• Title/Summary/Keyword: Tool Tip

Search Result 216, Processing Time 0.027 seconds

Performance Evaluation of Conical Picks for Roadheader in Copper Mines (구리광산에 적용된 부분단면굴착기용 국산 코니컬 픽커터의 성능평가 연구)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Chulho;Lee, Gyu-Phil;Bae, Young Hwan;Ha, Tae-Wook
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.496-504
    • /
    • 2015
  • Roadheader that excavates ground using pick cutters installed on the cutting head is one of the partial-face machines. A conical cutter among pick cutters is excavation tool decreasing the loss of cutter using tungsten carbide insert at the tip of the cutter and it has been widely used in the roadheaders. In this study, durability performance for three kinds of conical cutters was evaluated in copper mines composed of Manto and conglomerate. After field test, the visual inspection as well as the weight loss measurement of pick cutters was carried out to investigate the damage of pick cutters. In addition, CT scan and SEM were performed to check whether or not crack and apertures in pick cutters. As results, the conical cutter with hardfacing was evaluated as having the best durability performance and it was unable to find cracks in all cutters investigated.

Polyurethane Foam Template for Simple Design of Digital Island Flap (폴리우레탄 폼 드레싱재료를 이용한 간단한 손가락 섬피판 디자인)

  • Kim, Nam-Joong;Choi, Hwan-Jun;Kim, Jun-Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Various techniques have been attempted for design of the flaps. However, there are some disadvantages. They have thin, pliable, and two dimensional methods. The aim of this study is to report usefulness of polyurethane foam dressing materials for three dimensional design of the digital island flap. Methods: From June of 2007 to september of 2008, 10 patients received digital island flap surgery for soft tissue defect of the finger. After minimal debridement of the wound, size and shape of the defect were measured using polyurethane foam. We used Medifoam-$5^{(R)}$ And then, designed this inset the wound. The flap was designed on the donor site with a arterial pedicle as the central axis according to size and shape. A full thickness skin graft from the groin is applied on the flap donor defect and secured with a tieover bolster dressing. Results: Reviewing sizes of the flaps, the length and width of flaps ranged from 1.5 to 3.3 cm and 1.0 to 2.5 cm. The PACS(Picture Archiving Communication System) program allows identification of the donor depth of finger. The distance for the soft tissue ranged from 4.3 mm to 6.7 mm. Mean depth of donor site was 5.3${\pm}$0.6 mm. Also, the thickness of Medifoam-$5^{(R)}$ ranged nearly 5 mm. On flap insetting, full-thickness skin graft was necessary. We did not experience any problems in the recipient site size either, regardless of the extended flaps. Conclusion: Polyurethane foam has many advantages over the more conventional templates. Refinements in flap design and surgical technique resulted in favorable functional and cosmetic results. Especially, for beginner, Polyurethane foam dressing material is a simple and safe tool and therefore is an excellent choice for design of the island flap.

  • PDF

Aerodynamic Shape Optimization of Helicopter Rotor Blades in Hover Using a Continuous Adjoint Method on Unstructured Meshes (비정렬 격자계에서 연속 Adjoint 방법을 이용한 헬리콥터 로터 블레이드의 제자리 비행 공력 형상 최적설계)

  • Lee, S.-W.;Kwon, O.-J.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • An aerodynamic shape optimization technique has been developed for helicopter rotor blades in hover based on a continuous adjoint method on unstructured meshes. The Euler flow solver and the continuous adjoint sensitivity analysis were formulated on the rotating frame of reference for hovering rotor blades. In order to handle the repeated evaluation of the design cycle efficiently, the flow and adjoint solvers were parallelized using a domain decomposition strategy. A solution-adaptive mesh refinement technique was adopted for the accurate capturing of the tip vortex. Applications were made for the aerodynamic shape optimization of Caradonna-Tung rotor blades and UH60 rotor blades in hover. The results showed that the present method is an effective tool to determine optimum aerodynamic shapes of rotor blades requiring less torque while maintaining the desired thrust level.

Germ Cell Development During Spermatogenesis and Taxonomic Values in Mature sperm Morphology in Male Argopecten irradians irradians (Pteriomorphia: Pectinidae) in Southern Korea

  • Kim, Jin-Hee;Chung, Jae-Seung;Park, Young-Je
    • The Korean Journal of Malacology
    • /
    • v.28 no.1
    • /
    • pp.55-64
    • /
    • 2012
  • Ultrastructural studies of germ cell development during spermatogenesis and taxonomic values in mature sperm morphology of Argopecten irradians irradians were investigated by transmission electron microscopic observations. In the early stage of spermatid during spermiogenesis, a few granules and proacrosomal granules are formed by the Golgi complex. In the late stage of spermatid during spermiogenesis, a proacrosomal vesicle becomes an acrosomal vesicle in the acrosome through spermiogenesis. The sperm is approximately $ 45-48{\mu}m$ in length including a jar-shaped sperm nucleus (about $1.45{\mu}m$ long), an acrosome (about $0.34{\mu}m$ long) and tail flagellum. The axoneme of the sperm tail shows a 9+2 structure. As one of common characteristics of mature sperm morphologies in Pectinidae species in subclass Pteriomorphia, mature spermatozoon consists of the cone-shaped acrosomal vesicle and subacrosomal material on the invaginated jar-shaped nucleus. The acrosomal vesicle of this species is composed of electron high dense opaque part (material) from the base to the tip, as have seen in the species in the subclass Pteriomorphia. Exceptionally, five mitochondria are found in the sperm midpiece of this species, unlike four in most species of Pectinidae in subclass Pteriomorphia. However, the acrosomal vesicle of spermatozoa of A. irradians irradians resemble to those of other investigated Pectinidae species in subclass Pteriomorphia. Therefore, we can use sperm morphology as a tool in the resolution of taxonomic relationships within the Pectinidae species. These morphological charateristics of acrosomal vesicle belong to the family Pectinidae in the subclass Pteriomorphia.

Smart sensors for monitoring crack growth under fatigue loading conditions

  • Giurgiutiu, Victor;Xu, Buli;Chao, Yuh;Liu, Shu;Gaddam, Rishi
    • Smart Structures and Systems
    • /
    • v.2 no.2
    • /
    • pp.101-113
    • /
    • 2006
  • Structural health monitoring results obtained with the electro-mechanical (E/M) impedance techniqueand Lamb wave transmission methods during fatigue crack propagation of an Arcan specimen instrumented with piezoelectric wafer active sensors (PWAS) are presented. The specimen was subjected in mixed-mode fatigue loading and a crack was propagated in stages. At each stage, an image of the crack and the location of the crack tip were recorded and the PWAS readings were taken. Hence, the crack-growth in the specimen could be correlated with the PWAS readings. The E/M impedance signature was recorded in the 100 - 500 kHz frequency range. The Lamb-wave transmission method used the pitch-catch approach with a 3-count sine tone burst of 474 kHz transmitted and received between various PWAS pairs. Fatigue loading was applied to initiate and propagate the crack damage of controlled magnitude. As damage progressed, the E/M impedance signatures and the waveforms received by receivers were recorded at predetermined intervals and compared. Data analysis indicated that both the E/M impedance signatures and the Lamb-wave transmission signatures are modified by the crack progression. Damage index values were observed to increase as the crack damage increases. These experiments demonstrated that the use of PWAS in conjunction with the E/M impedance and the Lamb-wave transmission is a potentially powerful tool for crack damage detection and monitoring in structural elements.

A Comparison of the Crack Plane Equilibrium Model for Elastic-Plastic Fracture Analysis with the Irwin's Plastic Zone Corrected LEFM (탄소성 파괴해석을 위한 크랙 평면 평형모형과 항복 선형 파괴역학과의 비교에 관한 연구)

  • Lee, Kyu-Yong;Smith, F.W.
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.30-36
    • /
    • 1984
  • It is well known that the application of linear elastic fracture mechanics is inadequate to solve the large deformation fracture failures which occurr in ductile manner because of the large scale yielding due to the severe stress concentration in the region adjacent to the crack tip. The authors have been evolved a fracture model, the crack plane equilibrium model, for this kinds of elastic-plastic fracture problems in the previous report. In this report, the crack plane equilibrium model was compared with the Irwin's plastic zone corrected linear elastic fracture mechanics through theoretical comparisons and experimental results to examine the validity of the crack plane equilibrium model as an available tool for nonlinear fracture analysis. Through this study, the main results were reached as follows; Irwin's plastic zone corrected linear elastic fracture mechanics could be applicable only for small scale yielding problems as expected while the crack plane equilibrium model valid as a fracture model for large deformation fracture failure. However, the followings should be considered for the more precise evaluations of CPE model; 1) It is necessary to test more specimens which contain small cracks in the range of 2a/W<0.1. 2) It is important to detect the crack initiation point during the fracture test for determining an accurate fracture load. 3) Effects of specimen thickness in the fracture process zone should be examined.

  • PDF

Development of the Fixed Slab Analogy Device for the Measurement of Stress Intensity Factor (응력확대계수 측정용 고정 슬랩상사 장치의 개발)

  • 정진석;최선호;황재석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.1999-2010
    • /
    • 1992
  • The fixed slab analogy device which can measure stress intensity factors(S.I.F) experimentally by slab analogy theory is developed in this paper. The margin of errors resulted from the new testing apparatus are between 0.02% and 8.25%. Therefore, it is assured that this one can be effectively used for the more accurate measurement of S.I.F.( $k_{I}$, $k_{I I}$) than conventional apparatus. The pitch of master grating used in this experiment is 0.1mm It is known that the ratio of the distance from crack tip to the crack length on obtaining the accurate stress intensity factor is between 0.4 and 0.7. The optimum curvature radius of slab is about 125mm. The thickness of slab(plate) used in the fixed slab analogy device is 0.05mm(P.V.C. ; E = 64 MN/ $m^{2}$, .nu.=0.38), which is proved to be suitable for the test. The optimum material for the frame(slab`s external boundary) is a alloy tool steel(SKS 5) plate and its thickness is 1mm. In this research, the rigid cracks are directly bonded to the slab surface by cyanoacrylate adhesive for the easiness of slab making and conformity to the practical crack figure. The material of rigid crack is thin steel plate. It is expected that the developed method can be used effectively for the analysis of $k_{I}$ and $k_{I I}$ of arbitrary shaped or distributed cracks.cks.

IN-LINE NIR SPECTROSCOPY AS A TOOL FOR THE CONTROL OF FERMENTATION PROCESSES IN THE FERMENTED MEATS INDUSTRY

  • Tamburini, Elena;Vaccari, Giuseppe;Tosi, Simona;Trilli, Antonio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3104-3104
    • /
    • 2001
  • The research described here was undertaken with the aim of monitoring, optimizing and ultimately controlling the production of heterofermentative microbes used as starters in the salami industry. The use of starter cultures in the fermented meats industry is a well-established technique used to shorten and standardize the ripening process, and to improve and control the organoleptic quality of the final product. Starter cultures are obtained by the submerged cultivation of suitable microorganisms in stirred, and sometimes aerated, fermenters where monitoring of key physiological parameters such as the concentration of biomass, substrates and metabolites suffers from the general lack of real-time measurement techniques applicable to aseptic processes. In this respect, the results of the present work are relevant to all submerged fermentation processes. Previous work on the application of on-line NIR spectroscopy to the lactic acid fermentation (Dosi et al. - Monreal NIR1995) had successfully used a system based on a measuring cell included in a circulation loop external to the fermenter. The fluid handling and sterility problems inherent in an external circulation system prompted us to explore the use of an in-line system where the NIR probe is immersed in the culture and is thus exposed to the hydrodynamic conditions of the stirred and aerated fluid. Aeration was expected to be a potential source of problems in view of the possible interference of air bubbles with the measurement device. The experimental set-up was based on an in-situ sterilizable NIR probe connected to the instrument by means of an optical fiber bundle. Preliminary work was carried out to identify and control potential interferences with the measurement, in particular the varying hydrodynamic conditions prevailing at the probe tip. We were successful in defining the operating conditions of the fermenter and the geometrical parameters of the probe (flow path, positioning, etc.) were the NIR readings were reliable and reproducible. The system thus defined was then used to construct and validate calibration curves for tile concentration of biomass, carbon source and major metabolites of two different microorganisms used as salami starters. Real-time measurement of such parameters coupled with the direct interfacing of the NIR instrument with the PC-based measurement and control system of the fermenter enabled the development of automated strategies for the interactive optimization of the starter production process.

  • PDF

AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF A CALCIUM HYDROXIDE PLUG TREATED WITH DENTIN BONDING AGENT (상아질 결합제로 처리된 수산화칼슘 plug의 근단부 폐쇄능에 관한 연구)

  • Kim, Pyung-Sik;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.187-201
    • /
    • 1996
  • The purpose of this study was to evaluate the sealing ability of a calcium hydroxide plug treated with a bonding agent. Ninety extracted human anterior teeth and premolars with single canal were used in this study. Crowns were removed. the canal's were instrumented. and the roots were randomly divided into three groups of 30 each. In control group. a single apical seat was prepared with #60 K file 1mm short of the apex and the root canal was obturated with Gutta-percha and Sealapex by the lateral condensation method. In experimental group 1 and group 2. to prepare an apical isthmus of 1mm in length. the first apical seat was prepared with a #45 K file 1mm short of the anatomical apex and with a #60 K file 2mm short for the second apical seat. Dry calcium hydroxide powders were packed in the apical isthmus with a hand plugger and #60 K file and then. the root canal was obturated with Gutta-percha and Seal apex by the lateral condensation method. In experimental group 2. following an application of the bonding agent to the plug. the root canal was obturated in the same way. The teeth of each group were immersed in a 2% methylene blue dye solution. for 1, 2, and 4 weeks. The distance from the tip of the cone to the deepest penetration was measured using the Tool maker's microscope. The results were as follows : 1. The teeth having the calcium hydroxide plug treated with the dentin bonding agent (experimental group 2) showed the lowest leakage with 1.4705mm and the control group without apical plug(no apical isthmus) showed the highest leakage with 3.1735mm. 2. The control group without apical plug showed higher leakage than experimental group 1 having the calcium hydroxide plug treated without the dentin bonding agent(p>0.05). 3. The control group without apical plug and experimental group 1, having the calcium hydroxide plug treated without the dentin bonding agent. showed higher leakage than experimental group 2. having the calcium hydroxide plug treated with the dentin bonding agent(p<0.001). 4. The immersion time had no significant effect on the degree of leakage. In conclusion, the results showed that the calcium hydroxide plug treated with the dentin bonding agent could decrease the microleakage from the root apex effectively.

  • PDF

Fabrication of silicon piezoresistive pressure sensor for a biomedical in-vivo measurements (생체 in-vivo 측정용 실리콘 압저항형 압력센서의 제조와 그 특성)

  • Bae, Hae-Jin;Son, Seung-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.148-155
    • /
    • 2001
  • A pressure sensor on the tip of a catheter which is utilized to measure the in-vivo pressure in a human body was fabricated and the characteristic of the pressure sensor as measured. To fit into a catheter with 1 mm caliber, samples of $150\;{\mu}m$(thickness) ${\times}$ (600, 700, 800, 900, 1000) ${\mu}m$(width) ${\times}2\;mm$(length) was fabricated. The thicker face with $450\;{\mu}m$ thickness of SDB wafer was made thin to $134\;{\mu}m$ thickness using KOH etchant and it made possible to fabricate sensor cell with the width shorter than 1 mm. Different to the whitstone bridge sensor, we formed one piezoresistor and one reference resistor in sensor. Therefore there are possibilities of reduction of the sensitivity, then by using the simulation tool ANSYS 5.5.1, the location and the type of the piezoresistor was optimized. Another piezoresistor type of sensor which contain one longitudinal and one transverse piezoresistor was fabricated at the same time, but the sensitivity was not improved very much. To get the output versus the pressure, a constant current source and a implementation amplifier was used. As a result, the maximum sensitivity of the sensor with one piezoresistor was $1.6\;{\mu}V/V/mmHg$.

  • PDF