• Title/Summary/Keyword: Toe

Search Result 1,123, Processing Time 0.024 seconds

The Effects of Toe-Tap Exercise on Dynamic Balance and Muscle Activity of Gluteus Maximus (토탭 운동이 동적균형과 큰볼기근의 근활성에 미치는 영향)

  • Kwak, Hye-yeon;Kim, Hyun-mok;Yun, Gyeong-a;Lee, Gyu-hwan;Goo, Bong-oh
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • Background: This study hypothesized that increased muscle activity and balancing ability of the gluteus maximus during toe-tap exercise. Design: Cross sectional Study. Methods: After hearing the explanation of the experiment, the subjects performed a Star excursion balance test and measured the Maximum Voluntary Isomeric Contraction (MVIC). After toe-tap exercise, the MVIC was measured again and the Star excursion balance test was measured. Results: There was no significant difference in activity of gluteus muscle before and after the toe-tap exercise. There was a significant difference in the balance ability in the lateral, posterolateral, and posterior sides of the non-superior foot, but there was no significant difference in the anterior, anterolateral, posteromedial, medial, and anteromedial sides. In the case of superior foot, there were significant differences in six directions, with the exception of anterolateral and lateral sides. Conclusion: The pelvic stabilizing "gluteus maximus" exercises for balance, which is currently on the table, has many high-level exercises that are hard to do unless you're an athlete. But the Toe-tap exercise is also possible for the elderly and weak women.

A Security Policy Statements Generation Method for Development of Protection Profile (PP 개발을 위한 보안정책 문장 생성방법)

  • 고정호;이강수
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.13 no.4
    • /
    • pp.13-28
    • /
    • 2003
  • The Protection Profile(PP) is a common security function and detailed statement of assurance requirements in a specific class of Information Technology security products such as firewall and smart card. The parts of TOE security environment in the PP have to be described about assumption, treat and security policy through analyzing purpose of TOE. In this paper, we present a new security policy derivation among TOE security environment parts in the PP. Our survey guides the organizational security policy statements in CC scheme through collected and analyzed hundred of real policy statements from certified and published real PPs and CC Toolbox/PKB that is included security policy statements for DoD. From the result of the survey, we present a new generic organizational policy statements list and propose a organizational security policy derivation method by using the list.

Correlation Analysis between Kinematic Variables and Ground Slope Perception Ability during Golf Putting (골프 퍼팅 시 운동학적 변인과 경사도 인지능력 간 상관성 분석)

  • Lee, Jae-Woo;Im, Young-Tae;Kwon, Moon-Seok;Park, Jun-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.727-734
    • /
    • 2021
  • The purpose of this study was to analyze correlation between kinematic variables and ground slope perception ability during golf putting. 16 collegiate golfers were participated. To collect and analyze the kinematic data of putter head, SAMPutt lab was used(70 Hz). It was performed Pearson's correlation analysis using SPSS. The level of significance was at .05. As a results, right was correlated with backswing in flat. Toe-up was correlated with follow-through and left was correlated with aim, backswing, impact, follow-through, and loft in slice 1°. Toe-down was correlated with aim, backswing, impact in slice 2°. Toe-up was correlated with follow-through in hook 2°. In conclusion, it is important to improve the putting stroke through repetitive ground slope perception training.

Continuance Intention to use Remote Work Solutions(RWS) in the with Covid-19 Era: Focused on the TOE (Technology-Organization-Environment) Model (위드 코로나 시대의 원격근무 솔루션 지속 사용 의도에 관한 연구: TOE(Technology-Organization-Environment) 모델을 중심으로)

  • Yujin Choi;Heetae Yang
    • Information Systems Review
    • /
    • v.25 no.2
    • /
    • pp.163-180
    • /
    • 2023
  • Based on the Technology-Organization-Environment (TOE) model, this study proposed a research model that explains the continuance intention of users in the with Covid-19 era considering the technical, organizational, and environmental aspects of Remote Work Solution (RWS). To verify the research model and hypothesis, an online survey was conducted on domestic RWS users. Partial least squares (PLS) were utilized to analyze the collected 411 data. As a result of the analysis, it was found that functionality and security level had positive impacts on both productivity improvement and satisfaction. However, it was also confirmed that organizational readiness had a positive effect on productivity improvement but did not affect satisfaction. Furthermore, the results revealed that government support had a positive relationship with continuance intention, but the health concerns did not. Finally, the correlations between productivity improvement, satisfaction, and continuous intention were confirmed to be significant. Therefore, 9 out of a total of 11 hypotheses were supported.

A Study on the Characteristics of Waste Heat from the Industrial Complexes for Residential and Commercial Sectors (가정.상업부문 이용을 위한 산업체 폐열특성 연구)

  • 최영찬;박태준;홍재창;조선영
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.242-247
    • /
    • 1999
  • The characteristics of waste heat effluents from 11 industrial complexes of 7 areas were analyzed to investigate the possibility of waste heat recovery of huge amount of waste heat producing from various industrial complexes. This study presents a part of the research work for the industrial waste heat for development of energy integrated network system in broad city area, which will utilize industrial waste heat for residential and commercial areas, where they are located at some distances from the complexes. The amount of waste heat from the investigated complexes was detected as 148,913 TOE/year. However, It was analyzed 83% of the waste heat was analyzed the temperature range from 0$^{\circ}C$ to 200$^{\circ}C$. Also, it was evaluated that 82% of waste heat was exhausted by flue gases. Especially, the characteristics of waste heat for the areas where most heat concentrated, such as Tae-gu industrial complex, Ul-san petrochemitry complex, Yio-chun petrochemistry complex, and Chun-ju industrial complex were investigated more precisely. Total amount of waste heat discharged from these four areas were analyzed 114,402 TOE/year, which was occupied as 77% of the total waste heat for the studied areas, and 87% of the waste heat from the industries was exhausted by flue gaseous phase and temperature range was from 0$^{\circ}C$ to 200$^{\circ}C$ 18.1 million TOE/year waste heat was released from the fossil fuel power plants, however 95% of waste heat was analyzed as cooling water from surface condensers at power plants. The temperature range was measured from 27$^{\circ}C$ to 34$^{\circ}C$, which are unable to utilize due to its low temperature. Otherwise, 5% (894,800 TOE/year) waste heat released from power plants were observed as flue gas, which temperature ranged from 90$^{\circ}C$ to 170$^{\circ}C$.

  • PDF

Comparison between Moberg Flap and Second Toe Pulp Free Flap for Coverage of Tip Amputation of Thumb (무지 첨부 절단 환자 재건에서 Moberg Flap과 2족지 수질부 유리피판술의 비교)

  • Jung, Gang Jae;Ki, Sae Hwi;Kim, Jin Soo;Lee, Dong Chul;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.527-532
    • /
    • 2008
  • Purpose: Transverse type or volar oblique type of defect of thumb tip can be covered by Moberg flap or second toe pulp free flap. We compared these two methods in functional result, patients' satisfaction, and sensation, etc. to find a better way to cover the defect of the thumb tip. Methods: From 2003 to 2006, we chose the patients randomly with preoperative pictures. The patients had the defect of the thumb tip which is either transverse or volar oblique type. The 6 patients were treated with Moberg flap and other 6 patients were treated with second toe pulp free flap. We have analyzed the results by 2 point discrimination, side pinching power test, pulp to pulp pinching power test, pain scales (visual analogue scale), satisfaction scales of the patients (functional and aesthetic), the degree of the range of motion, etc. Results: All flaps survived without any complications. In the cases of Moberg flaps, the value of static 2 point discrimination test was 5.6 mm, and the value of moving 2 point discrimination test was 4.8 mm. In the cases of second toe pulp free flaps, the values were 9.6 mm and 9.3 mm. In the cases of Moberg flaps, the value of the Side pinch power test was 6.6 kg, 4.4 kg. In the case of second toe pulp free flaps, the values were 4.8 kg and 2.5 kg. The value of aesthetic satisfaction scale of the patients in Moberg flaps was 5.6, the value of functional satisfaction scale of the patients was 3.6. In cases of second toe pulp free flaps, the values were 5.6 and 3.6. The active range of motion of Interphalangeal joint in the cases of Moberg flaps was 46.6 degree, and the active range of motion of metacarpophalangeal joint was 55 degree, in the cases of second toe pulp free flaps, the values were 36.6 degree and 59 degree. Conclusion: As a result, when the defect of the thumb tip is transverse or volar oblique type, we suggest that the operators choose Moberg flap to cover the defect of the thumb tip.

The Effect of Second Toe Valgus on Correction Loss of Hallux Valgus Angle in Surgical Treatment (무지외반증 수술에서 제 2족지의 외반 정도가 무지 외반각 교정소실에 미치는 영향)

  • Kang, Suk Woong;Song, Moo Ho;Kim, Yeong Joon;Oh, Young Kwang;Yoo, Seong Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.135-138
    • /
    • 2017
  • Purpose: The purpose of this study is to determine the correlation between the correction loss of hallux valgus angle and the severity of valgus angle of the second toe. Materials and Methods: We selected 312 cases from 268 surgical patients with hallux valgus deformity receiving distal chevron osteotomy. For a radiological evaluation, we analyzed the changes in the hallux valgus angles, first to second intermetatarsal angles, and valgus angle of the second toe post index operations. All patients were women; the mean age was 46 years. The mean follow-up period was 17 months. Results: The mean hallux valgus angle was $33.6^{\circ}$ preoperatively (range, $25.7^{\circ}{\sim}44.8^{\circ}$), $13.1^{\circ}$ (range, $8.4^{\circ}{\sim}16.4^{\circ}$) after 4 weeks of postoperative period, and $17.1^{\circ}$ (range, $9.4^{\circ}{\sim}28.5^{\circ}$) at their final follow-up. The mean valgus angle of the second toe was $8.4^{\circ}$ preoperatively (range, $2.0^{\circ}{\sim}25.8^{\circ}$) and $8.3^{\circ}$ (range, $1.7^{\circ}{\sim}24.9^{\circ}$) at the final follow-up. Preoperatively, there was a positive correlation between the valgus angle of the second toe and hallux valgus angle (r=0.747, p=0.001). The correction loss of hallux valgus angle had a significant correlation with the severity of valgus angle of the second toe (r=0.802, p=0.001). Conclusion: The existence of the second toe valgus deformity may present itself as a cause of correction loss of hallux valgus angle. The preoperative measurement of the second toe valgus angle may be a good predictor of correction loss; therefore, thorough preoperative warning on the possibility of correction loss should be conducted to maximize patient satisfaction after the procedure.

A Study on the Utilization of potential heat sources for Heat Pumps to District Heating System in Urban (도시 내 지역난방 Heat Pump용 잠재열원 이용에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.841-855
    • /
    • 2018
  • The purpose of this study is to estimate the available potential heat source for heat pump in the district heating supply area in the city. Unused energy potentials were estimated and integrated based on open source based data. In particular, geographical spatial analysis of recoverable heat energy density and heat demand in the heat source area of large retailers and public sauna facilities in the DH network located in the southern part of the metropolitan area (Pyeongtaek-si) was conducted. As a result of the study, the DH network area had a total potential energy of 1,741.7 toe/year for the two heat sources of large retailers and public saunas. It is estimated that 1,006.9 toe/year, which is 57.8% of the total, can be linked to the district heating. The large retailers showed a positive correlation with the floor area and energy use of 0.4937. The recoverable energy intensity was estimated to be $0.0017toe/m^2$ per unit area and $0.0069tCO_2/m^2$ for greenhouse gas emissions. In addition, public saunas were analyzed by comparing the empirical case with the theoretical calculation, and it was estimated that energy conservation estimate of 80% was $0.0315toe/m^2$ per bath area and $0.1183tCO_2/m^2$ for greenhouse gas emissions. The total potential energy amount of this area was positively correlated with the heat demand of apartment house by administrative district, and it was confirmed that it had a relatively high potential energy especially in traffic and commercial center.

A Study for Seepage Control of Levee with a Pervious Toe Drain (제내 비탈끝 배수공을 이용한 제방의 침투조절에 관한 연구)

  • Kong, Young-San;Kang, Tae-Uk;Lee, Sang-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.6
    • /
    • pp.569-581
    • /
    • 2012
  • The levee is the facility which is constructed along with river for the protection of landside and for passage of water when there is a flood. When the seepage is exposed to the atmosphere on the landside surface of levee, it may eventually lead to levee failure. The seepage water may be removed from the landside surface by a properly designed drainage system. The purpose of the study is to show seepage control effect of a pervious toe drain, and to compare two drainage methods of a pervious toe drain. One is the pervious toe drain suggested by U.S. Army Corps of Engineers (USACE) and the other is that suggested by Japan Institute of Construction Engineering (JICE). The levee model constructed has the following dimension: the base width is 2.6 m; the crest width is 0.4 m; the side slope 1 : 2. The water depth in the riverside is 0.5 m. The shape of the toe drain by USACE is triangular. The shape of the toe drain by JICE is rectangular. They were installed with the base length of 0.4 m. The levee model without the toe drain showed saturation surface on the land side in the experiment but not with the toe drain. The experiment results was applied to a numerical analysis model using SEEP/W to calibrate and verify. The numerical analysis results for 35 cm and 30 cm drain width showed that the drain by JICE is a little bit safer than the drain by USACE. It is also easier to construct the toe drain by JICE. The results in the study would be applied to plan the seepage control for a levee with pervious toe drain.