• 제목/요약/키워드: Torque controller

검색결과 988건 처리시간 0.026초

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

모멘텀 바이어스 인공위성의 2축 자세제어 시스템 설계 (Two Axis Attitude Control System Design of Momentum Biased Satellite)

  • 이승우;서현호
    • 한국항공우주학회지
    • /
    • 제34권4호
    • /
    • pp.40-46
    • /
    • 2006
  • 위성기술의 비약적 발달에 따라서 설계 및 제작에 소용되는 비용은 저렴하지만 신뢰도가 높은 인공위성 자세제어 시스템 개발이 요구되고 있다. 본 연구는 이러한 요구를 만족시키기 위해 반작용휠에 의한 모멘텀 바이어스 벡터가 임의의 방향(태양 방향)을 지향하고 안정화되는 위성시스템을 제시하였다. 위성 시스템에서 고장 가능성이 가장 적은 자기장 센서, 저정밀 태양센서 및 자기토커를 센서와 구동기로 사용하였으며, 고전적 선형 제어방법에 의해 2축 제어하는 제어시스템 설계방법을 제시하였다. 제어기는 PD 형태의 간단한 제어기가 사용되었고, 선형화된 위성시스템에 대한 PD 제어기 설계방법이 적절한 가정과 함께 제시되었다. 제시된 제어기 설계방법에 의해 설계된 폐루프 시스템의 장기 안정성 검증을 위해서 비선형 시뮬레이션 방법을 사용하였다.

MAP 기반 DME용 엔진 제어로직 개발 (Development of Map-Based Engine Control Logic for DME Fuel)

  • 박용국;정재우
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3127-3134
    • /
    • 2013
  • 본 연구는 DME 연료를 사용할 수 있도록 변경된 엔진의 제어 알고리즘, 로직구성 및 차량상태에서 검증결과를 나타낸 것으로써, 제어구조 및 자동코드 생성기법에 의한 제어로직 설계과정과 제어 맵을 소개하고 최종적으로 제어의 신뢰성 및 성능을 검증한 것이다. 제어구조는 운전자 요구를 엔진발생토크로 구현하기위한 분사제어부와 배기가스 및 동력특성을 만족시키기 위한 공기제어 시스템부로 크게 구성되며, 제어로직은 제어응답성을 향상시키기 위하여 각 제어 기능별로 앞먹임 및 뒤먹임 제어부로 설계되었고, 앞먹임 제어부의 제어 맵은 엔진모델을 이용하여 생성한 뒤, 이를 엔진 및 차량 시험과정에서 보정하였다. 개발된 제어기를 장착하여 차량 시험모드를 완주하였으며, EGR, VGT 및 분사시기 보정에 의하여 배출가스 저감효과를 확인하였다.

QFT를 이용한 전기유압 하이브리드 부하 시뮬레이터의 능동 힘제어 (Active Force Control of Electro-Hydraulic Hybrid Load Simulator using Quantitative Feedback Theory)

  • 윤주현;안경관;딩쾅청;조우근
    • 한국정밀공학회지
    • /
    • 제26권2호
    • /
    • pp.45-53
    • /
    • 2009
  • Today, reduction of $CO_2$ exhaustion gas for global-warming prevention becomes important issues in all industrial fields. Hydraulic systems have been widely used in industrial applications due to high power density and so on. However hydraulic pump is always being operated by engine or electric motor in the conventional hydraulic system. Therefore most of the conventional hydraulic system is not efficient system. Recently, an electro-hydraulic hybrid system, which combines electric and hydraulic technology in a compact unit, can be adapted to a wide variety of force, speed and torque requirements. In the electro-hydraulic hybrid system, hydraulic pump is operated by electric motor only when hydraulic power is needed. Therefore the electro-hydraulic system can reduce the energy consumption drastically when compared to the conventional hydraulic systems. This paper presents a new kind of hydraulic load simulator which is composed of electro-hydraulic hybrid system. Disturbances in the real working condition make the control performance decrease or go bad. QFT controller is designed to eliminate or reduce the disturbance and improve the control performance of the electro-hydraulic load simulator. Experimental results show that the proposed controller is verified to apply for electro-hydraulic hybrid system with varied external disturbances.

4축 전동실린더의 동기제어시스템 설계 (The Synchronous Control System Design for Four Electric Cylinders)

  • 양경욱;변정환
    • 한국전자통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.1209-1218
    • /
    • 2016
  • 4대의 전동실린더를 이용하여 대형 유리판과 같은 부하를 신속하고 안전하게 이송하기 위해서는 동기오차가 허용된 범위 내에서 지속적으로 유지되어야 한다. 본 연구에서는 4대 이상의 전동실린더 간의 동기화에 적용 가능한 동기제어기법이 제안된다. 이 동기제어시스템은 디커플링 구조에 기반을 두고 있으며, 기준모델, 위치제어기 그리고 동기제어기로 구성된다. 기준모델은 각각의 실린더에 대해 상호 분리된 동기오차와 제어입력의 계산이 가능하도록 한다. I-PD형의 위치제어기는 각 실린더가 오버슈트와 입력포화를 일으키지 않고 지령을 추종하도록, 그리고 진상보상기형의 동기제어기는 루프정형을 통해 안정적으로 정밀한 동기가 되도록 설계 된다. 끝으로 토크외란이 인가된 상태에서도 4개의 실린더가 신속하고 안정적으로 동기를 유지하면서 목표지점에 도달됨을 시뮬레이션으로 검증한다.

3상 BLDC 전동기 구동을 위한 4-스위치 인버터의 DC-Link 전압 불평형 보상 (DC-Link Voltage Unbalancing Compensation of Four-Switch Inverter for Three-Phase BLDC Motor Drive)

  • 박상훈;윤용호;이병국;이수원;원충연
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.391-396
    • /
    • 2009
  • In this paper, a control algorithm for DC-Link voltage unbalancing compensation of a four-switch inverter for a three-phase BLDC motor drive is proposed. Compared with a conventional six-switch inverter, the split source of the four-switch inverter can be obtained by splitting DC-link capacitor into two capacitors to drive the three phase BLDC motor. The voltages across each of two capacitors are not always equal in steady state because of the unbalance in the impedance of the DC-link capacitors $C_1$ and $C_2$ or the variable current flowed into the capacitor's neutral point in motor control. Despite the unbalance, if the BLDC motor may be run for a long time the voltage across one of the capacitors is more increased. So the unbalance in the capacitors voltages will be accelerated. As a result, The current ripple and torque ripple is increased due to the fluctuation of input current which flows into 3-phase BLDC motor. According to that, the vibration of motor will be increased and the whole system will be instable. This paper presents a control algorithm for DC-Link voltage unbalancing compensation. The sampling from the voltages across each of two capacitors is used to perform the voltage control of DC-Link by using the feedforward controller.

외란 관측기를 이용한 영구자석 동기전동기의 비선형 속도 제어 (A Nonlinear Speed Control for a Permanent Magnet Synchronous Motor Using a Simple Disturbance Estimation Technique)

  • 이나영;김경화;윤명중
    • 전력전자학회논문지
    • /
    • 제6권2호
    • /
    • pp.149-157
    • /
    • 2001
  • 본 논문에서는 간단한 외란 관측 기법을 이용한 영구자석형 동기 전동기(Permanent Magnet Syncoronous Motor:PMSM)의 비선형 속도 제어 기법이 제안된다. 피드백 선형화(feedback linearization) 기법을 이용함으로써 비선형 요서가 효과적으로 제거되고 출력 오차 동특성을 선형 제어 기법에 기반하여 설정할 수 있다. 그러나 이 방식은 제어기의 파라미터들이 실제 모터의 파라미터들과 일치하지 않으면 만족스러운 성능을 기대할 수 없다. 본 논문에서는 파라미터들이 실제 모터의 파라미터들과 일치하지 않으면 만족스러운 성능을 기대할 수 없다. 본 논문에서는 파라미터 변동에 의한 비선형 외란을 제거하기 위해 외란 관측 기법을 이용한다. 제안한 방식에는 두개의 축소 차수 관측기만 이용되므로 관측기 설계가 상당히 간단하고 파라미터 추정을 위한 제어기의 계산량에 많은 부담을 주지 않는다. 제안한 관측기를 이용한 비선형 속도 제어 알고리즘이 파라미터 변동에 대해 상인한 제어특성을 가짐을 시뮬레이션과 실험 결과로 입증하였다.

  • PDF

MATLAB/SIMULINK와 dSPACE 1104 시스템을 이용한 표면 부착형 영구자석 동기전동기 벡터제어 (Vector Control of SPMSM Using MATLAB/SIMULINK & dSPACE 1104 System)

  • 이용석;지준근
    • 한국산학기술학회논문지
    • /
    • 제9권2호
    • /
    • pp.317-326
    • /
    • 2008
  • 본 논문은 MATLAB/SIMULINK와 dSPACE 1104 시스템을 사용하여 표면부착형 영구자석 동기전동기 벡터제어를 구현하였다. 영구자석 동기전동기는 고정자 전류를 자속발생 전류성분과 토크발생 전류성분으로 분리하고 이를 각각 독립적으로 제어함으로써 타여자 직류전동기처럼 다루는 것이 가능하기 때문에 기존의 직류전동기 제어에 사용되던 각종 제어 알고리즘을 적용하는 것이 가능하게 된다. 본 연구에서는 표면 부착형 영구자석 동기 전동기의 벡터제어를 구현하기 위하여, 먼저 MATLAB/SIMULINK 프로그램으로 영구자석 동기 전동기를 모델링하고 속도제어 부에는 비례-적분 제어기를, 전류제어 부에는 비간섭 비례-적분 제어기를 설계하여 제어기의 응답을 미리 확인하였다. 그리고 설계된 제어기의 성능을 입증하기 위하여 dSPACE DS1104 R&D Board에 시뮬레이션을 통해 구현된 영구자석 동기전동기 벡터 제어 프로그램을 다운로드하여 실험을 통해 제안된 벡터제어 시스템의 타당성을 입증하였다

매입형 영구자석 동기전동기를 적용한 전기기계식 제동장치의 비상제동 성능평가 (A Evaluation of Emergency Braking Performance for Electro Mechanical Brake using Interior Permanent Magnet Synchronous Motor)

  • 백승구;오혁근;박준혁;김석원;김상수
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.170-177
    • /
    • 2020
  • 본 논문은 전기기계식제동장치(EMB : Electro Mechanical Brake, 이하 EMB)의 제동 압부력(clamping force) 제어방법과 제동시험장비(dynamo test equipment)를 활용한 제동성능 평가결과에 대하여 다룬다. EMB와 관련한 연구는 자동차 분야에서 대부분 수행되었으며, 다양한 제어방법에 대한 정적상태의 압부력 시험결과를 주로 다루고 있으나 본 논문은 동적상태에서의 성능평가를 수행하였다. EMB의 구동을 위해 3상 매입형 영구자석 동기전동기(IPMSM : Interior Permanent Magnet Synchronous Motor, 이하 IPMSM)가 적용되었으며 유한요소법(FEM : Finite Element Method, 이하 FEM) 해석 소프트웨어인 JMAG을 통하여 설계 및 해석을 수행하였다. EMB의 압부력제어를 위해 전류제어, 속도제어 및 위치제어가 수행되었으며, 전류제어기는 단위전류당 최대토크제어(MTPA : Maximum Torque Per Ampere, 이하 MTPA)가 적용되었다. 제동성능평가는 공압식 제동장치의 비상제동 성능시험 절차와 동일한 방법으로 수행되었으며 시험장비에 설치된 고속철도차량의 차륜을 110 km/h, 230 km/h 및 300 km/h로 회전하는 상태에서 각각의 속도 조건에 따른 EMB의 제동 압부력을 인가하여 감속성능을 확인하였다. 최고속도(300 km/h) 상태에서 비상제동 시험결과는 73초의 시간이 소요되었으며 차세대고속철도차량(HEMU-430X)에 적용된 공압식 제동장치의 성능시험 결과와 비교를 통하여 제동소요 시간 및 감속패턴의 유사함 확인하였다.

임플란트-지대주-나사의 적합에 관한 연구 (A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE)

  • 김낙형;정재헌;손미경;백대화
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.