• Title/Summary/Keyword: Tl-201

Search Result 91, Processing Time 0.042 seconds

Evaluation of the Decontamination Efficiency of Radioactive Wastes Generated during the Production of 201Tl (201Tl의 생산과정에서 발생한 방사성 폐기물의 제염 효율 평가)

  • Heo, Jae-Seung;Kim, Sang-Rok;Kim, Gi-Sub;Ahn, Yun-jin;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.481-487
    • /
    • 2021
  • This study was conducted for the purpose of efficient radioactive waste disposal and management. Experiment was evaluated the decontamination efficiencies of the four types decontamination materials(Water, Alcohol, Decontamination Water, Decontamination Gel) with radioactive wastes generated during radio-pharmaceutical production process at Korea Institute Radiological and Medical Sciences(KIRAMS). The radioactive waste sample used in experiment is a lead plate of the fume hood that was disposed in April, 2019. In the experimental method, radioactive waste was measured before and after decontamination using a HPGe semiconductor detector and Gamma survey meter. The measured values before and after decontamination were evaluated for decontamination efficiency as a percentage. As a result, it was confirmed that a lot of specific activity and surface dose rate was removed from the radioactive wastes. In particular, when decontamination water was used, most of the radioactivity of radioactive wastes was removed. Considering these results, if decontamination water is used in decontamination of radioactive waste, decontamination efficiency equivalent to the disposition criteria can be expected with just one decontamination treatment. In addition, in the case of water and alcohol, only on decontamination was effective in approximately 75% and 95%. Otherwise, when decontamination gel was used, it was confirmed that the largest deviation occurred among all experimental results.

Age and Growth of Barbel Steed Hemibarbus labeo in Goe-san Lake in Korea

  • Lee, Wan-Ok;Zhang, Ming-Ming;Oh, Chul-Woong;Baek, Jae-Min;Song, Kyung-Jun
    • Fisheries and Aquatic Sciences
    • /
    • v.15 no.4
    • /
    • pp.353-359
    • /
    • 2012
  • Age and growth of Hemibarbus labeo caught from Goe-san Lake in South Korea from March to November, 2011, were studied. A total of 201 specimens was collected, ranging from 110 to 580 mm in total length (TL). Males and females made up 47.9% and 52.1% of the sample, respectively. Marginal increment analyses showed that vertebral increments, each composed of one opaque and one hyaline zone, were deposited annually. Opaque edges were prevalent from June to July. The relationship between TL and vertebral radius was linear, with equations of R = 0.008TL - 0.208 (male) and R = 0.009TL - 0.272 (female). Regression equations between TL and total weight (TW) were $TW=9{\times}10^{-6}TL^{2.987}$ (male), $TW=8{\times}10^{-6}TL^{3.014}$ (female), and $TW=9{\times}10^{-6}TL^{2.988}$ (combined sexes), according to the von Bertalanffy growth equation. Back-calculated TL was expressed using the von Bertalanffy equation as follows: $L_t=438.25(1-e^{-0.175(t+0.164)})$ for males, $L_t=483.36(1-e^{-0.147(t+0.115)})$ for females, and $L_t=464.86(1-e^{-0.162(t+0.176)})$ for the sexes combined. The growth performances were 4.526, 4.536, and 4.544, respectively.

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF

Evaluation of Radiation Shielding Rate of Lead Aprons in Nuclear Medicine (핵의학과에서 사용하는 납 앞치마의 방사선 차폐율 평가)

  • Han, Sang-Hyun;Han, Beom-Heui;Lee, Sang-Ho;Hong, Dong-Heui;Kim, Gi-Jin
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Considering that the X-ray apron used in the department of radiology is also used in the department of nuclear medicine, the study aimed to analyze the shielding rate of the apron according to types of radioisotopes, thus ${\gamma}$ ray energy, to investigate the protective effects. The radioisotopes used in the experiment were the top 5 nuclides in usage statistics $^{99m}Tc$, $^{18}F$, $^{131}I$, $^{123}I$, and $^{201}Tl$, and the aprons were lead equivalent 0.35 mmPb aprons currently under use in the department of nuclear medicine. As a result of experiments, average shielding rates of aprons were $^{99m}Tc$ 31.59%, $^{201}Tl$ 68.42%, and $^{123}I$ 76.63%. When using an apron, the shielding rate of $^{131}I$ actually resulted in average dose rate increase of 33.72%, and $^{18}F$ showed an average shielding rate of -0.315%, showing there was almost no shielding effect. As a result, the radioisotopes with higher shielding rate of apron was in the descending order of $^{123}I$, $^{201}Tl$, $^{99m}Tc$, $^{18}F$, $^{131}I$. Currently, aprons used in the nuclear medicine laboratory are general X-ray aprons, and it is thought that it is not appropriate for nuclear medicine environment that utilizes ${\gamma}$ rays. Therefore, development of nuclear medicine exclusive aprons suitable for the characteristics of radioisotopes is required in consideration of effective radiation protection and work efficiency of radiation workers.

Evaluation of Shielding Rate of Bismuth Depending on the Type of Medical Radioisotope (의료용 방사성동위원소의 종류에 따른 비스무트의 차폐율 평가)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.87-93
    • /
    • 2018
  • In this study, $^{99m}Tc$, $^{123}I$, $^{201}Tl$, $^{18}F$, and $^{131}I$, which are widely used in nuclear medicine, were transmitted through a bismuth shield. We investigated the shielding rates according to the type of radioisotope and the distance of measurement. For the experiment, 6 sheets of lead equivalent 0.25 mm Pb of bismuth shielding material were stacked one by one up to 1.50 mm as the thickness increased. The distance was 30 cm, 50 cm, and 100 cm, and the transmission dose was measured. As a result, the shielding rates was measured as the thickness increased, and the measured value decreased as the distance increased. The shielding rate of $^{123}I$ and $^{201}Tl$ was higher than $^{99m}Tc$, $^{18}F$ and $^{131}I$ showed lower shielding effect when there is a shielding material than when there is no shielding material due to high energy and ${\beta}$ rays. Based on the results of experiments, it would be helpful to reduce the exposure of nuclear medicine workers and to manage the exposure if bismuth shields are used depending on the type of radioisotope.

Quantitative Analysis of Thallium-201 Myocardial Tomograms (Thallium-201 심근 단층영상의 정량적 분석)

  • Kim, Sang-Eun;Nam, Gi-Byoung;Choi, Chang-Woon;Choi, Kee-Joon;Lee, Dong-Soo;Sohn, Dae-Won;Ahn, Cu-Rie;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Choi, Yun-Shik;Seo, Jung-Don
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.165-176
    • /
    • 1991
  • The purpose of this study was to assess the ability of quantitative Tl-201 tomography to identify and localize coronary artery disease (CAD). The study population consisted of 41 patients (31 males, 10 females; mean age $55{\pm}7$ yr) including 14 with prior myocardial infarction who underwent both exercise Tl-201 myocardium SPECT and coronary angiography for the evaluation of chest pain. From the short axis and vertical long axis tomograms, stress extent polar maps were generated by Cedars-Sinai Medical Center program, and the % stress defect extent (SDE) was quantified for each coronary artery territory. For the purpose of this study, the coronary circulation was divided into 6 arterial segments, and the "myocardial ischemic score" (MIS) was calculated from the coronary angiogram. Sensitivity for the detection of CAD ($\geq50%$ coronary stenosis by angiography) by angiography) by stress extent polar map was 95% in single vessel disease, and 100% in double and triple vessel deseases. Overall sensitivity was 97%. Sensitivity and specificity for the detection of individual diseased vessels were, respectively, 87% and 90% for the left anterior descending artery (LAD), 36% and 93% for the left circumflex artery (LCX), and 71% and 70% for the right coronary artery (RCA). Concordance for the detection of individual diseased vessels between the coronary angiography and stress polar map was fair for the LAD (kappa=0.70), and RCA (kappa=0.41) lesions, whereas it was poor for the LCX lesions (kappa : 0.32). There were siginificant correlations between the MIS and SDE in LAD (rs=0.56, p=0.0027), and RCA territory (rs=0.60, p=0.0094). No significant correlation was found in LCX territory. When total vascular territories were combined, there was a significant correlation between the MIS and SDE (rs=0.42, p=0.0116). In conclusion, the quantitative analysis of Tl-201 tomograms appears to be accurate for determining the presence and location of CAD.

  • PDF