• Title/Summary/Keyword: Tomography, emission computed

Search Result 379, Processing Time 0.032 seconds

Influence of Void on Performance of Industrial SPECT System (공정 내 기포가 산업용 SPECT의 성능에 미치는 영향)

  • Park, Jang Guen;Jung, Sung-Hee;Kim, Jong Bum;Moon, Jinho;Kim, Chan Hyeong
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Industrial single photon emission computed tomography (SPECT) is an useful technique to investigate the dynamic behavior of process flow. In the present study, to evaluate the influence of a void on the performance of industrial SPECT, industrial SPECT with various radioisotope sources and gas holdups was modeled by the Monte Carlo simulation. The results are very encouraging; that is, the void little influences the performance of industrial SPECT, which means that industrial SPECT could be a suitable tool to investigate the dynamic characteristics of the flow in a water-air phase process.

Synthetic Approach to 99mTc-labeled SPECT Radiotracers with Multi-nitroimidazoles for Hypoxia

  • Anh Thu Nguyen;Hee-Kwon Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Hypoxia, defined as the deficiency of oxygen, is a significant hallmark of cancers presenting in the majority of solid tumors. Detection of tumor hypoxia is essential in cancer diagnosis to prevent cancer progression, metastasis, and resistance to cancer therapies in clinical practices. Single-photon emission computed tomography (SPECT) is one of the methods studied and applied for hypoxia detection with the use of radiolabeled imaging agents in which 99mTc is the common radioisotope used for radiolabeling. Nitroimidazoles are the hypoxia-targeting moieties presenting in numerous 99mTc-radiolabeled imaging agents due to their bio-reducible ability in hypoxic environments. Recently, in addition to 99mTc-labeled radiopharmaceuticals containing one nitroimidazole unit, there has been considerable attention given to 99mTc-radiopharmaceuticals bearing two or more nitroimidazole units. This review summarizes the synthesis of hypoxia-targeting chelators and radiolabeling processes to produce these 99mTc-radiopharmaceuticals for SPECT imaging.

Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer (위암환자의 술 전 병기 결정에서 PET-CT의 유용성)

  • Park, Shin-Young;Bae, Jung-Min;Kim, Se-Won;Kim, Sang-Woon;Song, Sun-Kyo
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.110-116
    • /
    • 2009
  • Purpose: The aim of this study was to examine the usefulness of positron emission tomography (PET)-computed tomography (CT) in the pre-operative staging of gastric cancer. Materials and Methods: Between February 2006 and August 2008, PET-CT and CT were performed on 70 patients diagnosed with gastric cancer by gastrofiberscopic biopsy. The sensitivities, specificities, Positive predictive value (PPV), and negative predictive value (NPV) of PET-CT and CT imaging for the detection of gastric cancer TNM staging were compared. Results: The detection rates for the primary tumor were as follows: PET-CT, 81.4% (57/70); and CT, 42.9% (30/70). For both early gastric cancer (EGC) and advanced gastric cancer (AGC), PET-CT was more accurate than CT in detecting the lesions. As the size of the tumor exceeded 3 cm, the detection rate increased. The sensitivities, specificities, PPV, and NPV of PET-CT for lymph node staging were 55.6%, 81%, 86.2%, and 45.9%, while the sensitivities, specificities, PPV, and NPV of CT were 40.0%, 85.7%, 85.7% and 40%, respectively. One case of multiple liver metastasis and two cases of dual primary cancer (rectal and pancreatic cancers) were detected by PET-CT. PET-CT also had a higher detection rate for all histologic types of primary tumors. PET-CT was more accurate than CT in detecting primary gastric cancer lesions. The detection of nodal metastasis by PET-CT was similar to CT; small-sized tumors or EGC detection rates were not high. However, PET-CT provided additional information to detect distant metastases and dual primary cancers and reduced unnecessary laparotomies to detect peritoneal seeding or carcinomatosis. Conclusion: It would be useful to make a pre-operative diagnosis of gastric cancer and determine treatment if PET-CT were added to other routine pre-operative studies.

  • PDF

Metabolic impairment pattern analysis of the Alzheimer's disease (Alzheimer's Disease의 대사영상패턴 분석)

  • Juh, Ra-Hyeong;Lee, Chang-Uk;Chung, Yong-An;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.91-95
    • /
    • 2004
  • Several MRI studies have reported reductions in temporal lobe volumes in Alzheimer's disease (AD). Measures have been usually obtained with regions-of-interest (ROI) drawn manually on selected medial and lateral portions of the temporal lobes, with variable choices of anatomical borders across different studies. We used the automated voxel-based morphometry (VBM) approach to investigate gray matter abnormalities over the entire extension of the temporal lobe in 10AD patients (MM5E 22)and 22 healthy controls. Foci of significantly reduced gray matter volume in AD patients were detected in both medial and lateral temporal regions, most significantly in the right and left posterior parahippocarmpal gyri. At a more flexible statistical threshold (P<0.01, uncorrected for multiple comparisons), circumscribed foci of significant gray matter reduction were also detected in the right amygdala/enthorinal cortex, the anterior and posterior borders of the superior temporal gyrus bilaterally, and the anterior portion of the left middle temporal gyrus. These VBM results confirm previous findings of temporal lobe atrophic changes in AD, and suggest that these abnormalities may be confined to specific sites within that lobe, rather than showing a widespread distribution.

  • PDF

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FINDINGS IN ATTENTION DEFICIT- HYPERACTIVITY DISORDER (주의력결핍 ${\cdot}$ 과잉운동장애의 단일광자방출 전산화단층촬영 소견에 관한 연구)

  • Cho, Soo-Churl;Lee, Myung-Chul;Moon, Dae-Hyuk
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.1 no.1
    • /
    • pp.27-39
    • /
    • 1990
  • The neural mechanisms involved in attention deficit hyperactivity disorder are largely unknown. In order to investigate the neuroanatomical lesions of attention deficit hyperactivity disorders and their relationships with psychopathology, Single Photon Emission Computed Tomography(SPECT) using HMPAO was performed in 46 ADHDS and Yale Children's Inventory(YCI), Conners Parent Questionaire and DSM-III-R Questionaire for Disruptive Behavior Disorder were used to assess the psychopathology of ADHDS The results are summarized as follows; 1) 30.4% (14/46) of this series revealed decreased perfusion In SPECT. 2) Regions of hypoperfusion were seen in cerebral cortex(17.4%, 8/46), thalamus(13.0%, 6/46), deep gray matter(8.7%, 4/46), basal ganglia(6.5%, 3/46) and cerebellum(2.2%, 1/ 46). 3) The mean scores of the total YCI revealed significant difference between the two groups(SPECT abnormal versus normal group), and among the subscales, hyperactivity, language and fine-motor subscales showed significant differences between the two groups. Although the relationship between the abnormal findings and specific symptom clusters of ADHDS remains unclear, we can suggest that these abnormal findings could be associated with ADHD, and based on these findings, the ADHDS can be subclassified into two groups. This study can be said to reinforce the current conception of heterogeneity of ADHD.

  • PDF

SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FINDINGS IN TOURETTE'S AND CHRONIC MOTOR TIC DISORDER (뚜렛씨병과 만성틱장애의 단일광자방출전산화단층촬영 소견에 관한 연구)

  • Cho, Soo-Churl;Lee, Myung-Chul;Kim, Ja-Sung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.4 no.1
    • /
    • pp.68-78
    • /
    • 1993
  • The pathophysiology and neural mechanism involved in Tourette's and chronic motor tic disorder are highly controversial. In order to investigate the functional abnormalities of brain. In Tourette's and chronic motor tic disorder, 42 children with Tourette's and chronic motor disorder underwent single photon emission computed tomography(SPECT) using Tc-99m-HM-PAO. The results are summarized as follows : 1) 31.0% (13/42) of this series revealed perfusion defect in cerebral cortex. 2) 4.8% (2/42) revealed perfusion defect in basal ganglia. 3) 4.8(2/42) revealed perfusion defect in thalamus. 4) 16.7%(7/42) showed perfusion defect in cerebellum. 5) The frequency of abnormal perfusion showed no significant difference between tic with and without attention deficit hyperactivity disorder. 6) The frequency of abnormal perfusion showed no significant difference between Tourette's and chronic motor tic disorder. These findings support the hypothesis of a possible involvement of brain dysfunction in the production of Tourette's and chronic motor tic disorder, and quantification of blood flow and co-registration with magnetic resonance imaging will increase the validity of this study.

  • PDF

Regional Brain Perfusion before and after Treatment with Methylphenidate According to the MspI Polymorphism of the Alpha-2A Adrenergic Receptor Gene in Children with Attention-Deficit Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서 α-2A 아드레날린 수용체 유전자의 MspI 유전자 다형성에 따른 메칠페니데이트 치료 전후 뇌관류 비교)

  • Park, Subin;Bae, Jeong-Hoon;Kim, Jae-Won;Yang, Young-Hui;Oh, Seungmin;Hong, Soon-Beom;Park, Min-Heyon;Kim, Boong-Nyun;Shin, Min-Sup;Yoo, Hee-Jeong;Cho, Soo-Churl
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.24 no.1
    • /
    • pp.21-27
    • /
    • 2013
  • Objectives : Dysregulation of the central noradrenergic system may be involved in the pathophysiology of attention-deficit hyperactivity disorder (ADHD). The aim of this study was to examine the differences in pre- and post-treatment cerebral perfusion according to the MspI polymorphisms of the alpha-2A-adrenergic receptor gene (ADRA2A) in children with ADHD. Methods : Thirty seven drug-naive ADHD children (8.9+1.8 years old, M=32, F=5) were genotyped. Baseline single-photon emission computed tomography (SPECT) and clinical assessments were performed for ADHD children. After treatment with methylphenidate for eight weeks, SPECT and clinical assessment were repeated. Results : No differences in baseline clinical assessments or cerebral perfusion were observed according to the MspI genotype. However, after treatment, ADHD children with the G/G genotype at the MspI polymorphism showed hyperperfusion in the right cerebellar declive (p=.001, uncorrected) and hypoperfusion in the left lentiform nucleus and left cingulate gyrus (p<.001 and p=.001, uncorrected), compared to children without the G/G genotype. Conclusion : Although the results of this study should be interpreted cautiously, they suggest a possible role of the MspI polymorphisms of the ADRA2A gene in methylphenidate-induced changes in cerebral perfusion.

Spect-guidance to Reduce Radioactive Dose to Functioning Lung for Stage III Non-small Cell Lung Cancer

  • Wang, Zhong-Tang;Wei, Li-Li;Ding, Xiu-Ping;Sun, Ming-Ping;Sun, Hong-Fu;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1061-1065
    • /
    • 2013
  • Objective: To investigate the treatment effect of additional information obtained by single photon emission computed tomography (SPECT) lung perfusion imaging (LPI) in the radiotherapy planning process for patients with stage III non-small cell lung cancer (NSCLC). Methods: 39 patients with stage III NSCLC were enrolled. Gross tumor volume (GTV) was outlined by SPECT/CT images, SPECT-LPIs being used to define functional lung (FL) and non-functional lung (NFL) regions. Two sets of IMRT plans were designed to deliver 64Gy to PTV. One was a regular IMRT plan using CT images only (Plan 1), and the other was a corresponding IMRT plan using co-registered images (Plan 2). $FL_{Vx}$ (the % volume of functional lung receiving ${\geq}$x Gy) and $WL_{Vx}$ (% volume of whole lung to receive ${\geq}$x Gy) were compared by paired Student's t test. Kendalls correlation was used to analyze the factor (s) related with the FLV20 decrease. Results: Compared with plan 1, both $WL_{Vx}$ and $FL_{Vx}$ were decreased in plan 2. $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V30}$ and $WL_{V35}$ decreased 9.7%, 13.8%, 17.2%, 12.9%, 9.8% and 9.8%, and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ and $FL_{V35}$ decreased 10.8%, 14.6%, 17.3%, 14.5%, 14.5% and 10.5%. $FL_{Vx}$ decreased significantly compared with $WL_{Vx}$. There were significant differences in $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V3}$ and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ between plan 1 and plan 2 (P=0.002, 0.000, 0.000, 0.005, 0.027 and 0.002, 0.000, 0.000, 0.006, 0.010). According to Kendall correlation analysis, NFL had a negative relation with the percentage FLV20 decrease (r=-0.559, P<0.01), while the distance of PTV and NFL center had a significantly positive relation with the percentage of FLV20 decrease (r=0.768, P<0.01). Conclusion: Routine use of SPECT-LPI for patients undergoing radiotherapy planning for stage III NSCLC appears warranted.

Value of Bone Scintigraphy and Single Photon Emission Computed Tomography (SPECT) in Lumbar Facet Disease and Prediction of Short-term Outcome of Ultrasound Guided Medial Branch Block with Bone SPECT

  • Koh, Won-Uk;Kim, Sung-Hoon;Hwang, Bo-Young;Choi, Woo-Jong;Song, Jun-Gul;Suh, Jeong-Hun;Leem, Jeong-Gill;Shin, Jin-Woo
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2011
  • Background: Facet joint disease plays a major role in axial low-back pain. Few diagnostic tests and imaging methods for identifying this condition exist. Single photon emission computed tomography (SPECT) is reported that it has a high sensitivity and specificity in diagnosing facet disease. We prospectively evaluated the use of bone scintigraphy with SPECT for the identification of patients with low back pain who would benefit from medial branch block. Methods: SPECT was performed on 33 patients clinically suspected of facet joint disease. After SPECT, an ultrasound guided medial branch block was performed on all patients. On 28 SPECT-positive patients, medial branch block was performed based on the SPECT findings. On 5 negative patients, medial branch block was performed based on clinical findings. For one month, we evaluated the patients using the visual analogue scale (VAS) and Oswestry disability index. SigmaStat and paired t-tests were used to analyze patient data and compare results. Results: Of the 33 patients, the ones who showed more than 50% reduction in VAS score were assigned 'responders'. SPECT positive patients showed a better response to medial branch blocks than negative patients, but no changes in the Oswestry disability index were seen. Conclusions: SPECT is a sensitive tool for the identification of facet joint disease and predicting the response to medial branch block.