• 제목/요약/키워드: Total Efficiency

검색결과 5,597건 처리시간 0.031초

슬러지 탄소원을 주입한 UNR공정의 동절기 질소, 인 처리효율 (The Nitrogen and Phosphorus Removal of UNR Process Using Sludge Carbon Source)

  • 김영규;김인배
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.93-97
    • /
    • 2002
  • The aim of this study was to evaluate on the removal effect of total nitrogen and phosphorus with municipal wastewater in ultrasonic nutrient removal (UNR) process using ultrasonic sludge carbon source. The removal efficiency for total nitrogen was 44.2% at biological nutrient removal (BNR) process, 50.8% at UNR process. The removal efficiency for total phosphorus was 45.6% at BNR process, 46.2% at UNR process. The removal of nitrogen was effectively influenced by ultrasonic sludge carbon source.

재무분석을 통한 한방병원의 경영성과 분석 - 재무비율 및 투자효율을 중심으로 (An Analysis of the Financial Performance of Korean Medicine Hospitals in Korea: Focusing on Financial Ratios and Investment Efficiency)

  • 최원영;임병묵
    • 대한한의학회지
    • /
    • 제41권1호
    • /
    • pp.1-10
    • /
    • 2020
  • Objectives: This study investigated the financial performance of Korean Medicine hospitals in Korea in order to understand the current status of hospital management and improve its efficiency. Methods: Financial statements of 24 medical corporations, 19 juridical foundations and 18 school hospitals from 2016 to 2018 were obtained from the secondary data published by the Health Insurance Review and Assessment Service, the National Tax Service and the Korea Advancing Schools Foundation. Financial performance was measured on 6 dimensions: liquidity, profitability, activity, growth, cost and productivity (investment efficiency) by analyzing 8 financial indicators: Liability to Total Assets, Net Profit to Patient Service Revenues, Total Assets Turnover, Growth Rate of Patient Service Revenues, Operating Expenses to Patient Service Revenues, Value Added to Patient Service Revenues, Value Added to Total Assets, and Value Added to Personnel Expenses. Results: Korean Medicine hospitals showed lower Liability to Total Assets, Liquidity and Value Added to Total Assets than Western Medicine hospitals did. They also showed higher Value Added to Patient Service Revenues and Value Added to Personnel Expenses than Western Medicine hospitals did. They also showed higher Value Added to Patient Service Revenues and Value Added to Personnel Expenses than those of Western Medicine hospitals do. The net profit decreased significantly (-50.8%) in 2018 whereas Patient Service Revenues increased (6.9%) for the same period due to Operating Expenses increase and Non-Operating loss. Conclusions: These findings suggest that the Korean Medicine hospital sector in Korea needs to improve liquidity and financial structure and to enhance profitability by reducing Personnel Expenses and generating Non-operating revenues in order to improve its investment efficiency and competitiveness.

DEA를 이용한 공공도서관의 효율성 평가: 정보서비스 활동을 중심으로 (Efficiency in the Provision of Library Services Using Data Envelopment Analysis)

  • 김선애
    • 한국문헌정보학회지
    • /
    • 제39권1호
    • /
    • pp.221-239
    • /
    • 2005
  • 본 연구는 서울 지역에 소재하고 있는 21개 공공도서관을 대상으로 DEA방법론을 사용하여 정보서비스 활동의 효율적 운영에 초점을 맞춰 상대적 효율성을 평가하였다. 정보서비스 활동의 평가를 위해 필요한 데이터는 2002년 관측치를 사용하였으며, 투입요소로는 장서수, 연속간행물수 그리고 연간증가책수가 사용되었으며, 산출물로는 총 이용책수와 이용자수가 사용되었다. 그 결과 공공도서관의 평균효율성은 $71\%$에서 결정되었으며, 이는 모든 도서관이 효율적인 도서관이 되기 위해서는 현재 수준의 산출물 생산을 기준으로 현재 투입물의 $29\%$를 감축해야 한다는 것을 의미한다. 그리고 비효율적인 도서관은 산출물의 과소생산보다는 투입물의 과다사용에 비효율의 원인이 있는 것으로 나타났으며, 특히 장서수의 운영이 가장 비효율적인 요소로 평가되었다. DEA방법론에 의한 평가 결과는 투입요소와 산출물의 수 또는 정의가 달라지면 다른 결과를 보여줄 수 있으므로 절대적인 것은 아니다.

LC 병렬공진을 이용한 고효율 장수명 LED 구동회로 설계 (The Design of Long-life and High-efficiency Passive LED Drivers using LC Parallel Resonance)

  • 이은수;최보환;천준필;김봉철;임춘택
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.397-402
    • /
    • 2013
  • This paper proposes a new passive type LED driver which satisfies the standard of power factor (PF) and total harmonic distortion (THD). The proposed passive LED driver also has high-efficiency and long-life time characteristics compared to active LED driver which is composed of op-amp, switches and so on. By using just passive components such as inductor, capacitor, and diode, it has resolved extremely short-life time and low-efficiency problems of previous LED drivers. It has achieved PF of 0.99, THD of 16.4 %, and the total efficiency of 95 %. The proposed passive LED driver is fully analyzed and verified by simulations and experiments, which results are in good agreement each other.

축류 회전차 익말단 틈새유동에 대한 수치해석 (III) - 회전차 익말단의 누설손실과 효율저하에 대한 평가 - (Numerical Analysis on the Blade Tip Clearance Flow in the Axial Rotor (III) - Evaluation of Tip Leakage Loss and Reduction of Efficiency near Blade Tip Clearance Region of a Rotor -)

  • 노수혁;조강래
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1113-1120
    • /
    • 1999
  • Leakage vortices fonned near the blade tip cause an increase of total pressure loss near the casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flow fields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and the of attack on the leakage vortex and overall performance, and the los9 distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss due to the tip clearance were evaluated using numerical results and approximate equations were presented to evaluate the reduction of rotor efficiency due to the tip leakage flow.

물 부족국가에서 활용가능한 정화조의 최적모형 개발 (Development of Optimal Septic Tank in the Countries of Water Shortages)

  • 임봉수;경해룡
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

운전조건에 따른 전열교환기의 성능특성 연구 (A Study on the Characteristics of Total Heat Exchanger under Various Conditions)

  • 배철호;임영헌;드래바굴노라;박지열;곽경민;주의성;김영생;김지용
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.891-897
    • /
    • 2005
  • The characteristics of energy Performance for total heat exchanger have been investigated under various conditions. In cooling operation the latent and enthalpy efficiency are affected by the difference of absolute humidity ratio between indoor and outdoor air. In addition to this the characteristics of absorbing material in the element affects the energy performance. Low dry bulb temperature of indoor air or high absolute humidity ratio in outdoor air give high latent and enthalpy efficiency even with the same temperature difference of dry bulb temperate between indoor and outdoor air.

방진마스크의 에어졸 방어효과와 밀착정도 (Protection against Aerosols by particulate Respirators and Fit Performance)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

약제비 제외가 의원의 진료비 효율성 순위에 영향을 미치는가? (Does Omission of Pharmacy Cost Affect Cost-Efficiency Rankings in Medical Clinics?)

  • 강희정;홍재석
    • 보건행정학회지
    • /
    • 제20권4호
    • /
    • pp.45-57
    • /
    • 2010
  • Background : If different cost efficiency indexes were informed to the same clinic depending on the inclusion or exclusion of pharmacy cost, it may impair the reliability of provider-profiling system. This study aimed to investigate whether the omission of pharmacy cost affects cost-efficiency rankings in medical clinics. Methods : Data for ambulatory care cost at 23,112 medical clinics were collected from the claims database, which was constructed after review by the Health Insurance Review and Assessment Service (HIRA) of Korea in April 2007. We calculated two types of cost efficiency indexes by inclusion or exclusion of pharmacy cost for a medical clinic. The agreement between the decile rankings of the two indexes was also assessed using the weighted kappa statistic of Landis and Koch. Results : When the cost efficiency index for total cost including pharmacy cost was compared with the index for total cost excluding it, the agreement between the two indexes was only 55%. The agreements between the two indexes were relatively low within specialties which have larger pharmacy volume of total cost and lower correlation between total cost with or without pharmacy cost included than the average level of all the specialties. Conclusion : These results suggest that the omission of pharmacy cost may result in contradictory outcomes that may be confusing to a medical institution and may impair the reliability of provider-profiling systems. It is very important to standardize profiling criteria for the reliability of provider profiling system.

5축 복합가공기의 에너지 저감을 위한 기술 및 적용 방안 (Design Approaches and Strategies for Energy Saving of 5-Axis Multi-Functional Machine Tools)

  • 김태성;김경동;이찬홍;남성호
    • 한국정밀공학회지
    • /
    • 제30권5호
    • /
    • pp.467-473
    • /
    • 2013
  • Diverse approaches for reducing the total energy consumption of machine tools have been introduced and developed, to cope with rapid increase of total energy costs in world-wide manufacturing industries. To realize the improvement of the energy efficiency, systematic and integrated strategies must be considered, including energy-saving design, optimized control operation and concrete evaluation of the energy efficiency. This paper proposes key enabling technologies required to improve the energy efficiency of 5-axis multi-functional machining tools, considering both of system design and operation in the real production environments. Related standardized procedures of the energy efficiency evaluation is also represented.