• Title/Summary/Keyword: Tomography, emission-computed, single-photon

Search Result 155, Processing Time 0.025 seconds

Imaging Human Structures

  • Kim Byung-Tae;Choi Yong;Mun Joung Hwan;Lee Dae-Weon;Kim Sung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.283-294
    • /
    • 2005
  • The Center for Imaging Human Structures (CIH) was established in December 2002 to develop new diagnostic imaging techniques and to make them available to the greater community of biomedical and clinical researchers at Sungkyunkwan University. CIH has been involved in 5 specific activities to provide solutions for early diagnosis and improved treatment of human diseases. The five area goals include: 1) development of a digital mammography system with computer aided diagnosis (CAD); 2) development of digital radiological imaging techniques; 3) development of unified medical solutions using 3D image fusion; 4) development of multi-purpose digital endoscopy; and, 5) evaluation of new imaging systems for clinical application

Monte Carlo Simulation Codes for Nuclear Medicine Imaging (핵의학 영상연구를 위한 몬테칼로 모사코드)

  • Chung, Yang Hyun;Beak, Cheal-Ha;Lee, Seung-Jae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • Monte Carlo simulation methods are especially useful in studying a variety of problems difficult to calculate by experimental or analytical approaches. Nowadays, they are extensively applied to simulate nuclear medicine instrumentations such as single photon emission computed tomography (SPECT) and positron emission tomography (PET) for assisting system design and optimizing imaging and processing protocols. The goal of this paper is to address the practical issues, a potential user of Monte Carlo simulations for nuclear medicine can encounter, to help them to choose a code. This review introduces the different types of Monte Carlo codes currently available for nuclear medicine, comments main features and properties for a code to be proper for a given purpose, and discusses current research trends in Monte Carlo codes.

The segmentation system for the anatomical analysis and diagnosis simulation of multi-modality brain image (다중 모달리티 뇌 영상의 해부학적 분석 및 진단 시뮬레이션을 위한 영상분할 시스템)

  • 윤현주;이정민;김명희
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2004.05a
    • /
    • pp.118-122
    • /
    • 2004
  • 본 논문에서는 인체의 머리 부분을 촬영한 의료 영상에서 뇌 영역만을 분할하는 방법에 대해 제시하고자 한다. 뇌의 해부학적 구조 및 기능적 이상 부위를 파악할 경우에 영상 내에 함께 보여지는 두개골과 뇌척수액 등을 제외한 대뇌피질 영역을 분할하면 보다 효과적인 정보 분석 및 진단이 가능하게 된다. 본 시스템에서는 3단계 알고리즘을 제시한다. 첫 번째 단계에서는 영상 내에 존재하는 잡음을 제거하기 위한 필터링이고, 두 번째 단계에서는 필터링된 결과에 대한 영상분할을 수행하는 것이다 이 때 정확한 결과 도출을 위하여 사용자의 인터렉션이 들어가게 된다. 세번째 단계에서는 형태학적 방법을 이용하여 분할 결과를 보완한다. 본 연구를 위한 실험에는 자기 공명 촬영 영상(MRI: Magnetic Resonance Imaging), 단일 광전자 방출 단층 촬영영상(SPECT: Single Photon Emission Computed Tomography), 양전자 방출 단층 촬영영상(PET: Positron Emission Tomography) 등을 사용하였다. 본 시스템에서는 다양한 모달리티의 뇌 영상에서 대뇌피질 부분을 정확하게 영상 분할함으로써 뇌의 구조적 이상을 판단하기 위한 해부학적 정보 분석을 가능케 하고 있다. 뿐만 아니라 뇌 질환에 대한 정확한 진단 시뮬레이션도 가능하게 하고자 한다.

  • PDF

Nuclear Imaging in Epilepsy (간질에서의 핵의학 영상)

  • Chun, Kyung-Ah
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.97-101
    • /
    • 2007
  • Correct localization of epileptogenic zone is important for the successful epilepsy surgery. Both ictal perfusion single photon emission computed tomography (SPECT) and interictal F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) can provide useful information in the presurgical localization of intractable partial epilepsy. These imaging modalities have excellent diagnostic sensitivity in medial temporal lobe epilepsy and provide good presurgical information in neocortical epilepsy. Also provide functional information about cellular functions to better understand the neurobiology of epilepsy and to better define the ictal onset zone, symptomatogenic zone, propagation pathways, functional deficit zone and surround inhibition zones. Multimodality imaging and developments in analysis methods of ictal perfusion SPECT and new PET ligand other than FDG help to better define the localization.

Radiotracers for Functional Neuroimaging (기능성 신경영상화를 위한 방사성추적자)

  • Lee, Byung-Chul;Chi, Dae-Yoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.53-62
    • /
    • 2003
  • After the development of two major techniques - SPECT (Single Photon Emission Computed Tomography) and PET (Positron Emission Tomography) to image the human subjects in a three-dimensional direction in the 1980s, many radiotracers have been used for functional neuroimaging. Still it would be very important study to develop selective radiotracers for functional neuroimaging. New radiotracers will help to expand the knowledge of neurotransmitter systems and of the genetic contribution to receptor or transporter availability. Neurotransmitter depletion-restoration studies, the distribution of brain functions and their modulation by neurotransmitter system aid in better understanding and limiting the side effects of drugs used as well as newly developed. In audition, these radiotracers will be thus very useful to gain a better understanding in biochemical and pharmacological interactions in living human. This review mentions the introduction of radioligands for the functional neuroimaging. Although significant progress has been achieved in the development of new PET and SPECT ligands for in vivo imaging of those receptors and transporters, there are continuous needs of new diagnostic radioligands.

Clinical Application of SPECT and PET in CerebroVascular Disease (뇌혈관질환에서 SPECT와 PET의 임상적 응용)

  • Ra, Young-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • Single photon emission computed tomography(SPECT) and positron emission tomography(PET) are modern imaging techniques that allow for both qualitative and quantitative assessment of hemodynamic changes in cerebrovascular diseases. SPECT has been becoming an indispensable method to investigate regional cerebral blood flow because equipment and isotope are easily available in most general hospitals. Acetazolamide stress SPECT has also been proved to be useful to evaluate the cerebrovascular reserve of occlusive cerebrovascular diseases and to select surgical candidate. PET has gained wide spread clinical use in the evaluation of the hemodynamic and metabolic consequences of extracranial or intracranial arterial obstructive disease despite its complexity and limited availability. PET has been established as an invaluable tool in the pathophysilogy investigation of acute ischemic stroke. The potentials, limitations, and clinical applications of SPECT and PET in various cerebrovascular diseases will be discussed in this article with reviews of literatures.

The changes of cerebral blood flow by brain imaging algorithm in the Normal Brains : Analysis by Statistical Parametric Mapping (정상 뇌혈류 영상에서 재구성 알고리즘 적용에 따른 섭취율 차이 : 통계적 파라미터 지도를 사용한 분석)

  • Lee, Hyo-Yeong;Kim, Yun-Jin;Sin, Sung-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5311-5316
    • /
    • 2012
  • Single Photon Emission Computed tomography(SPECT) was performed on 13 healthy adults (average age: 39) to investigate the changes of cerebral blood flow according to brain imaging analysis algorithm. The acquired images were filtered and reconstructed through Filtered Back Projection (FBP) and Ordered Subset Expectation Maximization (OSEM). The brain distribution data of radiopharmaceuticals were compared using Statistical Parametric Mapping (SPM), and the changes of blood flow was expressed in Cluster. As a result, uptake rate was increased in Sub-gyral, Sub-Lobar, Extra-Nuclear, Limbic lobe and Cingulate Gyrus, while uptake rate was decreased in Middle frontal gyrus, Inferior Frontal Gyrus and Precentral Gyrus. The discriminable SPM was shown according to cerebral blood flows in Cluster by the reconstruction algorithm.

3D Reconstruction Using Segmentation of Myocardial SPECT Images (SPECT 심근영상의 영상분할을 이용한 3차원 재구성)

  • Jung, Jae-En;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.5-10
    • /
    • 2009
  • Myocardial imaging in SPECT (Single Photon Emission Computed tomography) scan of the gamma-ray emitting radiopharmaceuticals to patients after intravenous radiopharmaceuticals evenly spread in the heart region of interest by recording changes in the disease caused by a computer using the PSA test is to diagnose. Containing information on the functional myocardial perfusion imaging is a useful way to examine non-invasive heart disease, but the argument by noise and low resolution of the physical landscape that is difficult to give. For this paper, the level of myocardial imaging by using the three algorithms to split the video into 3-D implementation of the partitioned area to help you read the proposed plan. To solve the difficulty of reading level, interest in using the sheet set, partitioned area of the left ventricle was ranked the partitioned area was modeled as a 3-D images.

  • PDF

3D Reconstruction Using Segmentation of Myocardial SPECT (SPECT 심근영상의 영상분할을 이용한 3차원 재구성)

  • Jung, Jae-Eun;Lee, Jun-Haeng;Choi, Seok-Yoon;Lee, Sang-Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2240-2245
    • /
    • 2010
  • Myocardial imaging in SPECT (Single Photon Emission Computed tomography) scan of the gamma-ray emitting radiopharmaceuticals to patients after intravenous radiopharmaceuticals evenly spread in the heart region of interest by recording changes in the disease caused by a computer using the PSA test is to diagnose. Containing information on the functional myocardial perfusion imaging is a useful way to examine non-invasive heart disease, but the argument by noise and low resolution of the physical landscape that is difficult to give. For this paper, the level of myocardial imaging by using the three algorithms to split the video into 3-D implementation of the partitioned area to help you read the proposed plan. To solve the difficulty of reading level, interest in using the sheet set, partitioned area of the left ventricle was ranked the partitioned area was modeled as a 3-D images.

Optimization of block-matching and 3D filtering (BM3D) algorithm in brain SPECT imaging using fan beam collimator: Phantom study

  • Do, Yongho;Cho, Youngkwon;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3403-3414
    • /
    • 2022
  • The purpose of this study is to model and optimize the block-matching and 3D filtering (BM3D) algorithm and to evaluate its applicability in brain single-photon emission computed tomography (SPECT) images using a fan beam collimator. For quantitative evaluation of the noise level, the coefficient of variation (COV) and contrast-to-noise ratio (CNR) were used, and finally, a no-reference-based evaluation parameter was used for optimization of the BM3D algorithm in the brain SPECT images. As a result, optimized results were derived when the sigma values of the BM3D algorithm were 0.15, 0.2, and 0.25 in brain SPECT images acquired for 5, 10, and 15 s, respectively. In addition, when the sigma value of the optimized BM3D algorithm was applied, superior results were obtained compared with conventional filtering methods. In particular, we confirmed that the COV and CNR of the images obtained using the BM3D algorithm were improved by 2.40 and 2.33 times, respectively, compared with the original image. In conclusion, the usefulness of the optimized BM3D algorithm in brain SPECT images using a fan beam collimator has been proven, and based on the results, it is expected that its application in various nuclear medicine examinations will be possible.