• Title/Summary/Keyword: Toner particles

Search Result 26, Processing Time 0.033 seconds

Response Characteristics of Charged Particle Type Display (대전입자형 디스플레이의 응답특성)

  • Lee, Dong-Jin;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.169-173
    • /
    • 2009
  • We studied driving characteristics according to the ratio of mass and charging (m/q) value for charged toner particles with black and yellow color in charged particle type display panel. After biasing rectangle pulse to the transparency electrodes of putted panel with toner particles, its response time and contrast ratio are simultaneously measured using a laser as a optical source, photodiode as a detector and reflective system. As a results, contrast ratio is largest at the shortest response time region which is different to the particle because of m/q. We proposed relational equation for response time, m/q, cell gap and biasing voltage. It has not been studied and reported to analyze the relationship of response time, biasing voltage, lumping phenomena, cell gap, and contrast ratio for toner particle type display.

Effects of Surface-modification of Carbon Black on the Characteristics of Polymerized Toner (카본블랙의 표면개질이 중합토너의 특성에 미치는 영향)

  • Lee, Eun Ho;Kim, Dae Su
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.628-633
    • /
    • 2013
  • Carbon black was surface-modified to prepare styrene-based suspension polymerized toner with excellent carbon black dispersibility inside toner particles. Carbon black was oxidized first to introduce hydroxyl groups on the surfaces, then esterification between the hydroxyl groups and carboxyl groups of organic acids (oleic acid, palmitic acid, acrylic acid) was followed to obtain organically surface-modified carbon black. The surface-modification of carbon black was confirmed by FTIR. Apparent carbon black dispersibility in the monomer mixture of the binder resin was tested and the particle size of dispersed carbon black was measured by particle size analyzer. Optical micrographs showed that carbon black dispersibility inside toner particles was improved considerably when the carbon black surfacemodified with oleic acid was used. The polymerized toner prepared with the carbon black surface-modified with oleic acid showed ideal particle size and size distribution as a toner.

Dependence of contrast ratio on rib structure in flexible toner type EPD

  • Ryu, Gi-Seong;Lee, Chang-Bin;Han, Sang-Kwuon;Chun, Seung-Hee;Song, Chung-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.886-888
    • /
    • 2009
  • We fabricated flexible electronic paper display(EPD) by using toner particles on plastic (PC) substrate. We observed the relationship between contrast ratio and changes of rib structures. One is a fabrication of ribs on bottom substrate. The display with ribs on bottom substrate had higher contrast ratio about 46% than display with ribs on top substrate. The other is a change of density of rib. The less density of ribs fabricated, the higher the contrast ratio become.

  • PDF

The Control of Electrostatic Characteristics in Toner Type Paper-like Display

  • Lee, S.G.;Kwon, S.H.;Cho, W.K.;Song, M.B.;Kim, Y.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1158-1161
    • /
    • 2006
  • The toner type paper-like display (PLD) has been developed with two polymer particles having opposite polarity which is composed of polymer, colorant and external additives (nano-sized silica). Nano-sized silica with triboelectric charge was used for the charge control agent (CCA) and influenced on the electrostatic properties of the silica-coated polymer particles. The PLD cell using silica-coated particles (200 seconds) had shown a good white appearance and low driving voltage. The result could be explained in terms of the surface morphology and the cohesiveness depending on the silica coating time.

  • PDF

A Study on the PVA Particle Manufacturing for Polymerization Type Fine Toner (중합형 미세토너 합성을 위한 PVA입자 제조에 관한 연구)

  • 전재우;우화령;이난형;류원석;김삼수
    • Textile Coloration and Finishing
    • /
    • v.15 no.6
    • /
    • pp.8-17
    • /
    • 2003
  • In order to investigate the possibility of PVA particle as toner, PVA/PVAc particle was manufactured. Fine spherical PVAc particle with emulsifier SDS(sodium Dodecyl Sulfate) and initiator V-50(2,2'- azo bis(2-amidinopropane) dihydrochloride) was manufactured by emulsion polymerization. And then, the PVAc was carried with surface saponification. PVA/PVAc skin core structured particle was obtained under optimum saponification condition. PVA skin side in manufactured PVA/PVAc particles was dyed with 1:2 metal complex type C. I. Acid Yellow 235 and then the dyed PVA particles were observed with a optical microscope. Under given polymerization condition such as SDS concentration, $1.62\times{10}^{-2} \;mol/lH_2O$, V-50 concetration, $3.7\times{10}^{-3}\;mol/lH_2O$ and temperature $50^\circ{C}$ , the high molecular weight of PVAc with Pn 13,900 and PVA with Pn 3,400 was produced. The particle distribution of obtained PVAc microspheres was appeared highly at 60 and $100\mu{m}$, respectively.

Styrene-Butylacrylate Based Suspension Polymerized Toner Prepared Using PVA as a Suspending Agent (PVA를 현탁제로 사용하여 제조한 스타이렌-부틸아크릴레이트 기반 현탁중합토너)

  • Park, Solmon;Kim, Duk Eung;Byun, Jihyun;Yu, Jae Goang;Kim, Dae Su
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.212-217
    • /
    • 2010
  • In this study, suspension polymerized toners were prepared by using poly(vinyl alcohol)(PVA) as an organic suspending agent. Styrene and butylacrylate monomers were used simultaneously with carbon black to prepare microspherical polymerized toners with a narrow-particle size distribution. Preliminary particles without carbon black were polymerized first to optimize suspension polymerization conditions. The preliminary particles were prepared at various polymerization conditions and their characteristics were compared to each other to determine an optimized polymerization condition. The black polymerized toner prepared at the optimized polymerization condition showed reasonable particle size and shape, and good thermal and printing characteristics by showing its glass transition temperature at $53.6^{\circ}C$.

Effect of aging toner type particles using pulse waveform (Pulse waveform을 이용한 Toner type particles의 Aging 효과)

  • Oh, Yoo-Mi;Kim, Kyung-Soo;Kim, Sung-Woon;Youn, Hae-Sang;Park, Sun-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.142-142
    • /
    • 2010
  • This research proposed an advanced Electronic bead (EB) using MMA (Methy methacrylate) and CCA (Charge Control Agent). In the first, this paper presents about measurement method and characterization analysis of EB and nano-silica with pulse waveform in aging. Furthermore; this work presents the positive and negative EB fabrication procedure. As the experimental results, the proposed EB with square waveform is very attractive to Electronic paper driving characterization.

  • PDF

Interfacial Electric Property of PVA/PVAc Particles (PVA/PVAc 입자의 계면 전기적 성질)

  • Lee, Ha-Na;Lee, Jae-Woong;Kim, Ji-Young;Lee, Won-Chul;Kim, Sam-Soo
    • Textile Coloration and Finishing
    • /
    • v.20 no.6
    • /
    • pp.8-17
    • /
    • 2008
  • Poly (vinyl acetate) (PVAc) was used as a precursor of PVA/PVAc (skin/core) bicomponent. In order to investigate the possibility of PVA particles for electrical applications, PVA/PVAc particles were produced with an emulsifier, SDS (Sodium Dodecyl Sulfate) and an initiator, V-50 (2,2'-azobis(2-amidinopropane)digydrochloride). In this study, we investigated the electrical property of PVA/PVAc (skin/core) particles. The hydroxyl group of the PVA/PVAc (skin./core) was confirmed by the analysis of PVAc and PVA/PVAc (skin/core) using Fourier Transform Infrared Spectroscopy (FT-IR). The zeta-potential of the PVA/PVAc (skin/core) and PVAc has similarity; however, charge control agent (CCA) treated PVA/PVAc (skin/core) particles has lower zeta-potential than untreated PVA/PVAc particles. The zeta-potential (negative values) of the PVA/PVAc (skin/core) were enhanced in proportion to the increased concentration of CCA.

Development of Reflective Paper-like Display with Triboelectrically Charged-polymer Particles

  • Cho, Won-Ki;Kwon, Soon-Hyung;Lee, Sung-Guk;Kim, Nam-Jin;Ryu, Byung-Gil;Song, Moon-Bong
    • Journal of Information Display
    • /
    • v.6 no.3
    • /
    • pp.30-35
    • /
    • 2005
  • We have developed a paper-like display using polymer particles charged triboelectrically. By using a toner-type display with a simple structure, we continued that polymer particle movement is controlled by only a voltage difference between scan and data electrode. We fabricated a diagonal 2.4 inch panel on the glass substrate and successfully produced an image by the passive driving method with operating voltages of about ${\pm}$ 120 V. The contrast ratio was 4:1.

Control of the Motions of Particles in Microfluidic System (미세유동시스템 내에서의 입자의 위치제어 연구)

  • Heo, Yun Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.6
    • /
    • pp.521-525
    • /
    • 2014
  • Circulating tumor cells (CTCs) in the bloodstream of cancer patients provide an accessible source for detection, characterization, and monitoring of nonhematological cancers. The effectiveness of the CTC-Chip for the isolation of ovarian cancer cells was demonstrated by adapting the herringbone-chip (HB-Chip). The motions of the particles on the HB chip were simulated by a unique combination of buoyant, gravitational forces, and helical flows with a computational modeling. The motions of cells are demonstrated by applying polystylene bead and ovarian cancer cells into the microfabricated HB-Chip. The experimental results from beads and cells are well accordance with the simulated ones, as previously reported by Toner group. Thus, I expect that these modeling and experimental skills will play key roles in the clinical applications on CTC isolation as well as the basic research on characterization of CTCs under flow.