• Title/Summary/Keyword: Tomography, X Ray Computed

Search Result 704, Processing Time 0.023 seconds

Analysis of High-Resolution CT Findings in Patients with Spontaneous Pneumothorax (자연기흉환자의 고해상 CT소견의 분석)

  • 김양수;손동섭
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.383-387
    • /
    • 1999
  • Background: We analysed simple chest PA and high-resolution CT findings in patients with spontaneous pneumothorax in order to help selecting the kind of treatment, provide a guidline during surgical treatment, and to recognize the bulla which may not be detected by simple radiographs or may be a potential cause of recurrence. Material and Method: We retrospectively analysed the presence and number of bulla in each side, combined pulmonary disease on simple chest films and high-resolution CT, and methods and frequency of the treatment in 70 patients with spontaneous pneumothorax excluing traumatic origin. Result: 45 patients were revealed primary spontaneous pneumothorax, and the remaining 25 patients were revealed secondary spontaneous pneumothorax. All secondary spontaneous pneumothorax were from the longstanding sequelle of pulmonary tuberculosis. The patients with primary spontaneous pneumothorax group was younger(mean:26.0 years old) than secondary group (mean: 44.1 years old). On simple radiography, bulla was detected in 16 patients(30.2%). On HRCT, the bulla was detected in 53 patients(75.7%) of the total 70 patients. In 48 patients(68.6%), the bulla or bleb was noted in ipsilateral side to the pneumothorax, and 34 patients(48.6%) of them showed bulla or bleb bilaterally. 39 patients(55.7%) showed bulla or bleb in contralateral side. The number of bulla or bleb was variable. In secondary spontaneous pneumothorax group, the incidence of multiple(more than 10) bulla or bleb was higher than primary type. Most of the patients were treated by thoracostomy(36 patients) or bullectomy( 7 patients). Conclusion: HRCT was superior to detect bulla and analyse the combined pulmonary disease than simple radiography. Therefore, HRCT can help to determine the mothod of treatment, provide a guidline during surgical treatment, and notify the bulla as a possible cause of recurrent pneumothorax.

  • PDF

Management of Traumatic Diaphragmatic Rupture (외상성 횡격막 손상의 치료)

  • Kim, Seon Hee;Cho, Jeong Su;Kim, Yeong Dae;I, Ho Seok;Song, Seunghwan;Huh, Up;Kim, Jae Hun;Park, Sung Jin
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.217-222
    • /
    • 2012
  • Purpose: Diaphragmatic rupture following trauma is often an associated and missed injury. This report is about our experience with treating traumatic diaphragmatic rupture (TDR). Methods: From January 2007 to September 2012, 18 patients who had a diaphragmatic rupture due to blunt trauma or penetrating injury underwent an operation for diaphragmatic rupture at our hospital. We retrospectively reviewed their medical records, including demographic factors, initial vital signs, associated injuries, interval between trauma and diagnosis, injured side of the diaphragm, diagnostic tools, surgical method or approaches, operative time, herniated organs, complications, and mortality. Results: The average age of the patients was 43 years, and 16 patients were male. Causes of trauma included motor vehicle crashes (n=7), falls (n=7), and stab wounds (n=5). The TDR was right-sided in 6 patients and left-sided in 12. The diagnosis was made by using a chest X-ray (n=3), and thorax or upper abdominal computed tomography (n=15). Ten(10) patients were diagnosed within 12 hours. A thoracotomy was performed in 8 patients, a video-assisted thoracoscopic surgery in 4 patients, a laparotomy in 3 patients, and a sternotomy in one patient. Herniated organs were the omentum (n=11), stomach (n=8), spleen and colon (n=6), and liver (n=6). Eighteen diaphragmatic injuries were repaired primarily. Seven patients underwent ventilator care, and two of them had pneumonia and acute respiratory distress syndrome. There were no operative mortalities. Conclusion: Early diagnosis and surgical treatment determine the successful management of TDR with or without the herniation of abdominal organs. The surgical approach to TDR is chosen based on accompanying organ injuries and the injured side.

Recurrent Shoulder Dislocation and Proximal Humerus Fracture in Neurofibromatosis Type I - A Case Report - (제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 근위 상완골 골절 - 1예 보고 -)

  • Hwang, Tae Hyok;Cho, Hyung Lae;Wang, Tae Hyun;Yang, Hui Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.135-140
    • /
    • 2013
  • We report a case of recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I. A twenty-year-old male patient with known neurofibromatosis type I presented with right shoulder dislocation and proximal humerus fracture following a minor trauma. His injured arm also had large plexiform neurofibromas on the elbow, and the dislocation of the shoulder joint was proven to be recurrent. Bony deformation of the humerus and scapula were revealed on X-ray and computed tomography, as well as multiple neurofibromatic changes of the deltoid and periscapular muscles were noted on magnetic resonance imaging. Open reduction and capsular reconstruction were performed and humeral fracture was stabilized with a reconstruction plate. Satisfactory union and functional result were achieved and the dislocation did not recur until the 7-month followup after the procedure. Recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I are rare complications. However, it should still be considered in the orthopaedic evaluation process of the diseases.

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

Diagnostic imaging analysis of the impacted mesiodens (매복 정중치의 진단영상분석)

  • Noh, Jeong-Jun;Choi, Bo-Ram;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose : The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Materials and Methods : Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. Results : The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. Conclusion : It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

A Study on the Usefulness of 3D Imaging in Micro-CT for Observing the Microstructure of Mice (흰쥐 미세구조 관찰을 위한 Micro-CT 3D 영상의 유용성에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Chai, Kyu-Yun;Han, Beom-Hee;Han, Sang-Hyun;Hong, Dong-Hee;Han, Tae-Jong;Park, Sung-Hoon;Mo, Eun-Hee;Jun, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.367-375
    • /
    • 2014
  • In this thesis we observe microvascular structure in mice by using micro-computed tomography (CT), which is high-resolution X-ray imaging equipment that can acquire Real-time dynamic image, and it aims to investigate the usefulness of micro-CT developed by Institute for Radiological Imaging Science Wonkwang University School of Medicine. After acquiring the systemic images of rats, contrast-enhanced 3D images of vascular structures could be acquired by using Maximum Intensity Projection (MIP) and Volume Rending Technique (VRT), This was divided into each vascular system of head, abdomen and heart and systemic vascular system.

Utility of Micro CT in a Murine Model of Bleomycin-Induced Lung Fibrosis (Bleomycin 유도 폐 섬유화 쥐 모델에서 미세 전산화단층촬영의 유용성)

  • Lee, Jae A;Jin, Gong Yong;Bok, Se Mi;Han, Young Min;Park, Seoung Ju;Lee, Yong Chul;Chung, Myung Ja;Youn, Gun Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.5
    • /
    • pp.436-444
    • /
    • 2009
  • Background: Micro computed tomography (CT) is rapidly developing as an imaging tool, especially for mice, which have become the experimental animal of choice for many pulmonary disease studies. We evaluated the usefulness of micro CT for evaluating lung fibrosis in the murine model of bleomycin-induced lung inflammation and fibrosis. Methods: The control mice (n=10) were treated with saline. The murine model of lung fibrosis (n=60) was established by administering bleomycin intra-tracheally. Among the 70 mice, only 20 mice had successful imaging analyses. We analyzed the micro CT and pathological findings and examined the correlation between imaging scoring in micro CT and histological scoring of pulmonary inflammation or fibrosis. Results: The control group showed normal findings on micro CT. The abnormal findings on micro CT performed at 3 weeks after the administration of bleomycin were ground-glass opacity (GGO) and consolidation. At 6 weeks after bleomycin administration, micro CT showed various patterns such as GGO, consolidation, bronchiectasis, small nodules, and reticular opacity. GGO (r=0.84) and consolidation (r=0.69) on micro CT were significantly correlated with histological scoring that reflected pulmonary inflammation (p<0.05). In addition, bronchiectasis (r=0.63) and reticular opacity (r=0.83) on micro CT shown at 6 weeks after bleomycin administration correlated with histological scoring that reflected lung fibrosis (p<0.05). Conclusion: These results suggest that micro CT findings from a murine model of bleomycin-induced lung fibrosis reflect pathologic findings, and micro CT may be useful for predicting bleomycin-induced lung inflammation and fibrosis in mice.

CT Findings and Accuracy of Preoperative Pathologic Diagnosis in Bronchial Carcinoid According to Subtype (기관지 유암종의 아형에 따른 CT 소견과 수술전 병리학적 진단의 정확성)

  • 임준석;홍용국;정경영;최규옥
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.380-387
    • /
    • 1998
  • We evaluated CT findings of bronchial carcinoid and accuracy of preoperative pathological diagnosis according to two subtypes. The subjects were 10 cases(typical;5, atypical;5), confirmed by surgery and tissue pathology. Sputum cytology(n=10), percutaneous aspiration(n=1) and bronchoscopic biopsy (n=8) were performed, preoperatively. The CT findings were analysed according to two subtypes. Typical carcinoid shows central location in all, and bronchial lumens just proximal to tumor were widened in two, whereas atypical carcinoid presented as peripheral leison in two. Among central atypical carcinoid, two cases showed flat meniscus appearance of lumen. Remaining one showed diffuse wall thickening. Intratumoral low density by necrosis was noted in one. Both subtypes show contrast enhancement. For preoperative diagnosis, sputum cytology & percutaneous aspiration were not conclusive at all. As for bronchoscopic biopsy, only 3 cases were accurately diagnosed as typical carcinoid. Typical carcinoid presented as endobronchial mass in all, whereas atypical carcinoid presented in various appearance. In all atypical & some typical carcinoid were misdiagnosed as primary lung cancer, preoperatively. However, in typical carcinoid, conservative surgery was possible. In conclusion, if there is discrepancy between CT findings & preoperative pathological diagnosis, full understanding of CT findings of bronchial carcinoid is imperative to choose appropriate surgical modality.

  • PDF

Incidental Breast Lesions on Chest CT: Clinical Significance and Differential Features Requiring Referral (흉부 전산화단층촬영에서 우연히 발견된 유방 병변: 임상적 중요성 및 진료 의뢰가 필요한 특징적 영상 소견)

  • Choi, Yun Jung;Kim, Tae Hoon;Cha, Yoon Jin;Son, Eun Ju;Gweon, Hye Mi;Park, Chul Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.303-310
    • /
    • 2018
  • Purpose: To evaluate the CT features of incidental breast lesions on chest CT and to suggest useful criteria for referral to a specialized breast unit. Materials and Methods: Between May 2009 and April 2014, enhanced chest CT examination reports containing the key word 'breast' were reviewed retrospectively. Patients who had incidental breast lesion and were referred to a specialized breast unit and then underwent pathological confirmation or follow-up over a 1-year period were included. Finally, 86 patients (all female, mean age, $48.9{\pm}12.6years$) were enrolled. Two radiologists evaluated lesion characteristics, including size, shape, margins, and enhancement. The correlations between the CT features and pathologies were evaluated, and the diagnostic accuracy of CT features in various combinations was assessed. Results: Among the CT features, irregular shape, non-circumscribed margin, and high contrast enhancement were different between malignant and benign lesions (p < 0.05). The combination of non-circumscribed margin and high contrast enhancement had the highest accuracy (97.7%). Conclusion: Reliable CT features for incidental malignant breast masses are irregular shape, non-circumscribed margin, and high contrast enhancement. The combination of non-circumscribed margin and high contrast enhancement could help distinguish incidental malignant breast lesions and indicate referral to a specialized breast unit.