 31.3% of total subjects. 3. The growth in the length of styloid processes was completed in the third decade. 4. The most common shape of styloid processes was straight followed by segmented and bent form. The incidence of segmentation was reduced with increasing age. 5. The 74% of subjects with elongated styloid process (>30㎜) showed symptoms of the styloid process syndrome. The most frequent symptom was headache followed by discomfort in the neck when turning the head from left to right, tinnitus or earache, vague facial pain, discomfort or pain when swallowing, feeling that an object is caught in throat.

  • PDF

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제43권5호
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Calibration Update for the Measuring Total Nitrogen Content in Rice Plant Tissue Using the Near Infrared Spectroscopy

  • Kwon, Young-Rip;Song, Young-Eun;Choi, Dong-Chil;Ryu, Jeong
    • 한국작물학회지
    • /
    • 제54권1호
    • /
    • pp.29-35
    • /
    • 2009
  • The aim of the present study was to update the calibration that is used for the measurement of the total nitrogen content in the rice plant samples by using the visible and near infrared spectrum. Before the equation merge, correlation coefficient of calibration equation for nitrogen content on each rice parts was 0.945 (Leaf), 0.928 (Stem), and 0.864 (Whole plant), respectively. In the calibration models created by each part in the rice plant under the various regression method, the calibration model for the leaf was recorded with relatively high accuracy. Among of those, the calibration equation developed by Partial least squares (PLS) method was more accurate than the Multiple linear regression (MLR) method. The calibration equation was sensitive based on variety and location variations. However, we have merged and enlarged various of the samples that made not only to measure the nitrogen content more accurately, but also later sampling populations became more diversified. After merging, $R^2$ value becomes more accurate and significantly to 0.950 (L.), 0.974 (S.), 0.940 (W.). Also, after removal of outlier, R2 values increased into 0.998, 0.995, and 0.997. In view of the results so far achieved, Standard error of prediction (SEP) and SEP (C) were reduced in the stem and whole plant. Biases were reduced in the leaf, stem as well as whole plant. Slopes were high in the stem. Standard deviation reduced in the stem but $R^2$ was high in the stem and whole plant. Result was indicated that calibration equation make update, and updating robust calibration equation from merge function and multi-variate calibration.