• Title/Summary/Keyword: Tomographic Reconstruction

Search Result 96, Processing Time 0.025 seconds

Tomographic Reconstruction of Two-Phase Flows

  • Ko, Han-Seo;Kim, Yong-Jae
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.571-580
    • /
    • 2003
  • Tomography has been investigated to observe bubble behaviors in two-phase flows. A bubbly flow and an annular flow have been reconstructed by tomography methods such as an algebraic reconstruction technique (ART) and a multiplicative algebraic reconstruction technique (MART) . Computer synthesized phantom fields have been used to calculate asymmetric density distributions for limited cases of 3, 5, and 7 projection angles. As a result of comparison of two tomography methods, the MART method has shown a significant improvement in the reconstruction accuracy for analysis of the two-phase flows.

A Spline-Regularized Sinogram Smoothing Method for Filtered Backprojection Tomographic Reconstruction

  • Lee, S.J.;Kim, H.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.311-319
    • /
    • 2001
  • Statistical reconstruction methods in the context of a Bayesian framework have played an important role in emission tomography since they allow to incorporate a priori information into the reconstruction algorithm. Given the ill-posed nature of tomographic inversion and the poor quality of projection data, the Bayesian approach uses regularizers to stabilize solutions by incorporating suitable prior models. In this work we show that, while the quantitative performance of the standard filtered backprojection (FBP) algorithm is not as good as that of Bayesian methods, the application of spline-regularized smoothing to the sinogram space can make the FBP algorithm improve its performance by inheriting the advantages of using the spline priors in Bayesian methods. We first show how to implement the spline-regularized smoothing filter by deriving mathematical relationship between the regularization and the lowpass filtering. We then compare quantitative performance of our new FBP algorithms using the quantitation of bias/variance and the total squared error (TSE) measured over noise trials. Our numerical results show that the second-order spline filter applied to FBP yields the best results in terms of TSE among the three different spline orders considered in our experiments.

  • PDF

Development of Tomographic Scan Method for Industrial Plants (산업공정반응기의 감마선 전산 단층촬영기술 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho;Kwon, Taek-Yong;Cho, Gyu-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.20-30
    • /
    • 2010
  • In this paper, a new tomographic scan method with fixed installed detectors and rotating source from gamma projector was presented to diagnose the industrial plants which were impossible to be examined by conventional tomographic systems. Weight matrix calculation method which was suitable for volumetric detector and statistical iterative reconstruction method were applied for reconstructing the simulation and experimental data. Monte Carlo simulations had been performed for two kinds of phantoms. Lab scale experiment with a same condition as one of phantoms, had been carried out. Simulation results showed that reconstruction from photopeak counting measurement gave the better results than from the gross counting measurement although photopeak counting measurement had large statistical errors. Experimental data showed the similar result as Monte Carlo simulation. Those results appeared to be promising for industrial tomographic applications, especially for petrochemical industries.

Image Reconstruction of Dielectric Cylinder Under Born Approximation Using a Coherent Tomographic Scheme in the Spatial Domain (공간영역에서 코히어런트 단층촬영 기법을 이용한 Born 근사하에 유전체 기둥의 영상제현)

  • 서경환;김상기;김세윤;라정웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1327-1335
    • /
    • 1990
  • In this paper, using the principle of duality between the spatial and spectral domain, we proposed a new microwave imaging technique of a coherent tomographic formulation in the spatial domain and reconstructed the image of dielectric cylinder through simulation and experiment. The numerical and experimental results for the variety o object size, relative dielectric constant have shown the limitation of Born approximation to be used and the effect of retrieved images for various signal bandwidth.

  • PDF

Tomographic Reconstruction of a Non-axisymmetric Diffusion Flame (자발광 확산 사각화염 내부 구조의 단층 진단)

  • Yang, In-Young;Ha, Kwang-Soon;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.105-115
    • /
    • 1999
  • The structure of a non-axisymmetric propane diffusion flame was investigated. Tomographic reconstruction method to convert the line-integrated self-emission data of a fuel-rich diffusion flame with square cross-section was applied to get the spatially reconstructed emission data. Modified Shepp-Logan filter and concentric squares raster were chosen for reconstructing arbitrarily shaped object in this process. Spatially reconstructed emission data were then interpreted to several physical quantities, such as flame edge, FWHM, perimeter and 3-D flame temperature distribution. Necessary assumptions were discussed and the results were interpreted. In comparison with axisymmetric flame, flame edge was developed higher, and sooting region of upstream was broader than in this non-axisymmetric one. At some height, the flame was shrunk very rapidly and finally formed circular cross-section.

  • PDF

A Comparative Study Between Light Extinction and Direct Sampling Methods for Measuring Volume Fractions of Twin-Hole Sprays Using Tomographic Reconstruction

  • Lee, Choong-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1986-1993
    • /
    • 2003
  • The spatially resolved spray volume fractions from both line-of-sight data of direct measuring cells and a laser diffraction particle analyzer (LDPA) are tomographically reconstructed by the Convolution Fourier transformation, respectively. Asymmetric sprays generated from a twin-hole injector are tested with 12 equiangular projections of measurements. For each projection angle, a line-of-sight integrated injection rate was measured using a direct sampling method and also a liquid volume fraction from a set of line-of-sight Fraunhofer diffraction measurements was measured using a light extinction method. Interpolated data between the projection angles effectively increase the number of projections, significantly enhancing the signal-to-noise level in the reconstructed data. The reconstructed volume fractions from the direct sampling cells were used as reference data for evaluating the accuracy of the volume fractions from the LDPA.

Holographic tomography: hardware and software solutions for 3D quantitative biomedical imaging (Invited paper)

  • Kus, Arkadiusz;Krauze, Wojciech;Makowski, Piotr L.;Kujawinska, Malgorzata
    • ETRI Journal
    • /
    • v.41 no.1
    • /
    • pp.61-72
    • /
    • 2019
  • In this paper, we demonstrate the current concepts in holographic tomography (HT) realized within limited angular range with illumination scanning. The presented solutions are based on the work performed at Warsaw University of Technology in Poland and put in context with the state of the art in HT. Along with the theoretical framework for HT, the optimum reconstruction process and data visualization are described in detail. The paper is concluded with the description of hardware configuration and the visualization of tomographic reconstruction, which is calculated using a provided processing path.

Tomographic Reconstruction of a Three-Dimensional Flow Field with Limited Interferometric Data

  • Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.11-22
    • /
    • 2000
  • Holographic interferometric tomography can provide reconstruction of instantaneous three-dimensional gross flow fields. The technique however confronts ill-posed reconstruction problems in practical applications. Experimental data are usually limited in projection and angular scanning when a field is captured instantaneously or under the obstruction of test models and test section enclosures. An algorithm, based on a series expansion method, has been developed to improve the reconstruction under the ill-posed conditions. A three-dimensional natural convection flow around two interacting isothermal cubes is experimentally investigated. The flow can provide a challenging reconstruction problem and lend itself to accurate numerical solution for comparison. The refractive index fields at two horizontal sections of the thermal plume with and without an opaque object are reconstructed at a limited view angle of 80$\circ$. The experimental reconstructions are then compared with those from numerical calculation and thermocouple thermometry. It confirms that the technique is applicable to reconstruction of reasonably complex, three-dimensional flow fields.

  • PDF

Scanning Tomographic Acoustic Microscope System by Using Transverse waves

  • Daesik Ko
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2E
    • /
    • pp.21-26
    • /
    • 1997
  • We propose to use transverse waves instead of longitudinal waves in a scanning tomographic acoustic microscope (STAM) and new type of multiple-transducer with the functions of muliple-angle and multiple-frequency tomography. Proposed multiple-transducer scheme has three insonification angles and three resonance frequencies in order to operate in the transverse wave mode and multiple-angle and multiple frequency tomography for the STAM. In order to evaluate the performance of proposed transducer scheme we have simulated tomographic reconstruction with back-and-forth propagation(BFP) algorithm. Simulation results showed proposed multiple-transducer scheme is capable of obtaining good resolution with transverse wave mode and multiple-frequency tomography. It is also showed that proposed scheme is an efficient rotation scheme by proportion to the number of projections.

  • PDF

Three Dimensional Computed Tomography in the Assessment of Subtle Fracture in Dogs (컴퓨터단층촬영에서 3차원 재구성 영상을 통한 개의 골절 진단)

  • 이기창;권정국;송경진;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.4
    • /
    • pp.523-526
    • /
    • 2003
  • Three dimensional computed tomographic images were obtained in two cases with trauma. The first case of a 3 year-old male Maltese, with ataxia and head tilting due to head trauma was referred to veterinary medical teaching hospital, Seoul National University. Remarkable findings were not found on survey radiographs. With the help of three-dimensional reconstruction computed tomographic imaging, parietal and occipital bone fracture was identified. The second case of 4 month-old female Yorkshire terrier with left forelimb lameness was referred right after trauma. Survey radiography showed obvious incongruity of the elbow joint. Lateral and medial condyle of the left humerus fracture and lateral displacement of the left ulna were apparent in three-dimensional computed tomographic image. It was considered that three-dimensional computed tomography could be used as an aid modality for the exact evaluation of extends and degree of fracture as well as planning of orthopedic surgery.