• 제목/요약/키워드: Tolerance limits

검색결과 122건 처리시간 0.03초

고속철도 전차선로 고장력 실시간 모니터링 기술 구현 (Implementation Technique of Real-time Monitoring System for High-Speed Rail Contact Wire with High Tension)

  • 조용현;박영;정현진
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1256-1261
    • /
    • 2015
  • Along with the increase of railway catenary system operation speed to 400 km/h, there have been growing demands for good quality current collection systems that satisfy quality standards as well as criteria for safe working. Retaining uniform elasticity tension of contact wires is essential in maintaining high quality contact between pantograph and OCL (Overhead Contact Line) of current collection systems in high speed railways. Therefore, the tension of contact wire must be kept within tight tolerance limits in both working conditions and adverse weather conditions of catenary system. In accordance with these conditions, this paper presents a real time monitoring system for the tensioning device of the newly installed catenary system on the special route of Honam high speed line for 400 km/h operation. For the verification of the true value of tension of contact wires, we have developed ring-type tensioning sensors which were installed on supporting points of mast which compose the catenary system. According to the field test performed on the Honam high speed line catenary system, variation of tension was measured accurately in real-time.

DC 전동기의 강인 제어를 위한 PID-관리 복합형 제어기 (PID-Supervision Hybrid Controller for Robust Control of DC Motor)

  • 전정채;오훈;박왈서;조현섭;유인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.244-246
    • /
    • 1998
  • Robust control for DC motor is needed according to the highest precision of industrial automation. However when a motor control system with PID controller has an effect of load disturbance, it is very difficult to guarantee the robustness of control system. As a compensation method solving this problem, in this paper, PID-supervision hybrid control method for motor control system is presented. If the PID control system (without the supervisory controller) is stable in the sense that the error is inside the constraint set, the supervisory control is idle. If the error hits the boundary of the constraint, the supervisory controller begins operation to force the error back to the constraint set. We prove that the PID-supervision hybrid control system is globally stable in the sense that the error is guaranteed to be within the tolerance limits specified by the system designer.

  • PDF

전파무향실용 페라이트 전파흡수체의 설계 (Design of Ferrite Electromagnetic Wave Absorber for Anechoic Chamber)

  • 김동일;이창우;김하근;전상엽;정세모
    • 한국정보통신학회논문지
    • /
    • 제3권1호
    • /
    • pp.43-50
    • /
    • 1999
  • Electromagnetic wave absorbers for anechoic chamber are needed to broaden the useful frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve the above requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer. Therefore, an air layer is formed absorber between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 450 MHz in frequency band, far narrower than the aimed bandwidth. The purpose of this paper is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for prevention of TV ghost, etc. Accordingly, in this paper, a broadened electromagnetic wave absorber is designed, which has the reflection characteristics less than -20 dB from 30 MHz to 5,430 or 8,000 MHz in the bandwidth. Then we will design a super broadband electromagnetic wave absorber by inserting square Ferrite Cylinders Type with the thickness less than 23.5 m in three-layed type and with the frequency band from 30 MHz to 5,430-8,000 MHz under the above tolerance limits.

  • PDF

PID-자기동조 제어방식에 의한 DC 서보 전동기의 속도제어 (The Speed Control of a DC Servo Motor by the PID Self Tuning Control Method)

  • 조현섭;구기준
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1560-1564
    • /
    • 2008
  • 산업 자동화의 고정밀도에 따라 직류 전동기는 강인제어가 요구되고 있다. 하지만 PID 제어기를 갖는 전동기 제어 시스템이 부하 외란의 영향을 받게되면 제어 시스템의 강인제어는 어렵게 된다. 이에 대한 보완적인 한 방법으로 본 논문에서는 전동기 제어시스템을 위한 PID-자기동조 제어기법을 제시하였다. 만약 오차가 구속영역 내에 있고, 시스템이 안정한 상태에 있다면 자기동조는 사용되지 않고 PID 제어기만 동작한다. 자기동조 제어기는 오차가 구속 경계에 도달하게 되면 오차를 구속 영역내로 들어가도록 제어를 시작한다. PID-자기동조 제어 시스템의 오차가 시스템 설계자의 허용한도 내에서 유지되고 전체적으로 안정함을 증명하였다.

PID-관리 복합형 제어기를 이용한 직류 전동기의 강인한 속도제어 (Robust Speed Control of DC Motor Using PID-Supervision Hybrid Controller)

  • 전정채;조현섭;박왈서
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.70-74
    • /
    • 1998
  • 산업 자동화의 고정밀도에 따라 직류 전동기는 강언제어가 요구되고 있다. 하지만 PID 제어기를 갖는 전동기 제어 시스템이 부하 외란의 영향을 받게되면 제어 시스템의 강인제어는 어렵게 된다. 이에 대한 보완적인 한 방법으로 본 논문에서는 전동기 제어시스템올 위한 PID-관리 복합형 제어기법을 제시하였다. 만약 오차가 구속영역 내에 있고, 시스템이 안정한 상태에 있다면 관리 제어기는 사용되지 않고 PID 제어기만 동작한다. 관리 제어기는 오차가 구속 경계에 도달하게 되면 오차를 구속 영역내로 들어가도록 제어를 시작한다. 우리는 PID-관리 복합형 제어 시스램의 오차가 시스템 설계자의 허용한도 내에서 유지되고 전체적으로 안정함을 증명하였다.

  • PDF

Positive Regulator, a Rice C3H2C3-type RING Finger Protein H2-3(OsRFPH2-3), in Response to Salt Stress

  • Min Seok Choi;Cheol Seong Jang
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2023년도 춘계학술대회
    • /
    • pp.156-156
    • /
    • 2023
  • Salinity is a major abiotic stress that limits rice productivity in many regions of the world. In order to develop salt stress tolerant rice plants, genetic engineering is a promising approach. We characterized the molecular function of rice C3H2C3 as a really interesting new gene (RING). Oryza sativa RING finger protein H2-3 (OsRFPH2-3) was highly expressed in 100 mM NaCl. To identify the localization of OsRFPH2-3, we fused vectors that include C-terminal GFP protein (35S;;OsRFPH2-3-GFP). OsRFPH2-3 was expressed in the nucleus in rice protoplasts. An in vitro ubiquitin assay demonstrated that OsRFPH2-3 possessed E3-ubiquitin ligase activity. However, the mutated OsRFPH2-3 were not possessed any E3-ubiquitin ligase activity. Under salinity conditions, OsRFPH2-3-overexpressing plants exhibited higher chlorophyll, proline, SOD, POD, CAT, and soluble sugar contents and lower H2O2 accumulation than wild-type plants, supporting transgenic plants with enhanced salinity tolerance phenotypes. OsRFPH2-3-overexpressing plants exhibited low Na+ accumulation and Na+/K+ ratios in their roots. Theses results suggest that overexpression of OsRFPH2-3 can make plant insensitivity about salinity conditions.

  • PDF

6 시그마와 총 오차 허용범위의 개발에 대한 연구 (A Study of Six Sigma and Total Error Allowable in Chematology Laboratory)

  • 장상우;김남용;최호성;김영환;추경복;정혜진;박병옥
    • 대한임상검사과학회지
    • /
    • 제37권2호
    • /
    • pp.65-70
    • /
    • 2005
  • Those specifications of the CLIA analytical tolerance limits are consistent with the performance goals in Six Sigma Quality Management. Six sigma analysis determines performance quality from bias and precision statistics. It also shows if the method meets the criteria for the six sigma performance. Performance standards calculates allowable total error from several different criteria. Six sigma means six standard deviations from the target value or mean value and about 3.4 failures per million opportunities for failure. Sigma Quality Level is an indicator of process centering and process variation total error allowable. Tolerance specification is replaced by a Total Error specification, which is a common form of a quality specification for a laboratory test. The CLIA criteria for acceptable performance in proficiency testing events are given in the form of an allowable total error, TEa. Thus there is a published list of TEa specifications for regulated analytes. In terms of TEa, Six Sigma Quality Management sets a precision goal of TEa/6 and an accuracy goal of 1.5 (TEa/6). This concept is based on the proficiency testing specification of target value +/-3s, TEa from reference intervals, biological variation, and peer group median mean surveys. We have found rules to calculate as a fraction of a reference interval and peer group median mean surveys. We studied to develop total error allowable from peer group survey results and CLIA 88 rules in US on 19 items TP, ALB, T.B, ALP, AST, ALT, CL, LD, K, Na, CRE, BUN, T.C, GLU, GGT, CA, phosphorus, UA, TG tests in chematology were follows. Sigma level versus TEa from peer group median mean CV of each item by group mean were assessed by process performance, fitting within six sigma tolerance limits were TP ($6.1{\delta}$/9.3%), ALB ($6.9{\delta}$/11.3%), T.B ($3.4{\delta}$/25.6%), ALP ($6.8{\delta}$/31.5%), AST ($4.5{\delta}$/16.8%), ALT ($1.6{\delta}$/19.3%), CL ($4.6{\delta}$/8.4%), LD ($11.5{\delta}$/20.07%), K ($2.5{\delta}$/0.39mmol/L), Na ($3.6{\delta}$/6.87mmol/L), CRE ($9.9{\delta}$/21.8%), BUN ($4.3{\delta}$/13.3%), UA ($5.9{\delta}$/11.5%), T.C ($2.2{\delta}$/10.7%), GLU ($4.8{\delta}$/10.2%), GGT ($7.5{\delta}$/27.3%), CA ($5.5{\delta}$/0.87mmol/L), IP ($8.5{\delta}$/13.17%), TG ($9.6{\delta}$/17.7%). Peer group survey median CV in Korean External Assessment greater than CLIA criteria were CL (8.45%/5%), BUN (13.3%/9%), CRE (21.8%/15%), T.B (25.6%/20%), and Na (6.87mmol/L/4mmol/L). Peer group survey median CV less than it were as TP (9.3%/10%), AST (16.8%/20%), ALT (19.3%/20%), K (0.39mmol/L/0.5mmol/L), UA (11.5%/17%), Ca (0.87mg/dL1mg/L), TG (17.7%/25%). TEa in 17 items were same one in 14 items with 82.35%. We found out the truth on increasing sigma level due to increased total error allowable, and were sure that the goal of setting total error allowable would affect the evaluation of sigma metrics in the process, if sustaining the same process.

  • PDF

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

Hydrogen Peroxide 처리가 여름철 시설오이의 수분 스트레스, 광합성, 내서성에 미치는 영향 (The Influence of Hydrogen Peroxide Treatment on Water Stress, Photosynthesis and Thermotolerance of Cucumber(Cucumis sativus) in Greenhouse Cultivation during Summer)

  • 우영회;김형준;김태영;김기덕;허윤찬;전희;조일환;남윤일;고관달;이관호;홍규현
    • 생물환경조절학회지
    • /
    • 제15권1호
    • /
    • pp.47-52
    • /
    • 2006
  • This studies were carried out in summer season to increase high temperature tolerance using hydrogen peroxide treatments on cucumber in greenhouse. The water stress of cucumber in greenhouse by the hydrogen peroxide treatments showed as control>250 mM>500 mM treatments in order. The photosynthesis rate of cucumber at $30^{\circ}C$ did not show difference with each hydrogen peroxide treatment in temperature controlled greenhouse. However, the photosynthesis rate of cucumber in the control and hydrogen peroxide treatments at $40^{\circ}C$ was significantly different. The photosynthesis rate of cucumber in combined treatment with 1,000 $mg{\cdot}L^{-1}\;CO_2$ supply and hydrogen peroxide was also higher than control, however, there was no different of photosynthesis in 250 mM and 500 mM treatment. The value of $F_v/F_m$ and $F_m/F_o$ of chlorophyll fluorescent in 500 mM hydrogen peroxide treatment at $40^{\circ}C$ was highest. Also the activity of POD, the antioxidant enzyme, was higher with high hydrogen peroxide concentration than the other treatments. The high temperature limits for growth were $43^{\circ}C$ in the control, $44^{\circ}C$ in the 250 mM and $46^{\circ}C$ in the 500 mM according to analyze chlorophyll fluorescent $F_o$. The high temperature tolerance in cucumber increased approximately $3^{\circ}C$ by the hydrogen peroxide treatments under this experiment conditions.

진단용 CT-모의치료기 테이블의 효율적인 교정 방법 (An Efficient Correction Process of CT-Simulator Couch with Current Diagnostic CT Scanners)

  • 구은회;이재승;조정근;문성권
    • 한국콘텐츠학회논문지
    • /
    • 제9권11호
    • /
    • pp.254-261
    • /
    • 2009
  • 본 연구는 진단용 CT 장치를 이용한 CT-모의치료기의 테이블 및 레이저 정렬 시스템과 횡단면 영상의 중심간 정렬을 개선하기 위한 효율적인 방법을 제안하고자 하였다. 본원에서 제작한 팬텀을 이용하여 AAPM TG66에서 제시하는 일일 정도관리를 시행하고 기하학적 삼각함수를 이용하여 레이저 정렬 시스템을 교정하였으며 교정 전, 후를 비교함으로서 교정방법에 대한 효율성을 검토하였다. 교정 전 영상의 중심간 오차는 3.82mm, 테이블 종축은 $0.436^{\circ}$ 틀어져 진행하였다. 기하학적 삼각함수를 이용한 레이저 정렬 시스템의 교정 후 0.7mm의 중심간 오차가 발생하여 ${\pm}2mm$의 허용오차 범위를 만족하였다. 설치 가동 중인 진단용 CT 장치를 방사선치료 전용 CT-모의치료기로 활용하는 경우 기하학적 정확도를 만족시키기 위한 테이블 교정은 기술적인 한계 뿐 만 아니라 시간 및 경제적 손실에 비하여 매우 비효율적이다. 그러나 레이저 정렬 시스템을 이용한 교정 방법은 경제적이고 비교적 간단하면서도 만족스러운 기하학적 정확도를 얻을 수 있어 임상에서 적용할 수 있는 효율적인 방법이라 사료된다.