• Title/Summary/Keyword: Total Measuring Accuracy

Search Result 142, Processing Time 0.029 seconds

Improvement of Activity Recognition Based on Learning Model of AI and Wearable Motion Sensors (웨어러블 동작센서와 인공지능 학습모델 기반에서 행동인지의 개선)

  • Ahn, Junguk;Kang, Un Gu;Lee, Young Ho;Lee, Byung Mun
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.8
    • /
    • pp.982-990
    • /
    • 2018
  • In recent years, many wearable devices and mobile apps related to life care have been developed, and a service for measuring the movement during walking and showing the amount of exercise has been provided. However, they do not measure walking in detail, so there may be errors in the total calorie consumption. If the user's behavior is measured by a multi-axis sensor and learned by a machine learning algorithm to recognize the kind of behavior, the detailed operation of walking can be autonomously distinguished and the total calorie consumption can be calculated more than the conventional method. In order to verify this, we measured activities and created a model using a machine learning algorithm. As a result of the comparison experiment, it was confirmed that the average accuracy was 12.5% or more higher than that of the conventional method. Also, in the measurement of the momentum, the calorie consumption accuracy is more than 49.53% than that of the conventional method. If the activity recognition is performed using the wearable device and the machine learning algorithm, the accuracy can be improved and the energy consumption calculation accuracy can be improved.

LAND SLIDE DISPLACEMENT DETECTION USING TIME SERIES DIGITAL SURFACE MODEL ACQUIRED BY A TERRESTRIAL LASER SCANNER

  • Jeong, Jong-Hyeok;Takagi, Masataka
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.567-569
    • /
    • 2006
  • Recently, the terrestrial laser scanner is considered as useful measurement equipment for acquiring a three-dimensional data. In this study, a terrestrial laser scanner which has +/- 2.5cm accuracy is examined whether the terrestrial laser scanner is reliable to present the tendency of landslide movement. The test area is covered by protection blocks, and they are being moved by landslide movement. Landslide movement was detected by measuring the movement of protection blocks. Totally three scenes of test area were acquired during 2004 and 2006. The three scenes of the protection blocks were registered in global coordinate system, then the landslide movement was investigated. The landslide movement detected in the three scenes was evaluated by comparing with landslide movement measured by a total station. Although the measurement accuracy of landslide using the terrestrial laser scanner was worse than the total station, the scanning data showed the tendency of landslide movement of the test area.

  • PDF

Monitoring-Evaluation System for Lifting Heavy Structures using 3D Location Data (3차원 위치좌표를 이용한 대형 구조물 양중을 위한 계측 - 평가 시스템)

  • Lee, Myung Ho;Chun, Sung Chul;Oh, Bohwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.413-420
    • /
    • 2009
  • Heavy structures such as large roof structures and superbeams were lifted using hydraulic jacks. Moreover, member verticality and horizontality checks were performed at every construction stage to monitor the measuring tapes for their structural safety, using CCTV. When the relative displacement exceeded the predetermined limit, the hydraulic systems were terminated. After adjusting the relative displacement manually, lifting was resumed. The accuracy of the relative displacement was found not to be reliable, however, due to eye check using CCTV, and it took a long time due to manual adjustment. Moreover, real-time monitoring was impossible. To address these problems, the monitoring-evaluation system for the stable lifting of heavy structures was proposed, using the total station of the automatic-target-recognition type, laser-distance-measuring devices, a data logger, a strain gauge, and others. After developing a program for the operation of the system and for the acquisition of data, a mock-up test was conducted in a large-scale structural laboratory to evaluate the accuracy and applicability of the system. The stable acquisition and applicability of data was confirmed in the test.

THE EFFECTS OF SPURE AND INVENTS ON THE CASTING ACCURACY AND POROSITY OF TI-NI CASTINGS

  • Cho Lee-Ra;Yi Yang-Jin;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.342-350
    • /
    • 2003
  • Statement of problem. Titanium-Nickel alloy might be used in various prosthetic restorations since it has a unique property such as super-elasticity and high fatigue resistance. However, little is known about the casting ability of this alloy. Purpose. This in vitro study compared the casting accuracy and the porosity made with different investments and various sprue designs to ascertain what casting condition would be better for the fabrication of Ti-Ni cast restorations. Material and methods. A total of 70 Ti-Ni alloy crowns were made and divided into 7 groups of 10 copings on a metal master die. For measuring the effect of the sprue numbers, two groups with one and two 8-gauge sprues were compared. Moreover, the results of the conventional sprue and the double thickness sprues were compared. Three investments were used; carbon free phosphate bonded investment, titanium investment and gypsum bonded investment. The cast restorations were evaluated at 48 points on the entire circumferential margin with a stereomicroscope measuring in micrometers. Each crown was radiographically examined for casting defects and porosity. Data on casting accuracy were analyzed using two-way and Post hoc Scheffe's comparison to determine whether significant differences existed at the 95% confidence level. Student-Newman-Keuls test were performed to identify significant differences in the number of voids. Results. The double sprueing group and double thickness group had significantly less marginal discrepancy than the single sprueing group (P<.05 and P<.01, respectively). The castings with phosphate bonded investment showed the least marginal discrepancy and the smoothest surface. The castings invested in the gypsum bonded investment had the greatest gaps in margin and the largest failure rate. The double sprueing group and phosphate bonded investment group had significantly smaller void numbers and smaller void size than the other groups. Conclusion. Within the limitations of this in vitro study, the casting accuracy of the groups using thicker, double sprue design and the phosphate bonded investment was significantly superior. Moreover, void number and size were less than other groups.

Improvement of Intermittent Advancing Accuracy of Pneumatic Cylinder-Driven Roll Feeder

  • So, Jung Duck
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.3
    • /
    • pp.164-170
    • /
    • 2016
  • A proposed pneumatic cylinder-driven roll feeder and an air press were designed to be operated automatically by a PLC. The accuracy of the intermittent feed pitch of the roll feeder was evaluated by measuring lengths of cut-offs of a strip stock by a digimatic vernier caliper. At each predetermined feed pitch, the proposed roll feeder was tested 100 times by varying the feed/cut intervals as 2.0/1.5, 3.0/2.0, and 3.5/2.5 s as test sets. The lengths of the cutoffs of the strip stock ranged from 9.89-10.34, 12.1-12.65, and 15.21-15.67 mm at the predetermined 10, 12, and 15 mm feed pitch, respectively, among the total of 300 samples in each feed pitch, regardless of the feed/shear interval. Therefore, the feed/cut interval at each selected feed pitch was found to have no effect on the accuracy of the intermittent advancing of the strip stock.

The Effects of Core Strengthening Training on Baseball Throwing

  • Lee, Han Ki;Jung, Da Eun;Lee, Jun Cheol
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.1
    • /
    • pp.965-971
    • /
    • 2016
  • The purpose of this study was to investigate the effects of core strengthening training on baseball throwing. A total of 14 subjects were recruited from among middle school baseball players. The main outcome measures were as follows: speed guns were used to measure the velocity of baseballs thrown; scored targets were used to measure throwing accuracy; and 50m measuring tapes were used to measure throwing distances. It was found that core strengthening training improved the velocity of baseballs thrown and throwing accuracy and distance. Thus, core strengthening training is effective for improving the throwing ability of baseball players.

Development of a Delirium Occurrence Screening Model for Patients in Medical Intensive Care Units (내과계 중환자 섬망발생 선별모형 개발)

  • Lee, Hyun Sim;Kim, So Sun
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.3
    • /
    • pp.357-368
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate risk factors related to delirium and to develop screening model on delirium occurrence in MICU (Medical Intensive Care Unit) patients. Methods: For developing a preliminary tool for delirium, the data of 166 patients were collected and analyzed. In order to estimate the accuracy and discriminating power for the developed screening model, 98 patients were enrolled. The data used in this study were collected by EMR (Electronic Medical Record) review from January to September in 2012. The collected data were analyzed using SPSS/PC Win 18.0 program. Results: Screening model on delirium in MICU patients was developed using the results of logistic regression. The total score of screening model was 24 point and measuring point was 10 point. When the measuring point is over 10 point, it means that the risk of delirium occurrence is high. The discriminating power and the validity of screening model showed AUC .908 (p <.001) and .935 (p <.001) respectively. This result showed that the screening model on delirium which developed in this study was an appropriate model for screening the delirium risk group in MICU. The sensitivity of the screening model was 83%, specificity 89% and accuracy 84%. Conclusion: The developed screening model on delirium occurrence in MICU should be combined with EMR for screening and preventing delirium in a high risk group.

Analysis of Accuracy and Productivity of Terrestrial Laser Scanner for Earthwork (3차원 스캐너의 토공현장 적용을 위한 정밀도 및 생산성 분석)

  • Kim, Seok;Park, Jae-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.10
    • /
    • pp.587-596
    • /
    • 2015
  • 3D scanners are applied to many industries, such as manufacturing, construction, and shipbuilding. Recently, 3D scanner is used in 3D imaging of worksite in order to control and guide earthmoving heavy equipments, which provides basic information for intelligent excavation. This study compares the accuracy and productivity between total stations and high-resolution 3D scanners. The analysis results show that 3D scanner has high accurate rate of greater than 99 percent and has low error rate of less than 2.0mm compared to total stations. In terms of productivity, 3D scanner saves 71 percent of measuring time compared to the total station. This study confirms that 3D scanner can measure the earthwork sites with high accuracy and better productivity.

Development of Elimination Method of Measurement noise to Improve accuracy for White Light Interferometry (백색광 간섭계의 정밀도 향상을 위한 노이즈 제거 방법)

  • Ko, Kuk-Won;Cho, Soo-Yong;Kim, Min-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.519-522
    • /
    • 2008
  • As industry of a semiconductor and LCD industry have been rapidly growing, precision technologies of machining such as etching and 3D measurement are required. Stylus has been important measuring method in traditional manufacturing process. However, its disadvantages are low measuring speed and damage possibility at contacting point. To overcome mentioned disadvantage, non-contacting measurement method is needed such as PMP(Phase Measuring Profilometry), WSI(white scanning interferometer) and Confocal Profilometry. Among above 3 well-known methods, WSI started to be applied to FPD(flat panel display) manufacturing process. Even though it overcomes 21t ambiguity of PMP method and can measure objects which has specular surface, the measuring speed and vibration coming from manufacturing machine are one of main issue to apply full automatic total inspection. In this study, We develop high speed WSI system and algorithm to reduce unknown noise. The developing WSI and algorithm are implemented to measure 3D surface of wafer. Experimental results revealed that the proposed system and algorithm are able to measure 3D surface profile of wafer with a good precision and high speed.

Automatic Inspection of Assembly Tolerances of Cathod Ray Electron Guns by Vision Probe (비젼프로브를 이용한 CRT 전자총의 자동치수 검사)

  • Park, H.G.;Park, M.C.;Kim, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.28-34
    • /
    • 1997
  • This paper describes an automatic measurement method for the in-line inspection of assembly tolerances of cathod ray electron guns. The method uses an optical microscope with a CCD camera as a probe. An automatic gap recognition algorthm with digital image processing and a new software autofocus algorithm based on using an optimal edge detector have been developed to improve the measuring accuracy. An inspection system has been proposed and practically implemented for in-line inspection to a real factory automation line. The inspection system consists of a gap inspection part and an eyelet. Total time consumed for inspecting all measuring items is about 10 seconds and the repeatability is below .+-. 5 .mu. m

  • PDF