• Title/Summary/Keyword: Toe transfer

Search Result 50, Processing Time 0.027 seconds

Influence of Bias Weight of Vibratory Pile Driver on Load Transfer Characteristics of Piles (진동타입기의 사하중이 말뚝의 하중전이 특성에 미치는 영향)

  • Lee, Seung-Hyun;Kim, Byung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5268-5273
    • /
    • 2013
  • Technique for analyzing pile installed by vibratory pile driver was developed and results of analysis obtained from variation of bias weight were studied. It can be seen from load transfer curve for dynamic skin friction that load transfer curve shift to downward as bias weight increases. Shape of load transfer curve for dynamic skin friction becomes closer to shape of coil as the bias weight decreases. Magnitudes of toe resistances were not affected by the bias weight. Shape of load transfer curve for dynamic toe resistance shows the similar tendency as the load transfer curve for skin friction exhibits. Vertical displacement increases as the bias weight increases and the shape of vertical displacement with time shows more distinct shape of wave.

Toe to Finger Transfer in Traumatic Amputated Index Finger (외상성 시지 결손 환자에서 족지를 이용한 수지 재건술)

  • Lee, Kwang-Suk;Park, Sang-Won;Kang, Oh-Yong;Choi, Yong-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 1993
  • Traumatic loss of the fingers present significant functional disability and the index finger is an important component of hand function. Since 1900, many attempts and efforts have been done in reconstruction of amputated fingers with toes. Authors clinically analyzed 8 cases of toe-to-finger transfer in traumatic amputation of the index finger to be followed for more than one year at Korea University Hospital from August 1982 to December 1991. The results were as follows: 1. The most common cause of injury was mechanical accident in 7 of 8 cases. 2. Average interval between injury and operation was 8 year 3 months. 3. Average operation time was 5 hours 58 minutes and average ischemic time of transferred toe was 1 hour 52 minutes. 4. Skin flaps have survived in 7 of 8 cases, and the functional results in 6 of 8 cases were over than fair.

  • PDF

Split Transfer of Extensor Digitorum Longus of the Second Toe for Elongation of EHB after Modified Jones' Procedure (변형된 Jones 술식 후에 발생한 단무지 신전건의 연장을 치료하기 위한 제2 장족지 신전건의 분리 이전술)

  • Kim, Jung-Rae;Lee, Woo-Chun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.3
    • /
    • pp.183-186
    • /
    • 2011
  • Extensor hallucis brevis (EHB) is only extensor of the first metatarsophalangeal (MTP) joint after modified Jones procedure. Therefore preserving the normal insertion of the EHB has been emphasized during that procedure. We experienced a case of EHB rupture after modified Jones procedure and had satisfied surgical outcome by partial transfer of extensor digitorum longus (EDL) of second toe.

Implementation of a TCP/IP Offload Engine Using Lightweight TCP/IP on an Embedded System (임베디드 시스템상에서 Lightweight TCP/IP를 이용한 TCP/IP Offload Engine의 구현)

  • Yoon In-Su;Chung Sang-Hwa;Choi Bong-Sik;Jun Yong-Tae
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.7
    • /
    • pp.413-420
    • /
    • 2006
  • The speed of present-day network technology exceeds a gigabit and is developing rapidly. When using TCP/IP in these high-speed networks, a high load is incurred in processing TCP/IP protocol in a host CPU. To solve this problem, research has been carried out into TCP/IP Offload Engine (TOE). The TOE processes TCP/IP on a network adapter instead of using a host CPU; this reduces the processing burden on the host CPU. In this paper, we developed two software-based TOEs. One is the TOE implementation using an embedded Linux. The other is the TOE implementation using Lightweight TCP/IP (lwIP). The TOE using an embedded Linux did not have the bandwidth more than 62Mbps. To overcome the poor performance of the TOE using an embedded Linux, we ported the lwIP to the embedded system and enhanced the lwIP for the high performance. We eliminated the memory copy overhead of the lwIP. We added a delayed ACK and a TCP Segmentation Offload (TSO) features to the lwIP and modified the default parameters of the lwIP for large data transfer. With the aid of these modifications, the TOE using the modified lwIP shows a bandwidth of 194 Mbps.

Outpatient Percutaneous Flexor Tenotomy for Diabetic Claw Toe Deformity with Ulcer (궤양을 동반한 당뇨성 갈퀴 족지에 대하여 외래에서 시행한 경피적 굴곡건 절단술)

  • Lee, Dong-Hun;Chung, Jin-Wha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.4
    • /
    • pp.151-155
    • /
    • 2018
  • Purpose: Toe ulcers have been implicated as a causative factor in diabetic foot amputation. The aim of this study was to evaluate the outcomes of percutaneous needle flexor tenotomies of diabetic claw toes with ulcers or pending ulcers. Materials and Methods: The authors undertook a retrospective chart review between January 2014 and June 2016 to identify those patients who underwent a percutaneous needle flexor tenotomy for diabetic claw toe deformities. We evaluated 54 toes in 42 patients. Twenty-four patients were female and the mean age at the time of operation was 57 years. The mean follow-up time was 11 months. Thirty-four patients (46 toes) had tip toe ulcers or pending ulcers and 8 patients (8 toes) had dorsal pending ulcers. All patients had palpable pulses and good capillary refill. Results: Forty-three of 46 tip toe ulcers (93.5%) healed without significant complications and 8 dorsal ulcers showed no specific changes within 5 weeks. There were no recurrent ulcers at final follow-up. Four patients developed transfer lesion of the adjacent toe and needed subsequent tenotomy. Conclusion: Percutaneous needle tenotomy in an outpatient clinic was an effective and safe method for treating toe ulcers in neuropathic patients to offload the tip of the toe so that ulcer healing could occur.

Evaluation of the q-w Curve on Rock-Socketed Drilled Shafts by Triaxial Compression Tests (삼축압축시험을 통한 암반에 근입된 현장타설말뚝의 선단 하중전이곡선 산정)

  • Kim, Tae-Hyung;Kim, Yong-Min;Jeong, Sang-Seom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.455-465
    • /
    • 2008
  • In this study, the load distribution and deformation of rock-socketed drilled shafts subjected to axial load are investigated based on small scale model tests. In order to analyze the effects of major influencing factors of end bearing capacity, Hoek-cell triaxial tests were performed. From the test results, it was found that the initial slope of end bearing load transfer (q-w) curve was highly dependent on rock mass modulus and pile diameter, while the ultimate unit toe resistance ($q_{max}$) was influenced by rock mass modulus and the spacing of discontinuities. End bearing load transfer function of drilled shafts socketed in rock was proposed based on the Hoek-cell triaxial test results and the field loading tests which were performed on granite and gneiss in South Korea. Through the comparison with pile load tests, it is found that the load-transfer curve by the present study is in good agreement with the general trend observed by field loading tests, and thus represents a significant improvement in the prediction of load transfer of drilled shaft.

  • PDF

Morbidity of the Foot as a Free-Flap Donor Site (유리 피판 공여부로서 족부의 이병률)

  • Lee, Kwang-Suk;Wie, Dae-Gon;Han, Sang-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.39-46
    • /
    • 1997
  • The methods of clinical applications of the foot as a free-flap donor site includes microvascular toe-to-finger transfer, free neurovascular flap transfer, first web space flap transfer, and osteocutaneous free flap transfer. We have evaluated the results of treatment for 35 patients to be undergone a microvascular reconstructive procedure with the foot as a donor site from January 1982 to June 1996. The performed operations were 16 cases of thumb reconstruction with wrap around procedure, 3 cases of tenocutaneous flap transfer, 10 cases of dorsalis pedis flap transfer, 2 cases of first web space free flap and 4 cases of toe-to-finger transfer. The follow up study was 69 months in average. Regarding to the various donor sites, morbidity was divided into five different categories: Cosmesis, Functional loss, Sensory loss, Wound complication, and Pain. According to the results of examination(35 patients), the results was excellent(25), good(9), fair(1), and poor(0). Among the categories, morbidity was higher at cosmesis. The patients under 50 years were better outcome. Among the operative methods from the foot as a donor site, thumb reconstruction with wrap around procedure showed poorest outcomes. So, We conclude that the foot as a free flap donor site is a good source for the microvascular reconstructive surgery. But, Preoperative donor site evaluation, adequate operative technique and post operative management are essential to decrease the morbidity of donor site.

  • PDF

Partial second toe pulp free flaps in early childhood

  • Hong, Min Ki;Lee, Dong Chul;Choi, Min Suk;Koh, Sung Hoon;Kim, Jin Soo;Roh, Si Young;Lee, Kyung Jin
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.590-596
    • /
    • 2020
  • Background The introduction of the partial second toe pulp free flap has enabled superior aesthetic and functional results for fingertip reconstruction in adults. Children undergoing fingertip amputation for various reasons have limited options for reconstruction. Conventional treatment could shorten the finger, leading to poor cosmesis and function. We report 18 years of our experiences with fingertip reconstruction using partial second toe pulp free flaps in patients in early childhood. Methods Medical charts of children who had undergone fingertip reconstruction using partial second toe pulp free flaps from 2001 to 2018 were retrospectively reviewed. The surgical procedures were identical to those for adults, except for the usage of 11-0 nylon sutures. Patients' demographic data, vessel size, flap dimensions, length of the distal phalanx, and functional outcomes over the course of long-term follow-up were documented. The statistical analysis was performed with the Student t-test, the Mann-Whitney U test, and Pearson correlation analysis. Results Eighteen toe pulp flaps in 17 patients (mean age, 3.0 years) were identified. All the flaps survived without any major complications. In long-term follow-up, the flap-covered distal phalanges showed growth in line with regular development. There was no donor-site morbidity, and all children adapted to daily life without any problems. In two-point discrimination tests, the fingertip sensation recovered to almost the same level as that in the contralateral finger. Conclusions Partial second toe pulp free flaps are an excellent option for fingertip reconstruction in young children, as well as in adults.

Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds (블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구)

  • Joe, Won-Hwa;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 2010
  • This study evaluated the energy efficiency of a windows system using built-in blinds, with regard to their insulation performance and their blocking of solar radiation. The study took advantage of the "Physibel Voltra" program as a physical simulation of heat transfer. To simulate the "Physibel Voltra" program, I practiced a mock-up test to determine heating quality and translation condition. I analyzed the propensity to annual energy consumption, the annual quantity of heat transfer, and the annual cooling and heating cost through a computer simulation for one general household in an apartment building. In the test, it was found that compared to a general windows system, a windows system with built-in blinds reduced the annual heat transfer by 10% in cooling states and by 11% in heating states when the blind was up. When the blind was down, the windows system with built-in blinds reduced the annual heat transfer by 25% in cooling states and 30% in heating states. When a windows system with built-in blinds is compared with a general windows system, the quantity of cooling and heating loads is reduced by 283.3kw in cooling states and 76.3kw in heating states. This leads to a reduction in the required cooling and heating energy of 359.6kw per house. It is thus judged that the use of a windows system with built-in blinds is advantageous in terms of reducing greenhouse gas emissions, because the annual TOE (tons of oil equivalent) per house is reduced by 0.078TOE, while $tCO_2$ is reduced by $0.16tCO_2$. In addition, compared with a general windows system, the cost of cooling and heating loads in the system reduces the annual cooling cost by 100,000won, and the annual heating cost by 50,000won. Ultimately, this means that cooling and heating loads are cut by 150,000won per year.