• Title/Summary/Keyword: Titanium insert

Search Result 16, Processing Time 0.016 seconds

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Evaluation of Metal Artifact Reduction for Orthopedic Implants (O-MAR) on Radiotherapy Treatment Planning (방사선 치료 계획 시 O-MAR (Metal Artifact Reduction for Orthopedic Implants) 적용의 유용성 평가)

  • Won, Huisu;Hong, Joowan;Kim, Sunyoung;Choi, Jaehyock;Cho, Jaehwan;Yang, Hanjoon;Lee, Jin;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.217-223
    • /
    • 2014
  • The aim of this study is evaluation of dose distribution on radiation therapy planning system with the CT image of high-density material inserted phantom. Gammex 467 Tissue Characterization Phantom is used to acquire an image similar to the human tissues and insert a Titanium to generate metal artifact. The acquired images were reconstructed with Metal Artifact Reduction for Orthopedic Implants (O-MAR). By using the treatment planning system, the volume was analyzed and dose distribution was extracted. Photon dose distribution in linear accelerator was measured by the $MapCHECK^{TM}$ and compared with planned and measured dose distributions. In result of the comparative analysis, when artifact is generated by Titanium, The volume applied O-MAR was increased 6.8% to BR-12 Breast and 40.2% to LV 1 Liver. After O-MAR was used, Dose distribution was higher 1.4 to 1.6% than before. Consequently, The artifact caused by metal objects should be removed if possible, and after that used in the radiotherapy treatment plan can be considered to reduce errors.

A Study on the Life Enhancement of TiN Coated Drill (TiN 박막을 코팅한 드릴의 수명향상에 관한 연구)

  • 김홍우;김문일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2340-2348
    • /
    • 1992
  • Recently, various film coated insert tools have been used in order to improve tool life by several different vapor deposition or chemical vapor deposition. Especially, TiN coated drills have been broadly studied because of improving drill performance in terms of drill life, work quality and its brilliant color. Nevertheless, because of the poor adhesion between TiN film and drill, it was difficult to attain the better drill performance. Therefore, to improve adhesion of TiN films, we sputtered titanium as interlayer prior to TiN deposition on drill by PECVD(Plasma Enhanced Chemical Vapor Deposition). The results indicate that Ti/TiN coated drills achieve about 2.6 times life improvement, while TiN coated drills only 2 times. Wear characteristics of tested drills were examined using SEM, and the results were correlated with drill life and roughness of drilled holes.

Quantitative Analysis of 3D-CRT Radiotherapy Planning Factors with or without IR in Patients with High Density Artifacts (고밀도 인공물 환자에서 반복적 재구성 사용 유무에 따른 3차원 입체조형 방사선 치료 계획 인자의 정량분석)

  • Lee, Gyu-Wook;Choi, U-Hyeong;Jung, Yae-Hyun;Lee, Joo-Hee;Yun, In-Ha;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.7-14
    • /
    • 2020
  • The purpose of this study is to assess the usefulness of IR to compensate for uncertainties in inserting high density artificial objects in radiation treatment planning in the 3D-CRT treatment technique. CT images of the subjects with phantom and titanium inserted were obtained from images without IR and images with IR, and the dose evaluation factors HI, MU and volume evaluation factors Volume and PCI were compared. The results of the stainless steel and titanium phantom experiments showed that the volume of high density artificial material was reduced by 4.850% and 11.456% respectively when applying IR. MU decreased 0.924% and 1.181%. HI was down 0.106% and 0.272%. PCI decreased 0.358% and 0.867%. When IR was applied to CT images of subjects with vertebroplasty, Femur alignment pin and wrist alignment pin, the volume of artifacts decreased by 47.76%, 23.841%, and 49.339%. MU also decreased 0.924%, 0.294% and 1.675%, while HI decreased 1.232%, 0.412% and 1.695%. PCI decreases 4.022%, 0.512%, and 13.472%. In conclusion, When IR was applied to 3D-CRT treatment plan, both dose and volume in phantom and subject case with high density artificial insert were reduced.

Transient Liquid Phase Bonding of Directionally Solidified Ni Base Superalloy, GTD-111(III) - The Effect of Homogenizing and Aging on the Microstructures and Mechanical Properties - (일방향응고 Ni기초내열합금 GTD-111의 천이액상확산접합(III) - 미세조직 및 기계적 성질에 미치는 균질화처리 및 시효처리의 영향 -)

  • 강정윤;황형철;김인배;김대업;우인수
    • Journal of Welding and Joining
    • /
    • v.21 no.3
    • /
    • pp.78-84
    • /
    • 2003
  • The changes of microstructure and hardness of TLP bonds of directionally solidified Ni base superalloy, GTD-111, with variation of homogenizing and aging treatment were investigated. The specimens were bonded at 1403K for 7.2ks using different insert metals such as MBF-50, MBF-80 and MBF-90 and they were homogenized at 1393K with various holding time. At center of bonded interlayer homogenized for hold time 30h, the contents of aluminum and titanium were approximately 90% and 95% of base metal, respectively. In this study, aging was performed at three different kinds : one step aging ; 1113K $\times$ 16h, two step aging ; 1113K $\times$ 10h ⇒ 1103K $\times$ 10h, three step aging ; 1113K $\times$ 10h ⇒ 1103K $\times$ 8h ⇒ 922K $\times$ 24h. ${\gamma}$' volume fraction and hardness of joints were high in the sequence of one step, two step and three step aging, whereas ${\gamma}$' volume fraction and hardness of joints obtained by three step aging treatment were higher than those of raw material. Tensile properties of joints bonded with MBF-80 and MBF-90, homogenized at 1393K for 30h and then three step aged became excellent than those of raw material, however, joint bonded with MBF-50 was poor.

Evaluation of friction of ceramic brackets in various bracket-wire combinations (브라켓 각도 변화에 따른 세라믹 브라켓의 마찰력 측정)

  • Cha, Jung-Yul;Kim, Kyung-Suk;Kim, Dong-Choon;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.125-135
    • /
    • 2006
  • The purpose of this study was to measure and compare the level of frictional resistance generated from three currently used ceramic brackets; 1, Crystaline $V^{(R)}$, Tomy International Inc., Tokyo, Japan; 2, $Clarity^{(R)}$, 3M Unitek, Monrovia, CA, USA; 3, $Inspire^{(R)}$, Ormco, Orange, CA, USA; with composite resin brackets, Spirit, Ormco, Orange, CA, USA; and conventional stainless steel brackets, Kosaka, Tomy International Inc., Tokyo, Japan used as controls. In this experiment, the resistance to sliding was studied as a function of four angulations $(0^{\circ},\;5^{\circ},\;10^{\circ}\;and\;15^{\circ})$ using 2 different orthodontic wire alloys: stainless steel (stainless steel, SDS Ormco, Orange, CA, USA), and beta-titanium (TMA, SDS Ormco, Orange, CA, USA). After mounting the 22 mil brackets to the fixture and $.019{\times}.025$ wires ligated with elastic ligatures, the arch wires were slid through the brackets at 5mm/min in the dry state at $34^{\circ}C$. Silica-insert ceramic brackets generated a significantly lower frictional force than did other ceramic brackets, similar to that of stainless steel brackets. Beta-titanium archwires had higher frictional resistance than did stainless steel, and all the brackets showed higher static and kinetic frictional force as the angulation increased. When the angulation exceeded $5^{\circ}$, the active configuration emerged and frictional force quickly increased by 2.5 to 4.5-fold. The order of frictional force of the different wire-bracket couples transposed as the angle increased. The silica-insert ceramic bracket is a valuable alternative to conventional stainless steel brackets for patients with esthetic demands.