• Title/Summary/Keyword: Tooth Surface

Search Result 875, Processing Time 0.026 seconds

A Study on the Surface Roughness Variation of Spur Gear Teeth as a function of the Surface Treatment (표면처리에 따른 평기어 치의 표면거칠기 변화에 관한 연구)

  • 유장열;이성철;권오관;정태형
    • Tribology and Lubricants
    • /
    • v.7 no.2
    • /
    • pp.67-74
    • /
    • 1991
  • The contact characteristics of gear tooth surface were studied by using the gear test rig of power circulation type. The effect of surface treatment conditions and revolutions on the tooth surface roughness parameters, and the relations between the lubrication conditions and tooth surface conditions, in spur gear sets wear considered. The result show that heat treatment of gear have an important effect upon fatigue strength and tooth surface conditions, and surface asperities undergo a circulating process of creation and destruction because of the influnce of plastic deformation. And surface roughness conditions at the tooth tips accompany a great deal of variation in running-in stage. According to the lubrication analysis and the study the tooth surface have a greater effect on surface demage than lubrication conditions, in mixed-lubrication condition.

Optimization of the Tooth Surface in the Helical Gears Using a Response Surface Method (반응표면법을 이용한 헬리컬기어 치형수정의 최적화)

  • Park, Chan-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.760-763
    • /
    • 2005
  • Optimum design of the tooth surface for the reduction of transmission error is very difficult to determine analytically due to nonlinearity of transmission error under the several load condition. The design of tooth surface that can give a low noise under the various load condition is very important. Therefore, this study proposes the method to determine the optimal lead curve and robust design of the tooth surface by using the response surface method. To do so, the design variables are selected by a screening experiment. Then the fitted regression model Is built with the check of the usefulness of the model. The model with constraints is solved to obtain the optimum values for the lead curve and the robust design fur the tooth surface.

  • PDF

Alteration of Hydroxyapatite Surface after Tooth Bleaching with Nonthermal Atmospheric Pressure Plasma

  • Nam, Seoul Hee;Lee, Hae June;Hong, Jin Woo;Kim, Gyoo Cheon
    • International Journal of Oral Biology
    • /
    • v.39 no.4
    • /
    • pp.187-192
    • /
    • 2014
  • Nonthermal atmospheric pressure plasma has attracted great interest for biomedical applications. The plasma consists of charged particles, radicals, and a strong electric field as the fourth state of matter. This study evaluated the change in the surface roughness after tooth bleaching by plasma in combination with a low concentration (15%) of carbamide peroxide, specifically whether the application of plasma produced detriments, such as demineralization and structural change, with the goal of efficient and safe tooth bleaching. After being combined with plasma and 15% carbamide peroxide, the hydroxyapatite surface was significantly smoother with a low roughness average value. Tooth bleaching with 15% carbamide peroxide alone produced an irregular surface and increased the surface roughness with high roughness average value. Tooth bleaching with plasma resulted in no significant variations in hydroxyapatite in terms of change in surface roughness and surface topography. The application of tooth bleaching with plasma is not deleterious to dental hard tissue, implicating it as a safe tooth bleaching technique.

Analysis on load-bearing contact characteristics of face gear tooth surface wear with installation errors

  • Fan Zhang;Xian-long Peng
    • Computers and Concrete
    • /
    • v.31 no.2
    • /
    • pp.163-171
    • /
    • 2023
  • Face gear transmission is widely used in aerospace shunt-confluence transmission system. Tooth wear is one of the main factors affecting its bearing transmission performance. Furthermore, the installation errors of face gear are inevitable. In order to study the wear mechanism of face gear tooth surface with installation errors, based on tooth contact analysis numerical method and Archard wear theory, the UMESHMOTION subroutine in ABAQUS is developed.Combining with Arbitrary Lagrangian-Eulerian adaptive mesh technology, the finite element mesh wear model of abraded face gear pair is established.The preprocessing conditions are set to generate the inp files.Then,the inp files for each corner are imported and batch processed in ABAQUS.The loading tooth contact problem at each rotation angle is solved and the load distribution coefficient among gear tooth, tooth root bending stress, tooth surface contact stress and loaded transmission error are obtained. Results show that the tooth root wear is the most serious and the wear at the pitch cone is close to 0.The wear law of tooth surface along tooth width direction is convex parabola and the wear law along tooth height direction is concave parabola.

Analysis of Tooth Profile Accuracy of Enveloping Worm Thread Depending on End Mill Tool Shape (장구형 웜 나사의 절삭 엔드밀 공구 형상에 따른 치형 정밀도 분석)

  • Kang, S.J.;Kim, Y.H.
    • Transactions of Materials Processing
    • /
    • v.28 no.4
    • /
    • pp.183-189
    • /
    • 2019
  • Cylindrical worm reducers are generally used in various fields and forms throughout the industry, and demand is increasing due to their role as an integral part of the industry. Market trends require high-load, high-precision components, and small-sized reducers with large loads. When using a cylindrical worm reducer, a reducer designed with a reduced center distance while maintaining the same output torque results in gear wear. To overcome this difficulty, an enveloping worm gear reducer is introduced and studied. In this paper, three types of end mill tools are used to evaluate the tooth profile accuracy for each tool shape during machining of the tooth profile for a non-developed surface worm thread. The effect of the endmill shape on the accuracy of the tooth profile was analyzed by performing 3D modeling of the surrounding worm tooth profile based on the Hindley method. In this study, we analyzed tooth profile accuracy, tooth surface roughness, and tooth surface machining time, etc. Through the study, efficient machining conditions for the enveloping worm gears and the influence of parameters on the process were presented.

Sub-surface Stress Analysis on Spur Gear Teeth in the EHL Conditions

  • Koo, Young-Pil;Kim, Tae-Wan;Cho, Yong-Joo
    • KSTLE International Journal
    • /
    • v.5 no.1
    • /
    • pp.14-22
    • /
    • 2004
  • The sub-surface stress field beneath the gear's contact surface caused by the surface pressure in lubricated condition is analyzed. To evaluate the influence of the clearances between a gear tooth and a pinion tooth on the stress field, two kinds of tooth profile models - conventional cylinder contact model and new numerical model - were chosen. Kinematics of the gear is taken into account to obtain the numerical model which is the accurate geometric clearances between a gear tooth and a pinion tooth. Transient elasto-hydrodynamic lubrication (EHL) analysis is performed to get the surface pressure. The sub-stress field is obtained by using Love's rectangular patch solution. The analysis results show that the sub-surface stress is quite dependent on both the surface pressures and the profile models. The maximum effective stress of the new model is lower than that of the old model. The depth where the maximum effective stress occurs in the new model is not proportional to the intensity of the external load.

EXPERIMENTAL STUDIES OF THE EFFECT OF EROSION ON THE TOOTH ENAMEL SURFACE BY ACID BEVERAGES PURCHASED ON THE RETAIL MARKET (수종의 시판 청량음료가 치아표면 법랑질 침식에 미치는 영향에 관한 실험적 연구)

  • Ha, Joo-Sik;Kim, Chong-Youl
    • The Journal of the Korean dental association
    • /
    • v.19 no.11 s.150
    • /
    • pp.949-956
    • /
    • 1981
  • The author collected some acid containing beverages to observe the influence which acid containing beverages affect the tooth surface tissue and the resistance of tooth which was treated with fluoride and counterpart tooth in the acid containing beverages and comparatively observing the erosion of enamel surface, the author came to the following conclusion. 1. Acid containing beverages on the market eroded the tooth surface tissue and the erosion degree was determined by the pH concentration of beverages. 2. the erosion aspect of the tooth surface in terms of acid containing beverages indicated some on the surface and surrounding enamel rod in the beverages which the pH was comparatively high, and the erosion was observed greatly in all enamel including the enamel rod in the beverages which pH was high. 4. When one drinks beverages, if beverges' pH is high, there are no serious harmful, but the author recommended not drinking the beverages which pH is low under the situation lack of the proper preventive dentistry technique.

  • PDF

A STUDY OF THE DEPTH OF THE ROOT CONCAVITY AND ROOT SURFACE AREA MEASUREMENT OF THE MAXILLARY FIRST PREMOLAR (상악 제1 소구치의 치근면 함요도 및 치근표면적에 관한 연구)

  • Lim, Sang-Cheol;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.165-177
    • /
    • 1994
  • To investigate the depth of the root concavity and root surface area of the maxillary first premolar, 40 maxillary first premolars were used. All the teeth which extracted because of advanced periodontal disease and orthodontic treatment procedure, were sectioned every 1.5mm from cementoenameljunction to the apex with hard tissue microtome. Each sectioned root was taken photograph with slide film, and projected for measuring with a calibrated digital Curvi-Meter. The root surface area, percentage of the RSA and the linear variation of the RSA were calibrated for each 1.5mm section. Linear variation of the depth of root concavity was measured on mesial and distal root surface for each section using computer-aided digitizer. The results were as follows. 1. The total mean root length of maxillary first premolar was 13.48mm. Mean buccal root length of 2-rooted tooth was 12.59mm, mean palatal root length was 12.73mm, and mean root length of single rooted tooth was 13.78mm. 2. The total mean root surface area of maxillary first premolar was $194.17mm^2$, mean root surface area for 2-rooted tooth was $205.97mm^2$ and mean root surface area for single rooted tooth was $188.49mm^2$. 3. It was 59.93% of the total root surface area that the area from CEJ to coronal 6mm. And, the coronal half of the root length accounted for approximately 71.76% of the total root surface area. 4. Most deepest concavity of the mesial root surface was 0.65mm at apical 3.0mm, 4.5mm level in maxillary first premolar. And, that of the distal root surface was 0.37mm at apical 4.5mm level. 5. All of the maxillary first premolar had mesial root surface concavity. This mesial root surface concavity appeared to be more pronounced in 2-rooted tooth than single rooted tooth.

  • PDF

Analysis of Tooth Surface Compressive Stress of Conical Involute Gear by Profile Modification (치형수정에 의한 코니칼 인볼류트 기어의 치면 압축응력 해석)

  • Kim, Junseong;Lee, Hyeonsu;Kim, Donguk;Lyu, Sungki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.5
    • /
    • pp.40-49
    • /
    • 2010
  • Conical involute gears are being used for marine gearboxes, automotive transmissions, and robots, and so on, but not much. As involute profile gear, conical involute gear not only can be engaged with spur and helical gear but also can be used for power transmission of parallel, crossed and skewed axis with small angle. Hence, conical involute gears are likely to develop in future. Through a study on the basic theory of conical involute gear, tooth surface compressive stress analysis was performed by using commercial modeling program, comparing before and after profile modification. As a result, it noticed that tooth profile modification is able to relieve more tooth surface compressive stress than before modification.

Minimizing the extra-oral time in autogeneous tooth transplantation: use of computer-aided rapid prototyping (CARP) as a duplicate model tooth

  • Lee, Seung-Jong;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • Objectives: The maintenance of the healthy periodontal ligament cells of the root surface of donor tooth and intimate surface contact between the donor tooth and the recipient bone are the key factors for successful tooth transplantation. In order to achieve these purposes, a duplicated donor tooth model can be utilized to reduce the extra-oral time using the computer-aided rapid prototyping (CARP) technique. Materials and Methods: Briefly, a three-dimensional digital imaging and communication in medicine (DICOM) image with the real dimensions of the donor tooth was obtained from a computed tomography (CT), and a life-sized resin tooth model was fabricated. Dimensional errors between real tooth, 3D CT image model and CARP model were calculated. And extra-oral time was recorded during the autotransplantation of the teeth. Results: The average extra-oral time was 7 min 25 sec with the range of immediate to 25 min in cases which extra-oral root canal treatments were not performed while it was 9 min 15 sec when extra-oral root canal treatments were performed. The average radiographic distance between the root surface and the alveolar bone was 1.17 mm and 1.35 mm at mesial cervix and apex; they were 0.98 mm and 1.26 mm at the distal cervix and apex. When the dimensional errors between real tooth, 3D CT image model and CARP model were measured in cadavers, the average of absolute error was 0.291 mm between real teeth and CARP model. Conclusions: These data indicate that CARP may be of value in minimizing the extra-oral time and the gap between the donor tooth and the recipient alveolar bone in tooth transplantation.