• Title/Summary/Keyword: Top Oil Temperature

Search Result 46, Processing Time 0.032 seconds

A Diagnostic Technique for Distribution Transformers using Top Oil Temperature (최상부 유온을 이용한 배전용 변압기의 진단 기법)

  • Choe, Do-Hyeok;Yun, Yong-Han;Min, Gyeong-Rae;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.5
    • /
    • pp.242-251
    • /
    • 2000
  • In this paper, we argued the possibility of the diagnostic technique for distribution transformers using the top oil temperature rising above the ambient temperature. The proposed diagnostic technique used the reference top oil temperature rising at rated current. We determined the emergency value of the transformer using the limitation of the top oil temperature rising and calculated the loss of life. The top oil temperature rises because of the load currents. In this point, the proposed diagnostic technique was explained. The proposed system measures the load current, top oil temperature and ambient temperature. With the diagnostic device, we tested the top oil temperature rising of t재 transformers. Then the loss of life was calculated by the top oil temperature.

  • PDF

The Effect of Engine Oil Degradation and Piston Top Ring Groove Temperature on Carbon Deposit Formation Part II - The Deposit Formation Characteristics of Diesel Engine (엔진 오일 열화와 피스톤 톱링 그루브 온도가 카본 디포짓 형성에 미치는 영향 Part II-디젤 엔진의 디포짓 형성 특성)

  • 김중수;민병순;오대윤;최재권
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.108-113
    • /
    • 1998
  • In order to investigate the characteristics of top ring groove deposit formation in diesel engine, engine test and simulation test were performed. From component analysis of used oils sampled from actual running engines, soot content in engine oil was selected as a main parameter for evaluating oil degradation. Deposit formation is highly related to soot content in lubricating oils. And high soot content oil accelerates deposit formation even in low temperature region below 26$0^{\circ}C$. In low temperature region below 26$0^{\circ}C$, deposit formation rate is mainly affected by top ring groove temperature. However, in high temperature region above 26$0^{\circ}C$, deposit formation rate is affected by soot content as well as top ring groove temperature. Therefore, soot content as well as top ring groove temperature should be kept a certain level in order to prevent troubles due to carbon deposit formation.

Overload Criterion of Mineral-Oil-immersed Distribution Transformers Rated 100kVA and Less Using the Characteristics of Top-Oil Temperature Rising (최상부 유온 상승 특성을 이용한 100kVA 이하 유입식 배전용 변압기의 과부하 판정 기준)

  • Yun, Sang-Yun;Kim, Jae-Chul;Park, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.11
    • /
    • pp.559-567
    • /
    • 2002
  • This paper presents the general recommendations for the overload criterions of mineral-oil-immersed distribution transformers rated 100kVA and less. For this purpose, we analyze the characteristics of top-oil temperature rising for mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea, In order to analyze the characteristics of top-oil temperature rising due to the distribution transformer loading, we performed experiments at KERI (Korea Electrical Research Institute) from December 2000 to May 2001. The restraint of ambient temperatures for the experiment results is solved using the results of foreign standards. Finally, we present the overload criterions of distribution transformer for summer and winter season, respectively.

Overload Criterion of Mineral-Oil-Immersed Distribution Transformers Rated 100kVA and Less (100kVA 이하 유입식 배전용변압기의 과부하 판정기준 설정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Lee, Young-Suk;Park, Chang-Ho;Shon, Hwa-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.6-8
    • /
    • 2001
  • This paper covers general recommendations for top-oil temperature rising of mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea. In order to analyze the top-oil temperature rising due to the distribution transformer loading we performed experiments for oil-immersed distribution transformer, manufactured in domestic at KERI(Korea Electrical Research Institute) from December 2000 to May 2001. The magnitude of loading were changed, and the top-oil temperatures for each time were measured. Finally, we present the overload criteria of distribution transformer for summer and winter season in domestic. respectively.

  • PDF

Transformer Temperature forecast method using Top Oil Temperature Rising & Current (최상부 유온 상승과 전류를 이용한 변압기 온도 예측 방법)

  • Ko, Dong-Wook;Kim, Kwang-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1689-1690
    • /
    • 2008
  • In this paper, The method of a temperature rasing forecast is suggested and simulated. The data used in this simulations exists in the KD Power and it was obtain by real transformer. The method of temperature forecast is based on a top oil temperature rising modeling which is proposed by the IEEE journal. We propose modifications of a modeling that accurately predicts a future transformer temperature. This Method is verified by simulations.

  • PDF

The Effect of Gasoline Engine Oil Degradation and Piston Temperature on Carbon Deposit Formation; Part I-Characteristics of deposit formation on gasoline engine (엔진 오일 열화와 피스톤 온도가 카본 디포짓 형성에 미치는 영향 Part I-가솔린 엔진의 디포짓 형성 특성)

  • 김중수;민병순;이두순;오대윤;최재권
    • Tribology and Lubricants
    • /
    • v.13 no.4
    • /
    • pp.33-39
    • /
    • 1997
  • In order to establish a new temperature criterion to prevent the pistons from ring sticking due to deposit formation, bench test and engine test were performed. The effects of oil degradation and temperature on deposit formation was studied by a modified panel coking test. Oil degradation was analyzed by FTIR. Oil oxidation and nitration were selected as a factors to evaluate oil degradation. Bench test results show that oil oxidation is more effective to the deposit formation than oil nitration. And the temperature increase accelerates deposit formation and deposit formation increase rapidly above 26$0^{\circ}C$. Especially, in case of degraded oil, the deposit formation increases so rapidly that ring sticking can occur. The effect of piston temperature on the deposit formation was confirmed by engine test.

Low-Temperature Microencapsulation of Sesame Oil Using Fluidized Bed Granulation (Fluidized bed granulation을 이용한 참기름의 저온 미세캡슐화)

  • Jeong, Chan-Min;Lee, Min-Kyung;Lee, Hyun-Ah;Park, Ji-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • Top spray-drying method is frequently utilized for flavor encapsulation, but the top spray-dried products frequently suffer from high losses of volatile flavor as the result of a high processing temperature (150-$300^{\circ}C$). In an effort to solve these problems, a low-temperature fluidized-bed granulating method was utilized to encapsulate the flavor. For the encapsulation of sesame oil, oil-in-water emulsions of sesame oil and a mixture of maltodextrin, modified starch, gum arabic, and gellan gum were bottom-sprayed at milder temperatures (70-$100^{\circ}C$) using a fluidized-bed granulator. Sesame oil extracts from microcapsules were obtained via a simultaneous distillation/extraction technique, and the retention of volatile flavor compounds was analyzed via a gas chromatography-mass spectrometry. The retention of volatile flavors of sesame oil per se, spray-dried and fluidized-bed granulated microcapsules after 3-day-storage at $37^{\circ}C$ were 0.8%, 37.2%, and 42.0%, respectively. In addition, the low-temperature fluidized-bed granulation showed higher encapsulation yield and sensory preferences for the application of commercial products (beef rice porridge), as compared to spray drying.

Evaluation of Structural Integrity and Cooling Performance of 4250 kVA Power Transformer with ONAN Mode (ONAN 모드 4250kVA 변압기의 구조 건전성과 냉각 성능의 평가)

  • Yang, Chaofan;Kim, Seongik;Cho, Jong-Rae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.48-57
    • /
    • 2021
  • The main research content of this paper is to evaluate the structural integrity and the cooling performance of 4250 kVA power transformer with ONAN(Oil Natural and Air Natural) mode. The dynamic analysis is used to verify the structural safety of the transformer by seismic loading. The transformer structure is simplified and NX software is used to build a three-dimensional model, and ANSYS commercial software is used to calculate the stress and deformation by applying corresponding load. The analysis result was evaluated whether it satisfies the design requirements according to the IEEE Std 693 standard. In terms of thermal analysis to evaluate the cooling performance, the thermal physical model is used to calculate the heat exchange between the radiator and the tank in the steady state, and the result is input into the Fluent software to calculate the internal temperature field of the transformer tank, which reduces the calculation cost of thermal fluid. Comparing the simulated hot spot temperature and top oil temperature of the transformer with the calculation results of the IEC60076 classic model, it is found that the error is only 1.9%.

A Study on the Diagnostic Technique for Distribution Transformers using Multi-Channel Wireless Communication Network (다채널 무선 통신망을 이용한 배전용 변압기 진단 기법에 관한 연구)

  • Kim, Jae-Chul;Choi, Joon-Ho;Kim, Dong-Hyun;Moon, Jong-Pil;Kim, Oun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.131-139
    • /
    • 2001
  • As increasing the accident of Distribution Transformer (DT), we need to manage them efficiently. In this paper, we discusses with the possibility of the diagnostic technique for distribution transformer using relative ageing rate calculation in this paper. The relative ageing rate of the DT could be calculated from the measured top oil temperature, ambient temperature and load current. In order on apply the proposed diagnostic technique we developed an on line Monitoring and Diagnostic System (MDS) which has hardware and software part. Diagnostic device is developed to measure the state information of DT and to send them with R/F(radio frequency) communication. Host computer monitors and saves the receive data. The database is constructed from the data of distributed DT and it is used for estimating loss-of-life in the MDS.

  • PDF

A Study on Effect of Scale Formation in Water Jacket on Thermal Durability in LPG Engine (엔진 물통로 내부 벽면 스케일 축적이 LPG 엔진의 열적 내구성에 미치는 영향에 대한 연구)

  • 류택용;신승용;최재권
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.42-50
    • /
    • 2001
  • In this paper, the effects of scale formation in engine water jacket upon the thermal durability of engine itself and its component parts were studied. To understand the effect of quality of water, a full load engine endurance test for 50 hours was carried out with not-treated underground water. The followings were found through the tested engine inspection after the endurance test; 1-2 mm thick scale formation in the engine water jacket, valve seat wear, piston top land scuffing, piston pin stick, and cylinder bore scuffing in siamese area. In order to understand the causes of above test results, the heat rejection rate to coolant, the metal surface temperature of combustion chamber, and the oil and exhaust gas temperatures were measured and analyzed. The scale formed in the engine water jacket played a role as thermal insulator. The scale formed in the engine reduced the heat rejection rate to coolant and it caused to increase the metal surface temperature. The reduced heat rejection rate to coolant increased the heat rejection rate to oil and exhaust gas and increased the oil and exhaust gas temperature. Also, the reasons of valve seat wear, piston top land scuffing and cylinder bore scuffing, and piston pin stick quantitatively analyzed in this paper.

  • PDF