• Title/Summary/Keyword: Toluene Recovery

Search Result 79, Processing Time 0.028 seconds

Micro toluene gas sensor of SWNTs-PtOx system using the vacuum filtering deposition method (진공여과증착법을 이용한 SWNT-PtOx계 마이크로 톨루엔 가스센서)

  • Kim, Il-Jin;Jeon, Young-Zip;Choi, Chang-Kyu;Lee, Young-Uk;Choi, Si-Young;Han, Chang-Soo;Han, Sang-Do
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • Toluene($C_6H_5CH_3$) gas sensors were fabricated using $PtO_x$ loaded with SWNTs by a new deposition method. The nanoparticle powders of SWNTs-$PtO_x$ composite were deposited on Si wafer substrates by a vacuum filtering deposition method. The fabricated sensors were tested against toluene gas which is a kind of the Volatile Organic Compounds. The composition ratio that exhibited the highest response to toluene gases was SWNTs : $PtO_x\;=\;99:1$ in wt% ratio at operating temperature of about $150^{\circ}C$. The response and recovery times of the sensors were as short as less than 1 min., respectively.

A Study of surfactant-based remediation for removal of toluene and PCE in contaminated water

  • Kim, Eun-Sik;Lee, Dal-Heui;Chang, Ho-Wan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.302-305
    • /
    • 2003
  • The purpose of this study was to assess the effect of surfactant on the rate of NAPLs(non-aqueous phase liquids) solubilization. The experimental variables were surfactant type, NAPLs type and water type. The main experimental designs were consists of two phases. The solubilization rate is sensitive to surfactant type based on this test. Used aqueous surfactants were solubilized and removed 72.77 to 89.90% of toluene, PCE(tetrachloroethylene) from the contaminated water during the test, respectively. T60 has higher and stable recovery ratio than SDS in surfactant type but, the micelle of the T60 is more weaker than that of SDS based on this study's results. And the solubilization rate in used water type was almost same.(deionized water, surface water).

  • PDF

Formation of humus-bound residues in the course of BTX biodegradation in soil

  • Song, Hong-Gyu
    • Journal of Microbiology
    • /
    • v.35 no.1
    • /
    • pp.47-52
    • /
    • 1997
  • To examine whether the xylene component of BTX (benzene, toluene, xylene) mixture is cometabolized and residues are produced in soil, $\^$14/C-labeled-0-xylene was added to sandy loam in combination with unlabeled benzene and toluene. After 4 weeks of incubation in a sealed system connected to an oxygen reservoir, 55.1% of the radiocarbon was converted to $\^$14/CO$\sub$2/, 3.0% was to 95.8% radiocarbon recovery. Biomass incorporation of o-xylene radiocarbon which was detected by fumigation/extraction was usually low (5.6%), but 32.1% radiocarbon became associated with soil humus. Most of the numus-bound radiocarbon was found in humin fraction. In addition to o-xylene, p-xylene and toluene also showed similar results. The evidence shows that some of their reactive methylcatechol biodegradation intermediates attach to the humic metrix in soil in preference to mineralization and biomass incorporation.

  • PDF

A Study on the Release Characteristics of VOCs from Heat Recovery Ventilation System (폐열회수형 환기장치의 휘발성유기화함물 배출 특성에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sung
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.281-286
    • /
    • 2007
  • VOCs from the heat recovery ventilation system (total heat exchanger) are measured in this study. Two different types of element (L and M type) from heat recovery ventilating system are tested to study the intial release characteristics of VOCs under KS cooling and heating standard conditions. VOCs are measured for the various flow rates and different operating times. Considering errors in the test method and the measuring instrument, the tested heat recovery ventilating systems was found to release 6 major VOCs, such as acetic acid, 2-butanone (MEK), 2-(methylthio )ethylamine, toluene, styrene, and x-acids (Ion 57). The concentrations of released VOCs are not quite much affected by operating conditions. The results show much larger VOCs concentrations in the cooling mode than in the heating mode, due to the high operating temperatures.

  • PDF

Comparison of Adsorption and Desorption Characteristics of Acetone Vapor and Toluene Vapor on Activated Carbons According to Pore Structure (활성탄의 기공구조에 따른 아세톤 증기와 톨루엔 증기의 흡착 및 탈착특성 비교)

  • Lee, Song-Woo;Na, Young-Soo;An, Chang-Doeuk;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.21 no.10
    • /
    • pp.1195-1202
    • /
    • 2012
  • The purpose of this work is to study the adsorption and desorption characteristics of acetone vapor and toluene vapor from adsorption tower in the VOCs recovery device. The six kinds of activated carbon with different pore structures were used and the adsorption and desorption characteristics were compared according to pore structure, desorption temperature, and adsorption method, respectively. Adsorption capacity of acetone vapor and toluene vapor by batch method was higher than that by dynamic method. Especially, activated carbon with medium-sized or large pores had more difference in adsorption capacity according to adsorption methods as a result of gradually condensation of vapors on relatively mesopore and large pores. Activated carbons with relatively large pores and relatively small saturated adsorption capacity had excellent desorption ability.

Optimal Design of Solvent Recovery Process with Dividing Wall Column for Film Making Process (분리벽형 증류탑을 적용한 필름공정의 폐용매 회수공정 최적설계)

  • Lee, Seung-Hyun;Zo, Moon-Shin;Lee, Moon-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.12
    • /
    • pp.1209-1214
    • /
    • 2006
  • This paper presents an application of Dividing Wall Column(DWC) to the recovery of the waste solvent from the film making processes. The waste solvent feed contains MEK(Methyl-Ethyl-Ketone), Toluene, Cyclohexanone, and water. The commercial software $HYSYS^{TM}$ was used for rigorous simulation and analysis. Sensitivity analysis for several major design variables were carried out to achieve the optimal design of the process. Distribution of the internal vapor and liquid flows to the prefractionator and main sections is shown to be the most dominant design factor for energy saving efficiency in the DWC process. The simulation results also show that the solvent recovery process using the DWC significantly improves both the energy efficiency and the compactness of the solvent recovery process.

Fundamental Studies on the Equilibrium and Kinetics for the fractional Distillation Reaction of Waste Organic Solvent (폐용제 분별증류 회수 반응의 평형 및 속도론적 기초연구)

  • Noh Hyun-Sook;Kim Dong-Su
    • Resources Recycling
    • /
    • v.11 no.6
    • /
    • pp.38-46
    • /
    • 2002
  • Fundamental investigations were conducted far the recovery process of waste organic solvent by fractional distillation in the aspects of equilibrium and kinetics. Mixture of toluene and xylene, which were both being used in the largest amount as industrial organic solvent, was taken as the artificial waste organic solvent and their distillation behaviors were studied. The purity of recovered solvent was investigated by Cir Chromatography and shown to be in the range of 94~98%. Based upon equilibrium calculations, the changes in the Gibbs free energy, standard enthalpy, and standard entropy for distillation reaction have been estimated. The standard enthalpy changes for toluene and xylene were shown to be 44.833 and 47.044 kJ $mol^{-1}$ respectively, which were similar to their molar heats of evaporation. The activation energies of distillation fur toluene and xylene obtained from kinetic studies were 3.281 and 2.699 kJ $mol^{-1}$ and they were about one tenths of the standard enthalpy changes of distillation reaction. The highness of the purity of recovered organic solvents suggested the possibility that the recovered waste organic sol-vent could partly replace the original solvent.

Removal Characteristics of Volatile Organic Compounds in Biofilters and Stoichiometric Analysis of Biological Reaction by Carbon Mass Balance (바이오필터의 휘발성유기화합물 제거특성 및 탄소물질수지를 이용한 생물반응의 양론적 해석)

  • Kim, Dae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.747-753
    • /
    • 2010
  • This study was performed to investigate the removal characteristics of volatile organic compounds (VOCs) in the gasphase biofilters, and to propose a stoichiometric analysis approach to characterize biological reaction through carbon mass balance. The VOCs studied were toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) as a single substrate for each biofilter. The critical loading rate was determined to be $46.9\;g/m^3{\cdot}hr$, $25.8\;g/m^3{\cdot}hr$, $96.3\;g/m^3{\cdot}hr$, and $66.5\;g/m^3{\cdot}hr$ for toluene, styrene, MEK, and MIBK, respectively. The obtained results indicated that the critical loading rate was well correlated the octanol-water partition coefficient. In the analysis of carbon mass balance, carbon recovery to $CO_2$ became relatively lower as substrate loadings increased, but higher for carbon recovery to biomass. Stoichiometric analysis revealed that biomass yield increased as substrate loadings increased, and its coefficient (g biomass/g substrate) varied from 0.31 to 0.57 for toluene, 0.29 to 0.57 for styrene, 0.08 to 0.56 for MEK, and 0.14 to 0.53 for MIBK.

Method Validation and Uncertainty Estimation for Toluene Measurement in Biological Fluids by HS-GC (HS-GC에 의한 생체 시료내 톨루엔 분석에 대한 방법의 유효화와 불확도 추정)

  • Heo, Sangcheol;Min, Ji-Sook;Park, Jongseo;Lim, Mi-Ae;Park, Sungwoo
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.443-453
    • /
    • 2004
  • Toluene is currently used as a major organic solvent of glues which are abused by the youngster for its hallucinogenic effect. In this study, toluene determination method using headspace gas chromatography (HS-GC) in the biological fluids like blood, urine and saliva of glue sniffers was validated and related uncertainties were estimated. LOD of $0.01{\mu}g/mL$ in saliva and LOQ of $0.1{\mu}g/mL$ in blood were the highest among LODs and LOQs in urine, blood and saliva. Other performance characteristics such as linearity, working range, accuracy, precision and recovery were also measured. The uncertainty at toluene concentration of $1{\mu}g/mL$ was estimated to be 0.13, 0.09 and $0.17{\mu}g/mL$ for blood, urine and saliva, respectively, and the uncertainty contribution from the least linear regression was dominant at the lower concentration of toluene.

A Study on Urinary Trans, Trans-Muconic acid, Hippuric acid of gas station worker according to the use of gasoline vapor recovery system (유증기 회수설비 유무에 따른 주유소 근로자들의 요중 trans, trans-Muconic acid, Hippuric acid에 관한 연구)

  • Choi, Jaejun;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.152-159
    • /
    • 2014
  • Objectives: This study aims to investigate the excretion aspect of urinary t, t-MA and hippuric acid by measuring concentrations of urinary metabolites according to the use of gasoline vapor recovery system. Materials:In order to analyze urinary metabolites, samples from the 23 gas station workers ten gas stations in the Seoul and Gyeonggi Province area were collected once daily after work. In addition, a survey was conducted on work factors and lifestyle habits as factors affecting the concentration of urinary metabolites. Results: The average concentrations of t, t-MA and hippuric acid after work were $0.124{\pm}0.177mg/g$ creatinine and $0.557{\pm}0.251g/g$ creatinine among workers at gas stations where gasoline vapor recovery systems were installed. The average concentrations of t, t-MA and hippuric acid were $0.160{\pm}0.113mg/g$ creatinine and $0.682{\pm}0.619g/g$ creatinine among workes at gas stations where gasoline vapor recovery systems were not installed. Average concentrations were higher at gas stations where a gasoline vapor recovery system was not installed, but the differences were not statistically significant differences. Urinary t, t-MA and hippuric acid average concentrations of smokers and non-smokers were higher in the gas stations where gasoline a vapor recovery system was not installed. T, t-MA as a factor evaluation affecting the concentration of urinary metabolites was not statistically significant in all factors, while hippuric acid was statistically significant only for age(p=0.024). Conclusions: The average concentrations of urinary t, t-MA and hippuric acid were higher in gas stations where gasoline vapor recovery systems were not installed compared to gas stations where such a system was installed. There needs to be an assessment of biological monitoring according to refueling activity considering skin absorption of benzene and toluene and presence of gasoline vapor recovery system.