• Title/Summary/Keyword: Tm3+

Search Result 2,032, Processing Time 0.03 seconds

A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS (근관 전색재의 방사선 불투과성에 관한 비교연구)

  • Kim, Tae-Min;Kim, Seo-Kyoung;Hwang, In-Nam;Hwang, Yun-Chan;Kang, Byung-Cheol;Yoon, Suk-Ja;Lee, Jae-Seo;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-$Seal^{TM}$. Kerr Pulp Canal $Sealer^{TM}$, AH $26^{(R)}$, AH $plus^{(R)}$, AH plus $jet^{TM}$, Ad sea $1^{TM}$. $Sealer^{TM}$, $NOGENOL^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$ and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.

A comparative study on the accuracy of the devices for measuring the implant stability

  • Cho, In-Ho;Lee, Young-Il;Kim, Young-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.124-128
    • /
    • 2009
  • STATEMENT OF PROBLEM. How the ISQ values measured by $Osstell^{TM}$ and $Osstell^{TM}$ Mentor are related, and whether the ISQ values acquired from the two machines changes in accordance with changes in implant stability are not yet fully understood. PURPOSE. The aim of this study was to find out correlation between the ISQ values acquired from $Osstell^{TM}$ and $Osstell^{TM}$ Mentor, and to evaluate the clinical effectiveness and accuracy of two devices. MATERIAL AND METHODS. Sixty two implants were inserted into 47 patients, and their ISQ values were measured using $Osstell^{TM}$ and $Osstell^{TM}$ Mentor. In the first stage surgery, the ISQ values of forty four implants inserted into thirty five patients were measured. In the second stage surgery, the values of fifty implants inserted into thirty seven patients were measured. The values were analyzed to determine the difference between the mean ISQ values of $Osstell^{TM}$ and $Osstell^{TM}$ Mentor. In addition, the correlation between implants used in the first and second stage of surgery with regard to their types and areas of insertion were analyzed. The difference between the ISQ values of 32 implants in each patient during the first and second stage was analyzed. The statistical assessment was carried out using SPSS V. 12.0 for Win. (SPSS Inc., Chicago, USA). The Pearson correlation coefficient was used to examine the correlation between $Osstell^{TM}$ and $Osstell^{TM}$ Mentor in the first and second stages of surgery, whereas the difference between their ISQ values was evaluated using a paired t-test. RESULTS. In the first stage, the mean ISQ value for $Osstell^{TM}$ and $Osstell^{TM}$ Mentor was 70.84 and 75.09, respectively, showing a significant difference (P < .01). In the second stage, the mean ISQ value of $Osstell^{TM}$ and $Osstell^{TM}$ Mentor was 71.76 and 75.94, respectively, also showing a significant difference (P < .01). The difference between the ISQ values in patients in the first and the second stages was significant with both instruments. CONCLUSION. The significant difference in the values obtained using the $Osstell^{TM}$ and $Osstell^{TM}$ Mentor between the first and second stages of implant surgery indicates that these values can be a convenient and precise way for evaluating the implant stability in clinical practice.

Validation and Calibration of 2D Numerical Model for Analysis of Turbidity Current Regimes in Soyang Reservoir (소양호 탁수거동 해석을 위한 2차원 수치 모형의 보정 및 검증)

  • Ryu, In-Gu;Chung, Se-Woong;Yoon, Sung-Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.253-257
    • /
    • 2010
  • 최근 들어 이상 강우 현상으로 인한 기록적인 집중 강우와 더불어 토지 이용 변화로 인해 탁수의 발생 빈도가 증가하고 있다. 강우 유출로 유입한 탁수는 저수지 내 장기간 체류하면서 하류 하천의 수질 및 수생태계 뿐만 아니라 저수지 내부의 영양단계에도 많은 영향을 준다. 특히, 성층화된 저수지의 경우 높은 영양염류 농도를 포함한 탁수는 밀도류 거동 특성을 보이면서 수평 및 수직 혼합 과정을 거치면서 국부적인 부영양화 현상과 조류의 수화 현상의 원인이 되고 있다. 따라서 대형 저수지의 수질관리에 있어 하천 유입 탁수의 밀도류 해석, 저수지의 수온 성층 구조 변화, 부유입자의 동력학적 해석이 중요한 요소로 부각되어 왔다. 본 연구에서는 소양호를 연구 대상 지역으로 선정하여 2005년과 2007년 수문 사상을 바탕으로 2차원 횡방향 수치 모형을 구축하였다. 수치모형을 통해 수온 성층 구조의 재현성을 확인하였으며, 다양한 탁수 거동 모형을 구축하여 적용성을 평가하였다. 유입수의 SS(Suspended Solid)를 단일 입경으로 가정한 TM-1 모형, SS의 입경분포에 따라 3개의 그룹(SSi)으로 구분한 TM-2 모형, 3개 그룹을 포함하면서 저수지내 탁수 장기화로 인한 탁수 저감 효과를 1차 반응상수로 매개 변수화(유기물 함량($a_0$) ${\times}$ 분해속도(${\lambda}_a$))하여 수정된 지배방정식을 적용한 TM-3 모형을 사용하였다. 각각의 탁수 거동 모형은 2005년과 2007년 수문 조건에서 수온 성층 구조를 잘 재현하였다. TM-1 모형과 TM-2 모형을 비교해보면, 탁수 중심축의 최고 탁도에 대한 예측 성능은 TM-2 모형이 우수한 결과를 나타냈었다. 하지만, 장기 탁수 모의 시 저수지 수중 잔류 SS가 지속적으로 높게 나타나 중층 탁도를 과대평가하는 경향을 보였다. TM-3 모형이 TM-2 모형에 비해 수심별 탁도 분포에 대한 중심축 탁도가 저평가되는 경향을 보였지만 저수지 내 잔류 탁도에 대한 영향 부분에서는 개선된 결과를 나타내었다. 본 연구 결과는 저수지 탁수 밀도류 해석 및 운영 시스템에 활용 될 수 있으며, 선택 취수 설비 등의 수리 구조물의 영향 평가에 활용할 수 있다.

  • PDF

Studies on the Comparative Analysis Between GE Prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool (골절의 절대위험도 평가방법에서 GE Prodigy와 FRAX Tool의 비교분석에 관한 고찰)

  • Lee, Hwa-Jin;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Mu-Seok;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: World Health Organization (WHO) have suggested that an individual's 10-year absolute fracture risk is more reliable than Bone Mineral Density (BMD) measurement as the predictor of osteoporotic fracture. In 2008, Fracture Risk Assessment Tool ($FRAX^{TM}$) was developed by WHO to evaluate fracture risk of patients based on individual's clinical risk factors. The purpose of this study is to offer the comparative analysis of the existing GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Materials and Methods: 201 women ($55{\pm}3.5$ years) underwent femoral neck BMD measurement using GE Prodigy. The 10-year probability (%) of hip fracture (or a major osteoporosis-related fracture) was estimated using T-scores of GE prodigy and $FRAX^{TM}$. We made a comparative analysis of these data using SPSS (Ver.12). Results: There was a significant difference statistically between T-score ($-0.52{\pm}0.97$) of GE prodigy and T-score ($-1.45{\pm}0.81$) of $FRAX^{TM}$ (r=0.977, p=0.000). Also, there was a significant difference statistically between a major osteoporosis- related fracture ($9.15{\pm}3.71$) of GE prodigy and a major osteoporosis-related fracture ($4.87{\pm}1.51$) of $FRAX^{TM}$ (r=0.909, p=0.000). Moreover, a statistically significant difference was found in the 10-year probability of hip fracture of GE prodigy ($1.56{\pm}1.48$) and of hip fracture ($0.53{\pm}0.61$) of $FRAX^{TM}$ (r=0.905, p=0.000). Conclusions: There was a significant difference statistically between GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Especially, T-score, a major osteoporosis-related fracture and the 10-year probability of hip fracture that were estimated using GE prodigy tended to show the higher results than one evaluated by $FRAX^{TM}$ Tool. In conclusion, $FRAX^{TM}$ Tool may provide a better tool. The application of $FRAX^{TM}$ Tool as a fracture predictor remains to be clarified.

  • PDF

Upconversion Mechanisms in $Tm^{3+}$-doped Glasses under 800 nm Excitation (800nm 파장 여기관에 의한 $Tm^{3+}$첨가 유리내 상향 전이 현상 기구)

  • Jeong, Hoon;Chung, Woon-Jin;Heo, Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.2
    • /
    • pp.111-116
    • /
    • 2000
  • 700nm red emission(3F3longrightarrow3H6) in Tm3+ ion with 800 nm(3H6longrightarrow3H4) excitation via upconversion process has been reported only in host materials which have low phonon energies such as halide crystals. However, we observed 700nm and 480nm(1G4longrightarrow3H6) upconverted emission with 800nm excitation in several oxide glasses which has never reported. With spectroscopic analyses and lifetime measurements of each nergy level of Tm3+ ion doped in various oxide glasses, following mechanisms are suggested. For red upconversion, upconversion mechanism changed with Tm3+ concentration. While direct excitation up to 3F3 level via anti-Stokes excitation was dominated at low concentration, two-step excitation via 3H6longrightarrow3H4 and 3F4longrightarrow3F3 transitions was dominated at high concentration. For blue upconversion, two step excitation mechanism up to 1G4 level was suggested as follows : electrons are exciated up to 3H5 with direct excitation with pumping light up to 3H4 followed by multiphonon relaxation, and then additional reabsorption of pumping light excites electrons up to 1G4.

  • PDF

Molecular Cloning and Characterization of a Gene Encoding Thermostable Pectinase from Thermotoga maritima

  • Kim, Chung Ho
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.2
    • /
    • pp.137-140
    • /
    • 2014
  • A gene encoding thermostable pectinase (TmPec) was isolated from hyperthermophilic microorganism, Thermotoga maritima. The open reading frame (ORF) of TmPec gene is 1,104 bp long and encodes 367 amino acid residues with a molecular weight of 40,605 Da. To analyze the enzymatic activity and biochemical properties, the ORF of TmPec gene excluding putative signal sequence of 27 amino acids was introduced into the E. coli expression vector, pRSET-B, and overexpressed in E. coli BL21. Protein concentration of purified recombinant TmPec was 1.1 mg/mL with specific activity of 56 U/mg protein on pectin. The recombinant TmPec showed the highest activity at around $85-95^{\circ}C$, and at around pH 6.5. It was stable at temperature below $85^{\circ}C$. In the presence of $Ca^{2+}$, the activity of recombinant TmPec was increased to 146.3% of normal level. In contrast, $Ba^{2+}$ and Mn2+ showed strong inhibition to the recombinant TmPec.

Fluorine and Heavy Metal Oxide Effects on Spectral Properties of Tm3+ in Silicate Glasses

  • Cho, Doo-Hee;Seo, Hong-Seok;Park, Bong-Je;Park, Yong-Gyu
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.8
    • /
    • pp.725-729
    • /
    • 2003
  • The fluorine doping along with heavy metal oxides remarkably raised the $^3$H$_4$ lifetime and the quantum efficiency in Tm$^{3+}$-doped silicate glasses. 29 mol% of fluorine substitution for oxygen in 70SiO$_2$-15Pbo-12ZnO-3KO$_{1}$2/ glass raised $^3$H$_4$ lifetime to 193 $mutextrm{s}$. Refractive indices were raised by heavy metal oxide substitution, but hardly changed by fluorine substitution. The fluorine doping changed the local structure around Tm$^{3+}$ions, then low energy vibrations related to fluorine are considered to largely reduce the multi-phonon relaxation rates in the oxyfluoride silicate glasses. The $^3$H$_4$ lifetimes and absorption and emission spectra of Tm$^{3+}$doped silicate and oxyfluoride silicate glasses are reported, and Judd-Ofelt calculation results are discussed in this paper.

Influence of Perfluorinated Polymer Passivation on AlGaN/GaN High-electron-mobility Transistors (질화갈륨계 고전자이동도 트랜지스터에 대한 불소계 고분자 보호막의 영향)

  • Jang, Soohwan
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.511-514
    • /
    • 2010
  • Perfluorinated polymer($Cytop^{TM}$) was deposited on selective area of AlGaN/GaN HEMT structure using low cost and simple spin-coating method, and the electrical characteristics of the device was analyzed for application of passivation layer on semiconductors. Gate lag measurement results of $Cytop^{TM}$ passivated and unpassivated HEMT were compared. Passivated device shows improved 65 % pulsed drain current of dc mode value. Rf measurements were also performed. $Cytop^{TM}$ passivated HEMT have similar rf performance to PECVD grown $Si_3N_4$ passivated device. $Cytop^{TM}$ passivation layer may play an important role in mitigating surface state trapping in the region between gate and drain.

Alleviation of Ultraviolet B-Induced Photoaging by 7-MEGATM 500 in Hairless Mouse Skin

  • Park, Kyo-Hyun;Kim, JiYeon;Jung, Suryun;Sung, Kyung-hwa;Son, Yeon-Kyoung;Bae, Jung Min;Kim, Bae-Hwan
    • Toxicological Research
    • /
    • v.35 no.4
    • /
    • pp.353-359
    • /
    • 2019
  • The purpose of this study was to investigate the effect of $7-MEGA^{TM}$ 500 on the improvement of skin aging in an UVB-induced photo-aging model of hairless mice. The dorsal skin of hairless mice was exposed to UVB three times a week for 12 weeks to induce skin wrinkle. After inducing the wrinkle, $7-MEGA^{TM}$ 500 was orally administered once a day for 4 weeks. Skin thickness, skin barrier function, and wrinkle indicators were improved by treatment with $7-MEGA^{TM}$ 500. Both gene and protein expression levels of MMP-3 and c-Jun in skin were significantly decreased by $7-MEGA^{TM}$ 500. Therefore, the intake of $7-MEGA^{TM}$ 500 is thought to have a positive effect on the improvement of skin aging, although further studies are needed.