• Title/Summary/Keyword: Torque-Angle Relationship

Search Result 36, Processing Time 0.024 seconds

A Study on the Amount of Mandibular Rotation and Pattern of Condylar Path (하악운동 회전량과 과로의 형태에 관한 연구)

  • Kyung-Soo Han;You-Me Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.369-382
    • /
    • 1996
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronicⓡ and mandibular rotational torque movements with BioEGNⓡ. For this study 56 patients with Temporomandibular disorders(TMD) and 30 dental students without any masticatory signs and symptoms were selected as patients group and control group, respectively. The items recorded with Pantronicⓡ(Denar Corp., USA) were immediate side-shift, progressive side-shift, angle of orbiting path, protrusive path and PRI. BioEGNⓡ(Bioelectric gnathography, Bioresearch Inc., USA) were used to measure the amounts of mandibular rotational torque movements in frontal and horizontal plane, and the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement depicted between the condyles was automatically analysed by angle and difference in frontal and horizontal plane. The obtained data were processed with SAS program and the conclusion of this study were as follows : 1. Mean values of items between patients group and control group in Pantronic measurements were not significantly different except in left protrusive path and in Pantronic Reproducibility Index(PRI). There were no significant difference of condylar paths by preferred chewing side and affected side between the two groups. 2. The amount of mandibular rotational torque movements were differed in frontal angle and difference on protrusion, and in frontal and in horizontal difference on left excursion between the two groups. But the amounts of translatory movements were actually same on all eccentric movements. 3. The amount of mandibular rotational torque movements with splint mere almost not changed from those without splint, with the exception of in horizontal measurements on protrusion. 4. The correlations of items between in Pantronic measurements and in BioEGN measurements wert not consistently, significant, however, generally the ISS related significantly with horizontal torque movement positively, and with frontal torque movement negatively on the contrary, the PSS showed positive correlation with frontal torque movement, and negative correlation with horizontal torque movement.

  • PDF

The design of a torque controller for single phase induction motor using phase angle (위상각제어에 의한 단상유도전동기의 토크제어기설계)

  • Lim, Y.C.;Choi, C.H.;Na, S.H.;Jung, Y.G.;Chang, H.C.;Chang, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.908-911
    • /
    • 1993
  • The single-Phase induction motor is widely used in many light duty applications. especially in home and the office. At present, many applications which use these motor require continuously adjustable speed control. In the general, the speed control of single-phase induction motor is accomplished at a few discrete speeds by using tapped-windings, pole switching or gear. These techniques is inefficient and complicated. In this paper, auxiliary winding voltage phase angle of single-phase induction motor is used to continuously adjust electromagnetic torque. The analysis includes the determination of the relationship between the auauxiliary winding voltage phase angle and torque. Simulation results of the motor's torque-speed characteristics using the controlled auxiliary winding supply are shown and discussed. The drive is tested using a dynamometer to experimentally verify the results of the theory and simulations.

  • PDF

Characteristics of EMG Median Frequency and Torque in Relation to Low Back Angle During Isometric Back Extension Exercise (등척성 운동 시 요추의 각도에 따른 중앙주파수와 토크의 특성)

  • Park, Kyoung-Hee;Kwon, Oh-Yun;Jang, Kuen;Kang, Sung-Jae;Kim, Young-Ho
    • Physical Therapy Korea
    • /
    • v.8 no.2
    • /
    • pp.41-54
    • /
    • 2001
  • Fatigue is the decline in force produced as a result of prolonged muscle activity. Localized muscle fatigue can be identified by a shift toward low in the frequency components of the EMG signal, typically represented by a fall in the median frequency. Previous studies show that a shortened muscle develops a higher fatigue than elongated muscles. The purpose of this study was to investigate the time-related change of median frequency and torque during maximal isometric back extension exercises at different exercise angles ($0^{\circ}$, $12^{\circ}$, $36^{\circ}$, $72^{\circ}$). Twenty healthy subjects (mean age = $24.35{\pm}2.70$) were evaluated in this study. Median frequency was extracted from the EMG signals by fast Fourier transform (FFT). Initial median frequency and the slope of median frequency change over time were computed from linear regression analysis. Pearson's product moment correlation was used to quantify the relationship between slope of median frequency and torque. The results were as follows: 1) Significant differences in y-intercepts of torque regression equation with respect to exercise angle were shown. However, there were no differences in the slopes of the median frequency and torque, and y intercept of the median frequency among exercise angles. 2) There was no significant correlation between slope of median frequency and torque. 3) But there was moderate correlation between median frequency and torque at each exercise angle. In conclusion, the exercise angle during maximal isometric back extension exercise is not a direct effect on slope of median frequency and torque. But results showed that median frequency and torque shift were highly correlated in all subjects.

  • PDF

A Study on the Torque Performance to Capacitance of a Capacitor-run type Single Phase Induction Motor

  • Kim Cherl-Jin;Choi Chul-Yong;Baek Soo-Hyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.20-26
    • /
    • 2005
  • Various kinds of practical machines using the single phase induction motor (SPIM) are utilized to control both speed and torque. In particular, the capacitor-run type SPIM has the characteristic that allows the motor torque to be altered by auxiliary capacitance variation. In this study, we manifest an equivalent model having a more simplified configuration, and clarify the relationship between torque and capacitance. Also, we design an experimental controller that is able to perform speed control with ease by the phase angle control of the AC input voltage. Validity of this study is confirmed through the simulation and experimental results obtained.

Identification of Flexion Withdrawal Reflex Using Linear Model in Spinal Cord Injury

  • Kim Yong-Chul;Youm Youn-Gil
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1183-1194
    • /
    • 2006
  • The aim of this study was to identify the characteristics of the flexion withdrawal reflex modulated by the hip angle and hip movement in spinal cord injury (SCI). The influence of the hip position and passive movement were tested in 6 subjects with chronic SCI. Each subject placed in a supine position and lower leg was fixed with the knee at 5 -45 degree flexion and the ankle at 25-40 degree plantar flexion. A train of 10 stimulus pulses were applied at 200 Hz to the skin of the medial arch to trigger flexion reflexes. From results of the regression analysis, static properties of normalized muscle activation of flexor muscles have the linear relationship with respect to hip angle (P< 0.05). In order to verify the neural contribution of flexion reflex, we compared the static and dynamic gains of estimated muscle activations with measured EMG of ankle flexor muscle. Form this study, we postulate that the torque and muscle response of flexion withdrawal reflex have linear relationship with hip angle and angular velocity.

A Robust Indirect Vector Control of Induction Motor with On-Line Tuning of Rotor Time Constant in Wide Speed Range (전운전영역에서 회전자 시정수 온라인 동조에 의한 강인한 벡터제어)

  • 조순봉
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.201-208
    • /
    • 1999
  • This paper presents the degradation of the system performance according to the vmiation of the rotor time constant. The algorithm for the on-line estimation of rotor time constant is proposed. which is applied to the consistent relationship between the tangent torque angle of the synchronous reference frame and that of stationary reference f frame. For the purpose of the validity of proposed algorithm. the computer simulation and the experiments have been p performed.

  • PDF

Nonlinear finite element analysis of torsional R/C hybrid deep T-beam with opening

  • Lisantono, Ade
    • Computers and Concrete
    • /
    • v.11 no.5
    • /
    • pp.399-410
    • /
    • 2013
  • A nonlinear finite element analysis of R/C hybrid deep T-beam with web opening subjected to pure torsion is presented. Hexahedral 8-nodes and space truss element were used for modeling concrete and reinforcement. The reinforcement was assumed perfectly bonded to the corresponding nodes of the concrete element. The constitutive relations for concrete and reinforcement are based on the modified field theory and elastic perfectly plastic. The smear crack approach was adopted for modeling the crack. The torque-twist angle relationship curve based on the finite element analysis was compared to the experimental results. The comparison shows that the curve of torque-twist angle predicted by the nonlinear finite element analysis is linear before cracking and close to the experimental result. After cracking, the curve becomes nonlinear and stiffer compared to the experimental result.

Force Depression Following Active Muscle Shortening during Voluntary Contraction in Human Tibialis Anterior Muscle (인체 전경골근의 수의적 수축시 선행 동심성 근수축이 항정상태 등척성 근력에 미치는 영향)

  • Lee, Hae-Dong;Lee, Seung-Cheol
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.75-83
    • /
    • 2006
  • The purpose of this study was to investigate steady-state force depression following active muscle shortening in human tibialis anterior muscle during voluntary contractions. Subjects (n = 7; age $24{\sim}39$ years; 7 males) performed isometric reference contractions and isometric-shortening-isometric contractions, using maximal voluntary effort. Force depression was assessed by comparing the steady-state isometric torque produced following active muscle shortening with the purely isometric reference torque obtained at the corresponding joint angle. In order to test for effects of the shortening conditions on the steady-state force depression, the speed of shortening were changed systematically in a random order but balanced design. Ankle dorsiflexion torque and joint angle were continuously measured using a dynamometer. During voluntary contractions, muscle activation of the tibialis anterior and the medical gastrocnemius was recorded using surface electromyography. Force depression during voluntary contractions, with a constant level of muscle activation, was 12 %, on average over all subjects. Force depression was independent of the speeds of shortening ($13.8{\pm}2.9%$, $10.3{\pm}2.6%$ for 15 and 45 deg/sec over 15 deg of shortening, respectively). The results of this study suggest that steady-state force depression is a basic property of voluntarily-contracting human skeletal muscle and has functional implication to human movements.

Kinematic Calibration Method for Redundantly Actuated Parallel Mechanisms (여유구동 병렬기구의 기구학적 보정)

  • 정재일;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.355-360
    • /
    • 2002
  • To calibrate a non-redundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism's kinematic structure and measurement values. However, the calibration algorithm for a non-redundant case does not apply fur a redundantly actuated parallel mechanism, because the angle error of the actuating joint varies with position and the geometrical constraint fails to be consistent. Such change of joint angle error comes from constraint torque variation with each kinematic pose (meaning position and orientation). To calibrate a redundant parallel mechanism, one therefore has to consider constraint torque equilibrium and the relationship of constraint torque to torsional deflection, in addition to geometric constraint. In this paper, we develop the calibration algorithm fir a redundantly actuated parallel mechanism using these three relationships, and formulate cost functions for an optimization algorithm. As a case study, we executed the calibration of a 2-DOF parallel mechanism using the developed algorithm. Coordinate values of tool plate were measured using a laser ball bar and the actual kinematic parameters were identified with a new cost function of the optimization algorithm. Experimental results showed that the accuracy of the tool plate improved by 82% after kinematic calibration in a redundant actuation case.

  • PDF

RELATIONSHIP BETWEEN MANDIBULAR MOVEMENTS AT INCISAL AREA AND CONDYLAR MOVEMENTS (전치부 하악운동양태와 과두운동 간의 관계)

  • Kang, Seok-Ku;Han, Kyung-Soo;Jin, Tai-Ho;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.15-29
    • /
    • 1997
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronic and mandibular movements at incisal area recorded with BioEGN. For this study 24 patients with Temporomandibular disorders(TMDs) and 30 dental students without any masticatory symptoms were selected as patients group and control group, respectively. The items recorded with Pantronic(Denar Corp., USA) were immediate side-shift, orbiting path, protrusive path, and PRI. BioEGN(Bioelectric-gnathography, Bioresearch Inc., USA) were sued to measure the amount of mandibular torque movement in frontal and horizontal plane and also the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement was analyzed by angle and difference between both condyles in frontal and horizontal plane. The collected data were processed with SAS program and conclusion were as follows : 1. Mean value of items recorded with Pantronic were not significantly differed between patients group and control group except the item of pantographic reproducibility index(PRI). The value of PRI was 39.5 in patients group, and 29.5 in control group. 2. The amount of mandibular torque movement was not differed tin early protrusive and early left excursion between patients group and control group, but in early right excursion, patients group showed more value than control group did. 3. The distance on sagittal plane in early eccentric movements were longer in patients group than those in control group, but the distance of maximal eccentric movements were not significantly differed between patients group and control group. 4. Items which showed significant correlation with PRI were progressive side-shift, and horizontal torque movement in early protrusion and right excursion. 5. The angle of protrusive path of affected side was greater than of non-affected side in unilaterally affected patients, but the protrusive angle of preferred chewing side was not differed from that of contralateral side in control group. 6. The amount of torque movement in early protrusion and right excursion were greater in patients with coincidence of affected side and preferred chewing side than in patients without coincidence.

  • PDF