• 제목/요약/키워드: Total Floor Area

검색결과 247건 처리시간 0.026초

지역문화시설의 유니버설 디자인 적용성 평가연구 - 공연전시영역의 공공서비스 공간을 중심으로 - (A Study on Application of Universal Design Principles to Cultural Centers in Local Areas - Focused on Public Service Areas -)

  • 오찬옥
    • 한국실내디자인학회논문집
    • /
    • 제19권2호
    • /
    • pp.3-14
    • /
    • 2010
  • As the seniors and the disabled has increased, the demand for cultural centers has also increased in many local areas. This means that the local cultural centers designed from the viewpoint of universal design are needed, so that to be used by everyone without any difficulties. This study examined the applicability of universal design principles to the public service areas of the local cultural centers. The subject cultural centers were three local ones which had seating capacity of more than 1,000 and opened after the year of 2,000 in Gyungnam. The spatial scopes of the study were six public service areas of the local cultural centers : entrance area, corridor and pathway, stair, ramp, elevator, and rest room. The total 65 items for evaluating the applicability of universal design were selected and examined for six areas. On the whole, accessibility, such as wide pathway and flat floor was good. However, the following improvements were needed. 1) Handrails and rounded corner were needed on walls. 2) Consideration of the visually impaired like as braille sign was needed. 3) The handrails on ramp should be installed for usability. 4) The automatic door would be more useful to the physically disabled users. 5) Wider space and familiar handrail design and color were needed in the rest rooms for the handicapped.

Effects of infill walls on RC buildings under time history loading using genetic programming and neuro-fuzzy

  • Kose, M. Metin;Kayadelen, Cafer
    • Structural Engineering and Mechanics
    • /
    • 제47권3호
    • /
    • pp.401-419
    • /
    • 2013
  • In this study, the efficiency of adaptive neuro-fuzzy inference system (ANFIS) and genetic expression programming (GEP) in predicting the effects of infill walls on base reactions and roof drift of reinforced concrete frames were investigated. Current standards generally consider weight and fundamental period of structures in predicting base reactions and roof drift of structures by neglecting numbers of floors, bays, shear walls and infilled bays. Number of stories, number of bays in x and y directions, ratio of shear wall areas to the floor area, ratio of bays with infilled walls to total number bays and existence of open story were selected as parameters in GEP and ANFIS modeling. GEP and ANFIS have been widely used as alternative approaches to model complex systems. The effects of these parameters on base reactions and roof drift of RC frames were studied using 3D finite element method on 216 building models. Results obtained from 3D FEM models were used to in training and testing ANFIS and GEP models. In ANFIS and GEP models, number of floors, number of bays, ratio of shear walls and ratio of infilled bays were selected as input parameters, and base reactions and roof drifts were selected as output parameters. Results showed that the ANFIS and GEP models are capable of accurately predicting the base reactions and roof drifts of RC frames used in the training and testing phase of the study. The GEP model results better prediction compared to ANFIS model.

다산 어린이 공원설계 (Design of the Dasan Children's Park)

  • 김성균
    • 한국조경학회지
    • /
    • 제29권5호
    • /
    • pp.51-59
    • /
    • 2001
  • This paper presents a design of the Dasan Children\`s Park which is located Shindang- dong, lung-gu, Seoul which has an area of about 3,678$m^2$. Objectives for the design were to make nature-friendly space, learning space, interesting play space, space for every child, adventure play space, traditional play space, sense of place, and recycle space. For the space compositions a children\`s garden, a traditional play space, and a science play space were located around the S shaped main route. Facilities relating nature, science, culture. environment and adventure play were arranged in the 3 main spaces. The Children\`s Garden is a green space for learning and playing with natural elements. It is composed of a ecological learning space, a children\`s story garden, a children\`s song road, an environmental labyrinth, and a pall space leer handicap children. The Science Play Place is a place space for learning scientific theories through plays to which scientific theories were applied. It is composed of a total play structure, a math experience playground, a \"Keojunggi\" play space, a sound reflecting experience space, arid an infant playground. The Traditional Play Madang(space) is a space for traditional plays. It is composed of a traditional play pattern, a sun dial, and a floor fountain. The Recycle Road is a dragon shaped road fort learning about resource recycling and conservation. It is composed of a dragon head, body, tail space and a dragon bead(cint mani).int mani).

  • PDF

Numerical assessment of post-tensioned slab-edge column connection systems with and without shear cap

  • Janghorban, Farshad;Hoseini, Abdollah
    • Computers and Concrete
    • /
    • 제22권1호
    • /
    • pp.71-81
    • /
    • 2018
  • Introduction of prestressed concrete slabs based on post-tensioned (PT) method aids in constructing larger spans, more useful floor height, and reduces the total weight of the building. In the present paper, for the first time, simulation of 32 two-way PT slab-edge column connections is performed and verified by some existing experimental results which show good consistency. Finite element method is used to assess the performance of bonded and unbonded slab-column connections and the impact of different parameters on these connections. Parameters such as strand bonding conditions, presence or absence of a shear cap in the area of slab-column connection and the changes of concrete compressive strength are implied in the modeling. The results indicate that the addition of a shear cap increases the flexural capacity, further increases the shear strength and converts the failure mode of connections from shear rigidity to flexural ductility. Besides, the reduction of concrete compressive strength decreases the flexural capacity, further reduces the shear strength of connections and converts the failure mode of connections from flexural ductility to shear rigidity. Comparing the effect of high concrete compressive strengths versus the addition of a shear cap, shows that the latter increases the shear capacity more significantly.

Analysis of seismic mid-column pounding between low rise buildings with unequal heights

  • Jiang, Shan;Zhai, Changhai;Zhang, Chunwei;Ning, Ning
    • Earthquakes and Structures
    • /
    • 제15권4호
    • /
    • pp.395-402
    • /
    • 2018
  • Floor location of adjacent buildings may be different in terms of height elevation, and thus, the slab may hit on the columns of adjacent insufficiently separated buildings during severe ground motions. Such impacts, often referred to as mid-column pounding, can be catastrophic. Substantial pounding damage or even total collapse of structures was often observed in large amount of adjacent low rise buildings. The research on the mid-column pounding between low rise buildings is in urgency need. In present study, the responses of two adjacent low rise buildings with unequal heights and different dynamic properties have been analyzed. Parametric studies have also been conducted to assess the influence of story height difference, gap distance and input direction of ground motion on the effect of structural pounding response. Another emphasis of this study is to analyze the near-fault effect, which is important for the structures located in the near-fault area. The analysis results show that collisions exhibit significant influence on the local shear force response of the column suffering impact. Because of asymmetric configuration of systems, the structural seismic behavior is distinct by varying the incident directions of the ground motions. Results also show that near-fault earthquakes induced ground motions can cause more significant effect on the pounding responses.

사무소건물 조명기기와 열원기기의 고효율기기로의 교체에 관한 경제성 검토 (Feasibility Study on Retrofitting Lighting and Heat Source Equipments in Office Buildings)

  • 이철구;김종대;임태순
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권2호
    • /
    • pp.13-18
    • /
    • 2016
  • Energy saving has been main concern, thus government supporting policies which are based on Fundamentals of Low-carbon Green Growth Act', 'Green Building Support Act, have been prepared in Korea. The objective of this study is to estimate energy conservation effectiveness and economic advantage assuming that lighting equipments and heat source equipments would be retrofitted. Office building, which has total floor area of $30,000m^2$, was a subject of this study. From the estimations, electric rate will be decreased by 62,886,000 won per year due to lighting equipments retrofit, and gas rate will be decreased 11,141,000 won or 17,332,000 won per year due to heat source equipments retrofit (in case of COP 1.2 or 1.5). Payback period of each case that are calculated by energy saving cost and retrofit cost are estimated 27.9 year, 38.6 year and 29.2 year, thus economic supporting policies is necessary for effective energy saving in buildings. Meanwhile payback period of heat source equipment for new building is estimated 6.1 year and 8.3 year.

수평형 지열 히트펌프 시스템의 냉난방 성능 분석 (Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger)

  • 손병후
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.230-239
    • /
    • 2012
  • Ground-coupled heat pump (GCHP) systems utilize the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. The main objective of the present study is to investigate the cooling and heating performance of a small scale GCHP system with horizontal ground heat exchanger (HGHE). In order to evaluate the performance, a water-to-air ground-source heat pump unit connected to a test room with a net floor area of 18.4 m2 and a volume of 64.4 m3 in the Korea Institute of Construction Technology ($37^{\circ}39'N$, $126^{\circ}48'E$) was designed and constructed. This GCHP system mainly consisted of slinky-type HGHE with a total length of 400 m, indoor heat pump, and measuring devices. The peak cooling and heating loads of the test room were 5.07 kW and 4.12 kW, respectively. The experimental results were obtained from March 15, 2011 to August 31, 2011 and the performance coefficients of the system were determined from the measured data. The overall seasonal performance factor (SPF) for cooling was 3.31 while the system delivered heating at a daily average performance coefficients of 2.82.

1 kW 급 가정용 연료전지 코제너레이션 시스템이 설치된 주택 내 플러그인 하이브리드 자동차의 스마트 충전전략 연구 (A Study on the Strategy of Smart Charging System to Charge the PHEV in the House Which has a 1 kW Fuel Cell Cogeneration System)

  • 노철우;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.838-843
    • /
    • 2008
  • Cause of struggling to escape from dependency of fossil fuels, the fuel cell and the Plug-in Hybrid Electric Vehicle (PHEV) draw attention in the all of the world. Especially, the Polymer Electrolyte Membrane Fuel Cell (PEMFC) systems have been anticipated for next generation's energy supplying system, and we can predict the PHEV will enlarge the market share in the next few years to reduce not only the air pollution in the metropolis but the fuel-expenses of commuters. This paper presents simulation results about the strategy of smart charging system for PHEV in the residential house which has 1 kW PEMFC cogeneration system. The smart charging system has a function of recommending the best time to charge the battery of PHEV by the lowest energy cost. The simulated energy cost for charging the battery based on the electricity demand data pattern in the house. The house which floor area is $132\;m^2$ (40 pyeong.). In these conditions, the annual gasoline, electricity, and total energy cost to fuel the PHEV versus Conventional Vehicle (CV) have been simulated in terms of cars' average life span in Korea.

  • PDF

상주시 신도심의 복합건축물 실태조사를 통한 계획방향에 관한 연구 (A Study on the planning approach through the Actual Research of Complex Buildings in the New Town of Sangju)

  • 이근택;정용호
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.85-93
    • /
    • 2004
  • This study does try to proceed on the assumption that complex buildings can vitalize urban life of contemporary society from contemporary complexity and cases of past failure. The scope of investigation on complex buildings in Sangju built in 1990s' and 2000s' on this thesis is that site size is 400 square meter, total area 1500 square meter, and the number of stories on the ground below 5 floor. Method of investigation on twenty one buildings which have been built on new C.B.D. between the Namwon avenue and the Joongang 1th street in Sangju is through field investigation, field photographs, recordings and drawings on these buildings. Investigative contents have been divided and analysized into physical and functional elements in urban and architectural dimension. On the basis of these results, the future planning approach of complex buildings in medium and small cities has been considered into planning principles of convenience of building use and efficiency of site size, physical plans reflected on the traffic and pedestrian movings and the face of buildings, pedestrian resting space-creation like plazas and central gardens, regional character reflected with urban context, and separation and union of approached movings interrelated among the components.

주거점유상태와 주택형태에 따른 기혼자의 주거 만족도 (Residential Satisfaction of Married Families by the Type of Housing Tenure and Housing)

  • 이채성
    • 한국주거학회논문집
    • /
    • 제23권1호
    • /
    • pp.9-17
    • /
    • 2012
  • The purpose of this study is to understand the factors that influence residents' satisfaction with their housing. Resident's satisfaction is mainly influenced by two factors - one that pertains to housing and the other as per characteristics of the individual. Housing-related factors include housing types, housing tenure types, and size of floor space. Individual-related factors include household income, size, and education level. This study shows how both factors influence residents' satisfaction. Residential satisfaction is affected by the type of housing tenure (own, chonsei and monthly rent) and housing (detached housing, apartment and multi-family housing). Residential satisfaction of home owners is greater than that of chonsei renters or monthly renters. Residential satisfaction of chonsei renters is greater than that of monthly renters. Satisfaction of apartment residents is far greater than that of detached housing residents or multi-family housing residents. There is no difference in residential satisfaction between detached housing and multi-family housing residents. As total household labor income, household member, and residential area increase, residential satisfaction increase. Residential satisfaction of countryside residents is greater than that of metropolitan residents.