• Title/Summary/Keyword: Titanium implant

Search Result 572, Processing Time 0.027 seconds

Survival of 352 titanium implants placed in 181 patients: a 4-year multicenter field study

  • Shin, Seung-Il;Yun, Jeong-Ho;Kim, Sung-Geun;Park, Byoungkyou;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.1
    • /
    • pp.8-12
    • /
    • 2014
  • Purpose: The aim of this retrospective chart review was to evaluate the four-year survival rate of a titanium implant system. Methods: A total of 352 sand-blasted, thermally acid-etched titanium implants were inserted into 181 partially or completely edentulous patients. Their cumulative survival rate was evaluated retrospectively. Associated factors, such as the implant distribution and treatment type were included in the evaluation. Results: The implants were equally distributed between the maxilla (52.3%) and the mandible (47.7%). 48 implants (13.6%) were placed in the anterior region and 304 implants (86.4%) in the posterior region. The majority of the implants were inserted into bone of type II and III quality (89.8%) and volume (quantity B and C, 87.2%). Most of the implants (70.7%) were restored as single crowns; 28.7% supported a bridge construction and 0.6% a full denture. Only one implant failed, resulting in a four-year cumulative survival rate of 99.7%. Conclusions: The implant system showed an excellent four-year survival rate. It proved to be a safe and predictable means for restoration of the dentition in partially or completely edentulous patients.

Expression of Growth factors during Osseointegration of Titanium Implant ; TGF-$\beta$, IGF-I, BMP2, BMP4 (타이타늄 임플란트 골유착시 성장인자들의 발현 ; TGF-$\beta$, IGF-I, BMP2, BMP4)

  • Jee, Yu-Jin;Kim, Soo-Hyun
    • The Journal of the Korean dental association
    • /
    • v.46 no.8
    • /
    • pp.494-504
    • /
    • 2008
  • Osseointegration is a result of bone formation and bone regeneration process, which take place at the interface between bone and implant and biologic determinants such as cytokine, growth factors, bone matrix proteins play an important role in osseointegration. The purpose of this study is to compare the expressoin of TGF-$\beta$, IGF-I, BMP2, BMP4 during osseointegration. We designed an experimental group which was inserted with a RBM surface titanium implants and machined surface, and compared with a control group which had a simple bone cavity and normal bone. Titanium implants were placed into tibia of 8 rabbits. We compared the expression of TGF-$\beta$, IGF-I, BMP2, BMP4 using RT_PCR (reverse transcriptase chain reaction)analysis in day 3,7,14 and 28 of implant insertion. According to the results, growth factors of experimental groups were more expressed than control groups. Among experimental groups, expression of TGF-$\beta$, IGF-I, BMP4 of BMP group had tedency to increase more at 14th, 28th days than Machined surface group. Therefore, our results suggest that TGF-$\beta$, IGF-I, BMP4 are expressed within the bone around the implant and more increased around rough surface implants while osseointegration occurs after dental implant insertion.

  • PDF

The skeletal cortical anchorage using titanium microscrew implants (Titanium microscrew implant를 이용한 skeletal cortical anchorage)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.699-706
    • /
    • 1999
  • Anchorage plays an important role in orthodontic treatment. Endosseous implants may be considered adequate firm anchorage. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period before osseointegration occurs. Recently, some clinicians have tried to use titanium miniscrews and microscrews in treatment due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and the ability to place microscrews in any area of alveolar bone. The author treated a case with skeletal cortical anchorage using titanium microscrew implants. During six months of orthodontic force application from skeletal cortical anchorage, the author could get 4 mm bodily retraction and intrusion of upper anterior teeth. The most outstanding result was a 1.5 mm posterior refraction of the upper posterior teeth. The titanium microscrew implants had remained firm and stable throughout treatment. These results indicate that skeletal cortical anchorage might be a very good option.

  • PDF

An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis

  • Yesilyurt, Nilgün Gulbahce;Tuncdemir, Ali Riza
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.216-225
    • /
    • 2021
  • PURPOSE. The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA). MATERIALS AND METHODS. This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Three-dimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15° and 30° under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis. RESULTS. Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force. CONCLUSION. The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.

Comparison of removal torque of saline-soaking RBM implants and RBM implants in rabbit tibias (토끼의 경골에서 RBM 표면처리 임플란트와 RBM 표면처리 후 Saline에 적신 임플란트의 제거회전력 및 표면분석 비교)

  • Kwon, Jae-Uk;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of the titanium implant soaked in saline after RBM surface treatment on the initial osseointegration by comparing the removal torque and the surface analysis compared to the titanium implant with only RBM surface treatment. Materials and methods: The control group was RBM surface treated implants (RBM), and the test group was implants soaked in saline for 2 weeks after RBM surface treatment (RBM+Sal). The control and test group implants were placed in the left and right tibiae of 10 rabbits, respectively, and at the same time, the insertion torque (ITQ) was measured. After 10 days, the removal torque (RTQ) was measured by exposing the implant site. FE-SEM, EDS, Surface roughness and Raman spectroscopy were performed for the surface analysis of the new implant specimens used in the experiments. Results: There was no significant difference in insertion torque and removal torque between RBM surface treated titanium implants and saline-soaked titanium implants after RBM surface treatment. Conclusion: Saline soaking after RBM surface treatment of titanium implants did not positively affect the initial osseointegration as compared to titanium implants with only RBM surface treatment.

EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS (Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가)

  • Park, Jee-Hyun;Hwang, Sun-Jung;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

The Fabrication of Implant Core Coated with Ti Balls (Ti ball이 coating된 임플란트 core의 제조)

  • Choi, D.J.;Park, D.G.;Park, S.B.;Park, S.S.;Turaev, F.R.;Roh, J.S.;Kim, S.J.;Woo, H.S.;Kim, S.E.;Lee, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.2
    • /
    • pp.94-100
    • /
    • 2008
  • The implant prototypes with various porosities were fabricated by Spark Plasma Sintering of atomized spherical titanium balls. The interface was observed by optical microscope. Sintering temperature and holding time were selected at the point of big change of Z-axis ratio during sintering. These experiments show that Spark Plasma Sintering of spherical titanium balls can be efficiently used to produce implants surfaced with titanium balls with various porosities in a short time less than 120 seconds by manipulating the current condition such as z-axis, temperature and balls size.

The Effects of Citric Acid on HA coated Implant Surface (구연산 HA임플란트 표면구조에 미치는 영향)

  • Kim, Joong-Cheon;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-II
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.575-584
    • /
    • 2007
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, and HA coated surface were utilized. Pure titanium machined surface and HA coated surface were rubbed with pH 1 citric acid for 30s., 45s., 60s., 90s., and 120s. respectively. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. The specimens showed a few shallow grooves and ridges in pure titanium machined surface implants. The roughness of surfaces conditioned with pH 1 citric acid was slightly increased. 2. In HA-coated surfaces, round particles were deposited irregularly. The specimens were not significant differences within 45s. But, began to be changed from 60s. The roughness of surfaces was lessened and the surface dissolution was increased relative to the application time. In conclusion, pure titanium machined surface implants and HA coated surface implants can be treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.

A STUDY OF SCREW LOOSENING AFTER DYNAMIC CONTINOUS FATIGUE TEST OF SEVERAL ABUTMENT SCREW (수종 임플랜트 지대주나사의 반복하중 후 나사풀림에 관한 연구)

  • Kim Jin-Man;Han Jung-Suk;Lee Sun-Hyung;Yang Jae-Ho;Lee Jae-Bong;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.519-531
    • /
    • 2003
  • Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.

Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study

  • De Oliveira, Greison Rabelo;Pozzer, Leandro;Cavalieri-Pereira, Lucas;De Moraes, Paulo Hemerson;Olate, Sergio;De Albergaria Barbosa, Jose Ricardo
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.217-223
    • /
    • 2012
  • Purpose: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. Methods: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. Results: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. Conclusions: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.