• Title/Summary/Keyword: Tooth crown

Search Result 511, Processing Time 0.024 seconds

A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION (기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구)

  • Kim, Byung-Hyun;Lee, Young-Kyoo;Kim, Young-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF

The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study

  • Ha, Seung-Ryong;Kim, Sung-Hun;Han, Jung-Suk;Yoo, Seung-Hyun;Jeong, Se-Chul;Lee, Jai-Bong;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.187-197
    • /
    • 2013
  • PURPOSE. The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns. MATERIALS AND METHODS. Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a $45^{\circ}$ angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position. RESULTS. In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased. CONCLUSION. This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.

INFLUENCE OF VARIOUS PROPERTIES OF POST AND CORE ON THE STRESS DISTRIBUTION IN ENDODONTICALLY TREATED TOOTH (다양한 포스트와 코어의 물성이 근관치료된 치근의 응력분산에 미치는 영향)

  • Cho Jin-Hyun;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.10-19
    • /
    • 2006
  • Statement of problem : The various kinds of properties of post and core may affect the stress distribution to the root of endodontically treated teeth Purpose: To evaluate the influence of various kinds of properties of post and core to the stress distribution to the root of endodontically treated teeth. Material and methods: Mandibular first premolar, prepared by general shape of post and core with gold crown, was used to two dimensional axisymmetric modeling for finite element analysis. Then property values of 8 different kinds of post and core was substituted for each. Finally, stress distribution shown areas around the root of post and core was analysed after applying 50N of vortical and oblique load. Results: 1. Stress value of oblique load was much higher than the maximum stress value of vertical load. 2. Under oblique load, very concentrated stress was located on post periapical area and variations in stress were very severe. Contrary to this, stress distribution was relatively uniform in vertical load. 3. Post materials with higher elastic modulus showed relatively more apically focused stress, and post materials with lower elastic modulus showed stress focused on cervical area on the axial wall of post. 4. Stress change according to the properties of core was shown only in the cervical area of post and below core as the higher elastic modulus, then increased in stress. 5. Post and core with medium value of elastic modulus showed relatively uniform stress distribution. Conclusions: Post materials with higher elastic modulus showed relatively more apically focused stress, and post materials with lower elastic modulus showed stress focused on cervical area on the axial wall of post. Stress change according to the properties of core was shown only in the cervical area of post and below core.

CHANGES IN INTRADENTAL NERVE ACTIVITY FOLLOWING LOCAL APPLICATION OF CGRP, SP AND ELECTRICAL STIMULI IN CATS (CGRP, SP의 국소도포와 전기자국에 의한 고양이 치수신경활동의 변화)

  • Kim, Mi-Ja;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.527-537
    • /
    • 1995
  • The effect of calcitonin gene-related peptide (CGRP), substance P (SP) and electrical stimulation of the tooth on the intradental nerve activtiy (INA) was investigated in anesthetized cats. The INA was recorded from single pulp nerve units dissected from the inferior alveolar nerve under stereomicroscope. The INA elicited by 3 minute application of 4M NaCl in deep dentinal cavity was compared before and after stimulation at 10 minute intervals. The magnitude of INA was calculated as the total number of nerve impulses produced in given period, and the changes of INA are expressed as % of control INA. The results obtained were as follows. 1. 16 single pulp nerve units were classified as 14 $A{\delta}$-fibers (3.4~19.4m/sec) and 2-fibers (1.5~1.7m/sec) according to the conduction velocity. 2. 4M NaCl evoked an irregular bursts of spikes which continued until washing out. Isotonic saline did not affect INA to subsequent applications of the hypertonic NaCl solution (P>0.05). 3. Local application of CGRP ($200{\mu}g$/ml) in deep dentinal cavity reduced the INA induced by 4M NaCl in $A{\delta}$-fiber units (P<0.01) and some units of those responded to CGRP during application. 4. Local application of SP ($100{\mu}g$/ml) in deep dentinal cavity reduced the INA induced by 4M NaCl in AS-fiber units (p<0.05), but increased the INA in C-fiber unit coincided with large reduction of the INA of $A{\delta}$-fiber units. 5. Monopolar electrical stimulation applied to the crown at intensities high enough to excite C-fibers (12V, 5ms, 10Hz, 10~30min) decreased the INA in $A{\delta}$-fiber units (P<0.01) and systemic pretreatment with phenoxybenzamine (3mg/kg, i.v.) enhanced this inhibitory effect (P<0.01). On the contrary, electrical stimulation increased the INA in C-fiber unit.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF INTERNAL DISCOLORATION OF TEETH BY ENDODONTIC SEALERS (수종(數種) 근관(根管) 충전재(充塡材)에 의(依)한 치아(齒牙) 내부(內部) 변색효과(變色效果)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Geol, Kim-In;Cho, Jae-O
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.2
    • /
    • pp.65-72
    • /
    • 1987
  • The purpose of this study was to examine the influence of several root canal sealers on the discoloration of internal surface after root canal obstruction. Twenty four sound human premolars, extracted for orthodontic or prosthodontic purposes, were randomly selected and divided into eight groups. Extracted premolars were prepared, and the following seven materials were introduced into the pulp cavities: AH 26, Fuji ionomer (Type I) cement, N2, Oxypara "Murakami", Kerr sealer, PCA sealer, and G-C's Propac ZOE cement. After 7 weeks of incubation; the discolored tooth crowns were hemisectioned, and the internal staining patterns were examined. Then, with an association of observed values the mean intensity scores and percentage of coverage scores of the internal staining patterns in teeth attained by two observers using for Chisquare test were analyzed. The results were as follows: 1. All the experimental premolar's crown showed various ranged discoloration of internal surface. 2. There was no significance between the association scores of two observers participated into this experiments:% coverage scores (P > 0.05) and intensity (P > 0.05) 3. The crowns filled with PCA sealer, AH 26, and Fuji ionomer cement was visible within a depth of one third of dentin. (P> 0.05) 4. For N2, Kerr sealer, and G-C's Propac cement, A slight dentinal staining was recorded, which penetrated up to half way into the dentin. (P> 0.05) 5. It was noticed that the teeth filled with Oxypara "Murakami" were discolored more than two thirds of the dentinal layer. 6. On the control group, there was no discoloration.

  • PDF

A STUDY ON THE DENTIN BONDING OF ONE-STEP BONDING AGENT (ONE-STEP 접착제의 상아질 접착에 관한 연구)

  • Cho, Young-Gon;Park, Sung-Taek;Park, Kwang-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.468-476
    • /
    • 1998
  • The purpose of this study was to observe the morphologic change of dentinal surface, adhesion in interface between dentin and bonding agents, and penetration pattern of resin tags into dentinal tubles according to bonding procedure of ONE-STEP universal adhesive system. Ten extracted human molars were mounted in dental stone and sectioned to expose mid-coronal occlusal dentin and again sectioned tooth crown apically. Specimens were randomly assigned to three groups for dentin conditioning with 32% phoshoric acid, two coats of bonding agents after dentin conditioning, and bond of composite resin. The surfaces of dentin were treated with etch ant and applied bonding agent, and bonded composite resin according to the directions of manufacturer. Specimens which were boned composite were sectioned longitudinally for observing interfaces between resin and dentin. Two of specimens which were sectioned longitudinally were immersed in 6 N HCL for 30 seconds and 1% NaOCL for 12 hours to partially demineralize and deproteinize the dentin substrate. Each specimen was mounted on a brass stub, sputter-coated with gold and observed under SEM. The result were as follows : 1. On the dentinal surface which was conditioned with 32% phosphoric acid. the smear layer was completely removed. orifices of dentinal tubules were opened 3-$5{\mu}m$ wide. and dentinal surface was irregular. 2. On the dentinal surface which was applied ONE-STEP. bonding agent. resin particles were observed on the orifices of dentinal tubules and intertubular dentin. 3. There were close adaptation between dentin and resin and were the pattern which composite invaded into dentin. 4. 1-$3{\mu}m$-wide hybrid layer was visible in the interface between dentin and resin. 5. Long and funnel shaped resin tags were observed in demineralized specimens. and the surfaces of tags were rough.

  • PDF

Evaluation the clinical acceptability of the marginal and internal gaps of fixed partial denture fabricated with additive manufacturing technology (적층 가공방식에 따른 고정성 치과보철물의 변연 및 내면 적합도 평가연구)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.40 no.4
    • /
    • pp.209-215
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the clinical acceptability of the marginal and internal gap of Co-Cr metal copings fabricated with stereolithography (SLA). Methods: Titanium master dies were milled after scanning of the prepared tooth (n=30). For group I, Co-Cr metal copings were made from conventional lost-wax technique(LWT, n=10). For group II, the master dies were scanned and designed with CAD system. Then, metal copings were milled with Co-Cr(SUB, n=10). For group III(ADD, n=10), the scanning and design procedures were same as group II and burn-out resins were fabricated with SLA device. The marginal and internal discrepancies were measured under an optical microscope(100x) on ten reference points and were statistically analyzed with one-way ANOVA(${\alpha}=.05$). Results: The mean total discrepancies were $53.76{\pm}12.42{\mu}m$ in the LWT group and $69.82{\pm}15.48{\mu}m$ in the ADD group. The SUB group showed the largest total mean value $110.33{\pm}13.77{\mu}m$. There was statistically significant difference between the SUB and the other groups(P<0.05). Conclusion : Co-Cr metal copings fabricated with SLA technology showed clinically acceptable value on marginal and internal gap and there was no statistically significant difference between conventional lost-wax technique and SLA.

Pontic site development with an implant submergence technique for unaesthetic implant in the anterior maxilla (상악 전치부 임플란트의 비심미성 개선을 위한 임플란트 침수(submergence)를 동반한 치조제 증대술)

  • Song, Yujeong;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.289-295
    • /
    • 2020
  • Improving implant esthetics is very difficult, especially in cases where unaesthetic problems are related to implants in the maxillary anterior dentition. A 69-year old male patient was referred by a prosthodontist for periodic pus discharge and an unaesthetic implant prosthesis (maxillary right lateral incisor). The implant was placed too deeply and showed soft tissue volume deficiency and a long clinical crown. After a clinical and radiographic examination, implant submergence and alveolar ridge augmentation were performed to enhance the aesthetics instead of an explantation. The treatment plan was as follows: extraction the adjacent teeth with tooth mobility, secondary caries, and poor prognosis; placement an additional dental implant with hard and soft tissue grafting; fabrication a fixed bridge using implant abutments. A fixed esthetic prosthesis using implants was fabricated, and the patient was satisfied with the prosthesis. A ridge augmentation with implant submergence may be an alternative for solving the problems of unaesthetic implant restorations in the esthetic zone.

Axial displacement in single-tooth implant restoration: Case report (임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고)

  • Jeong, Seung-Hoe;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.126-133
    • /
    • 2021
  • Axial displacement of an implant-supported prosthesis is frequently reported in clinical and laboratory studies. However, limited information is available about the behavior of the axial displacement of implant-supported prostheses functioning in intraoral situations. The present case report evaluated the three-dimensional displacement of posterior single implant-supported prostheses in 2 different patients. Internal connection type implants were placed, and screw and cement-retained prosthesis (SCRP) type prosthesis were delivered after an appropriate healing period. Intraoral digital scans were performed using an intraoral scanner (Cerec Omnicam, Dentsply Sirona, USA) on the day of crown delivery and one week, one month, and one year after delivery. The amount of 3-dimensional displacement of the prosthesis was evaluated by using a digital inspection software (Geomagic Control X, 3D systems, USA). The axial displacement of implant-supported prosthesis occurred in both patients. Furthermore, the amount of displacement increased over time.

Convergence analysis of cusp variation symmetry of the mandibular second premolars using 3-dimensional virtual models - Focusing on college students in Jeollabuk-do (3차원 가상모형을 이용한 하악 제2소구치 교두 변이 대칭성에 대한 융복합적 분석 - 전북지역 일부 대학생을 중심으로)

  • Nam, Shin-Eun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.317-323
    • /
    • 2022
  • This study aimed to qualitative analyze the cusp variation pattern of the mandibular second premolars using a three-dimensional virtual models, and to analyze the left-right bilateral symmetry with a quantitative analysis of the tooth surface area according to the cusp variation. 127 virtual mandibular second premolars were prepared and individual absolute/relative cusp area, total crown area and groove form were analyzed using RapidForm2004(INUS technology INC, Seoul, Korea). Independent t-test, Kruskal-Wallis test and chi-square were performed. As a result, the groove form showed high bilateral symmetry between the left and right sides. Based on the left side of groove form, the bilateral symmetry was 100.0% for the U pattern, and 73.7% for the H patterned, and 78.9% for the Y pattern(p<.001). The finding could be as a meaningful reference for manufacturing CAD/CAM dental prostheses, and it is expected that further studies will be conducted on more samples including the mandibular second premolar immediately after eruption.