Estimation of the OD Traffic Intensities in Dynamic Routing Network: Routing-Independent Tomography

  • Kim, Seung-Gu
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.3
    • /
    • pp.795-804
    • /
    • 2003
  • In this article, a tomography for the estimation of the origin-destination(OD) traffic intensities in dynamic routing network is considered. Vardi(1996)'s approach based on fixed route is not directly applicable to dynamic routing protocols, which arises from the fact that we cannot access the route at every observation time. While it uses link-wise traffics as the observations, the proposed method considers the triple of ingress/outgress/relayed traffics data at each node so that we can transform the problem into a routing-independent tomography. An EM algorithm for implementation and some simulated experiments are provided.

Preoperative N Staging of Gastric Cancer by Stomach Protocol Computed Tomography

  • Kim, Se Hoon;Kim, Jeong Jae;Lee, Jeong Sub;Kim, Seung Hyoung;Kim, Bong Soo;Maeng, Young Hee;Hyun, Chang Lim;Kim, Min Jeong;Jeong, In Ho
    • Journal of Gastric Cancer
    • /
    • v.13 no.3
    • /
    • pp.149-156
    • /
    • 2013
  • Purpose: Clinical stage of gastric cancer is currently assessed by computed tomography. Accurate clinical staging is important for the tailoring of therapy. This study evaluated the accuracy of clinical N staging using stomach protocol computed tomography. Materials and Methods: Between March 2004 and November 2012, 171 patients with gastric cancer underwent preoperative stomach protocol computed tomography (Jeju National University Hospital; Jeju, Korea). Their demographic and clinical characteristics were reviewed retrospectively. Two radiologists evaluated cN staging using axial and coronal computed tomography images, and cN stage was matched with pathologic results. The diagnostic accuracy of stomach protocol computed tomography for clinical N staging and clinical characteristics associated with diagnostic accuracy were evaluated. Results: The overall accuracy of stomach protocol computed tomography for cN staging was 63.2%. Computed tomography images of slice thickness 3.0 mm had a sensitivity of 60.0%; a specificity of 89.6%; an accuracy of 78.4%; and a positive predictive value of 78.0% in detecting lymph node metastases. Underestimation of cN stage was associated with larger tumor size (P<0.001), undifferentiated type (P=0.003), diffuse type (P=0.020), more advanced pathologic stage (P<0.001), and larger numbers of harvested and metastatic lymph nodes (P<0.001 each). Tumor differentiation was an independent factor affecting underestimation by computed tomography (P=0.045). Conclusions: Computed tomography with a size criterion of 8 mm is highly specific but relatively insensitive in detecting nodal metastases. Physicians should keep in mind that computed tomography may not be an appropriate tool to detect nodal metastases for choosing appropriate treatment.

The Efficacy of Detecting a Sentinel Lymph Node through Positron Emission Tomography/Computed Tomography (근골격계 악성 종양 환자의 림프절 전이 발견을 위한 양전자 방출 컴퓨터 단층 촬영기(Positron Emission Tomography/Computed Tomography)의 유용성)

  • Shin, Duk-Seop;Na, Ho Dong;Park, Jae Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.509-518
    • /
    • 2019
  • Purpose: Lymph node metastasis is a very important prognostic factor for all skin cancers and some sarcomas. A sentinel lymph node (SLN) biopsy is the most useful technique for identifying SLNs. Recently, a new generation of diagnostic tools, such as single photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) enabled the detection of SLNs. This study compared the efficacy of PET/CT for detecting lymph node metastases with a SLN biopsy in a single medical center. Materials and Methods: From 2008 to 2018, 72 skin cancers of sarcoma patients diagnosed with some lymph node involvement in a whole body PET/CT reading were assessed. Patients suspected of lymph node metastasis were sent to biopsy and those suspected to be reactive lesions were observed. The analysis was performed retrospectively using the medical records, clinical information, PET/CT readings, and pathology results. Results: The age of patients ranged from 14 to 88 years and the mean follow-up period was 2.4 years. Twenty-two patients were suspected of a lymph node metastasis and confirmed. The sensitivity, specificity, positive predictive value and negative predictive value of PET/CT images in sarcoma and non-sarcoma tumors were increased significantly when the expert's findings were considered together. Conclusion: PET/CT is effective in detecting lymph node metastases.

Development of a GUI Crosswell Seismic Tomography Software on Linux (리눅스용 GUI 시추공 탄성파 토모그래피 프로그램 개발)

  • Sheen Dong-Hoon;Ko Kwang Beom;Park Jae-Woo;Ji Jun;Lee Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.150-156
    • /
    • 2002
  • In this study, a software for crosswell seismic tomography is developed. The software consists of first arrival picking and adjusting module, crosswell traveltime tomography module, and imaging module. This software allows saying the picked first arrival times into the header of seismic data, and using this data directly to the input of crosswell seismic tomography. With an imaging module, velocity structures and ray path can be imaged directly from the output of the tomography module. Because it is developed on the basis of the SU under the Linux and the GUI environment for user, this software can be carried out directly the first arrival picking, inversion and tomogram for crosswell tomography data in the field. Therefore, this software can be improved the applicability of site investigation by tomography method.

Nondestructive Contactless Sensing of Concrete Structures using Air-coupled Sensors

  • Shin, Sung-Woo;Hall, Kerry S.;Popovics, John S.
    • International Journal of Safety
    • /
    • v.7 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • Recent developments in contactless, air-coupled sensing of seismic and ultrasonic waves in concrete structures are presented. Contactless sensing allows for rapid, efficient and consistent data collection over a large volume of material. Two inspection applications are discussed: air-coupled impact-echo scanning of concrete structures using seismically generated waves, and air-coupled imaging of internal damages in concrete using ultrasonic tomography. The first application aims to locate and characterize shallow delamination defects within concrete bridge decks. Impact-echo method is applied to scan defected concrete slabs using air coupled sensors. Next, efforts to apply air-coupled ultrasonic tomography to concrete damage imaging are discussed. Preliminary results are presented for air-coupled ultrasonic tomography applied to solid elements to locate internal defects. The results demonstrate that, with continued development, air-coupled ultrasonic tomography may provide improved evaluation of unseen material defects within structures.

Multiple intraosseous cervical pneumatocysts: A case report of a rare incidental finding on cone-beam computed tomography

  • Jadhav, Aniket B.;Sarah, Sangeetha Gajendran;Cederberg, Robert;Wagh, Aditya;Kiat-amnuay, Sudarat
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.223-226
    • /
    • 2018
  • This report presents a case of cervical pneumatocysts as an incidental finding on cone-beam computed tomography. Pneumatocysts are gas-containing lesions of unknown etiology. They usually present in the ilium or sacrum, adjacent to the sacroiliac joint. In the literature, 21 case reports have described cervical pneumatocysts. Cervical pneumatocysts should be differentiated from other lesions, such as osteomyelitis, osteonecrosis, and neoplasms, as well as post-traumatic and post-surgical cases. Computed tomography, cone-beam computed tomography, and magnetic resonance imaging are appropriate tools to diagnose cervical pneumatocysts.

Reconstruction of Density Distribution for Unsteady and Asymmetric Flow Using Three-dimensional Digital Speckle Tomography (3차원 디지털 스펙클 토모그래피를 이용한 비정상 비대칭 유동의 밀도 분포 재건)

  • Kim, Yong-Jae;Ko, Han-Seo;Baek, Seung-Hwan
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.21-24
    • /
    • 2006
  • Transient and asymmetric density distributions have been investigated by a digital speckle tomography with a novel integration method. Multiple CCD images captured movements of speckles in three angles of view simultaneously because the flows were asymmetric and unsteady. The speckle movements which have been formed by a ground glass between no flow and downward butane flow from an elliptical nozzle have been calculated by a cross-correlation tracking method so that those distances can be transferred to deflection angles of laser rays for density gradients. A novel integration method has been developed to obtain projection data from the deflection angles for the speckle tomography. The unsteady density fields have been reconstructed from the accurate projection values by the digital speckle tomography method using the developed integration method.

  • PDF

Nonlinear Traveltime Tomography Method Using Fresnel Zone (Fresnel 영역을 고려한 비선헝 주시 토모그래피)

  • Cho, Chang-Soo;Ji, Jun;Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.43-48
    • /
    • 1998
  • Recently seismic tomography has been widely used to visualize subsurface structure for resource explorations and construction site evaluation. We studied a way to include fresnel zone concept in the conventional ray-based traveltime tomography. The algorithm developed uses the same order of computing time as the conventional traveltime to mography but incorporates the rigorous wavepath concept of wave-equation tomography. Some experiments to synthetic and real data show reasonable results compared to conventional ray-based traveltime tomography.

  • PDF