• 제목/요약/키워드: Tooth Material

검색결과 498건 처리시간 0.021초

Effect of different storage media on elemental analysis and microhardness of cervical cavity margins restored with a bioactive material

  • Hoda Saleh Ismail;Brian Ray Morrow;Ashraf Ibrahim Ali;Rabab Elsayed Elaraby Mehesen;Salah Hasab Mahmoud;Franklin Garcia-Godoy
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.6.1-6.16
    • /
    • 2024
  • Objectives: This study aimed to investigate the elemental analysis and microhardness of a bioactive material (Activa) and marginal tooth structure after storage in different media. Materials and Methods: Fifteen teeth received cervical restorations with occlusal enamel and gingival dentin margins using the tested material bonded with a universal adhesive, 5 of them on the 4 axial surfaces and the other 10 on only the 2 proximal surfaces. The first 5 teeth were sectioned into 4 restorations each, then stored in 4 different media; deionized water, Dulbecco's phosphate buffered saline (DPBS), Tris buffer, and saliva. The storage period for deionized water was 24 hours while it was 3 months for the other media. Each part was analyzed by scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS) analysis for different substrates/distances and the wt% of calcium, phosphorus, silica, and fluoride were calculated. The other 10 teeth were sectioned across the restoration, stored in either Tris buffer or saliva for 24 hours or 3 months, and were evaluated for microhardness of different substrates/areas. Data were analyzed using analysis of variance and Tukey's post hoc test. Results: Enamel and dentin interfaces in the DPBS group exhibited a significant increase in calcium and phosphorus wt%. Both silica and fluoride significantly increased in tooth structure up to a distance of 75 ㎛ in the 3-month-media groups than the immediate group. Storage media did not affect the microhardness values. Conclusions: SEM-EDS analysis suggests an ion movement between Activa and tooth structure through a universal adhesive while stored in DPBS.

Use of temporary filling material for index fabrication in Class IV resin composite restoration

  • Kim, Kun-Young;Kim, Sun-Young;Kim, Duck-Su;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • 제38권2호
    • /
    • pp.85-89
    • /
    • 2013
  • When a patient with a fractured anterior tooth visits the clinic, clinician has to restore the tooth esthetically and quickly. For esthetic resin restoration, clinician can use 'Natural Layering technique' and an index for palatal wall may be needed. In this case report, we introduce pre-restoration index technique on a Class IV defect, in which a temporary filling material is used for easy restoration. Chair-side index fabrication for Class IV restoration is convenient and makes a single-visit treatment possible.

자가치아골이식재를 이용한 골이식술의 임상적 평가 (Development of autogenous teeth bone graft material and clinical evaluation)

  • 김영균
    • 대한치과의사협회지
    • /
    • 제49권3호
    • /
    • pp.159-169
    • /
    • 2011
  • The author have been conducting research on the development of biomaterials using human teeth since 1993, and we recently reported the results of several of our advanced studies. Based on previous studies, new bone graft material using autogenous tooth(AutoBT) was developed. The author performed implant placement combined with GBR and sinus bone graft using AutoBT during the period of June 2009 to September 2009. During the postsurgical healing period, clinical and radiological evaluations were performed. For patients who consented to histological testing, tissue samples were obtained and histological examination was performed two months and four months after GBR and four months after sinus bone graft. Serious complications pertinent to bone graft materials were not observed, and it was shown that the level of the crestal bone in the vicinity of implants was relatively well maintained. In histologic examination after two months and four months, favorable new bone formation was observed.

발치 중에 발생한 성문하 이물 1례 (A Case of Subglottic Foreign Body Occurred in Tooth Extraction)

  • 최병권;김기식;권오성;서재범;이종빈
    • 대한기관식도과학회지
    • /
    • 제10권2호
    • /
    • pp.49-51
    • /
    • 2004
  • The lodgement of foreign material in the larynx is potentially life thereatening as complete obstruction of this region does not leave the individual with a viable airway. In the literature review, laryngeal foreign bodies accounted for about $3\%$ of the whole foreign bodies in the air passage. This report describes a rare case of laryngeal obstruction by subglottic foreign body(tooth) occurred during tooth extraction, in which repeated Heimlich maneuver failed to expel the foreign body and aggravated airway obstruction.

  • PDF

Development of the Sub Gear for the Scissors Gear System for Automobile Engines

  • Nakazawa, Katsuhito;Nagata, Toshihiko;Motooka, Naoki
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.756-757
    • /
    • 2006
  • P/M enables the economical production of components for many kinds of gears. Functionally, the sub gear requires high tooth accuracy and bending fatigue strength. The whole tooth profile was sized after sintering to satisfy the gear tooth accuracy specification. The part was redesigned to reduce machining requirements. The required bending fatigue strength was achieved through appropriate material choice and induction of compressive residual stress by shotpeening after carburizing. The P/M sub gear replaced a forged steel gear, satisfied performance requirements, expanded the use of P/M applications and provided over 30% cost reduction.

  • PDF

DLP방식의 치과용 3D프린팅 임시치아 소재의 기계적 특성 (Mechanical Properties of DLP-type Dental 3D Printing Temporary Tooth Material)

  • 정효경;이승희;정효경
    • 한국산업융합학회 논문집
    • /
    • 제24권3호
    • /
    • pp.373-376
    • /
    • 2021
  • Tested the flexural strength and maximum load of two types of dental 3 D printed temporary tooth materials of the DLP method. The average flexural strength was 206.98 MPa in the test group and 139.77 MPa in the control group. The average flexural strength of the experimental group was 67.21 MPa higher than that of the control group. In the maximum load experiment, an average of 44.16N in the experimental group and 37.31N in the control group were measured. The average value of 6.85N was higher in the experimental group, and the durability of the artificial tooth restoration was improved.

3-Dimensional scan을 이용한 치아 마모량 측정 방법에 관한 연구 (A NOVEL 3D SCAN METHOD TO QUANTIFY TEETH WEAR)

  • 김승준;최대균;권긍록;이석형
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.1-10
    • /
    • 2004
  • Statement of problem : Tooth wear is physiological phenomenon. Ninety-seven percent of normal people have tooth wear and about 7% has pathologic teeth wear. If we know the amount of tooth surface loss caused by pathologic tooth wear, we may restore it ideally Purpose : Recently measurement of tooth wear by using 3D scan has been increasing. Therefore, we need to know how accurate 3D scan is. Past accuracy test on 3D scan was about linear change, but as we know that tooth wear is volume change. Thus, the purpose of this study is to know how accurate 3D scan is. Material and Methods : For accuracy test of 3D scanner volume values measured by 3D scanner and micro-balance were compared. For test I, preliminary, 3 ball samples and 3 circular cones were made with pattern resin. For test II, 10 teeth shape rubber samples were used. Results and Conclusion : 1. The result of the accuracy test on 3D scan with 3 ball samples and 3 circular cones made of pattern resin has no significant difference(p<0.05). 2. The result of the accuracy test on 3D scan with 10 samples of tooth shape rubber has no significant difference (p<0.05). As a result, we may concluded the analysis of quantifying tooth wear used by 3D scan is useful in the clinic.

Glass Ionomer Cement의 접착력(接着力)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE BONDING FORCE OF GLASS IONOMER CEMENT)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.77-83
    • /
    • 1981
  • The purpose of this study was to observe the bonding strength between tooth surface (enamel and dentin) and restorative filling materials which are two composite resins (Clearfil and Concise) and Glass ionomer cement, after etching with 50% phoshoric acid and 37% citric acid. To measure the bonding strength in enamel, the labial surface of upper anterior tooth was cut flatly with using carborundum disk and polished with sand paper disk, and to measure in dentin, the dentin surface was prepared by grinding upper part of posterior tooth horizontally. After washing the tooth surface with water and drying with air blast, the prepared tooth surface was etched. In glass ionomer cement, 50% phosphoric acid and 37% citric acid were used, in Clearfil 40% phosphoric acid was used and in Concise, 50% phosphoric acid and 37% citric acid were used as etchant for 1 minute. After the copper band which is 5 mm in diameter and 5 mm in height was fixed on the prepared surface and each filling material was inserted into the copper band, the hooking loop was inserted into filled material in the copper band before setting to make it easily that the load is applied on the specimen. After all specimens were immersed in water at $37^{\circ}C$ for 1 week, this specimen was placed on the load cell of tensile test apparatus, and specimen was pulled at the cross-head speed of 0.8 mm per minute. The following results were obtained 1) In glass ionomer cement, the bond strength obtained by 37% citric acid was higher than one obtained by 50% phosphoric acid in enamel and dentin surfaces. The bond strength obtained in non-etched surface was much less than one by etchants in enamel and dentin surface. 2) In Clearfil, the bond strength obtained by 40% phosphoric acid was 4 times more than one obtained by non etch ant. 3) In Concise, the bond strength obtained by 50% phosphoric acid was almost same as one obtained by 37% citric acid, and the bond strength obtained by non etch ant was much less than one obtained by etchants.

  • PDF

흰쥐의 악골에 동종 이식한 태아 치아싹의 장기간 발육 (THE LONG-TERM GROWTH OF HOMOGENEOUS EMBRYO TOOTH GERM TRANSPLANTED INTO THE MAXILLA OF A RAT)

  • 고동현;정한성;김성오;이제호;최형준;최병재
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.53-61
    • /
    • 2007
  • 치아우식증이나 치주질환으로 치아를 상실한 경우 여러 가지 방법으로 수복 치료할 수 있으나 그 중에서 임플란트와 치아 이식에 대한 관심이 높아지고 있다. 최근에는 치아 이식에 대한 성공률을 높이기 위해서 치아를 형성시키고 발육시키는 과정에 관한 많은 연구가 이루어지고 있다. 치아싹 이식은 생체 내와 생체 외에서 연구되고 있고, 생체 내 이식은 쥐와 생쥐, 고양이, 개 등 여러 동물에서 시행되고 있다. 이러한 생체 내 이식은 대부분 구강 외에서 시행되고 있으며 구강 내 이식에 대한 연구는 드물다. 본 연구는 악골 내에 이식한 치아싹이 발육되고 석회화되는지 관찰하기 위하여 성숙한 흰쥐의 상악 제 1 구치를 발치하고 그 발치와에 임신 13.5일 된 태아쥐에서 모상기의 하악 제 1 구치의 치아싹을 이식하고 2, 6 개월 후 희생하여 방사선학적 그리고 조직학적으로 관찰하여 다음과 같은 결과를 얻었다. 12 개월과 6개월 동안 악골 내에 이식한 치아싹은 석회화된 치아 조직이 형성 되었고 치아 조직에서 상아질과 백악질, 치수 조직이 관찰되었으며 법랑질 공간 주변은 상피로 둘러싸여 있었다. 2. 6개월 동안 구강 상피 하방에 위치한 치아 조직은 상피로 둘러싸여 있었고 주위에 치주인대 및 결합조직이 관찰되었다. 3. 이식한 시간이 경과함에 따라 치아 형성이 진전되었으나 치아 조직은 크기가 작았고 형태학적으로 완전하지 못하였다.

  • PDF

치아회분(齒牙灰粉)과 도재복합(陶材複合) 매식체(埋植體)의 물리적(物理的) 성질(性質) 및 세포배양(細胞培養)에 의(依)한 조직친화성(組織親和性)에 관(關)한 연구(硏究) (A Study on the Physical Properties and Cytotoxicity of Tooth Ash and Dental Procelain)

  • 호기영
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.51-68
    • /
    • 1984
  • The purpose of this study is primarily to test the use value of tooth ash as an alternative material of the synthetic hydroxyapatite. For this purpose the author performed the experimental study to investigate the phsyical properties of sintered tooth ash and its histocompatibility in vitro. The tooth ash was made by incinerating procedure at $650^{\circ}C,\;750^{\circ}C,\;850^{\circ}C,\;950^{\circ}C\;and\;1050^{\circ}C$ respectively. The composition of tooth ash was analyzed and X-ray diffraction was done. The experimental specimens were molded to the cylinderical form 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$, which were divided into two groups; the one is sintered tooth ash at $1100^{\circ}C$ and the other is fired mixture of tooth ash and dental porcelain mixed to the weight ratio of 4:6, 5:5, 6:4 and 7:3. The physical propoerties of the sintered specimens were examined and their microstructure was observed under the Scanning Electron Microscope. The results obtained were as followings: 1. The difference of the tooth ash composition depending on incinerating temperature was of no significance, but the $CO_2$ disappeared from $950^{\circ}C$. 2. X-ray diffraction showed the tooth ash was mainly composed of hydroxyapatite and a small amount of - white lockite. But phase transformation was not disclosed. 3. The microstructure of the sintered specimens of the ashed tooth powder was of no difference in the structure and grain size accompanying the ashed temperature, but sintering ability seemed to be the best in the specimen incinerated at $950^{\circ}C$. 4. There was good wettability in the mixed sintered specimens of the ashed tooth powder and the porcelain powder. 5. The compressive strength of the sintered specimens of the tooth ash incinerated at $950^{\circ}C$ was the highest with $589.75kg/cm^2$ and the porosity and the absorption were the lowest as well. 6. The mixed sintered specimens of the tooth ash and porcelain powder was good in the physical properties in the case of mixed weight ratio of 6:4. 7. The animal fibroblast cultures with porcelain showed increase in the cell number, whereas the tooth ash showed a small degree of growth inhibition. But the difference of cell multiplication efficiency between control cultures and test cultures with tooth ash was not observed.

  • PDF