• Title/Summary/Keyword: Torque Load

Search Result 1,105, Processing Time 0.026 seconds

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

Analysis for Roll Forming Process to Levitation Rail of Urban Maglev System (도시형 자기부상열차 부상레일의 롤 성형공정 해석)

  • Kim, Kyung-Taek;Kim, Jae-Yong;Kim, Yong-Hwan;Park, Jin-Soo;Pyen, Sang-Yun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.31-38
    • /
    • 2008
  • This Study discussed the roll forming process analysis of levitation rail for urban Maglev vehicle. To verify validity of roll forming process, we analyzed roll forming process for track shoe which is similar to levitation rail. The analysis process was composed of 12 passes and was performed for only 8 passes except overlapping passes. In the variation of temperature with each pass, surface temperature of the structure was cooled from initial $1200^{\circ}C$ to $1010^{\circ}C$ during 30 second before first pass, and central temperature and surface temperature was cooled to $980^{\circ}C$ and $900^{\circ}C$ in final pass, respectively. A length of structure after final pass is about 5 times longer than that before roll forming process. A strain of structure had a higher value in the inner part of the track shoe and show from minimum 2.5 to maximum 6.5. A torque applying on roll appear high in 2, 3 and 4 passes and a maximum value was $27,000ton{\cdot}mm$. Also it was analyzed that a load to the normal direction needs maximum 300ton.

  • PDF

Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts (볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석)

  • Yeon, Yeong-Mo;Kim, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.67-75
    • /
    • 2020
  • In this study, the risk of heat generation due to normal and overload currents that vary with the abnormal loosening angle of wire-connecting bolts were identified. The risks were analyzed based on the thermal characteristics to minimize the carbonization accidents of terminal blocks inside distribution panels typically used in industrial sites. We applied a method for measuring the heating temperature and temperature variations in the terminal blocks in real-time by installing a resistance temperature detector sensor board in the terminal block. The experimental results showed that the terminal block model with a low-rated current exhibited a higher heating temperature, thus, confirming the need to select the terminal block capacity based on load currents. Additionally, the higher the rated current of the terminal block with a high-rated current and the higher the degree of loosening, the faster the carbonization point. Such heating temperature monitoring enabled real-time thermal temperature measurement and a step-by-step risk level setting through thermal analysis. The results of the measurement and analysis of carbonization risks can provide a theoretical basis for further research regarding the risk of fire due to carbonization. Furthermore, the deterioration measurement method using the temperature sensor board developed in this study is widely applicable to prevent fires caused by poor electrical contact as well as risk-level management.

Speed Control for Electric Motorcycle Using Fuzzy Controller (퍼지 제어기를 이용한 전기 이륜차의 속도 제어)

  • Ban, Dong-Hoon;Park, Jong-Oh;Lim, Young-Do
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.361-366
    • /
    • 2012
  • This paper presents speed control of an electric motorcycle using a fuzzy controller. The electric motorcycle required to meet not only fast throttle response but also stability, when it is on a cruise. However, a 1.5KW (50cc) electric motorcycles selling in the current market are difficult to cruise under the following conditions which are occupant's weight, load weight, wind resistance and road conditions (dirt roads, asphalt road). Because of these reasons, the rapid speed changing occurs in uphill and downhill road. To solve these problems, The input value for Improved fuzzy controller use the speed error and error variance. The output value for improved fuzzy controller uses Q-axis of the motor controlled variable. The D-axis of the motor output for improved fuzzy control uses D-axis controlled variable in proportional to Q-axis controlled variable. Improved fuzzy controller drives the electric motorcycle equipped with IPMSM. The control subject used in this paper is a 1.5KW electric motorcycle equipped with improved fuzzy controller that was used to control the motor speed. To control IPMSM Type of motor torque, D, Q-axis current controller was used. The Fuzzy controller using the proposed algorithm is demonstrated by experimental hardware simulator.

A Study on the Flame Retardance and Electrical Properties of Silicone Composites (실리콘 복합체의 내화 및 전기 특성에 관한 연구)

  • Lee, Sung-Ill;Lee, Hae-Joon
    • Elastomers and Composites
    • /
    • v.38 no.3
    • /
    • pp.227-234
    • /
    • 2003
  • Silicone composites for high voltage insulator (HVI SC) were prepared by adding aluminum trihydrate(ATH) treated by surface treatment agent to base silicone compound at the ratio oi 100:20, 100:40, 100:60, 100:80, and 100:100, respectively And also, ATH was treated by various surface treatment agents, such as stearic arid, acryl silane, and vinyl silane under compounding process. Mechanical properties and electrical properties were investigated for the various contents of ATH and surface-treatment agents. Mechanical properties such as tensile strength, elongation, and tear strength decreased as the load of ATH increased. Volume resistivity, AC break down strength, and tracking resistance for HVI SC containing ATH treated by vinyl silane were better than those for HVI SC containing ATH treated by other surface treatment agents, such as stearic acid and acryl silane. Polymer-filler interaction of silicone composites according to surface treatment agents was studied by measuring bound rubber contend(BR). From the experimental results, BR of silicone composite containing ATH treated with vinyl silane was higher than that of the others. The degree of rule for silicone composite was investigated using Rheometer. Maximum torque of silicone composites contaning ATH treated with vinyl silane was higher than that of silicone composite contaning ATH treated with other surface agents.