• 제목/요약/키워드: Total Floor Area

검색결과 247건 처리시간 0.024초

LCC를 이용한 공조 방식별 비교 연구 (Comparison Study of Air-conditioning Systems using LCC Analysis)

  • 김종국;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.12-18
    • /
    • 2012
  • The purpose of this study is to make an economic analysis(Life cycle cost) of selecting optimal air conditioning system for a research building which is 8 stories with a total floor area of $32,010m^2$. Energy consumptions of three proposed air-conditioning systems(Alt-1,2,3) that reflect the government green-growth policy are calculated and compared. The results show that life cycle cost of Alt-3(Ventilation DX AHU+EHP) is less than Alt-1(EHP+ventilation DX AHU) by 5.1%, and Alt-2(Absorption chiller/heater+EHP) by 34.3%. Annual energy consumption of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 37.4%. Annual $CO_2$ emission of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 0.2%.

국내 종합병원의 에너지 사용량에 영향을 미치는 요인 도출 (Study on the elements affecting energy consumption of general hospitals in Korea)

  • 정다운;김선숙;김혜기;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.63-71
    • /
    • 2020
  • Purpose : The purpose of this study is to analyze the elements that affect the energy consumption of general hospitals in Korea. Methods : Factors affecting energy consumption in general hospitals include facility elements and operating elements. The effects of these elements on energy consumption of general hospitals were analyzed by statistical methods such as t-test, anova, correlation analysis, and regression analysis. Results : Total floor area, number of operating rooms, number of MRI, number of staffs, and number of outpatients can be said as useful variables that can explain energy consumption in general hospitals. Implication : It is possible to save energy consumption in general hospitals by adjusting major variables that affect the energy consumption of general hospitals.

A Systematic Review of the Mechanical CPR and Manual CPR on Out-of-Hospital Cardiac Arrest Occurring in High-rise Building

  • ChanHo, Lee;ByounGgil, Yoon;HongBeom, Ahn;YongSeok, Kim
    • International Journal of Advanced Culture Technology
    • /
    • 제10권4호
    • /
    • pp.434-443
    • /
    • 2022
  • CPR in High-rise building is one of the challenging tasks to 119 paramedics, evacuating patient from the narrow and vertical area. This study was built to compare the method of mechanical CPR and manual CPR is to maximizing on-scene treatment time, and minimizing the hand-off time in cardiac arrest, transporting patient as fast as possible. The electronic data research (Science, Pubmed, Medline, Medline and 55 academic DB interworking) was conducted, and five articles were included by reviewing and excluding through the Covidence program and Review Manager version 5.4(Cochrane Collaboration). OHCA occurring on the higher floor indicates lower in survival. A total studies uniformly reported mechanical CPR is more effective during the high-rise building evacuation, than manual CPR in rate, depth, and hands-on time of chest compression. Use of mechanical CPR device is more suitable in case of High-rise building OHCA to improve the survival rate which is affected by high-quality CPR.

화재 진압용 스프링클러 헤드 유형에 따른 살수 균일도 분석 (Analysis of Water Flux Uniformity for Various Fire Sprinkler Head Type)

  • 방새미;안찬섭;김태훈
    • 한국분무공학회지
    • /
    • 제28권2호
    • /
    • pp.97-104
    • /
    • 2023
  • A sprinkler is a fire suppression system that extinguishes combustible materials in the early stages of a fire, creating a spray. However, spray formation method of the sprinkler can result in an uneven distribution of water spray on the surface of combustible materials. It is necessary to ensure a consistent water flux density regardless of the spray direction and angle. In this study, the water flux distribution was analyzed for the various types of sprinkler head: circular, flush, pendent, and upright types. All sprinkler heads have a K-factor of 80 LPM/(0.1MPa)0.5. In this study, water collection cubes were used to examine the water flux distribution. The upright type sprinkler head showed a low standard deviation in total sprayed area, indicating a high level of uniformity. The upright type head showed the lowest standard deviation in the radial direction, and also showed the lowest standard deviation in the azimuthal direction. Upright sprinkler head has no obstructing structure along the path of droplets after they are generated. For this reason, upright sprinkler head showed the most uniform water flux distribution on the floor.

노후 학교건물의 개축 타당성 평가를 위한 경제성 분석 모델 개발 (Development of Economic Analysis Model for Rebuilding Feasibility Evaluation of Old School Building)

  • 이창수;안희재;권우빈;김민주;김하림;조훈희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.273-274
    • /
    • 2023
  • Although there are many old school buildings that is more than 40 years in Korea, it is difficult to rebuild all of them due to limitations in budget management. Therefore, objective feasibility evaluation criteria are necessary to determine which school buildings should be rebuilt preferentially among the numerous old school buildings. One of the rebuilding feasibility evaluation items, economic evaluation generally requires documents such as construction statements and facility drawings. However, because most buildings older than 40 years do not have these documents, an economic analysis model that requires only basic building information should be developed. In this study, the economic analysis model that can be used for evaluating the rebuilding feasibility only with the number of years, total floor area, and structural information of school buildings was established. This model can contribute to the objective feasibility evaluation of old school buildings because it can evaluate numerous buildings on the same criteria based on basic building information.

  • PDF

국내 건축물 지진피해 위험도의 지역단위 평가 (Regional Seismic Risk Assessment for Structural Damage to Buildings in Korea)

  • 안숙진;박지훈;김혜원
    • 한국지진공학회논문집
    • /
    • 제27권6호
    • /
    • pp.265-273
    • /
    • 2023
  • This study proposes a methodology for the regional seismic risk assessment of structural damage to buildings in Korea based on evaluating individual buildings, considering inconsistency between the administrative district border and grid lines to define seismic hazard. The accuracy of seismic hazards was enhanced by subdividing the current 2km-sized grids into ones with a smaller size. Considering the enhancement of the Korean seismic design code in 2005, existing seismic fragility functions for seismically designed buildings are revised by modifying the capacity spectrum according to the changes in seismic design load. A seismic risk index in building damage is defined using the total damaged floor area considering building size differences. The proposed seismic risk index was calculated for buildings in 29 administrative districts in 'A' city in Korea to validate the proposed assessment algorithm and risk index. In the validation procedure, sensitivity analysis was performed on the grid size, quantitative building damage measure, and seismic fragility function update.

다도해해상국립공원 내 섬 지역의 빛공해 유발 요인 분석 (Analysis of Factors That Cause Light Pollution in Islands in Dadohaehaesang National Park)

  • 성찬용
    • 한국환경생태학회지
    • /
    • 제36권4호
    • /
    • pp.433-441
    • /
    • 2022
  • 빛공해는 연안 및 섬 지역의 생태계를 교란하는 요인 중 하나이다. 본 연구는 야간 위성영상을 이용하여 다도해해상국립공원 내 섬 지역의 빛공해를 일으키는 요인을 분석하였다. 분석은 다도해해상국립공원 내 섬 중 면적이 10만m2 이상인 101개 섬을 대상으로 하였다. 연구 대상 섬의 빛공해 수준은 2019년 1월과 4월, 8월, 10월 DNB monthly 영상에 기록된 야간 빛방사량으로 측정하였다. 연구 대상 섬의 야간 빛방사량을 다도해해상국립공원의 7개 지구별로 비교하면, 금오도지구가 17,666nW/m2/sr로 가장 높았고, 거문도·백도지구, 나로도지구, 소안도·청산도지구가 뒤를 이었다. 계절별로는 10월의 야간 빛방사량이 9,509nW/m2/sr로 가장 높았고, 다음으로 8월, 1월, 4월 순이었다. 연구 대상 섬의 빛공해 수준에 영향을 미치는 요인을 회귀분석을 통해 분석한 결과, 섬에서 반경 5km 내 지역의 건축물 연면적과 등대 개소수는 모든 시기에서 야간 빛방사량에 통계적으로 유의미하게 영향을 미쳤지만, 섬 내부의 건축물 연면적과 등대 개소수는 대부분 시기에 영향을 미치지 않아, 개발이 제한된 국립공원 내 섬 지역에서는 공원 내부보다 인근 지역의 인공조명의 영향이 큰 것을 알 수 있었다. 단, 8월에는 예외적으로 섬 내부의 건축물 연면적이 섬의 야간 빛방사량에 유의미한 영향을 미쳤는데, 이는 휴가철 탐방객이 사용하는 인공조명의 영향으로 보인다. 섬의 크기는 섬의 빛공해 수준에 음(-)의 영향을 미쳤는데, 이는 빛공해가 일종의 생태적 경계효과임을 보여주는 결과이다. 즉, 작은 섬일수록, 섬 전체 면적 중 인접 지역에서 방사된 빛의 영향을 받는 경계 지역의 면적이 상대적으로 넓기 때문이다. 본 연구의 결과는 해상형 국립공원 내 섬 지역의 빛공해 저감을 위해서는, 섬 인근 지역의 인공조명 관리가 필요하다는 것을 시사한다.

산화가 초본층의 발샐 및 토양의 화학적 특성에 미친 영향 (Effects of Forest Eire on Herb Layer Development and Chemical Properties of Soil)

  • 박관수;이미정;송호경
    • 한국환경생태학회지
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2002
  • 본 연구는 산화가 초본층의 발생 및 토양의 화학적 특성에 미친 영향을 조사하기 위해 2000년 4월 대전의 계족산에서 발생한 산화지를 대상으로 실시되었다. 식생조사는 곰솔우점림 (침엽수림)과 아까시나무우점림(활엽수림)에서 10m$\times$10m의 방형구를 설치하여 실시하였고, 초본층의 발생조사는 7월 21일 Dierssen의 우점도법을 적용하여 실시되었다. 초본층의 피도는 침\ulcorner활엽수지역 모두에서 산화지가 비산화지보다 높았으며, 출현종수는 산화지와 비산화지의 차이보다 침\ulcorner활엽수 간에 차이가 더 높았다 토양 시료는 비산화지, 그리고 산화지에서 산화 3일 후 그리고 산화 8개월 후에 0~10cm와 10~20cm 토양깊이에서 채취되었다. 토양 유기물층은 비산화지에서는 깊이가 약 1.5cm이었으나 산화지에서는 유기물층이 없었다. 산화 발생 3일 후 산화지와 비산화지 간의 토양 유기물, 전질소, 유기인산, 치환성 양이온함량, pH및 CEC는 유의적인 차이가 없는 것으로 나타났다. 또한 산화지에서 산화 3일 후와 약 8개월 후의 토양의 화학적 특성들은 일부를 제외하고는 유의적인 차이가 없었다.

건축물의 구조유형을 고려한 해체공사 제도 개선 방안 필요성 - 해체공사의 허가 및 신고를 기준으로 - (Necessity of Improvements on Code of Practice at the Demolition Work considering Building Structure Type : Based on Demolition work of Permission and Registration)

  • 심유경;정재욱;이재현;정재민
    • 한국건설관리학회논문집
    • /
    • 제21권6호
    • /
    • pp.66-74
    • /
    • 2020
  • 해체공사의 수요증가와 사고 위험성을 고려하여 정부는 20년 건축물관리법을 시행해 해체공사의 안전관리를 개선하고자 하였다. 그러나 건축물관리법 제 30조 건축물의 해체 허가에 따른 기준은 일률적이기 때문에 규모에 따른 허가대상 건축물의 구분은 불합리할 수 있다. 또한, 해체공사는 건축물의 구조 유형에 따라 공사 난이도 및 발생 재해의 형태가 달라질 수 있기 때문에 본 연구는 건축물관리법상 신고대상에 속하는 조적조 등의 소규모 건축물의 구조 유형을 고려한 해체공사 안전관리 개선 방안을 제시하고자 한다. 본 연구의 순서는 (I) 건축물관리법 기준; (II) 건축물의 구조 유형에 따른 해체공사 분석; (III) 해체공사 허가대상 세분화 순으로 진행되었다. 연구 결과 건축물관리법상 허가대상은 과거 해체공사 실적의 10% 정도, 조적조는 2.43%에 불과하였다. 허가대상 기준을 세분화한 결과 조적조의 경우 연면적 100㎡이하일 때 허가 및 신고대상의 수가 유사해짐을 확인하였다. 이를 통해 이해관계자는 1) 해외와 같이 규모에 관계없이 특수구조 건축물에 강화된 안전관리 기준을 적용하거나, 2) 건축물의 구조 유형에 따라 해체공사 허가 대상 기준을 세분화하는 방식 등을 활용한 해체공사 안전관리를 개선할 수 있다.

단선 일방통행 방식의 지하철과 주택가격의 관계 분석 - 서울 지하철 6호선 응암순환선 구간 주변 연립다세대를 중심으로 - (A Study on the Relation between the Single-track Subway and Housing Price - Focused on Row and Multi-family House around Eungam Loop Line of Seoul Subway Line 6 -)

  • 소성규;오세준;이규태
    • 지적과 국토정보
    • /
    • 제49권2호
    • /
    • pp.39-56
    • /
    • 2019
  • 단선 일방통행 방식을 지하철 노선으로 도입한 사례는 국외에도 흔치 않은 사례이다. 국내에서는 서울 지하철 6호선의 응암순환선이 대표적인 단선 일방통행 방식의 구간이다. 본 연구는 이러한 응암순환선과 연립다세대 매매가격의 관계를 역과의 인접성 및 특징에 따른 효과를 규명하고자 하였다. 본 연구에서는 2006년부터 2017년까지의 총 17,938건의 연립다세대 매매가격의 자료를 활용하여 헤도닉가격모형을 이용한 분석을 진행하였다. 주요 분석의 결과는 다음과 같다. 첫째, 응암순환선특성으로 지하철역과의 인접성이 매매가격에 중요한 영향을 미친다는 것을 확인할 수 있었다. 거리구간별로는 100-200m 구간의 가격수준이 가장 높았고, 노선의 구조적 특징과 관련해서는 주요 지역으로의 이동성과 연결성이 우수한 불광역을 보행권으로 하는 연립다세대의 매매가격이 높게 나타났다. 둘째, 입지특성으로 버스정류장, 마트, 학교와 인접할수록 매매가격에 긍정적 효과를 미치는 것으로 분석되었다. 셋째, 연립다세대의 토지특성으로 토지면적은 작을수록 매매가격이 높았고, 토지의 세부적 특성인 형상과 방위, 도로접면에 따라서 매매가격에 미치는 유의적인 차이를 확인하였다. 넷째, 건물 및 소재층특성과 관련하여 주택유형과 건물규모, 경과연수, 승강기유무, 소재층에 따라 매매가격에 미치는 영향의 정도가 다른 것으로 분석되었다. 본 연구는 지하철역과의 인접성 및 특징에 따라 연립다세대의 가격에 미치는 효과가 상이하다는 것을 보여줌으로써 비아파트 수요변화에 대응한 주택가격 분석을 위한 참고자료로 활용되고자 한다.