• Title/Summary/Keyword: Tomography, X Ray Computed

Search Result 706, Processing Time 0.025 seconds

3DentAI: U-Nets for 3D Oral Structure Reconstruction from Panoramic X-rays (3DentAI: 파노라마 X-ray로부터 3차원 구강구조 복원을 위한 U-Nets)

  • Anusree P.Sunilkumar;Seong Yong Moon;Wonsang You
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.7
    • /
    • pp.326-334
    • /
    • 2024
  • Extra-oral imaging techniques such as Panoramic X-rays (PXs) and Cone Beam Computed Tomography (CBCT) are the most preferred imaging modalities in dental clinics owing to its patient convenience during imaging as well as their ability to visualize entire teeth information. PXs are preferred for routine clinical treatments and CBCTs for complex surgeries and implant treatments. However, PXs are limited by the lack of third dimensional spatial information whereas CBCTs inflict high radiation exposure to patient. When a PX is already available, it is beneficial to reconstruct the 3D oral structure from the PX to avoid further expenses and radiation dose. In this paper, we propose 3DentAI - an U-Net based deep learning framework for 3D reconstruction of oral structure from a PX image. Our framework consists of three module - a reconstruction module based on attention U-Net for estimating depth from a PX image, a realignment module for aligning the predicted flattened volume to the shape of jaw using a predefined focal trough and ray data, and lastly a refinement module based on 3D U-Net for interpolating the missing information to obtain a smooth representation of oral cavity. Synthetic PXs obtained from CBCT by ray tracing and rendering were used to train the networks without the need of paired PX and CBCT datasets. Our method, trained and tested on a diverse datasets of 600 patients, achieved superior performance to GAN-based models even with low computational complexity.

Identification and Three-Dimensional Characterization of Micropore Networks Developed in Granite using Micro-Focus X-ray CT

  • Choo, Chang-Oh;Takahashi, Manabu;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.179-189
    • /
    • 2014
  • We analyzed the three-dimensional distribution of micropores and internal structures in both fresh and weathered granite using micro-focus X-ray computed tomography (micro-CT). Results show that the pore radius in fresh granite is mostly in the range of $17-50{\mu}m$, the throat radius is in the range of $5-25{\mu}m$, and the coordination number (CN) of pores is less than 10. In contrast, the pore radius in weathered granite is mostly in the range of $20-80{\mu}m$, the throat radius is in the range of $8-30{\mu}m$, and the CN is less than 12. In general, a positive linear relationship exists between pore radius and CN. In addition, both the size and the density of pores increase with an increasing degree of rock weathering. The size of the throats that connect the pores also increases with an increasing degree of weathering, which induces fracture propagation in rocks. Micro-CT is a powerful and versatile approach for investigating the three-dimensional distributions of pores and fracture structures in rocks, and for quantitatively assessing the degree of pore connectivity.

The Retrospective Study of Essential X-ray in Emergency Multiple Trauma Patients (응급 다발성 외상환자의 기본적 방사선 촬영부위에 관한 조사연구)

  • Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.51-57
    • /
    • 1996
  • Radiography should be used judiciously and should not delay patients resuscitation. In the patient with emergency multiple trauma, three radiography should be obtained-cervical spine, anteroposterior(AP) chest, and AP pelvis. These examinations can be done in the resuscitation area, usually with a portable X-ray unit, but should not interrupt the resuscitation process. A retrospective study was carried on 157 emergency multiple trauma patients who were admitted to Yong Dong Severance Hospital from January, to December in 1995. I analyzed the types of X-ray examinations in emergency multiple trauma patients, and classified the patients by disoriented group of mentality. The results were as follows: 1. The subjects were 7.1%(157patients) of 2,208 trauma patients(7.3%) in total 30,085 emergency patients. 2. Male to female ratio was 2.57 : 1. The age distribution was highest from 31 years to 40 years(28.0% ). 3. The peak time of patient's entrance in emergency center was between 8 : 00 pm and 2 : 00 am(36.9%), and second peak time was between 2 : 00 pm and 8 : 00 pm (29.3%). 4. According to the injury type, traffic accident, motorcycle accident and falling down were 71.3%, 8.3% and 20.4% respectively. 5. According to the exposure rate of Computed Tomography, chest CT, cervical CT pelvis CT and brain CT were 39.5%, 24.2%, 69.4% and 51.6% respectively.

  • PDF

Material Properties of GeSbSe Chalcogenide Glass and Fabrication Process for 8~12 ㎛ IR Region Aspherical Optical Lens (GeSbSe계 기반 8~12 ㎛ 파장대역 적외선 광학 렌즈 제작 및 비구면 렌즈 가공기술 개발)

  • Bae, Dong-Sik;Yeo, Jong-Bin;Han, Sang-Hyun;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.3
    • /
    • pp.183-189
    • /
    • 2013
  • The chalcogenide glass has superior optical properties in IR region transmittances. We have determined the composition of GeSbSe chalcogenide glass for the application of good IR lenses, resulting in the composite rate of $Ge_{19}Sb_{23}Se_{58}$. The optical, structural, thermal and physical properties were measured by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), Differential scanning calorimeter (DSC), X-ray computed tomography (X-ray CT) respectively. The fabrication of the chalcogenide glass lens for infrared optics applications was proposed using a diamond turning machining technology which is known as the suitable ways for the production cost reduction and the accurate fabrication process control.

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Variation of Physical and Microstructural Properties of Limestone caused by Artificial Freezing and Thawing (인공 동결-융해 풍화에 따른 석회암의 물성 및 미세구조 변화 분석)

  • Park, Jihwan;Park, Hyeong-Dong
    • Tunnel and Underground Space
    • /
    • v.25 no.5
    • /
    • pp.435-449
    • /
    • 2015
  • Physical and microstructural properties of Pungchon and Maggol limestone were investigated quantitatively during 50 cycles of artificial freezing and thawing test. There were decrease in dry weight and P,S-wave velocity, and increase in absorption rate in both rock types. Porosity, pore volume, equivalent diameter, throat thickness and pore orientation were analyzed using X-ray computed tomography images. Porosity increased, and initiation and expansion of pores were investigated as weathering progresses. Physical and microstructural variation in Maggol limestone was larger than that of Pungchon limestone because Maggol limestone has more pores and microcracks at initial state. As this study analyzes physical and microstructural properties of rock specimens comprehensively, it can be applied to further rock weathering study and can be used as fundamental data of construction and resource development in cold regions.

Rapid Rigid Registration Method Between Intra-Operative 2D XA and Pre-operative 3D CTA Images (수술 중 촬영된 2D XA 영상과 수술 전 촬영된 3D CTA 영상의 고속 강체 정합 기법)

  • Park, Taeyong;Shin, Yongbin;Lim, Sunhye;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1454-1464
    • /
    • 2013
  • In this paper, we propose a rapid rigid registration method for the fusion visualization of intra-operative 2D XA and pre-operative 3D CTA images. In this paper, we propose a global movement estimation based on a trilateration for the fast and robust initial registration. In addition, the principal axis of each image is generated and aligned, and the bounding box of the vascular shape is compared for more accurate initial registration. For the fine registration, two images are registered where the distance between two vascular structures is minimized by selective distance measure. In the experiment, we evaluate a speed, accuracy and robustness using five patients' data by comparing the previous registration method. Our proposed method shows that two volumes can be registered at optimal location rapidly, and robustly comparing with the previous method.

A Recurrent Spontaneous Pneumomediastinum (재발된 자발성 종격동기종)

  • Lim, Eun-Ju;Park, Yong Bum;Kim, Chang-Hwan;Park, Dong Sun;Kim, Min Guan;Kim, Chul-Hong;Park, Sang Myon;Lee, Jae Young;Mo, Eun Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.696-699
    • /
    • 2005
  • Spontaneous pneumomediastinum(SPM) is an uncommon disease that is defined as the nontraumatic presence of free air in the mediastinum without any apparent underlying disease. We report a case of recurrent spontaneous pneumomediastinum without any direct precipitating cause. A 21-year-old woman was admitted to hospital suffering from chest pain that occurred during walking (?). She had previously been well. She did not complain of cough or vomiting prior to this presentation. Upon admission, the physical examination and Electrocardiogram findings were normal. The chest x-ray and chest computed-tomography showed a pneumomediastinum. She was successfully managed conservatively. Twenty seven months later, she was readmitted with chest pain, which again occurred during the same activity. The recurrent SPM was confirmed by the chest x-ray and chest computed-tomography. She was managed in the same manner as before and made an uneventful recovery. This is the first case of recurrent SPM in Korea.

Generalized Pulp Stones of Primary Dentition in a Patient with Molar-Incisor Malformation : A Case Report (Molar-Incisor Malformation 환자의 유치열 내 전반적인 치수석 관찰의 증례 보고)

  • Lee, Dongyun;Shin, Jisun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.337-343
    • /
    • 2020
  • Molar-incisor malformation (MIM) is a new type of root anomaly reported recently. The characteristics of MIM are dysplastic root formations, constriction of pulp chambers and presence of calcified matrices at the level of cementoenamel junction in permanent first molars and primary second molars. In some cases, permanent maxillary incisors are also affected. The permanent first molars of the patient in this case report were affected with MIM. Generalized pulp stones were observed in overall primary dentition. Micro-computed tomography (micro-CT) imaging and scanning electron microscope-energy dispersive X-ray spectrometer analysis were performed on the extracted mandibular first molar and maxillary primary second molar of the patient. Micro-CT images revealed the discontinuity of enamel directly connected to an accessory canal of the root.