• Title/Summary/Keyword: Tm3+

Search Result 2,032, Processing Time 0.029 seconds

A STUDY ON THE SHEAR BOND STRENGTH AND THE ANTICARIOGENICITY OF GLASS IONOMER CEMENT FOR BRACKET BONDING (브라켓 접착용 글라스 아이어노머 시멘트의 접착강도 및 항우식 효과에 관한 연구)

  • Kang, Yong-Joo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.538-553
    • /
    • 1999
  • The purpose of this study was to compare the shear bond strength and the anticariogenicity of glass ionomer cement with conventional bonding resin and fluoride releasing resin. After the shear bond strength test, scanning electron microscopic observation was performed for the evaluation of the fracture patterns in each group. Under the polarizing light microscope, artificially induced carious lesions were evaluated and the lesion depths of the samples were measured using image analyzing program(Image-Pro $PLUS^{TM}$, USA). 50 sound maxillary premolars were used for the bond strength test and another 30 for the anticariogenic test. Data collected were analyzed statistically using Oneway-ANOVA and Scheffe test. The results were as follows: 1. Glass ionomer groups(G-III, IV, V) generally showed the lower bond strength values than resin groups(G-I, II). 2. Among the two resin groups, G-I showed the higher bond strength than G-II without statistically significant difference between them(p>.05). 3. Within glass ionomer groups, statistical significance was found between G-III and G-V with the superior bond strength in G-V (p<.05). 4. Under the SEM, adhesive failure was the predominant fracture pattern in G-I and II, whereas cohesive failures were mainly observed in G-III. In G-IV and V, mixed type of pattern where the both fracture patterns coexisted within samples could be seen. 5. In evaluation of the depth of artificially developed carious lesion, glass ionomer group showed shallower depth than resin groups with statistical significance between G-III and G-I, II(p<.05). Among resin groups, fluoride releasing resin(G-II) showed the shallower depth than conventional resin(G-I)(p<.05).

  • PDF

Development of Radiosynthetic Methods of 18F-THK5351 for tau PET Imaging (타우 PET영상을 위한 18F-THK5351의 표지방법 개발)

  • Park, Jun-Young;Son, Jeong-Min;Chun, Joong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.51-54
    • /
    • 2018
  • Purpose $^{18}F-THK5351$ is the newly developed PET probe for tau imaging in alzheimer's disease. The purpose of study was to establish the automated production of $^{18}F-THK5351$ on a commercial module. Materials and Methods Two different approaches were evaluated for the synthesis of $^{18}F-THK5351$. The first approach (method I) included the nucleophilic $^{18}F$-fluorination of the tosylate precursor, subsequently followed by pre-HPLC purification of crude reaction mixture with SPE cartridge. In the second approach (method II), the crude reaction mixture was directly introduced to a semi-preparative HPLC without SPE purification. The radiosynthesis of $^{18}F-THK5351$ was performed on a commercial GE $TRACERlab^{TM}$ $FX-_{FN}$ module. Quality control of $^{18}F-THK5351$ was carried out to meet the criteria guidelined in USP for PET radiopharmaceuticals. Results The overall radiochemical yield of method I was $23.8{\pm}1.9%$ (n=4) as the decay-corrected yield (end of synthesis, EOS) and the total synthesis time was $75{\pm}3min$. The radiochemical yield of method II was $31.9{\pm}6.7%$ (decay-corrected, n=10) and the total preparation time was $70{\pm}2min$. The radiochemical purity was>98%. Conclusion This study shows that method II provides higher radiochemical yield and shorter production time compared to the pre-SPE purification described in method I. The $^{18}F-THK5351$ synthesis by method II will be ideal for routine clinical application, considering short physical half-life of fluorine-18 ($t_{1/2}=110min$).

Brain F-18 FDG PET for localization of epileptogenic zones in frontal lobe epilepsy: visual assessment and statistical parametric mapping analysis (전두엽 간질에서 F-18-FDG PET의 간질병소 국소화 성능: 육안 판독과 SPM에 의한 분석)

  • Kim, Yu-Kyeong;Lee, Dong-Soo;Lee, Sang-Kun;Chung, Chun-Kee;Yeo, Jeong-Seok;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.131-141
    • /
    • 2001
  • Purpose: We evaluated the sensitivity of the F-18 FDG PET by visual assessment and statistical parametric mapping (SPM) analysis for the localization of the epileptogenic zones in frontal lobe epilepsy. Materials and Methods: Twenty-four patients with frontal lobe epilepsy were examined. All patients exhibited improvements after surgical resection (Engel class I or II). Upon pathological examination, 18 patients revealed cortical dysplasia, 4 patients revealed tumor, and 2 patients revealed cortical scar. The hypometabolic lesions were found in F-18 FDG PET by visual assessment and SPM analysis. On SPM analysis, cutoff threshold was changed. Results: MRI showed structural lesions in 12 patients and normal results in the remaining 12. F-18 FDG PET correctly localized epileptogenic zones in 13 patients (54%) by visual assessment. Sensitivity of F-18 FDG PET in MR-negative patients (50%) was similar to that in MR-positive patients (67%). On SPM analysis, sensitivity decreased according to the decrease of p value. Using uncorrected p value of 0.05 as threshold, sensitivity of SPM analysis was 53%, which was not statistically different from that of visual assessment. Conclusion: F-18 FDG PET was sensitive in finding epileptogenic zones by revealing hypometabolic areas even in MR-negative patients with frontal lobe epilepsy as well as in MR-positive patients. SPM analysis showed comparable sensitivity to visual assessment and could be used as an aid in the diagnosis of epileptogenic zones in frontal lobe epilepsy.

  • PDF

Relationship among porcine lncRNA TCONS_00010987, miR-323, and leptin receptor based on dual luciferase reporter gene assays and expression patterns

  • Ding, Yueyun;Qian, Li;Wang, Li;Wu, Chaodong;Li, DengTao;Zhang, Xiaodong;Yin, Zongjun;Wang, Yuanlang;Zhang, Wei;Wu, Xudong;Ding, Jian;Yang, Min;Zhang, Liang;Shang, Jinnan;Wang, Chonglong;Gao, Yafei
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.2
    • /
    • pp.219-229
    • /
    • 2020
  • Objective: Considering the physiological and clinical importance of leptin receptor (LEPR) in regulating obesity and the fact that porcine LEPR expression is not known to be controlled by lncRNAs and miRNAs, we aim to characterize this gene as a potential target of SSC-miR-323 and the lncRNA TCONS_00010987. Methods: Bioinformatics analyses revealed that lncRNA TCONS_00010987 and LEPR have SSC-miR-323-binding sites and that LEPR might be a target of lncRNA TCONS_00010987 based on cis prediction. Wild-type and mutant TCONS_00010987-target sequence fragments and wild-type and mutant LEPR 3'-UTR fragments were generated and cloned into pmiRRB-REPORTTM-Control vectors to construct respective recombinant plasmids. HEK293T cells were co-transfected with the SSC-miR-323 mimics or a negative control with constructs harboring the corresponding binding sites and relative luciferase activities were determined. Tissue expression patterns of lncRNA TCONS_00010987, SSC-miR-323, and LEPR in Anqing six-end-white (AQ, the obese breed) and Large White (LW, the lean breed) pigs were detected by real-time quantitative polymerase chain reaction; backfat expression of LEPR protein was detected by western blotting. Results: Target gene fragments were successfully cloned, and the four recombinant vectors were constructed. Compared to the negative control, SSC-miR-323 mimics significantly inhibited luciferase activity from the wild-type TCONS_00010987-target sequence and wild-type LEPR-3'-UTR (p<0.01 for both) but not from the mutant TCONS_00010987-target sequence and mutant LEPR-3'-UTR (p>0.05 for both). Backfat expression levels of TCONS_00010987 and LEPR in AQ pigs were significantly higher than those in LW pigs (p<0.01), whereas levels of SSC-miR-323 in AQ pigs were significantly lower than those in LW pigs (p<0.05). LEPR protein levels in the backfat tissues of AQ pigs were markedly higher than those in LW pigs (p<0.01). Conclusion: LEPR is a potential target of SSC-miR-323, and TCONS_00010987 might act as a sponge for SSC-miR-323 to regulate LEPR expression.

Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement (하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구)

  • Lim, Ju-Eun;Lim, Won-Hee;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.397-406
    • /
    • 2008
  • Objective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a $30^{\circ}$ and $45^{\circ}$ angulation upon placement.

The Etiological Role of Legionella Pneumophila in Patients with Community-Acquired Pneumonia in Korea (입원한 지역사회획득 폐렴 환자에서 요중 레지오넬라항원 검사를 통해 본 Legionella Pneumophila 감염의 비중)

  • Song, Hong-Seok;Suh, Ji-Hyeon;Ahn, Jong-Ho;Yoon, Byeong-In;Lee, Seung-Joon;Lee, Myung-Goo;Jun, Man-Jo;Kang, Min-Jong;Lee, Jae-Myung;Kim, Dong-Gyu;Son, Jee-Woong;Park, Myung-Jae;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.409-414
    • /
    • 2001
  • Background : Legionella pneumophila has been recognized as an important cause of community-acquired pneumonia(CAP) requiring hospitalization. However, epidemiological data on the occurrence of legionella-related pneumonia is unavailable in Korea. The purpose of this study was to evaluate the etiological importance of legionella pneumophila serogroup 1 in patients hospitalized with CAP. Method : The CAP patients over 16 year-old were recruited from July 1999 to June 2000 at the Chunchon Sacred Heart Hospital. Fifty four patients (male 29, female 25, average age $63.8{\pm}15.3$) were included in this study. A diagnosis of a legionella pneumophila infection was based on a urinary antigen test using the Binax Company enzyme immunoassay. The severity of pneumonia was assessed using the Fine's PORT scoring system. Result : The average Fine's PORT score was 99.7(${\pm}44.9$). According to the risk classification proposed by the Infectious Disease Society of America, the number of patients in each class(from class I to class V) were 6(11.1%), 13(24.1%), 9(16.7%), 14(25.8%), and 12(22.2%), respectively. Thirty two patients(59.3%) were initially admitted to the intensive care unit. The mortality rate was 16.7%(9 in 54). In all patients, urinary antigens to Legionella pnewnophila serogroup 1 were not detected. Conclusion : Legionella pnewnophila may play little role in causing adult CAP in Korea. Therefore, the routine use of macrolide in the empirical treatment of the CAP patients based upon the ATS guidelines(1993) in Korea should be reevaluated.

  • PDF

Quality characteristics of soybean sprouts packaged with different packaging materials during their storage (포장 필름의 종류에 따른 저장 중 콩나물의 품질특성)

  • Hwang, Tae-Young
    • Food Science and Preservation
    • /
    • v.20 no.5
    • /
    • pp.602-607
    • /
    • 2013
  • Correct packaging enables processors to pack fresh produce and extend its shelf life. This study was carried out to investigate the effect of different packaging materials on the weight loss, pH, $O_2$, $CO_2$ and sensory characteristics of soybean sprouts during their storage at $5^{\circ}C$ for seven days. Soybean sprouts ($320{\pm}20g$) were packaged with oriented polypropylene (OPP) and cast polypropylene (CPP) films, respectively. The $O_2$ transmission rate of the packaging materials was set to have a control of $10,000cc/m^2$.day.atm, and an OP15 and CP15 with $15,000cc/m^2$.day.atm through a pre-screening test. The average weight loss of the soybean sprouts during their storage was less than 10%, and that of the soybean sprouts with a CPP film was higher than that of the OPP film. The pH of the soybean sprouts increased during their storage regardless of their packaging materials; but compared to the pH of the soybean sprouts packaged with OPP, those packaged with CPP were higher. The $CO_2$ content of the packaging increased with a decrease in the $O_2$ content. The ratio of $CO_2$ to $O_2$ in the soybean sprouts with the OPP film was 3.5 times higher than in the soybean sprouts with the CPP film. The results of the overall sensory test showed that the marketability of the soybean sprouts packaged with OPP film and stored at $5^{\circ}C$ seemed to have been maintained effectively for six days (at a $15,000cc/m^2$.day.atm $O_2$ transmission rate). When the correlation coefficients of the control, OP15 and CP15 were analyzed, the highest correlation was shown between a control and OP15 (0.986; p<0.01).

COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS (수 종의 복합레진 접착 시스템에서의 미세 누출의 비교)

  • Seok, Choong-Ki;Nam, Dong-Woo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.636-644
    • /
    • 2004
  • Recently, self-etching adhesive system have been developed and bonding procedures simplified into one or two steps, which are simultaneously applied to both enamel and dentin. These systems are easy to use and have the potential for good clinical success. The purpose of this study is to evaluate in vitro the microleakage on the cementum/dentin and enamel walls in composite resin restoration of Class V cavities, regarding the use of different adhesive systems. 30 human premolars were divided into 3 groups. A standardized Class V preparation was prepared on the buccal and lingual surface of each premolar. The preparation were made parallel to the cementoenamel junctions, with the gingival half of the preparation extending 1mm apical to the cementoenamel junction. After adhesive system was applied to teeth as manufacture's recommendation, hybrid resin composite was filled in bulk into the preparation and light polymerized according to manufacturer's recommendations. Specimen were stored in distilled water at $37^{\circ}C$ for 5 days and thermocycled 1000 times ($5^{\circ}C{\pm}2^{\circ}C\;and\;55^{\circ}C{\pm}2^{\circ}C)$, then immersed in a 2% methylene blue solution for 12 hours. After sectioning mesio distally through the restorations, the degree of dye penetration was scored under a stereomicroscope at ${\times}\;25$ magnification. The data were analyzed statistically using t-test and one-way ANOVA. The results were as follows: ${\cdot}$ There is no adhesive system which can prevent microleakage perfectly. ${\cdot}$ There is significant difference in microleakage between enamel margin and dentin margin (p<0.0001). ${\cdot}$ In enamel margin, self-etching primer systems did not show any significant difference comparing total-etching system. In denin margin, self-etching primer systems did not show any significant difference comparing one-bottle adhesive system used in combination with total-etching.

  • PDF

Improvement of Radiosynthesis Yield of [11C]acetate ([11C]아세트산의 방사화학적 수율 증가를 위한 연구)

  • Park, Jun Young;Son, Jeongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.74-78
    • /
    • 2018
  • Purpose $[^{11}C]$acetate has been proved useful in detecting the myocardial oxygen metabolism and various malignancies including prostate cancer, hepatocellular carcinoma, renal cell carcinoma and brain tumors. The purpose of study was to improve the radiosynthesis yield of $[^{11}C]$acetate on a automated radiosynthesis module. Materials and Methods $[^{11}C]$acetate was prepared by carboxylation of grignard reagent, methylmagnesium chloride, with $[^{11}C]$$CO_2$ gas, followed by hydrolysis with 1 mM acetic acid and purification using solid phase extraction cartridges. The effect of the reaction temperature ($0^{\circ}C$, $10^{\circ}C$, $-55^{\circ}C$) and cyclotron beam time (10 min, 15 min, 20 min, 25 min) on the radiosynthesis yield were investigated in the $[^{11}C]$acetate labeling reaction. Results The maximum radiosynthesis yield was obtained at $-10^{\circ}C$ of reaction temperature. The radioactivities of $[^{11}C]$acetate acquired at $-10^{\circ}C$ reaction temperature was 2.4 times higher than those of $[^{11}C]$acetate acquired at $-55^{\circ}C$. Radiosynthesis yield of $[^{11}C]$acetate increased with increasing cyclotron beam time. Conclusion This study shows that radiosynthesis yield of $[^{11}C]$acetate highly dependent on reaction temperature. The best radiosynthesis yield was obtained in reaction of grignard reagent with $[^{11}C]$$CO_2$ at $-10^{\circ}C$. This radiolabeling conditions will be ideal for routine clinical application.

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.